Search NASA⌕ Search

SEARCH · Search NASA

Results for “Leak Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2022 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 10.4 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 12.5 years. This year, one GLT-S O-ring fixture failed after 12.4 years aging at 200 °F. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 25 mock-up PCV fixtures.

36 MATERIALS SCIENCE↗

Characterization of an explosively bonded aluminum proton beam window for the Spallation Neutron Source

An effort is underway at the Spallation Neutron Source (SNS) to change the design of the 1st Generation high-nickel alloy proton beam window (PBW) to one that utilizes aluminum for the window material. One of the key challenges to implementation of an aluminum PBW at the SNS was selection of an appropriate joining method to bond an aluminum window to the stainless steel bulk shielding of the PBW assembly. An explosively formed bond was selected as the most promising joining method for the aluminum PBW design. A testing campaign was conducted to evaluate the strength and efficacy of explosively formed bonds that were produced using two different interlayer materials: niobium and titanium. The characterization methods reported here include tensile testing, thermal-shock leak testing, optical microscopy, and advanced scanning electron microscopy. All tensile specimens examined failed in the aluminum interlayer and measured tensile strengths were all slightly greater than the native properties of the aluminum interlayer, while elongation values were all slightly lower. A leak developed in the test vessel with a niobium interlayer joint after repeated thermal-shock cycles, and was attributed to an extensive crack network that formed in a layer of niobium-rich intermetallics located on the bond interfaces of the niobium interlayer; the test vessel with a titanium interlayer did not develop a leak under the conditions tested. Due to the experience gained from these characterizations, the explosively formed bond with a titanium interlayer was selected for the aluminum PBW design at the SNS.

316L Stainless Steel↗

In-situ Detection of Glovebox Glove Degradation Prior to Glove Failure; Effects on Safety, Waste, and Operational Costs - 20402

Glovebox glove pressure decay leak testing and analysis of the data can greatly improve glovebox safety, minimize Transuranic (TRU) glove waste, and minimize operational cost. It is well known, the weakest point of containment on a glovebox is the glove. Mitigating unplanned openings in gloves is critical to minimizing operational and safety costs in glovebox operations. Mitigating unplanned glove openings due to glove failures will be discussed in this paper. The lack of an engineered solution to determine a gloves operational life in nuclear operations, has lead to use of theoretical and manual subjective methods to determine the life and safety of a glovebox glove. Whether the glove is inspected visually prior to use, or gloves are changed regularly to theoretically avoid failure, both the operators PPE and the room are being exposed to contamination, or un-necessary amounts of TRU glove waste are being generated. Millions of dollars yearly in operational costs are spent on glove failures due to loss of production, incident analysis, regulatory audits, clean up, and paperwork. In a nuclear application, a glove failure could contaminate an operator and laboratory, shut down the operation for weeks, potentially create a regulatory audit, and potentially create a media frenzy; the damages to the organization can be astronomical. Elimination of glove failures is possible by tracking glove material degradation and setting limits to allow glove change when it becomes necessary, prior to glove failure. Analytical pressure decay leak testing allows the detection of material degradation, and in turn the ability to limit operational glove failures. A German based company called MK Versuchsanlagen, e.K., has developed an advanced Glove Integrity Testing System. The system, with its use of proprietary RFID and special software technology, is unique in its capabilities. The system is capable to perform highly accurate regular glove testing on any size glovebox line in minimal time. The system records and can analyze a tremendous amount of system data that in turn can determine, for example, a safe glove change time prior to a glove material failure. This paper will show how an advanced Glove Integrity Testing System can detect glove material degradation and help determine a safe change point prior to glove failure. Pressure decay curves of new gloves and recorded effects of accelerated aging on the glove over time will be shown. The use of this technology in nuclear facilities can greatly improve glovebox operational safety, minimize glovebox glove TRU waste, and save organizations tremendous costs in downtime, clean up, documentation, and potential regulatory review. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model 9975 O Ring Fixture Long-Term Leak Performance (FY2024 Status Report)

Leak testing experiments to monitor the aging performance of Viton ® GLT and GLT-S O-rings used in the model 9975 shipping package have been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The mock-up PCV fixtures are leak tested periodically, and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years of aging without failure. Two of these retired fixtures were returned to testing and heated to 350 °F to evaluate the impact of additional heating at higher temperature for aged O-rings. Fixture #20 failed after 3 months of testing while fixture #18 remained leak tight. These O-rings demonstrated that aged and in-service O-rings can continue to be used, even at higher temperatures, after being in storage, and their leak performance are consistent with other samples at 350 °F.

42 ENGINEERING↗

Destructive Examination Protocol for 3013-Container-Package Storing Plutonium-Bearing Materials

The 3013-container-package consists of a convenience, inner and outer container and is used for long-term storage of plutonium-bearing materials. A destructive examination (DE) protocol has been developed to examine the container package visually and with microscopic aid to find any corrosion conditions that could result in the loss of the integrity of the container package over its lifetime. The DE protocol contains three main steps: initial container examination, helium (He) leak testing, and detailed imaging and analysis of the inner container closure weld region (ICCWR). The ICCWR has been determined to be bounding, defined as exhibiting worst case conditions for stress corrosion cracking (SCC) of the inner container. To assess SCC in the ICCWR, the inner container lid is cut into quarters and the weld and He-leak testing gasket are removed. Then a citric acid wash is performed to remove adherent chlorides from the ICCWR. The wash is then sent for analysis to determine the concentration of chlorides in the ICCWR. While the analysis for chloride concentration is being performed, the quarter sections are further sectioned into 1/8th subsections by cutting each section in half. These subsections are washed using nitric acid to remove corrosion products. Then each subsection is imaged using a Wide Angle 3-D Measurement System (WAMS). After analysis of microscope images for potential SCC, additional imaging can be performed, including subsurface imaging. After review, a determination is made of whether the container integrity may potentially affect the safe storage of the material.

container↗

Technical Guidance for Creation of 237 NP Irradiation Target Fabrication Packages

This document describes the process used to document the fabrication of irradiation targets that may be inserted into either the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL), or the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). The targets are being irradiated to produce 238 Pu (5.48Mev alpha decay, T1/2 = 87.7 y) used in the fabrication of radioisotope thermoelectric generators (RTGs). RTGs powered by 238 Pu are an established power source technology for National Aeronautics and Space Administration space missions where solar power is not viable. The documentation included in fabrication files demonstrates full traceability of all materials, components, and assemblies used to build 237 Np targets. To accomplish this, all documentation (e.g., certified material test reports, weld reports, leak test reports) will be maintained and reviewed throughout materials procurement, component fabrication, and target assembly.

07 ISOTOPE AND RADIATION SOURCES↗

SRNL's Lessons Learned from the University of Nevada Reno{sup TM} Nuclear Packaging Internships - 19464

The U.S. Department of Energy's Packaging Certification Program (DOE PCP) and the University of Nevada, Reno (UNR) Mechanical Engineering Department have developed an accredited, graduate level nuclear packaging certificate. The mission is to ensure that the DOE staff and users of PCP services are knowledgeable and competent in packaging and transportation activities. Since 2008, the Savannah River National Laboratory (SRNL) has been teaching two classes for the DOE PCP Packaging University. This paper introduces a recently added third class, where SRNL provided Site Supervisors, targeted toward engineering interns. As part of ensuring a future workforce, the Packaging Technology and Transportation Engineering Group (PT and TE) at Savannah River National Laboratory (SRNL) normally employs two to three summer interns each year. The internships provide SRNL innovative s performing valuable research and support work related to package certification. It also provides SRNL the opportunity to bring in perspective engineers on 'trial-basis.' The interns benefit by learning valuable career skills and gaining exposure to a broad-based career field in the field of packaging. As part of the job specific training, the summer interns are provided an overview of package design, testing, and certification. This includes package operations, containment vessel leak testing, and SARP preparation. Two years ago, SRNL recognized the efficiency of using the SRNL-taught courses for the summer interns working in SRNL PT and TE. SRNL requested that UNR allow the PT and TE two summer interns, who were rising college juniors, to enroll in the SRNL-taught courses for graduate credit. UNR agreed and allowed the interns to enroll under a special admission status. Since that time, UNR developed a new class within the Graduate Certificate in Nuclear Packaging (GCNP), for the summer intern research work. This new class offers a formalized framework for the summer interns to conduct research, while ensuring that the research is performed in a rigor consistent with an accredited college level setting. Last summer, the SRNL PT and TE had three summer interns - all participating in the new course, UNR ME-699 Nuclear Packaging Summer Internship - with each earning three graduate credits from UNR in mechanical engineering. This paper provides a brief overview of the DOE PCP Packaging University/ UNR GCNP, a discussion of SRNL's use of summer interns as a tool to recruit and train the future workforce, and lessons learned from having last year's three SRNL PPT and TE summer interns enroll in the UNR Packaging Internship Class. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

3-60B Type-B shipping cask enhanced operational features to facilitate leakage rate testing - 15585

EnergySolutions is fabricating a new 3-60B Type B Shipping Cask that will be ready for use in spring 2015, designed for shipping Type B quantities of activated and/or non-fuel-bearing reactor or accelerator components. EnergySolutions, in consult with Leak Testing Specialists, Inc., has implemented an improved design of the 3-60B cask closures to better facilitate periodic and maintenance leakage rate testing and to allow end users to more easily perform pre-shipment leakage rate testing to confirm proper assembly of the cask closures. A typical Type B cask closure lid design incorporates a double O-ring configuration, where the inner O-ring provides containment and the outer O-ring is used for leakage rate testing of the containment O-ring seal. Leakage rate testing of a double O-ring configuration is typically accomplished by filling the cask cavity with helium, pulling a vacuum on the annular space between the two O-rings and monitoring for helium leakage through the containment O-ring. One issue is the potential for helium saturation of the O-ring elastomeric material, which can result in leakage rate test failures. The cask cavity volume is typically large, and takes a significant amount of time to fill with helium. As a result, the saturation time for certain elastomeric compounds may be exceeded, leading to potential false-negative leakage rate testing results. To avoid this, that the cask cavity typically is loaded with sealed container(s) to reduce the free volume and the fill time. The improved 3-60B cask closure lid incorporates a triple O-ring seal configuration that facilitates maintenance leak rate testing of the closure lid containment O-ring seal and eliminates the issues discussed above. The triple O-ring configuration uses the middle O-ring as the containment seal, with the inner and outer test O-rings creating relatively small annular volumes for testing purposes. These small annular volumes are quick to fill, minimizing the issue of Helium saturation of the O-ring material. This seal configuration also makes it possible to detect and replace a damaged O-ring seal during loading operations, or dress a damaged sealing surface, and perform the required maintenance leakage rate testing of the replacement O-ring at the plant site without the need to unload the cask and send it to a maintenance facility. Also, a second test port has been added to each O-ring annulus to allow leakage rate testing to be accomplished using a formal system calibration that complies with the requirements and recommendations of ASME Section V, Article 10 [4], ANSI N14.5-97 [2], and ANSI N14.5-2014 [3]. This provides a simple, reliable, and accurate means to perform leakage rate testing with a test confidence level that cannot be achieved without the second test port. The improved closure and test port design simplifies and shortens the time required to perform leakage testing, resulting in reduced operating costs, greater schedule security, and dose savings for the cask users. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

REGULATORY TESTING AND POSTTEST ANALYSIS OF THE DPP-3 TYPE B SHIPPING CONTAINER FOR NCT AND HAC TESTS

The safe transportation of radioactive material using appropriately designed and certified transportation packages is important to protect the public and environment. Therefore, a comprehensive and rigorous system of packaging requirements are required. The purpose of this test protocol is to determine the effects of drop testing on package performance in a Type B shipping package (DPP-3). Required physical tests for the DPP-3 package include normal conditions of transport and hypothetical accident conditions test requirements. The preparation, regulatory testing, and post-test evaluation of a Type B shipping package tested to the 10 CFR 71.71 and 10 CFR 71.73 requirements will be presented. Six packages were tested and the responses when subjected to the HAC sequence of free drop, puncture, and thermal tests according to 10 CFR 71.73 were measured. The posttest helium leak test showed a leak rate less than 1 × 10-7 He-cc/sec which means that the containment boundary was maintained after the regulatory testing, therefore maintaining a leak tight environment. To determine the amount of change in the package performance measurements, statistical analyses were conducted using SPSS version 26. The null hypothesis of the testing was that there would not be a change in the measurements from pre to post-testing large enough to find statistical significance. Therefore, a finding of statistical significance indicated too much variability in the package design and was deemed an unfavorable finding. A repeated measures t-test was used to analyze the drum lids and CV torques. A one-way ANOVA was used to analyze height and diameter packages. Results of the repeated measures t-test indicated that all six containment vessel lid torques were statistically significant. However only three out of the six drum lid torques were statistically significant. Therefore, design of the lids caused more variability than necessary when subjected to the following drop tests: 1.) horizontal and cold; 2.) vertical lid down; and 3.) corner with lid up. Results of the one-way ANOVA analysis on height indicated that four out of the six CTUs were statistically significant. Thus, design of the CTUs caused more variability then necessary when subjected to the following drop tests: 1.) horizontal hot; 2.) horizontal cold; 3.) corner lid up; and 4.) corner lid down. Results of the one-way ANOVA analysis on diameter indicated that all six CTUs were statistically significant. Thus, design of the CTUs caused more variability then necessary when subjected to all of the tests. The DPP-3 design has been shown to be an acceptable design for the transport of radioactive materials. However, results of the statistical analysis reveal a possible improvement in package and test design to reduce variability in package performance measurement before and after testing.

Martinez, Oscar↗

Aging Behavior of the Viton® Fluoroelastomer O-Rings in the 9975 Shipping Package

The 9975 Type B shipping package is used within the DOE complex for shipping special nuclear materials. This package is re-certified annually in accordance with Safety Analysis Report requirements. The package is also used at the Savannah River Site as part of the long-term storage configuration of special nuclear materials. As such, the packages do not undergo annual recertification during storage, with uncertainty as to how long some of the package components will meet their functional requirements in the storage environment. The packages are currently approved for up to 15 years storage, and work continues to provide a technical basis to extend that period. This paper describes efforts by the Savannah River National Laboratory (SRNL) to extend the service life estimate of Viton® GLT and GLT-S fluoroelastomer O-rings used in the 9975 shipping package. O-rings of both compositions are undergoing accelerated aging at elevated temperature, and are periodically tested for compression stress relaxation (CSR) behavior and leak performance. The CSR behavior of O-rings was evaluated at temperatures from 79 °C to 177 °C. These collective data were used to develop predictive models for extrapolation of CSR behavior to relevant service temperatures (< 75 °C). O-rings were also aged in Primary Containment Vessel (PCV) fixtures at temperatures ranging from 79 °C to 232 °C. The fixtures are helium leak tested periodically to determine if they remain leak-tight. The PCV fixture tests demonstrate that the 9975 O-rings will remain leak-tight at temperatures up to 149 °C for 3 years or more, and no leak failures have been observed with up to 8 years aging at 93 °C. Significantly longer periods of leak-tight service are expected at the lower temperatures actually experienced in the storage environment. The predictive model developed from the CSR data conservatively indicates a service life of more than 20 years at the bounding temperature of 75 °C. Although the relationship between CSR behavior and leak-tight performance has not been established for this design, the CSR predictions for this O-ring are conservative relative to leak-tight performance to date.

36 MATERIALS SCIENCE↗

Fabrication of compact electron gun for 6 MeV X-ray source

The 6 MeV X-Ray source for container cargo scanning application has been designed and developed by the Accelerator and Pulse Power Division, BARC, Mumbai. This compact linac has been designed as a mobile system, to be mounted on a moving container. In linac-based cargo-scanning system, to work electron gun on a movable container, it has to be robust. Electron gun is to work at 10{sup -7} mbar vacuum and 2000 degree Celsius temperature. An effort is made to engineer the gun assembly to make it more robust and aligned. The linac acts as the source of X-rays, which fall on the cargo and are then detected by the detector system. Many components are indigenously developed like grid, insulating ring, Tungsten filament and filament guide, which are made from alumina ceramic and Tantalum which is to work at 1500 degree Celsius. Filament connector is made from Invar to reduce heat loss and to make rigid connection. It was CNC machined and wire cut by EDM. Invar and Copper electrode feed through is shrink fitted with the help of liquid Nitrogen. Shrink fit tolerances of 15 micrometer are achieved by jig boring machining processes. Tantalum cup for LaB6 cathode and heat shield are made from die and punch mechanism. For alignment of electron emitter with beam axis this Tantalum cup is a crucial component. Electron gun is assembled and aligned its components with the help of precision jigs. The whole assembly was Helium leak tested by MSLD up to 4 x 10{sup -10} mbar.l/s vacuum, no leak was found. This paper will describe the machining, Tantalum cup forming, ceramic components development, heat shields, ceramic feed through etc of electron gun. (author)

43 PARTICLE ACCELERATORS↗

Aging Behavior of the EPDM O-Rings in the H1616 Shipping Package

The H1616 shipping package is used within the DOE complex for shipping tritium reservoirs. The annual recertification frequency can create logistical difficulties with other constraints on the timing of shipments; thus, a longer re-certification period is desirable. The ethylene propylene diene monomer (EPDM) O-rings used in the H1616 shipping package are being aged and tested at the Savannah River National Laboratory (SRNL) to provide a technical basis for extending the annual maintenance of the H1616 shipping package. H1616 EPDM O-rings are being aged at elevated temperature, and tested for degradation in mechanical properties, compression stress relaxation (CSR) behavior, and leak performance. Mechanical properties of aged O-rings show significant degradation can occur, but an inert atmosphere (argon backfill) greatly reduces the rate of degradation. The CSR behavior of O-rings was evaluated in air at 79 to 177 °C. These collective data were used to develop a predictive model for extrapolation of CSR behavior to relevant service temperatures (<67 °C). O-rings were also aged in H1616 Containment Vessels (CV) in an inert atmosphere at 71 to 149 °C. The vessels are helium leak tested periodically to determine if they continue to remain leak-tight. The vessel tests provide a solid demonstration that the H1616 O-rings will remain leak-tight at temperatures up to 113 °C for up to approximately 2.3 years. Significantly longer periods of leak-tight service are expected at the lower temperatures actually experienced in service. The predictive model developed from the CSR data conservatively indicates a service life of ~5 years at 67 °C. Although the relationship between CSR behavior and leak-tight performance has not been established for this design, the CSR predictions for this O-ring are conservative relative to leak-tight performance. Based on the collective data developed to date, SRNL has recommended that the maintenance interval for the H1616 package be extended from 1 year to 2 years. Future recommendations in support of even longer maintenance intervals are expected, as additional aging data become available.

36 MATERIALS SCIENCE↗

SRNL Training Courses for Packaging, Transportation, and Storage of Radioactive Material - 17597

The U.S. Department of Energy (DOE) Packaging Certification Program (PCP), Office of Packaging and Transportation has sponsored a suite of training courses that have been conducted since the early 1990s. Of these training courses, the Savannah River National Laboratory (SRNL) is currently leading the effort for two courses: (1) Management of SARP Preparation, and (2) Nuclear and Other Radioactive Materials Transport Security and Leak Testing. This paper provides an overview of both courses. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Test Report of Special Form Qualification Testing for the ORNL U ZipCan

This test report describes the special form testing activities performed on the two ZiPCans. One prototype test unit was subjected to the tests stipulated by 10 CFR 71.75 (d)(1)(i), ISO 2919:1999(E) Class 4 impact test, along with the leak rate test specified in 49 CFR 173.469(a)(4)(i). The other test unit was subjected to a leak rate test as specified in 173.469(a)(4)(i) and a heat test as specified in 49 CFR 173.469 (b)(4). Each test unit was leak tested before and after these respective tests. The leak rate tests performed were helium back-pressure tests and bubble tests, as specified in ANSI N14.5-2014.The measured leak rates were converted to standard condition leak rates as specified in ASTM E 493. The determined standardized leak rates from the test and calculation for both test units met the requirements for special form certification.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pulsed Magnetic Welding for Advanced Core and Cladding Steel

To investigate a solid-state joining method, pulsed magnetic welding (PMW), for welding the advanced core and cladding steels to be used in Generation IV systems, with a specific application for fuel pin end-plug welding. As another alternative solid state welding technique, pulsed magnetic welding (PMW) has not been extensively explored on the advanced steels. The resultant weld can be free from microstructure defects (pores, non-metallic inclusions, segregation of alloying elements). More specifically, the following objectives are to be achieved: 1. To design a suitable welding apparatus fixture, and optimize welding parameters for repeatable and acceptable joining of the fuel pin end-plug. The welding will be evaluated using tensile tests for lap joint weldments and helium leak tests for the fuel pin end-plug; 2 Investigate the microstructural and mechanical properties changes in PMW weldments of proposed advanced core and cladding alloys; 3. Simulate the irradiation effects on the PWM weldments using ion irradiation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Type B package for the transport of large medical and industrial sources

AREVA Federal Services LLC, under contract to the Los Alamos National Laboratory's Offsite Source Recovery Project, is developing a new Type B(U)-96 package for the transport of unwanted or abandoned high activity gamma and neutron radioactive sealed sources (sources). The sources were used primarily in medical or industrial devices, and are of domestic (USA) or foreign origin. To promote public safety and mitigate the possibility of loss or misuse, the Offsite Source Recovery Project is recovering and managing sources worldwide. The package, denoted the LANL-B, is designed to accommodate the sources within an internal gamma shield. The sources are located either in the IAEA's Long Term Storage Shield (LTSS), or within intact medical or industrial irradiation devices. As the sources are already shielded separately, the package does not include any shielding of its own. A particular challenge in the design of the LANL-B has been weight. Since the LTSS shield weighs approximately 5,000 lb [2,270 kg], and the total package gross weight must be limited to 10,000 lb [4,540 kg], the net weight of the package was limited to 5,000 lb, for an efficiency of 50% (i.e., the payload weight is 50% of the gross weight of the package). This required implementation of a light-weight bell-jar concept, in which the containment takes the form of a vertical bell which is bolted to a base. A single impact limiter is used on the bottom, to protect the elastomer seals and bolted joint. A top-end impact is mitigated by the deformation of a tori spherically-shaped head. Impacts in various orientations on the bottom end are mitigated by a cylindrical, polyurethane foam-filled impact limiter. Internally, energy is absorbed using honeycomb blocks at each end, which fill the torispherical head volumes. As many of the sources are considered to be in normal form, the LANL-B package offers leak-tight containment using an elastomer seal at the joint between the bell and the base, as well as on the single vent port. Leak testing prior to transport may be either using helium mass spectrometry or the pressure-rise concept.

07 ISOTOPE AND RADIATION SOURCES↗

AGING BEHAVIOR OF VITON O-RING SEALS IN THE 9975 SHIPPING PACKAGE

The Savannah River Site (SRS) is storing plutonium (Pu) materials in the K-Area Materials Storage (KAMS) facility. The Pu materials were packaged according to the DOE-STD-3013 standard and shipped to the SRS in Type B 9975 packages. The robust 9975 shipping package was not designed for long-term product storage, but it is a specified part of the storage configuration and the KAMS facility safety basis credits the 9975 design with containment. Within the 9975 package, nested stainless steel containment vessels are closed with dual O-ring seals based on Viton{reg_sign} GLT or GLT-S fluoroelastomer. The aging behavior of the O-ring compounds is being studied to provide the facility with advanced notice of nonconformance and to develop life prediction models. A combination of field surveillance, leak testing of surrogate fixtures aged at bounding service temperatures, and accelerated-aging methodologies based on compression stress-relaxation and oxygen consumption analysis is being used to evaluate seal performance. A summary of the surveillance program relative to seal aging behavior is presented.

36 MATERIALS SCIENCE↗

Thermal Analysis of a Pipe Over-pack Container with a Combustible Waste Matrix for Los Alamos National Laboratory - 17307

Los Alamos National Laboratory (LANL) Technical Area 55 (TA 55) utilizes several different container types to store and transfer special nuclear material and waste for numerous programs. The Nuclear Process Infrastructure - Infrastructure Operations Group (NPI-2) analyzes and certifies containers to meet the specifications for distinct processes and storage. Engineering analysis performed on these containers include but are not limited to: leak testing, filter efficiency testing, pressure drop test, drop testing, water penetration testing, polymer (o-ring) hardness testing, and thermal steady state testing. Of all of these tests, thermal steady-state testing is most crucial to ensure critical components for specific containers do not fail under an internal heat payload. This testing provides data for setting heat payload limits for different containers. The Pipe Over-pack Container (POC) is a vented carbon steel container with a removable lid designed for storing or transferring nuclear waste. Additionally, TA 55 has been tasked to manage and store all of its Transuranic (TRU) waste for the foreseeable future. Being able to place more material into a single container conserves the physical storage space available at TA 55. The Pipe Over pack Handling and Operations Manual requires each user to ensure that the maximum temperature of each component in the POC is not exceeded. Conducting a thermal steady-state test with a combustible waste matrix on the POC can benefit stakeholders on increasing the material limits of the container. The results of these measurements will establish new wattage limits to meet LANL's transportation requirements. The current LANL Transportation Safety Document (TSD) limits the amount of heat source plutonium to 10 grams per POC, corresponding to approximately 5 Watts of heat. The result of this test was provided to the Packaging and Transportation (OS-PT) group to evaluate new wattage limits that can satisfy the needs of TA 55, while maintaining a safe packaging configuration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗