Search NASA⌕ Search

SEARCH · Search NASA

Results for “Limit of detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Characterization of Contaminants and Mobility in WMA A-AX Boreholes D0006 and D0008

This study was initiated to determine if subsurface contaminants in the A-AX vadose zone at the Hanford site (boreholes D0006 and D0008) caused corrosion of nearby stainless steel well casings (299-E-24-19, 299-E25-46, and 299-E25-236) and, based on the type and distribution of contaminants, determine if contaminants are from one or more sources including a) the A-104 and/or A-105 tanks, b) the 242A evaporator, and c) the 200-E-286 ditch. A tiered approach was used for characterizing contaminants in vadose zone sediments starting with mobile and total contaminant concentrations (Tier 1), characterizing contaminant speciation (Tier 2), and measuring contaminant leaching (Tier 3). Total and mobile contaminant measurements at seven depths showed elevated sulfate and nitrate in all samples (130 to 280 ft depth), elevated chloride in five depths, and no elevated radionuclides except I-129 in D0006 at 206 to 208 ft depth. If these contaminants were initially acidic, stainless-steel corrosion would occur. However, because sediments likely have a high acid neutralization capacity, an acidic spill would have been neutralized within tens of feet, so casing corrosion would likely occur in shallow sediments. GEL labs data also shows low (but above natural) chromate from shallow to 170 ft depth, then higher chromate to 280 ft, suggesting a surface Cr spill or casing corrosion. GEL labs data also showed evidence of more than one plume, with deep nitrate, sulfate, and chloride migration, but only shallow tritium migration. Tritium should migrate nearly unretarded in the subsurface like nitrate and chloride. Elevated aqueous cations and anions in the D0006 206 to 208' depth pore water (SO 4 2- , NO 3 - , Na + , K + , Ca 2+ , Mg 2+ , Si) could be the result of acid disposal and calcite dissolution at shallow depth, with deeper migration of SO 4 2- , NO 3 - from acids and Ca 2+ and Mg 2+ from calcite. Elevated Si (160 mg/L) indicates dissolution of clays or other silicates, which can also occur in acids. Acid extractable metals did show elevated Cr (but not Fe, Ni, Mo, and Mn) above natural levels, which may indicate stainless-steel well corrosion or transport of metals from a shallow spill. The elevated I-129 in D0006 at 206 to 208' depth was low with 0.34 μg/g in pore water and 1.5 μg/g total extractable I-129 in the sediment, which indicates significant fraction of I-129 was bound in one or more precipitates. Although total I-129 was below detection limits in most extractions due to high molybdate interference, I-127 analysis provided some insight into potential precipitate phases. Total I-127 was mainly extracted by acetate or acetic acid (67%), which may be iodine in calcite. Inorganic carbon measurement identified 1.65% calcite, and total organic carbon (TOC) was below detection limits, so iodine was not associated with organic matter. Nearly all the I-127 was present as iodide. In 1-D leach experiments, I-127 as iodide leached from the sediment within 2 pore volumes. Due to high and dynamic molybdate leaching from the sediment and interference with I-129 analysis, there were few quantifiable I-129 measurements. The calculated molybdate release rates from the sediment suggested Mo was being released from the same precipitate phase, such as molybdate incorporated into calcite. Overall, because there was little radioactive contamination measured in D0006 and D0008 boreholes, potential releases from A-104 and A-105 did not reach this location south of the A tank farm. Elevated cations and anions found in D0006 and D0008 at depth as the result of acidic disposal could cause shallow stainless steel casing corrosion. The nearby 242A evaporator generally contained alkaline waste and tritium, but the nearby 200-E-286 ditch generally contained high Cl - liquid effluent, so these are unlikely to be acidic sources.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Erosion of tungsten marker layers in W7-X

In order to get first insight into net tungsten erosion in W7-X, tungsten (W) marker layers were exposed during the operational phase OP 1.2b at one position of the Test Divertor Unit (TDU), at 21 different positions of the inner heat shield, and at two scraper elements. The maximum tungsten erosion rate at the TDU strike line was 0.13 nm s -1 averaged over the whole campaign. The erosion was inhomogeneous on a microscopic scale, with higher erosion on ridges of the rough surface inclined towards the plasma and deposition of hydrocarbon layers in the recessed areas of the rough surface. The W erosion at the inner heat shield was below the detection limit of 3–6 × 10 12 W-atoms/cm 2 s, and all inner heat shield tiles were covered with a thin B/C/O layer with thickness in the range 2 × 10 17 –10 18 B + C atoms/cm 2 (about 20–100 nm B + C). W-erosion of the marker layers on the scraper elements was also below the detection limit.

Mayer, M↗

Survey of Technologies to Meet PAG limits for Detection of Cesium-137 in Water

The goal of this report is to evaluate the process of adding a sorbent to the sampling process to preconcentrate Cs-137 and then analyze the sorbent to provide a rapid assessment of results to guide decisions on drinking water sources and the protection of the public. Multiple unit design variables were considered: sample configuration/geometry, sorbent efficiency, sample volume. Model simulations demonstrated through these unit design efficiencies that 10 L of sample volume processed through a sorbent provides nearly two orders of magnitude improvement in sample counting time to provide results to a decision maker than the current process. Over 60 publications and reports concerning Cs-137 and sorbents were evaluated. The key attributes were readiness of sorbent to be deployed in a mobile laboratory environment, and minimum sample preparation and conditioning. Examples of sorbents not considered further included nanomaterials, which have not been evaluated at a commercial scale and are limited in availability. The recommended sorbents for further consideration include: ferrocyanide salts, zeolite, and chemically modified granular activated carbon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low Count and Background Radionuclides Analysis - 20488

The US Department of Energy (DOE) is often faced with the need to evaluate radionuclides at low concentrations. When site sample data are likely to be close to threshold activity concentrations of interest, then the means by which the radiochemical analysis is performed and reported is critical. This situation can occur when differentiating from zero (presence/absence) for radionuclides that do not occur naturally, close comparison with environmental background for naturally occurring radionuclides, close comparison with a risk- or dose-based threshold concentrations of interest, or even comparisons across studies. There are several analytical issues that are of concern, but the two that appear to cause incorrect decisions to be made most often involve establishing detection limits and subtracting ambient background conditions in the laboratory. These issues are not critical when radionuclide activity concentrations are large relative to thresholds of concern, but they seem to be poorly understood when it matters. When the comparisons are important and are likely to be close to a threshold of interest, then the general contract with the analytical laboratories needs to be changed so that the right or appropriate data are obtained. The concern is that important decisions are made incorrectly more often as greater scrutiny is placed on DoE's radionuclide cleanup or monitoring decisions by the public and other stakeholders. Examples are presented of problems that have been observed for different projects, both within and outside the realm of DOE and NRC remediation and radioactive waste disposal problems, and solutions are offered that should lead to better data from which important decisions need to be made. The first example is from Los Alamos National Laboratory (LANL) and involves radionuclide concentrations in soil and rock beneath LANL's Material Disposal Area (MDA) G. An initial review of the data led to a conclusion that americium and plutonium are a long way present beneath MDA G. A more thorough review of the data that accounted properly for ambient background and the detection limits that had been established led to the opposite conclusion. Another example is from the Nevada National Security Site where tritium results from one of the wells were unexpectedly high. Proper understanding and analysis of ambient background led to the conclusion that the increased concentrations were not so obvious, and that a different contract with the analytical laboratory was needed to provide more appropriate data to support a better determination. Other examples are used from regulatory review of projects in Nevada, where background levels and secular equilibrium for naturally occurring radionuclides are not established correctly because of analytical issues. The same basic issues have also been found to create difficulties analyzing historical data from the West Valley Demonstration Project. There is evidence in the data that the apparent lack of secular equilibrium where it is expected to exist is related to ambient background subtraction or other analytical issues. A final example is presented for analysis of Tc-99 in samples of depleted uranium. In this case, two different studies that were performed only three months apart provide quite different results. The US Environmental Protection Agency (EPA) established the data quality objectives (DQO) process in the mid-1980's to establish decision performance criteria for data collection. EPA guidance (EPA G-4, for example) clearly distinguishes between DQOs and measurement performance objectives (MQOs) that should be addressed for laboratory analysis of samples. The language of DQOs and MQOs has become confused over time it seems, and the subsequent effects seem to include a lack of attention to decision performance and a routine approach to measurement quality. In order to better address radionuclide sample analysis when the concentrations are close to thresholds of concern, which might be zero for some radionuclides, background for others, and risk-based thresholds for yet others, it is important that routine laboratory analysis methods are adjusted, and that the project team and the laboratory work closely together to ensure that the data meets the MQO requirements of laboratory analysis and reporting of results, and that the MQOs effectively support project-specific DQOs. This basic approach will be applied in Los Alamos in the coming year to the collection of moisture data from underneath MDA T that will be analyzed for americium and neptunium isotopes. Proper understanding of the radiochemistry methods and reporting, and of appropriate statistical methods is critical to the success of such projects, ensuring that the right decisions are made. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Nitrogen fixation rates in the Guinea Dome and the equatorial upwelling regions in the Atlantic Ocean

Abstract Biological nitrogen fixation is a key process balancing the loss of combined nitrogen in the marine nitrogen cycle. Its relevance in upwelling or high nutrient regions is still unclear, with the few available studies in these regions of the ocean reporting rates that vary widely from below detection limit to > 100 nmol N L −1 d −1 . In the eastern tropical Atlantic Ocean, two open ocean upwelling systems are active in boreal summer. One is the seasonal equatorial upwelling, where the residual phosphorus associated with aged upwelled waters is suggested to enhance nitrogen fixation in this season. The other is the Guinea Dome, a thermal upwelling dome. We conducted two surveys along 23° W across the Guinea Dome and the Equator from 15° N to 5° S in September 2015 and August–September 2016 with high latitudinal resolution (20–60 nm between stations). The abundance of Trichodesmium colonies was characterized by an Underwater Vision Profiler 5 and the total biological nitrogen fixation in the euphotic layer was measured using the 15 N 2 technique. The highest abundances of Trichodesmium colonies were found in the area of the Guinea Dome (9°–15° N) with a maximum of 3 colonies L −1 near the surface. By contrast, colonies were almost absent in the Equatorial band between 2° N and 5° S. The highest nitrogen fixation rate was measured at the northern edge of the Guinea Dome in 2016 (ca. 31 nmol N L −1 d −1 ). In this region, where diazotrophs thrived on a sufficient supply of both phosphorus and iron, a patchy distribution was unveiled by our increased spatial resolution scheme. In the Equatorial band, rates were considerably lower, ranging from below detection limit to ca. 4 nmol N L −1 d −1 , with a clear difference in magnitude between 2015 (rates close to zero) and 2016 (average rates around 2 nmol N L −1 d −1 ). This difference seemed triggered by a contrasting supply of phosphorus between years. Our study stresses the importance of surveys with sampling at fine-scale spatial resolution, and shows unexpected high variability in the rates of nitrogen fixation in the Guinea Dome, a region where diazotrophy is a significant process supplying new nitrogen into the euphotic layer.

Fernández-Carrera, Ana (ORCID:0000000183470996)↗

Pushing the limits of detectability: mixed dark matter from strong gravitational lenses

One of the frontiers for advancing what is known about dark matter lies in using strong gravitational lenses to characterize the population of the smallest dark matter haloes. There is a large volume of information in strong gravitational lens images – the question we seek to answer is to what extent we can refine this information. To this end, we forecast the detectability of a mixed warm and cold dark matter scenario using the anomalous flux ratio method from strong gravitational lensed images. The halo mass function of the mixed dark matter scenario is suppressed relative to cold dark matter but still predicts numerous low-mass dark matter haloes relative to warm dark matter. Since the strong lensing signal receives a contribution from a range of dark matter halo masses and since the signal is sensitive to the specific configuration of dark matter haloes, not just the halo mass function, degeneracies between different forms of suppression in the halo mass function, relative to cold dark matter, can arise. Here, we find that, with a set of lenses with different configurations of the main deflector and hence different sensitivities to different mass ranges of the halo mass function, the different forms of suppression of the halo mass function between the warm dark matter model and the mixed dark matter model can be distinguished with 40 lenses with Bayesian odds of 30:1.

79 ASTRONOMY AND ASTROPHYSICS↗

Local limits of detection for anthropogenic aerosol-cloud interactions

Ship tracks are quasi-linear cloud patterns produced from the interaction of ship emissions with low boundary layer clouds. They are visible throughout the diurnal cycle in satellite images from space-borne assets like the Advanced Baseline Imagers (ABI) aboard the National Oceanic and Atmospheric Administration Geostationary Operational Environmental Satellites (GOES-R). However, complex atmospheric dynamics often make it difficult to identify and characterize the formation and evolution of tracks. Ship tracks have the potential to increase a cloud's albedo and reduce the impact of global warming. Thus, it is important to study these patterns to better understand the complex atmospheric interactions between aerosols and clouds to improve our climate models, and examine the efficacy of climate interventions, such as marine cloud brightening. Over the course of this 3-year project, we have developed novel data-driven techniques that advance our ability to assess the effects of ship emissions on marine environments and the risks of future marine cloud brightening efforts. The three main innovative technical contributions we will document here are a method to track aerosol injections using optical flow, a stochastic simulation model for track formations and an automated detection algorithm for efficient identification of ship tracks in large datasets.

54 ENVIRONMENTAL SCIENCES↗

Sodium Dodecyl Sulfate–Mediated Graphene Sensor for Electrochemical Detection of the Antibiotic Drug: Ciprofloxacin

The present study involves detecting and determining CIP by a new electrochemical sensor based on graphene (Gr) in the presence of sodium dodecyl sulfate (SDS) employing voltammetric techniques. Surface morphology studies of the sensing material were analyzed using a scanning electron microscope (SEM) and atomic force microscope (AFM). In the electroanalysis of CIP at the developed electrode, an enhanced anodic peak response was recorded, suggesting the electro-oxidation of CIP at the electrode surface. Furthermore, we evaluated the impact of the electrolytic solution, scan rate, accumulation time, and concentration variation on the electrochemical behavior of CIP. The possible electrode mechanism was proposed based on the acquired experimental information. A concentration variation study was performed using differential pulse voltammetry (DPV) in the lower concentration range, and the fabricated electrode achieved a detection limit of 2.9 × 10 -8 M. The proposed sensor detected CIP in pharmaceutical and biological samples. The findings displayed good recovery, with 93.8% for tablet analysis and 93.3% to 98.7% for urine analysis. The stability of a developed electrode was tested by inter- and intraday analysis.

36 MATERIALS SCIENCE↗

Vitrification of Hanford Tank 241-AP-101 Waste and Simulant

Hanford tank 241-AP-101 (referred to herein as AP-101) is the second Hanford radioactive tank waste planned to be processed and vitrified. A simulant version of AP 101 waste was formulated from the best-basis inventory (BBI) for the Hanford Tank 241-AP-101 liquid with an assumed target dilution of the waste from the BBI sodium molarity of 8.61 M to the desired 5.5 M Na. After the addition of glass-forming chemicals (GFCs), the simulant melter feed was processed in a non-radioactive, continuous laboratory-scale melter (CLSM) system. The AP-101 simulant melter feed was charged into the CLSM for 6.11 h of processing, which produced 6.55 kg of glass, for an average glass production rate of 2275 kg m 2 d -1 . Since there were no processing issues with the AP-101 simulant melter feed, AP-101 melter feed made with actual waste was then processed in a CLSM system built into a contamination area in a radioactive environment. The melting behavior characteristics appeared similar for both the simulant and waste melter feeds. The AP-101 waste melter feed was charged into the CLSM for 12.14 h of processing, which produced 8.75 kg of glass, for an average glass production rate of 1530 kg m 2 d -1 . During the AP-101 waste melter feed charging, the pump used to move the feed reached a maximum and it is believed that if the pump had a greater capacity, a greater average glass production rate could have been achieved. A constituent of interest present in low quantities in the AP-101 waste is 99 Tc or its non-radioactive surrogate, Re, added to the AP-101 simulant. Analysis for the quantities of 99 Tc and Re in the AP-101 glass product resulted in an average single-pass retention from the melter feed during relative chemical steady state of 55 ± 2 % for 99 Tc and 45 ± 2 % for Re. Compared to the processing of other melter feeds, the retention of 99 Tc in the AP-101 glass was greater than in both AP-107 and AP-105 glass, while the retention of Re in the AP-101 was less than in the AP-107 glass, but greater than in the AP-105 glass. A spike of I was added into the AP-101 melter feed that could be detected above the analysis detection limits. However, the iodine was only detectable above the ~6 ppm limit in one glass pour: the pour immediately following the burn off of the cold cap, where the I level reached ~30 ppm. This event was significant because the glass was poured immediately after burn off and thus it is presumed that the iodine had yet to volatilize from the glass melt while idling. It is recommended to perform future tests with I spikes at greater levels so that it can be detected in additional glass pours to determine if the expected 50 % retention of I used in the Kim et al. glass models can be confirmed. Offgas liquid samples were analyzed for acetonitrile, which was present at greater concentrations in CLSM liquids than in other scaled melter systems. This result was expected based on unique conditions with the CLSM system including a small plenum space leading to low residence time for offgas and the rapidity of offgas cooling upon exiting the CLSM vessel due to the location and environment. About 90 % of the total acetonitrile captured during both the AP-101 simulant and waste CLSM runs was found in the offgas condensate and demister liquids, thus it is recommended that only those liquids be sent for analysis if future testing to study the presence of acetonitrile in offgas products is desired.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantifying the Potential of Argon Detection Capabilities for Nuclear Explosion Monitoring

Abstract Current noble gas detection systems for nuclear explosion monitoring are based on the detection of four radioxenon isotopes—Xe-131m, -133, -133m and -135. The data provided by radioxenon detection could be enhanced by other radionuclide signatures such as Ar-37. Activation of Ca-40 in rock by neutrons produces Ar-37, and monitoring for this additional nuclide could help distinguish detections of nuclear explosions from background sources, such as medical isotope production. This work studies the capabilities of a hypothetical argon detection network. A 10 kt explosion was modeled using MCNP and SCALE to determine the inventory of Ar-37 created in a representative granite rock layer, assuming either 0.1, 1 or 10% of the total inventory was released. The Ar-37 inventory was combined with atmospheric transport data from HYSPLIT compiled in a previous study, along with the detection limits of standard Ar-37 detection systems, to determine how many hypothetical monitoring stations would detect Ar-37 from an explosion. This method was repeated for 365 HYSPLIT data sets to create a year’s worth of hypothetical explosions, releases, and detections. The study quantified the average number of detections per release, the number of stations detecting Ar-37, and the possibility of detecting Ar-37 in coincidence with xenon.

37Ar↗

Ultra low background time projection alpha particle detector ( Phase II Final Scientific/Technical Report)

When alpha particles are emitted into a gas they create an ionization track of gas ions and electrons. In our commercial UltraLo instrument we apply a voltage between a planar sample and an anode, integrate the anode signal as it collects the electrons, and distinguish between alphas emitted from the sample and elsewhere (anode, sidewalls) by the duration and shape of the resultant signal. The major contributors limiting the instrument’s lower detection limit are cosmic rays that pass through the detector close to the sample and Rn decays that produce charge tracks the originate in the gas and end on the sample. In this work we proposed to identify and reject these events by converting the anode into a multi-pixel array and operating in time projection mode. Cosmic rays would be eliminated by generating charge on many pixels, while charge collection asymmetry would distinguish between sample events (Bragg curve up) and Rn events (Bragg curve down). We therefore proposed to modify an UltraLo by pixilating its anode, developing low noise, low power multiplexed electronics to track each pixel’s signal individually, and develop analysis software to make the required discriminations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in PFAS Monitoring and Remediation Using a Functionalized Material Approach - 20080

The growing global concerns about the effects to public health from human exposure to per- and polyfluoroalkyl substances (PFAS) motivates the development of strategies for reliable monitoring of PFAS in environmental streams, as well as for their rapid, effective removal if detected. For the continuous PFAS monitoring, an inexpensive, field-deployable, in situ sensor is urgently needed; yet the prevalent in situ techniques often struggle to strike a balance between the practical sensitivity and selectivity demands of the real world. Similarly, for effective PFAS removal, strategies for their fast, selective, and quantitative capture are desired, yet the present commercially available sorbents are unable to meet the requirements of rapid, quantitative capture of all PFAS components, and are notably inefficient in removing the more toxic smaller chains. To address these twin challenges, Pacific Northwest National Laboratory is developing strategies for improved detection and remediation of PFAS. For the rapid, selective, quantitative removal of PFAS from environmental streams, the strategy relies on designing capture probes with exclusively tailored electronic and spatial affinities for the PFAS that are able to selectively capture them from environmental streams. For the in situ detection and quantification of PFAS in complex, multicomponent matrices such as groundwater, the approach relies on the targeted capture of specific PFAS by these PFAS-specific capture probes immobilized on a platform. The platform acts as an electrode to directly measure PFAS concentration through a proportional change in electrical response upon their capture. A combination of optimization of platform design and incorporation of additional, sensitive detection modalities have allowed us to achieve detection limits as low as 0.5 ng/L for detection of PFAS compounds (compared to the 70 ng/L Health Advisory Limit of the U.S. Environmental Protection Agency). (authors)

47 OTHER INSTRUMENTATION↗

Dielectrophoresis assisted rapid, selective and single cell detection of antibiotic resistant bacteria with G-FETs

Time-consuming, expensive and low sensitivity diagnostic methods used for monitoring bacterial infections lead to unnecessary or delays in prescription of the right antibiotic treatment. Determining an optimal clinical treatment requires rapid detection and identification of pathogenic bacteria and their sensitivity to specific antimicrobials. However, diagnostic devices that meet all of these criteria have proven elusive thus far. Graphene field effect transistors (G-FET) are a promising solution, since they are highly sensitive to chemical/biological modification, can have fast detection times and can be placed on different substrates. Here, by integrating specific peptide probes over G-FETs, we present a proof-of-concept study for species and strain specific label-free detection of clinical strains of pathogenic bacteria with high specificity and sensitivity. We found that pyrene-conjugated peptides immobilized on G-FETs were capable of detecting pathogenic Staphylococcus aureus at the single-cell level and discriminate against other gram-positive and gram-negative bacterial pathogens. A similar device was able to discriminate between antibiotic resistant and sensitive strains of Acinetobacter baumannii , suggesting that these devices can also be used for detecting antibiotic resistive pathogens. Furthermore, a new means of enhancing attachment, electric-field assisted binding, reduced the detection limit to 104 cells/ml and the detection time to below 5 minutes. Here, the combination of single step attachment, inexpensive production, rapid, selective and sensitive detection suggest G-FETs plus pyrene-conjugated peptides are a new platform for solving major challenges faced in point of care diagnostics to fight infectious diseases and antimicrobial resistance.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Vacuum-ultraviolet absorption cross-sections of functionalized four-carbon species

Absorption cross-sections were measured in the vacuum ultraviolet from 5.17 – 9.92 eV using differential absorption spectroscopy for 33 four-carbon species: n-butane, trans-2-butene, cis-2-butene, butanal, butyric acid, ethyloxirane, trans-2,3-dimethyloxirane, cis-2,3-dimethyloxirane, 2-methyloxetane, 2,2'-bioxirane, vinyl oxirane, 3,4-epoxybutan-2-one, diacetyl, diethyl ether, ethyl vinyl ether, vinyl acetate, acetic anhydride, 1-butanol, 3-buten-1-ol, 1–hydroxy-butan-2-one, 1–hydroxy-butan-3-one, 2,3-epoxybutan-1-ol, 3,4-epoxybutan-1-ol, 2-oxetanemethanol, butanone, methyl vinyl ketone, 4H-1,3-dioxine, allyl formate, 2-oxobutanal, 4-hydroxybutanal, 2-methyloxetan-3-one, cis–but-2-en-1-ol, and trans-2–but-enal. Uncertainties were quantified in all cases by accounting for errors in gas-phase concentration, experimental repeatability, and signal-to-noise ratio as a function of photon energy. With the exception of 2-oxobutanal, which is reported with an uncertainty of 10%, convolving the sources of error using the root-sum-square method led to an upper limit of 5% uncertainty above the detection limit, which is largely attributable to chemical purity. Here, the primary objective of the present work is to provide absolute cross-sections along with quantified uncertainty limits. The majority of the absorption spectra, which reflect electronic transitions such as σ → σ* and n → σ*, are reported for the first time and provide insight into fundamental chemical physics, such as vibrational band structure and Rydberg transitions. The quantitative spectra in the present work facilitates the discovery of chemical intermediates that support improvement in the accuracy of computational models for low-temperature combustion and atmospheric chemistry.

biofuels↗

Advances in PFAS Monitoring and Remediation Using a Functionalized Material Approach

The growing global concerns about the effects to public health from human exposure to per- and polyfluoroalkyl substances (PFAS) motivates the development of strategies for reliable monitoring of PFAS in environmental streams, as well as for their rapid, effective removal if detected. For the continuous PFAS monitoring, an inexpensive, field-deployable, in situ sensor is urgently needed; yet the prevalent in situ techniques often struggle to strike a balance between the practical sensitivity and selectivity demands of the real world. Similarly, for effective PFAS removal, strategies for their fast, selective, and quantitative capture are desired, yet the present commercially available sorbents are unable to meet the requirements of rapid, quantitative capture of all PFAS components, and are notably inefficient in removing the more toxic smaller chains. To address these twin challenges, Pacific Northwest National Laboratory is developing strategies for improved detection and remediation of PFAS. For the rapid, selective, quantitative removal of PFAS from environmental streams, the strategy relies on designing capture probes with exclusively tailored electronic and spatial affinities for the PFAS that are able to selectively capture them from environmental streams. For the in situ detection and quantification of PFAS in complex, multicomponent matrices such as groundwater, the approach relies on the targeted capture of specific PFAS by these PFAS-specific capture probes immobilized on a platform. The platform acts as an electrode to directly measure PFAS concentration through a proportional change in electrical response upon their capture. A combination of optimization of platform design and incorporation of additional, sensitive detection modalities have allowed us to achieve detection limits as low as 0.5 ng/L for detection of PFAS compounds (compared to the 70 ng/L Health Advisory Limit of the U.S. Environmental Protection Agency).

Per- and poly-fluorinated alkyl substances (PFAS),↗