Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid helium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Discrete liquid/vapor detectors for use in liquid helium

Simple devices have been constructed and tested which can discriminate between liquid helium and its vapor. The devices are 0.25-mm doped silicon cubes suspended from 0.05-mm-diameter stainless steel and manganin wires. A small current is passed through the device heating it and lowering its resistance. The degree of self-heating is dependent on whether the device is immersed in liquid or is surrounded by vapor. The voltage across the device then indicates the presence of liquid or vapor. The devices are meant to operate in the milligravity environment of space. Tests simulating thick superfluid films which would be present in this case indicate less than 0.3 milliwatt per detector is sufficient to boil away these thick films. The detector response time under these conditions is less than 50 milliseconds.

Dipirro, M. J.↗

Atomic resolution scanning transmission electron microscopy at liquid helium temperatures for quantum materials

Fundamental quantum phenomena in condensed matter, ranging from correlated electron systems to quantum information processors, manifest their emergent characteristics and behaviors predominantly at low temperatures. This necessitates the use of liquid helium (LHe) cooling for experimental observation. Atomic resolution scanning transmission electron microscopy combined with LHe cooling (cryo-STEM) provides a powerful characterization technique to probe local atomic structural modulations and their coupling with charge, spin and orbital degrees-of-freedom in quantum materials. However, achieving atomic resolution in cryo-STEM is exceptionally challenging, primarily due to sample drifts arising from temperature changes and noises associated with LHe bubbling, turbulent gas flow, etc. In this work, we demonstrate atomic resolution cryo-STEM imaging at LHe temperatures using a commercial side-entry LHe cooling holder. Firstly, we examine STEM imaging performance as a function of He gas flow rate, identifying two primary noise sources: He-gas pulsing and He-gas bubbling. Secondly, we propose two strategies to achieve low noise conditions for atomic resolution STEM imaging: either by temporarily suppressing He gas flow rate using the needle valve or by acquiring images during the natural warming process. Lastly, we show the applications of image acquisition methods and image processing techniques in investigating structural phase transitions in Cr 2 Ge 2 Te 6 , CuIr 2 S 4 , and CrCl 3 . In conclusion, our findings represent an advance in the field of atomic resolution electron microscopy imaging for quantum materials and devices at LHe temperatures, which can be applied to other commercial side-entry LHe cooling TEM holders.

36 MATERIALS SCIENCE↗

Superconductive thin film makes convenient liquid helium level sensor

Sensor consisting of superconductive film mounted on a dipstick measures the level of liquid helium in a Dewar flask. The sensor is made by depositing a thin film of niobium metal to a thickness of 2000 angstroms on a quartz substrate, which is then mounted on a graduated dipstick.

Becker, H. H.↗

Thermal conductance of pressed brass contacts at liquid helium temperatures

An apparatus has been designed and fabricated which will measure the thermal conductance of pressed contacts at liquid helium temperatures as a function of applied force, with surface finish as a parameter. The apparatus is automated and was used to measure thermal conductance at temperatures from 1.5 to 6.5 K at applied forces up to 700 N for brass sample pairs having surface finishes from 0.1 to 1.6 micron rms. The experimental data were found to fit a simple power law where the thermal conductance is given by k = alpha T exp n, where k is the thermal conductance, T is the absolute temperature, and alpha and n are empirically determined constants.

Salerno, L. J.↗

A study of DC electrical breakdown in liquid helium through analysis of the empirical breakdown field distributions

Here we report results from a study on electrical breakdown in liquid helium using near-uniform-field stainless steel electrodes with a stressed area of ~0.7cm 2 . The distribution of the breakdown field is obtained for temperatures between 1.7 K and 4.0 K, pressures between the saturated vapor pressure and 626 Torr, and with electrodes of different surface polishes. A data-based approach for determining the electrode-surface-area scaling of the breakdown field is presented. The dependence of the breakdown probability on the field strength as extracted from the breakdown field distribution data is used to show that breakdown is a surface phenomenon closely correlated with Fowler–Nordheim field emission from asperities on the cathode. We show that the results from this analysis provide an explanation for the supposed electrode gap-size effect and also allow for a determination of the breakdown-field distribution for arbitrary shaped electrodes. Most importantly, the analysis method presented in this work can be extended to other noble liquids to explore the dependencies for electrical breakdown in those media.

74 ATOMIC AND MOLECULAR PHYSICS↗

Proposed mechanistic model to simulate transfer line cool-down process using liquid helium

This paper proposes a mathematical model to simulate the cool-down behavior of a warm transfer line using liquid helium (including He II) in a microgravity environment. The thermal-hydraulic characteristics of different possible flow regimes which may occur during the cool-down process are discussed. Correlations for predicting the heat and momentum transfer rates in each flow regime are presented.

Ng, Y. S.↗

Slosh wave excitation of cryogenic liquid helium in gravity Probe-B rotating dewar

The dynamical behavior of fluids, in particular the effect of surface tension on partially-filled rotating fluids (cryogenic liquid helium and helium vapor) in a full scale Gravity Probe-B Spacecraft propellant dewar tank imposed by various frequencies of gravity jitters have been investigated. Fluid stress distribution, caused by the excitation of slosh waves and their associated large amplitude disturbances on the liquid-vapor interface, exerted on the outer and inner walls of rotating dewar container also have been investigated. Results show that fluid stress distribution exerted on the outer and inner walls of rotating dewar are closely related to the characteristics of slosh waves excited on the liquid-vapor interface in the rotating dewar tank.

Hung, R. J.↗

Infrared absorptivities of transition metals at room and liquid-helium temperatures.

Evaluation of experimental data concerning the normal spectral absorptivities of the transition metals, nickel, iron, platinum, and chromium, at both room and liquid-helium temperatures in the wavelength range from 2.5 to 50 microns. The absorptivities were derived from reflectivity measurements made relative to a room-temperature vapor-deposited gold reference mirror. The absorptivity of the gold reference mirror was measured calorimetrically, by use of infrared laser sources. Investigation of various methods of sample-surface preparation resulted in the choice of a vacuum-annealing process as the final stage. The experimental results are discussed on the basis of the anomalous-skin-effect theory modified for multiple conduction bands. As predicted, the results approach a single-band model toward the longer wavelengths. Agreement between theory and experiment is considerably improved by taking into account the modification of the relaxation time due to the photon-electron-phonon interaction proposed by Holstein (1954) and Gurzhi (1958); but, particularly at helium temperatures, the calculated curve is consistently below the experimental results.

Jones, M. C.↗

Maximum Expected Wall Heat Flux and Maximum Pressure After Sudden Loss of Vacuum Insulation on the Stratospheric Observatory for Infrared Astronomy (SOFIA) Liquid Helium (LHe) Dewars

The aircraft-based Stratospheric Observatory for Infrared Astronomy (SOFIA) is a platform for multiple infrared observation experiments. The experiments carry sensors cooled to liquid helium (LHe) temperatures. A question arose regarding the heat input and peak pressure that would result from a sudden loss of the dewar vacuum insulation. Owing to concerns about the adequacy of dewar pressure relief in the event of a sudden loss of the dewar vacuum insulation, the SOFIA Program engaged the NASA Engineering and Safety Center (NESC). This report summarizes and assesses the experiments that have been performed to measure the heat flux into LHe dewars following a sudden vacuum insulation failure, describes the physical limits of heat input to the dewar, and provides an NESC recommendation for the wall heat flux that should be used to assess the sudden loss of vacuum insulation case. This report also assesses the methodology used by the SOFIA Program to predict the maximum pressure that would occur following a loss of vacuum event.

Ungar, Eugene K.↗

Effect of an electric field on liquid helium scintillation produced by fast electrons

The dependence on applied electric field (0–40 kV/cm) of the scintillation light produced by fast electrons and α particles stopped in liquid helium in the temperature range of 0.44 K to 3.12 K is reported. For both types of particles, the reduction in the intensity of the scintillation signal due to the applied field exhibits an apparent temperature dependence. Using an approximate solution of the Debye-Smoluchowski equation, we show that the apparent temperature dependence for electrons can be explained by the time required for geminate pairs to recombine relative to the detector signal integration time. This finding indicates that the spatial distribution of secondary electrons with respect to their geminate partners possesses a heavy, non-Gaussian tail at larger separations and has a dependence on the energy of the primary ionization electron. Here, we discuss the potential application of this result to pulse shape analysis for particle detection and discrimination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optical Fiber Distributed Sensing Structural Health Monitoring (SHM) Strain Measurements Taken During Cryotank Y-Joint Test Article Load Cycling at Liquid Helium Temperatures

This paper outlines cryogenic Y-joint testing at Langley Research Center (LaRC) to validate the performance of optical fiber Bragg grating strain sensors for measuring strain at liquid helium temperature (-240 C). This testing also verified survivability of fiber sensors after experiencing 10 thermal cool-down, warm-up cycles and 400 limit load cycles. Graphite composite skins bonded to a honeycomb substrate in a sandwich configuration comprised the Y-joint specimens. To enable SHM of composite cryotanks for consideration to future spacecraft, a light-weight, durable monitoring technology is needed. The fiber optic distributed Bragg grating strain sensing system developed at LaRC is a viable substitute for conventional strain gauges which are not practical for SHM. This distributed sensing technology uses an Optical Frequency Domain Reflectometer (OFDR). This measurement approach has the advantage that it can measure hundreds of Bragg grating sensors per fiber and the sensors are all written at one frequency, greatly simplifying fiber manufacturing. Fiber optic strain measurements compared well to conventional strain gauge measurements obtained during these tests. These results demonstrated a high potential for a successful implementation of a SHM system incorporating LaRC's fiber optic sensing system on the composite cryotank and other future cryogenic applications.

Allison, Sidney G.↗

Effect of mass flow rate on gas propagation after vacuum break in a liquid helium cooled tube

Vacuum break in particle accelerators is a major concern due to risks associated with personnel and extensive equipment damage. Continuing research in our lab focuses on the sudden loss of vacuum in the liquid helium cooled beam-line tubes of superconducting particle accelerators. In our previous research, we studied nitrogen gas propagation in a uniform tube system immersed in both normal helium (He I) and superfluid helium (He II). It was observed that He II has a stronger effect in slowing down the gas propagation compared to He I, but this effect was largely due to the variation of the point where condensation and deposition of the nitrogen gas on the tube inner wall. Here, we discuss our modifications to the tube system that now allow us to accurately control the starting location of gas condensation in both the He I and He II experiments. Systematic studies of gas propagation were conducted using this new tube system by varying the nitrogen mass flow rate at the tube inlet.

43 PARTICLE ACCELERATORS↗

Development of a liquid-helium free cryogenic sample holder with mK temperature control for autonomous electron microscopy

The automated and autonomous cryogenic transmission electron microscopy (Cryo-EM) demands a sample holder capable of maintaining temperatures below 10 K with precise control, long holding times, and minimal helium use. Rising to this challenge, we initiated an ambitious project to develop a novel closed-cycle cryocooler-based cryogenic sample holder that operates without the use of liquid helium and the consumption of gaseous helium. Here, this article presents the design, construction, and experimental testing of the initial prototype, which achieves an ultimate temperature of 5.6 K with exceptional stability close to 1mK, while providing a wide temperature control range from 295 K to 5.6 K, marking a clear advancement in cryo-EM holder development. While the prototype was not designed for atomic resolution imaging and thus lacks a sturdy support system to mitigate mechanical vibrations from the cryocooler's pulsed tube, this innovative approach successfully demonstrates proof of concept. It offers unprecedented capabilities for state-of-the-art cryogenic microscopy and microanalysis in materials and biological sciences.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measuring Q₀ in LCLS-II Cryomodules Using Helium Liquid Level

The nitrogen-doped cavities used in the Linac Coherent Light Source II (LCLS-II) cryomodules have shown an unprecedented high Q₀ in vertical and cryomodule testing compared with cavities prepared with standard methods. While demonstration of high Q₀ in the test stand has been achieved, maintaining that performance in the linac is critical to the success of LCLS-II and future accelerator projects. The LCLS-II cryomodules required a novel method of measuring Q₀, due to hardware incompatibilities with existing procedures. Initially developed at Jefferson Lab during cryomodule acceptance testing before being used in the tunnel at SLAC, we use helium liquid level data to estimate the heat generated by cavities. We first establish the relationship between the rate of helium evaporation from known heat loads using electric heaters, and then use that relationship to determine heat from an RF load. Here we present the full procedure along with the development process, lessons learned, and reproducibility while demonstrating for the first time that world record Q₀ can be maintained within the real accelerator environment.

43 PARTICLE ACCELERATORS↗

Development of a motorized cryovalve for the control of superfluid liquid helium

Recent advances in the technology of infrared detectors have made possible a wide range of scientific measurements and investigations. One of the requirements for the use of sensitive IR detectors is that the entire instrument be cooled to temperatures approaching absolute zero. The cryogenic cooling system for these instruments is commonly designed as a large dewar containing liquid helium which completely surrounds the apparatus. Thus, there is a need for a remotely controlled, motorized cryovalve that is simple, reliable, and compact and can operate over extended periods of time in cryo-vac conditions. The design, development, and test of a motorized cryovalve with application to a variety of cryogenic systems currently under development is described.

Lorell, K. R.↗