Search NASA⌕ Search

SEARCH · Search NASA

Results for “Library”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Fluorescent amplification for next generation sequencing (FA-NGS) library preparation

BACKGROUND: Next generation sequencing (NGS) has become a universal practice in modern molecular biology. As the throughput of sequencing experiments increases, the preparation of conventional multiplexed libraries becomes more labor intensive. Conventional library preparation typically requires quality control (QC) testing for individual libraries such as amplification success evaluation and quantification, none of which occur until the end of the library preparation process. RESULTS: In this study, we address the need for a more streamlined high-throughput NGS workflow by tethering real-time quantitative PCR (qPCR) to conventional workflows to save time and implement single tube and single reagent QC. We modified two distinct library preparation workflows by replacing PCR and quantification with qPCR using SYBR Green I. qPCR enabled individual library quantification for pooling in a single tube without the need for additional reagents. Additionally, a melting curve analysis was implemented as an intermediate QC test to confirm successful amplification. Sequencing analysis showed comparable percent reads for each indexed library, demonstrating that pooling calculations based on qPCR allow for an even representation of sequencing reads. To aid the modified workflow, a software toolkit was developed and used to generate pooling instructions and analyze qPCR and melting curve data. CONCLUSIONS: We successfully applied fluorescent amplification for next generation sequencing (FA-NGS) library preparation to both plasmids and bacterial genomes. As a result of using qPCR for quantification and proceeding directly to library pooling, the modified library preparation workflow has fewer overall steps. Therefore, we speculate that the FA-NGS workflow has less risk of user error. The melting curve analysis provides the necessary QC test to identify and troubleshoot library failures prior to sequencing. While this study demonstrates the value of FA-NGS for plasmid or gDNA libraries, we speculate that its versatility could lead to successful application across other library types.

59 BASIC BIOLOGICAL SCIENCES↗

Production and Testing of the VITAMIN-B7 Fine-Group and BUGLE-B7 Broad-Group Coupled Neutron/Gamma Cross-Section Libraries Derived from ENDF/B-VII.0 Nuclear Data

New coupled neutron-gamma cross-section libraries have been developed for use in light water reactor (LWR) shielding applications, including pressure vessel dosimetry calculations. The libraries, which were generated using Evaluated Nuclear Data File/B Version VII Release 0 (ENDF/B-VII.0), use the same fine-group and broad-group energy structures as the VITAMIN-B6 and BUGLE-96 libraries. The processing methodology used to generate both libraries is based on the methods used to develop VITAMIN-B6 and BUGLE-96 and is consistent with ANSI/ANS 6.1.2. The ENDF data were first processed into the fine-group pseudo-problem-independent VITAMIN-B7 library and then collapsed into the broad-group BUGLE-B7 library. The VITAMIN-B7 library contains data for 391 nuclides. This represents a significant increase compared to the VITAMIN-B6 library, which contained data for 120 nuclides. The BUGLE-B7 library contains data for the same nuclides as BUGLE-96, and maintains the same numeric IDs for those nuclides. The broad-group data includes nuclides which are infinitely dilute and group collapsed using a concrete weighting spectrum, as well as nuclides which are self-shielded and group collapsed using weighting spectra representative of important regions of LWRs. The verification and validation of the new libraries includes a set of critical benchmark experiments, a set of regression tests that are used to evaluate multigroup crosssection libraries in the SCALE code system, and three pressure vessel dosimetry benchmarks. Results of these tests confirm that the new libraries are appropriate for use in LWR shielding analyses and meet the requirements of Regulatory Guide 1.190.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of High Throughput Process for Constructing 454 Titanium and Illumina Libraries

We have developed two processes with the Biomek FX robot to construct 454 titanium and Illumina libraries in order to meet the increasing library demands. All modifications in the library construction steps were made to enable the adaptation of the entire processes to work with the 96-well plate format. The key modifications include the shearing of DNA with Covaris E210 and the enzymatic reaction cleaning and fragment size selection with SPRI beads and magnetic plate holders. The construction of 96 Titanium libraries takes about 8 hours from sheared DNA to ssDNA recovery. The processing of 96 Illumina libraries takes less time than that of the Titanium library process. Although both processes still require manual transfer of plates from robot to other work stations such as thermocyclers, these robotic processes represent about 12- to 24-folds increase of library capacity comparing to the manual processes. To enable the sequencing of many libraries in parallel, we have also developed sets of molecular barcodes for both library types. The requirements for the 454 library barcodes include 10 bases, 40-60percent GC, no consecutive same base, and no less than 3 bases difference between barcodes. We have used 96 of the resulted 270 barcodes to construct libraries and pool to test the ability of accurately assigning reads to the right samples. When allowing 1 base error occurred in the 10 base barcodes, we could assign 99.6percent of the total reads and 100percent of them were uniquely assigned. As for the Illumina barcodes, the requirements include 4 bases, balanced GC, and at least 2 bases difference between barcodes. We have begun to assess the ability to assign reads after pooling different number of libraries. We will discuss the progress and the challenges of these scale-up processes.

59 BASIC BIOLOGICAL SCIENCES↗

Outreach to Scientists and Engineers at the Hanford Technical Library

Staff at the Hanford Technical Library has developed a suite of programs designed to help busy researchers at the Pacific Northwest National Laboratory (PNNL) make better use of library products and services. Programs include formal training classes, one-on-one consultations, and targeted email messages announcing new materials to researchers in specific fields. A staple of outreach has been to teach classes to library clients covering research tools in their fields. These classes started out in the library classroom and then expanded to other venues around PNNL. Class surveys indicated that many researchers desired a practical approach to learning rather than the traditional lecture format. The library instituted “Library Learning Day” and hosted classes in the PNNL computer training room to provide lab employees with a hands-on learning experience. Classes are generally offered at noon and lab staff attends classes on their lunch hour. Many just do not have time to spend a full hour in training. Library staff added some experimental half-hour mini classes in campus buildings geared to the projects and interests of researchers there to see if this format was more appealing. As other programs have developed librarians are teaching fewer classes but average attendance figures has remained fairly stable from 2005-2007. In summer of 2004 the library began the Traveling Librarian program. Librarians call-on groups and individuals in 24 buildings on the Richland Washington campus. Five full-time and two part-time librarians are involved in the program. Librarians usually send out email announcements prior to visits and encourage scientists and engineers to make appointments for a brief 15 minute consultation in the researcher’s own office. During the meeting lab staff learn about products or product features that can help them work more productively. Librarians also make cold calls to staff that do not request a consultation and may not be making full use of the library. Scientists and engineers who require longer sessions can arrange half-hour training appointments in the researcher’s own office or at the library. Since the program was implemented staff made 165 visits to 1249 laboratory staff including some repeat consultation requests. New acquisitions lists are sent to individuals and groups that would be interested in recent journal, database, and books purchases. These lists are topic specific and targeted to groups and individuals with an interest in the field. For example newly acquired engineering resources are targeted at engineering groups. The new acquisitions list for engineering began mid year in 2005. An analysis of circulation statistics for engineering books in fiscal year 2005, 2006, and 2007 show that circulation increased each year with 2007 circulation nearly double that of 2005. This took place when overall circulation rose in FY06 but fell slightly in FY07. Outreach strategies tailored and individualized can be effective. Offering multiple outreach options offers researchers different ways to interact with library staff and services.

99 GENERAL AND MISCELLANEOUS↗

Patching EAF-2010 into CINDER2008 Cross Section Libraries

CINDER2008 [1] comes with multi-group cross section libraries using most recent evaluated cross section data. The multi-group cross sections are weighted with three spectra: fission, fusion and flat. However, due to data format incompatibilities with the CINDER2008library maker tool, many of the reaction cross sections adapted from EAF-2010 [2] are either truncated or completely missing. Therefore it is essential to regenerate the CINDER2008 libraries with compatible EAF-2010 data. The updated cross section libraries are compared to those of the current cross section libraries in the sections below following a brief introduction of the CINDER2008 cross section libraries and a description of the method of generating cross sections for the CINDER2008 code. In the remainder of this document, we will refer to the libraries distributed with CINDER2008before October 2016 as the "current" libraries, and those described in this work as the "updated" libraries. In figures, the current library data may be shown with the library namewith or without “cur” appended, while the updated library data may be shown with "mod" appended.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

OVERVIEW OF THE 2009 RELEASE OF THE EVALUATED NUCLEAR DATA LIBRARY (ENDL2009)

The Lawrence Livermore National Laboratory (LLNL) Physics Division has produced the next iteration of LLNL's evaluated nuclear database, ENDL2009. ENDL2009 is the second in a series of major ENDL library releases designed to support LLNL's current and future nuclear data needs. This library includes 585 distinct transport-ready evaluations in the neutron sub-library and many physics improvements for stockpile stewardship, attribution signatures, key radiochemical diagnostics and performance of conventional and hybrid fission/fusion reactors. In building this library, we adopted the best of the world's nuclear data efforts: 46% of the library is from the ENDF/B-VII.0 library, 10% is from the JENDL libraries and 8% from other libraries. The remaining 36% of the neutron sub-library and all of the charged-particle sub-libraries consist of new evaluations developed at LLNL for the ENDL2009 library. In addition, ENDL2009 supports new features such as energy-dependent Q values from fission, support for unresolved resonances and average momentum deposition. Finally, this release is our most highly tested release as we have strengthened our already rigorous testing regime by adding tests against LANL Activation Ratio Measurements and more than 1200 new critical assemblies. Our testing is now being incorporated into our development process and is serving to guide database improvements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimization of reference library used in content-based medical image retrieval scheme

Building an optimal image reference library is a critical step in developing the interactive computer-aided detection and diagnosis (I-CAD) systems of medical images using content-based image retrieval (CBIR) schemes. In this study, the authors conducted two experiments to investigate (1) the relationship between I-CAD performance and size of reference library and (2) a new reference selection strategy to optimize the library and improve I-CAD performance. The authors assembled a reference library that includes 3153 regions of interest (ROI) depicting either malignant masses (1592) or CAD-cued false-positive regions (1561) and an independent testing data set including 200 masses and 200 false-positive regions. A CBIR scheme using a distance-weighted K-nearest neighbor algorithm is applied to retrieve references that are considered similar to the testing sample from the library. The area under receiver operating characteristic curve (A{sub z}) is used as an index to evaluate the I-CAD performance. In the first experiment, the authors systematically increased reference library size and tested I-CAD performance. The result indicates that scheme performance improves initially from A{sub z}=0.715 to 0.874 and then plateaus when the library size reaches approximately half of its maximum capacity. In the second experiment, based on the hypothesis that a ROI should be removed if it performs poorly compared to a group of similar ROIs in a large and diverse reference library, the authors applied a new strategy to identify 'poorly effective' references. By removing 174 identified ROIs from the reference library, I-CAD performance significantly increases to A{sub z}=0.914 (p<0.01). The study demonstrates that increasing reference library size and removing poorly effective references can significantly improve I-CAD performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Constructing high complexity synthetic libraries of long ORFs using in vitro selection

We present a method that can significantly increase the complexity of protein libraries used for in vitro or in vivo protein selection experiments. Protein libraries are often encoded by chemically synthesized DNA, in which part of the open reading frame is randomized. There are, however, major obstacles associated with the chemical synthesis of long open reading frames, especially those containing random segments. Insertions and deletions that occur during chemical synthesis cause frameshifts, and stop codons in the random region will cause premature termination. These problems can together greatly reduce the number of full-length synthetic genes in the library. We describe a strategy in which smaller segments of the synthetic open reading frame are selected in vitro using mRNA display for the absence of frameshifts and stop codons. These smaller segments are then ligated together to form combinatorial libraries of long uninterrupted open reading frames. This process can increase the number of full-length open reading frames in libraries by up to two orders of magnitude, resulting in protein libraries with complexities of greater than 10(13). We have used this methodology to generate three types of displayed protein library: a completely random sequence library, a library of concatemerized oligopeptide cassettes with a propensity for forming amphipathic alpha-helical or beta-strand structures, and a library based on one of the most common enzymatic scaffolds, the alpha/beta (TIM) barrel. Copyright 2000 Academic Press.

Non-NASA Center↗

LibraryX: A Framework for Cross-Library-Call Optimization

Scientific applications utilize performance libraries as a software engineering concept: these libraries encapsulate important and well-understood (mathematical) operations, allow for reuse, and are implemented and tuned by experts. Domain scientists then implement complex algorithms based on these domainspecific libraries. While individual library calls are optimized, larger performance gains across sequences of calls—sometimes spanning multiple libraries—are often unrealized, forcing a trade-off between performance and implementation complexity.To overcome this issue, we propose LibraryX, an approach and a system that allows for cross-library-call optimization even when library calls stem from multiple performance libraries. LibraryX annotates library calls with semantic information and optimizes entire directed acyclic graphs (DAGs) of calls dynamically using the SPIRAL code generation system. We demonstrate its effectiveness across a range of memory bound workloads, achieving significant speedups on Nvidia, AMD, and Intel accelerators compared to code using native libraries without cross-call optimization.

Rao, Sanil [Carnegie Mellon University,Department ↗

Trinucleotide cassettes increase diversity of T7 phage-displayed peptide library

Background: Amino acid sequence diversity is introduced into a phage-displayed peptide library by randomizing library oligonucleotide DNA. We recently evaluated the diversity of peptide libraries displayed on T7 lytic phage and M13 filamentous phage and showed that T7 phage can display a more diverse amino acid sequence repertoire due to differing processes of viral morphogenesis. Methods: In this study, we evaluated and compared the diversity of a 12-mer T7 phage-displayed peptide library randomized using codon-corrected trinucleotide cassettes with a T7 and an M13 12-mer phage-displayed peptide library constructed using the degenerate codon randomization method. Results: We herein demonstrate that the combination of trinucleotide cassette amino acid codon randomization and T7 phage display construction methods resulted in a significant enhancement to the functional diversity of a 12-mer peptide library. This novel library exhibited superior amino acid uniformity and order-of-magnitude increases in amino acid sequence diversity as compared to degenerate codon randomized peptide libraries. Comparative analyses of the biophysical characteristics of the 12-mer peptide libraries revealed the trinucleotide cassette-randomized library to be a unique resource. Conclusion: The combination of T7 phage display and trinucleotide cassette randomization resulted in a novel resource for the potential isolation of binding peptides for new and previously studied molecular targets.

59 BASIC BIOLOGICAL SCIENCES↗

CHEMICAL EVOLUTION LIBRARY FOR GALAXY FORMATION SIMULATION

We have developed a software library for chemical evolution simulations of galaxy formation under the simple stellar population (SSP) approximation. In this library, all of the necessary components concerning chemical evolution, such as initial mass functions, stellar lifetimes, yields from Type II and Type Ia supernovae, asymptotic giant branch stars, and neutron star mergers, are compiled from the literature. Various models are pre-implemented in this library so that users can choose their favorite combination of models. Subroutines of this library return released energy and masses of individual elements depending on a given event type. Since the redistribution manner of these quantities depends on the implementation of users’ simulation codes, this library leaves it up to the simulation code. As demonstrations, we carry out both one-zone, closed-box simulations and 3D simulations of a collapsing gas and dark matter system using this library. In these simulations, we can easily compare the impact of individual models on the chemical evolution of galaxies, just by changing the control flags and parameters of the library. Since this library only deals with the part of chemical evolution under the SSP approximation, any simulation codes that use the SSP approximation—namely, particle-base and mesh codes, as well as semianalytical models—can use it. This library is named “CELib” after the term “Chemical Evolution Library” and is made available to the community.

79 ASTRONOMY AND ASTROPHYSICS↗

Architectural Optimization of Digital Libraries

This work investigates performance and scaling issues relevant to large scale distributed digital libraries. Presently, performance and scaling studies focus on specific implementations of production or prototype digital libraries. Although useful information is gained to aid these designers and other researchers with insights to performance and scaling issues, the broader issues relevant to very large scale distributed libraries are not addressed. Specifically, no current studies look at the extreme or worst case possibilities in digital library implementations. A survey of digital library research issues is presented. Scaling and performance issues are mentioned frequently in the digital library literature but are generally not the focus of much of the current research. In this thesis a model for a Generic Distributed Digital Library (GDDL) and nine cases of typical user activities are defined. This model is used to facilitate some basic analysis of scaling issues. Specifically, the calculation of Internet traffic generated for different configurations of the study parameters and an estimate of the future bandwidth needed for a large scale distributed digital library implementation. This analysis demonstrates the potential impact a future distributed digital library implementation would have on the Internet traffic load and raises questions concerning the architecture decisions being made for future distributed digital library designs.

Biser, Aileen O.↗

Generation of the V4.2m5 and AMPX and MPACT 51 and 252-Group Libraries with ENDF/B-VII.0 and VII.1

The evaluated nuclear data file (ENDF)/B-7.0 v4.1m3 MPACT 47-group library has been used as a main library for the Consortium for Advanced Simulation of Light Water Reactors (CASL) neutronics simulator in simulating pressurized water reactor (PWR) problems. Recent analysis for the high void boiling water reactor (BWR) fuels and burnt fuels indicates that the 47-group library introduces relatively large reactivity bias. Since the 47- group structure does not match with the SCALE 6.2 252-group boundaries, the CASL Virtual Environment for Reactor Applications Core Simulator (VERA-CS) MPACT library must be maintained independently, which causes quality assurance concerns. In order to address this issue, a new 51-group structure has been proposed based on the MPACT 47- g and SCALE 252-g structures. In addition, the new CASL library will include a 19-group structure for gamma production and interaction cross section data based on the SCALE 19- group structure. New AMPX and MPACT 51-group libraries have been developed with the ENDF/B-7.0 and 7.1 evaluated nuclear data. The 19-group gamma data also have been generated for future use, but they are only available on the AMPX 51-g library. In addition, ENDF/B-7.0 and 7.1 MPACT 252-g libraries have been generated for verification purposes. Various benchmark calculations have been performed to verify and validate the newly developed libraries.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A novel lentiviral scFv display library for rapid optimization and selection of high affinity antibodies

Highlights: • We constructed a novel scFv display library based on lentivirus vector. • Stable transduced cell lines were obtained. • Characterization of mutants showed approximately upto three fold increase in antibody affinity. Antibody display libraries have become a popular technique to screen monoclonal antibodies for therapeutic purposes. An important aspect of display technology is to generate an optimization library by changing antibody affinity to antigen through mutagenesis and screening the high affinity antibody. In this study, we report a novel lentivirus display based optimization library antibody in which Agtuzumab scFv is displayed on cell membrane of HEK-293T cells. To generate an optimization library, hotspot mutagenesis was performed to achieve diverse antibody library. Based on sequence analysis of randomly selected clones, library size was estimated approximately to be 1.6 × 10{sup 6}. Lentivirus display vector was used to display scFv antibody on cell surface and flow cytometery was performed to check the antibody affinity to antigen. Membrane bound scFv antibodies were then converted to secreted antibody through cre/loxP recombination. One of the mutant clones, M8 showed higher affinity to antigen in flow cytometery analysis. Further characterization of cellular and secreted scFv through western blot showed that antibody affinity was increased by three fold after mutagenesis. This study shows successful construction of a novel antibody library and suggests that hotspot mutagenesis could prove a useful and rapid optimization tool to generate similar libraries with various degree of antigen affinity.

60 APPLIED LIFE SCIENCES↗

DeCOIL: Optimization of Degenerate Codon Libraries for Machine Learning-Assisted Protein Engineering

With advances in machine learning (ML)-assisted protein engineering, models based on data, biophysics, and natural evolution are being used to propose informed libraries of protein variants to explore. Synthesizing these libraries for experimental screens is a major bottleneck, as the cost of obtaining large numbers of exact gene sequences is often prohibitive. Degenerate codon (DC) libraries are a cost-effective alternative for generating combinatorial mutagenesis libraries where mutations are targeted to a handful of amino acid sites. However, existing computational methods to optimize DC libraries to include desired protein variants are not well suited to design libraries for ML-assisted protein engineering. To address these drawbacks, we present DEgenerate Codon Optimization for Informed Libraries (DeCOIL), a generalized method which directly optimizes DC libraries to be useful for protein engineering: to sample protein variants that are likely to have both high fitness and high diversity in the sequence search space. Using computational simulations and wet-lab experiments, we demonstrate that DeCOIL is effective across two specific case studies, with potential to be applied to many other use cases. DeCOIL offers several advantages over existing methods, as it is direct, easy-to-use, generalizable, and scalable. With accompanying software, DeCOIL can be readily implemented to generate desired informed libraries.

59 BASIC BIOLOGICAL SCIENCES↗

A Robust and Versatile Method of Combinatorial Chemical Synthesis of Gene Libraries via Hierarchical Assembly of Partially Randomized Modules

A major challenge in gene library generation is to guarantee a large functional size and diversity that significantly increases the chances of selecting different functional protein variants. The use of trinucleotides mixtures for controlled randomization results in superior library diversity and offers the ability to specify the type and distribution of the amino acids at each position. Here we describe the generation of a high diversity gene library using tHisF of the hyperthermophile Thermotoga maritima as a scaffold. Combining various rational criteria with contingency, we targeted 26 selected codons of the thisF gene sequence for randomization at a controlled level. We have developed a novel method of creating full-length gene libraries by combinatorial assembly of smaller sub-libraries. Full-length libraries of high diversity can easily be assembled on demand from smaller and much less diverse sublibraries, which circumvent the notoriously troublesome long-term archivation and repeated proliferation of high diversity ensembles of phages or plasmids. We developed a generally applicable software tool for sequence analysis of mutated gene sequences that provides efficient assistance for analysis of library diversity. Finally, practical utility of the library was demonstrated in principle by assessment of the conformational stability of library members and isolating protein variants with HisF activity from it. Our approach integrates a number of features of nucleic acids synthetic chemistry, biochemistry and molecular genetics to a coherent, flexible and robust method of combinatorial gene synthesis.

59 BASIC BIOLOGICAL SCIENCES↗

MT71x: Multi-Temperature Library Based on ENDF/B-VII.1

The Nuclear Data Team has released a multitemperature transport library, MT71x, based upon ENDF/B-VII.1 with a few modifications as well as additional evaluations for a total of 427 isotope tables. The library was processed using NJOY2012.39 into 23 temperatures. MT71x consists of two sub-libraries; MT71xMG for multigroup energy representation data and MT71xCE for continuous energy representation data. These sub-libraries are suitable for deterministic transport and Monte Carlo transport applications, respectively. The SZAs used are the same for the two sub-libraries; that is, the same SZA can be used for both libraries. This makes comparisons between the two libraries and between deterministic and Monte Carlo codes straightforward. Both the multigroup energy and continuous energy libraries were verified and validated with our checking codes checkmg and checkace (multigroup and continuous energy, respectively) Then an expanded suite of tests was used for additional verification and, finally, verified using an extensive suite of critical benchmark models. We feel that this library is suitable for all calculations and is particularly useful for calculations sensitive to temperature effects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Software Quality Assurance and Verification for the MPACT Library Generation Process

This report fulfills the requirements for the Consortium for the Advanced Simulation of Light-Water Reactors (CASL) milestone L2:RTM.P14.02, “SQA and Verification for MPACT Library Generation,” by documenting the current status of the software quality, verification, and acceptance testing of nuclear data libraries for MPACT. It provides a brief overview of the library generation process, from general-purpose evaluated nuclear data files (ENDF/B) to a problem-dependent cross section library for modeling of light-water reactors (LWRs). The software quality assurance (SQA) programs associated with each of the software used to generate the nuclear data libraries are discussed; specific tests within the SCALE/AMPX and VERA/XSTools repositories are described. The methods and associated tests to verify the quality of the library during the generation process are described in detail. The library generation process has been automated to a degree to (1) ensure that it can be run without user intervention and (2) to ensure that the library can be reproduced. Finally, the acceptance testing process that will be performed by representatives from the Radiation Transport Methods (RTM) Focus Area prior to the production library’s release is described in detail.

97 MATHEMATICS AND COMPUTING↗