At least 73 records · Page 4

CACTI ARM Aerial Facility Measurements of Ice Nucleating Particles

The dataset comprises measures, using Colorado State University's Ice Spectrometer (IS, an immersion freezing device with a range from 0°C down to -26 to -29°C) of atmospheric ice nucleating particle (INP) concentrations taken on the Atmospheric Radiation Measurement (ARM) program Aerial Facilty (AAF) G-1 aircraft. INP measurements on the G-1 were collected from varied altitudes on different flights over the region of the Sierras de Córdoba mountain range of north-central Argentina, centred over ARM's Mobile Facility (AMF-1) near Villa Yacanto, where ground-based INP measures were being taken concurrently. Both studies took place as part of the Cloud, Aerosol, and Complex Terrain Interactions (CACTI) Experiment. A filter sampling system was deployed on the G-1 to collect aerosol particles for post-processing of INPs collected on filters (measuring their immersion freezing ability) once returned to Colorado State University (CSU). Filter holders used were pre-cleaned aluminum in-line units loaded with pre-cleaned and pre-sterilized 47 mm dia. Nuclepore polycarbonate filters (0.2 mm pore size). Filters were drawn for varied times, resulting in varied volumes collected (51 to 1667 SL). Mass flow rate was recorded in real-time so that total sampled volume (at standard temperature and pressure) could be determined. A total of 34 sample filters were collected over the IOP, including 5 blanks. Filters were stored at -20°C freezer prior to frozen return to Colorado State University (CSU). . Processing to obtain spectra of INP number concentration active via the immersion freezing mechanism versus temperature was conducted using CSU's IS instrument (McCluskey et al., 2018). For measurment of INPs, collected aerosol particles were re-suspended in 7 mL of 0.02 µm-filtered deionized water. Aliquots of each suspension, and serial dilutions, were dispensed into trays which were fit into aluminum blocks in the IS. Samples are cooled at 0.33°C min-1 and the freezing temperatures of wells recorded automatically. Cumulative INP concentrations were determined by first calculating the INPs per mL of suspension based on Vali (1971) and then converting to concentration per standard liter of air using the proportion of the total liquid sample dispensed and the air sample volumes. Aliquots of suspensions from selected samples were also heat treated (95°C for 20 min) to denature and deactivate biological INPs, and digested in 10% H2O2 at 95°C under UV-B to remove all organic carbon INPs. McCluskey, C. S., J. Ovadnevaite, M. Rinaldi, J. Atkinson, F. Belosi, D. Ceburnis, S. Marullo, T. C. J. Hill, U. Lohmann, Z. A. Kanji, C. O’Dowd, S. M. Kreidenweis, P. J. DeMott, 2018: Marine and Terrestrial Organic Ice Nucleating Particles in Pristine Marine to Continentally-Influenced Northeast Atlantic Air Masses, Journal of Geophysical Research: Atmospheres, 123, 6196–6212, https://doi.org/10.1029/2017JD028033. Vali, G., 1971: Quantitative evaluation of experimental results on the heterogeneous freezing nucleation of supercooled liquids. J. Atmos. Sci., 28, 402–409.

54 ENVIRONMENTAL SCIENCES↗

CACTI ARM Mobile Facility (AMF) Measurements of Ice Nucleating Particles

The dataset comprises measures, using Colorado State University's Ice Spectrometer (IS, an immersion freezing device with a range from 0°C down to -26 to -29°C) of atmosperic ice nucleating particle (INP) concentrations taken on ARM's Mobile Facility (AMF-1) Aerosol Observing System, near Villa Yacanto in central Argentina, during the Cloud, Aerosol, and Complex Terrain Interactions (CACTI) Experiment. A filter sampler was mounted on the AOS trailer (2 m below the AOS inlet). Single-use filter units open to the atmosphere fitted with pre-cleaned and pre-sterilized, 47-mm dia. Nuclepore polycarbonate filters were used. Filters were typically drawn for an 8-hour period, totaling 6000 liters sampled on average. After collection, filters were stored at -20°C until processed. Initial processing to obtain spectra of INP number concentration active via the immersion freezing mechanism versus temperature was conducted using CSU's IS instrument (McCluskey et al., 2018). For measurment of INPs, collected aerosol particles were re-suspended in 7-8 mL of 0.1 µm-filtered deionized (DI) water. Aliquots of each suspension, and serial dilutions, were dispensed into trays which were fit into aluminum blocks in the IS. Samples are cooled at 0.33°C min-1 and the freezing temperatures of wells recorded automatically. Cumulative INP concentrations were determined by first calculating the INPs per mL of suspension based on Vali (1971) and then converting to concentration per standard liter of air using the proportion of the total liquid sample dispensed and the air sample volumes. An aliquot of suspension fro selected samples were also heat treated (95°C for 20 min) to denature and deactivate biological INPs, and another aliquot digested in 10% H2O2 at 95°C under UV-B to remove all organic carbon INPs. McCluskey, C. S., J. Ovadnevaite, M. Rinaldi, J. Atkinson, F. Belosi, D. Ceburnis, S. Marullo, T. C. J. Hill, U. Lohmann, Z. A. Kanji, C. O’Dowd, S. M. Kreidenweis, P. J. DeMott, 2018: Marine and Terrestrial Organic Ice Nucleating Particles in Pristine Marine to Continentally-Influenced Northeast Atlantic Air Masses, Journal of Geophysical Research: Atmospheres, 123, 6196–6212, https://doi.org/10.1029/2017JD028033. Vali, G., 1971: Quantitative evaluation of experimental results on the heterogeneous freezing nucleation of supercooled liquids. J. Atmos. Sci., 28, 402–409.

54 ENVIRONMENTAL SCIENCES↗

AEROICESTUDY-Colorado State University Ice Spectrometer

The dataset comprises measures, using Colorado State University's Ice Spectrometer (IS, an immersion freezing device with a range from 0 °C down to -26 to -29 °C) of atmospheric ice nucleating particle (INP) concentrations taken at ARM's Southern Great Plains (SGP) Site Guest Instrument Facility (GIF), in Lamont, Oklahoma, during the Aerosol-Ice Formation Closure Pilot Study (AEROICESTUDY). A filter sampler was mounted approximately 6 m above ground level atop the GIF rooftop platform. Single-use filter units open to the atmosphere fitted with pre-cleaned and pre-sterilized, 47-mm diameter Nuclepore polycarbonate filters were used. Filters were typically drawn for either a full day period (9AM-5PM CDT) or broken up into morning (9AM-12PM CDT) and afternoon (1PM-5PM CDT) periods. Additionally, 4 overnight filters were taken (6PM-8AM CDT). The volume of air filtered was typically between 3000 and 8000 standard liters for daily samples. After collection, filters were stored at -20 °C until processed. Initial processing to obtain spectra of INP number concentration active via the immersion freezing mechanism versus temperature was conducted using CSU's IS instrument (McCluskey et al., 2018). For measurement of INPs, collected aerosol particles were re-suspended in 8 mL of 0.1 µm-filtered deionized (DI) water. Aliquots of each suspension, and serial dilutions, were dispensed into trays which were fit into aluminum blocks in the IS. Samples were cooled at 0.33 °C per min and the freezing temperatures of wells recorded automatically. Cumulative INP concentrations were determined by first calculating the INPs per mL of suspension based on Vali (1971) and then converting to concentration per standard liter of air using the proportion of the total liquid sample dispensed and the air sample volumes. Two-tailed, 95% confidence intervals for binomial sampling were based on Equation 2 from Agresti and Coull (1998). Aliquots of suspensions from selected samples were also heat treated (95 °C for 20 min) to denature and deactiv

54 ENVIRONMENTAL SCIENCES↗

Isotope effects on the high pressure viscosity of liquid water measured by differential dynamic microscopy

In this paper, differential dynamic microscopy is performed in diamond anvil cells to measure the viscosity of water along the 24 °C isotherm to high-pressure by determination of the tracer diffusion coefficient of monodisperse silica spheres of known diameter and application of the Stokes-Einstein-Sutherland equation. This technique allows liquid samples to be compressed to greater pressure prior to freezing than with other viscometry methods. The highest-pressure measurement was made at 1.67 GPa, considerably deeper into the supercompressed regime than previously reported. The effect of isotopic composition is investigated with samples of normal water, heavy water, and partially deuterated water. When data below 0.25 GPa are excluded a free volume model fits the observed viscosities well yielding a theoretical glass transition density close to that observed in very-high-density amorphous ice. The improved fit above 0.25 GPa coincides with the loss of other anomalous behaviors in liquid water caused by hydrogen bonding and represents a transition to properties closer to those of a simple liquid.

74 ATOMIC AND MOLECULAR PHYSICS↗

Seasonal Patterns in Mobile Colistin Resistance Gene Variants in Wastewater Bioaerosols and Liquid Sludge

To address the growing threat of global antimicrobial resistance, a one-health approach is needed to understand the complex socioecological cycling of antibiotic resistance genes. In this study, a metagenomics approach using DNA shotgun sequencing, metagenome assembly, and antibiotic resistance gene (ARG) annotation was used to examine seasonal patterns in the abundance of mobile colistin resistance (mcr) gene variants in bioaerosols and liquid sludge in three wastewater treatment plants (WWTPs). ARGs represented 0.2–0.8 and 0.1–0.2% of the bioaerosol and liquid sludge metagenomes, respectively, while mcr genes represented 0–0.3 and 0–0.5% of the identified ARGs in bioaerosol and liquid sludge metagenomes. Seven of the ten known mcr variants were detected in wastewater bioaerosol and liquid samples, with mcr-5 and mcr-8 being the most prevalent across all seasons and sites. Furthermore, additional functional and taxonomic annotation of mcr-containing metagenomic contigs showed that mcr genes were often located on contigs with other co-occurring ARGs and mobile genetic elements and may be harbored by opportunistic human pathogens and other bacterial taxa not previously associated with mcr genes. Atmospheric dispersion modeling showed that mcr-containing bioaerosols can be transported kilometers away from the WWTPs, resulting in the possible dissemination of these ARGs into surrounding environments and communities.

Antimicrobial agents↗

Clustering Nuclear Magnetic Resonance: Machine learning assistive rapid two‐dimensional relaxometry mapping

Abstract Low‐field nuclear magnetic resonance (NMR) relaxometry is an attractive approach from point‐of‐care testing medical diagnosis to in situ oil‐gas exploration. One of the problems, however, is the inherently long relaxation time of the (liquid) samples, (and hence low signal‐to‐noise ratio) which causes unnecessarily long repetition time. In this work, a new class of methodology is presented for rapid and accurate object classification using NMR relaxometry with the aid of machine learning. It is demonstrated that the sensitivity and specificity of the classification is substantially improved with higher order of (pseudo)‐dimensionality (e.g., 2D‐ or multi‐dimensional). This new methodology (termed as ‘Clustering NMR’) may be extremely useful for rapid and accurate object classification (in less than a minute) using low‐field NMR.

Peng, Weng Kung↗

Esterification of 3-quinuclidinol, a marker for the incapacitant BZ, for analysis by EI-GC-MS in OPCW test matrices

The analysis by EI-GC-MS of 3-quinuclidinol (3Q), a marker for the riot control and incapacitating agent quinuclinidyl benzilate (BZ), using several, new acylation strategies is described. After evaluating and optimizing conditions for the acylations, these were tested on their ability to successfully derivatize 3Q in three different matrices featured in the 44th Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency test (PT). As 3Q is a highly polar compound, the work here describes acylation strategies that generate 3Q analogs with superior gas chromatographic profiles relative to the underivatized material. The acyl groups studied in this work included acetyl, benzoyl, pentafluorobenzoyl and the bis(3,5-trifluoromethyl)benzoyl. The acylated 3Q products provide sharp, detectable peaks with significantly different retention times from that of the unmodified 3Q. Thus, the retention times for acetyl-, benzoyl-, pentafluorobenzoyl- and 3,5-bis(trifluoromethyl)benzoyl-3Q were determined to be 15.9, 24.9, 22.8 and 22.1 min respectively, in stark contrast to the unmodified 3Q which provides a sharp peak with a retention time centered at ~ 13.5 min only at high concentrations (> 10 µg/mL or µg/g) while a broad peak (RT ~ 15–15.5 min) at low concentrations (< 5 µg/mL or µg/g). The developed protocol was used to derivatize 3Q in three separate matrices. The first two matrices were liquid samples featured during the 44th OPCW PT at two separate concentrations in each (5 and 50 µg/mL). The last matrix was a soil sample featured in the same 44th OPCW PT wherein the 3Q had been spiked at a 12 µg/g concentration. The approach involves the extraction of 3Q from all matrices followed by its acylation resulting in a second reportable analytical method for an OPCW PT. The presented derivatization strategies should find wide applicability particularly in laboratories involved with the analysis of this chemical weapon agent degradation product and those participating in the yearly OPCW PTs.

3-quinuclidinol↗

Effect of frequency and applied voltage of an atmospheric-pressure dielectric-barrier discharge on breakdown and hydroxyl-radical generation with a liquid electrode

This work examines the effect of the frequency and peak applied voltage on hydroxyl-radical generation in a dielectric-barrier plasma discharge between a metallic needle electrode and one electrode covered with dielectric. The authors examine a system that can expose up to 96 liquid samples in an automated fashion without human intervention beyond setting the initial software configuration. Then, hydroxylradical concentration, measured through coumarin fluorescence, was measured for 5 s plasma exposures generated under different highvoltage conditions with frequencies from 2 to 16 kHz and amplitudes from 4 to 9 kV. Their results show that an increase in frequency and/or applied voltage, within the range prescribed above and the limits of the high-voltage power supply, can yield up to a 150% increase in fluorescence with an equivalent hydroxyl-radical increase. Applications using typical previous methods, such as the Fenton Reaction, are limited in that they continuously generate hydroxyl radicals over millisecond and longer intervals. These results establish the electrical parameters that can now be applied to polymers, like proteins, which show three dimensional structures that are flexible and fluctuate on a microsecond and nanosecond time scale, with hydroxyl-radical generation on this time scale using this device. Additionally, plasma exposures may be optimized for a great variety of proteins, devices and techniques, where hydroxyl-radical generation is of utmost importance, reducing exposure time and potential subjection of samples to harmful side effects.

42 ENGINEERING↗

Coupling Pulse Radiolysis with Nanosecond Time-Resolved Step-Scan Fourier Transform Infrared Spectroscopy: Broadband Mid-Infrared Detection of Radiolytically Generated Transients

We describe the first implementation of broadband, nanosecond time-resolved step-scan Fourier transform infrared (S 2 -FT-IR) spectroscopy at a pulse radiolysis facility. This new technique allows the rapid acquisition of nano- to microsecond time-resolved infrared (TRIR) spectra of transient species generated by pulse radiolysis of liquid samples at a pulsed electron accelerator. Wide regions of the mid-infrared can be probed in a single experiment, which often takes < 20–30 min to complete. It is therefore a powerful method for rapidly locating the IR absorptions of short-lived, radiation-induced species in solution, and for directly monitoring their subsequent reactions. Time-resolved step-scan FT-IR detection for pulse radiolysis thus complements our existing narrowband quantum cascade laser-based pulse radiolysis-TRIR detection system, which is more suitable for acquiring single-shot kinetics and narrowband TRIR spectra on small-volume samples and in strongly absorbing solvents, such as water. We have demonstrated the application of time-resolved step-scan FT-IR spectroscopy to pulse radiolysis by probing the metal carbonyl and organic carbonyl vibrations of the one-electron-reduced forms of two Re-based CO 2 reduction catalysts in acetonitrile solution. Transient IR absorption bands with amplitudes on the order of 1 × 10 −3 are easily detected on the sub-microsecond timescale using electron pulses as short as 250 ns.

(S2-FT-IR)↗

A New Experimental Station for Liquid Interface X-Ray Scattering At NSLS-II Beamline 12-ID

Open Platform and Liquids Scattering (OPLS) is a new experimental station recently built and currently being commissioned at the Soft Matter Interfaces (SMI) beamline 12-ID at NSLS-II. The new instrument expands SMI’s beamline scientific capabilities via the addition of X-ray scattering techniques from liquid surfaces and interfaces. The design of this new instrument, located inside the 12-ID beamline shielding enclosure (hutch B), is based on a single Ge (111) crystal deflector, which bounces the incident x-ray beam downward towards a liquid sample which must be maintained in a horizontal orientation (gravity-driven consideration). The OPLS instrument has a variable deflector-to-sample distance ranging from 0.6 m to 1.5 m. X-ray detectors are mounted on a 2-theta scattering arm located downstream of the sample location. The 2-theta arm is designed to hold up to three X-ray detectors, with fixed 2-theta angular offsets, each dedicated to a different X-ray technique such as X-ray reflectivity, grazing-incidence X-ray scattering, and small- and wide-angle X-ray scattering. Currently, the OPLS experimental station intercepts the SMI beam that otherwise propagates to the experimental endstation located in hutch C and can be retracted to a ’parking’ position laterally out of this beam to allow installation of a removable beam pipe that is needed to support operations in hutch C. The design of OPLS is flexible enough to quickly adapt to a planned future configuration of the SMI beamline in which a OPLS is illuminated separately from the main SMI branch via a second, canted undulator source and a separate photon delivery system. In this future configuration, both branches will be able to operate independently and simultaneously.

36 MATERIALS SCIENCE↗

Potential for Evaporation and In Situ Reaction of Organic Compounds in Hanford Supplemental LAW

The presence of regulated organic species in Hanford nuclear tank waste is assessed in this report, along with fate of the organics and possible evaporative treatment. A narrowed list of regulated organic species of concern is developed based upon published analyses, chemical properties like aqueous solubility, and chemical reactivity under alkaline conditions. Published analyses include tank headspace and liquid samples, review of chemical reagents formerly used at Hanford, and the Tank Waste Information Network System (TWINS). This work supports possible stabilization of Hanford Supplemental Low Activity Waste (SLAW) by grouting.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Potential for Evaporation and In Situ Reaction of Organic Compounds in Hanford Supplemental LAW

The presence of regulated organic species in Hanford nuclear tank waste is assessed in this report, along with fate of the organics and possible evaporative treatment. A narrowed list of regulated organic species of concern is developed based upon published analyses, chemical properties like aqueous solubility, and chemical reactivity under alkaline conditions. Published analyses include tank headspace and liquid samples, review of chemical reagents formerly used at Hanford, and the Tank Waste Information Network System (TWINS). This work supports possible stabilization of Hanford Supplemental Low Activity Waste (SLAW) by grouting.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

R&D with NREL'S Nuclear Magnetic Resonance (NMR) Facility

NREL's state-of-the-art NMR Facility provides scientists the ability to analyze both solid and liquid samples on four NMR spectrometers. NREL's NMR instruments provide distinct capabilities for analyzing a variety of samples from biomass to plastics to battery components. NREL scientists can monitor reactions - even in real time - to further their understanding of the fundamental chemical processes that may drive the development of next-generation sustainable fuels, materials, and products.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Melting LHC detectors: a novel search for stopped long-lived particles

Particles at the TeV scale with lifetimes of a year or longer could have been abundantly produced at the LHC yet escaped detection because of backgrounds, and could still be trapped within detector materials. With gluinos in split-supersymmetry as a working example, we show that these trapped particles can be recovered from detector materials once prepared in liquid form, for example, by melting silicon detectors, extracting liquid argon from the electromagnetic calorimeter, or constructing a large water pool near ATLAS or CMS. These liquid samples can then be processed using iterative centrifugation followed by mass spectrometry, enabling single-particle sensitivity in macroscopic samples. This method can potentially discover gluinos up to 3 TeV in mass at the HL-LHC. It can also improve upon existing limits for other long-lived particles. For example, it can discover the stop up to 2 TeV, and will also be sensitive to integer-charged particles in the TeV range.

Gonski, Julia L. [SLAC]↗

Determination of Total, Organic, and Inorganic Carbon in Biological Cultures and Liquid Fraction Process Samples

This procedure describes a method for analyzing dissolved and suspended total carbon, in organic and inorganic form in biological cultures, in the presence or absence of cells, and liquid fraction conversion process samples. This method calculates total organic carbon by subtraction of inorganic carbon, derived from sample acidification, from total dissolved carbon by combustion at 680°C with detection of derived gaseous CO 2 by a non-dispersive infrared (NDIR) sensor. The inclusion of details on a process step of heat treating biologically active samples before analysis can potentially halt biological activity, preserving carbon stores and allowing for accurate quantification of the carbon content at the time of sample collection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated Coupling of Nanodroplet Sample Preparation with Liquid Chromatography–Mass Spectrometry for High-Throughput Single-Cell Proteomics

Single-cell proteomics can provide critical biological insight into the cellular heterogeneity that is masked by bulk-scale analysis. Here, we have developed a nanoPOTS (nanodroplet processing in one pot for trace samples) platform and demonstrated its broad applicability for single-cell proteomics. However, because of nanoliter-scale sample volumes, the nanoPOTS platform is not compatible with automated LC-MS systems, which significantly limits sample throughput and robustness. To address this challenge, we have developed a nanoPOTS autosampler allowing fully automated sample injection from nanowells to LC-MS systems. We also developed a sample drying, extraction, and loading workflow to enable reproducible and reliable sample injection. The sequential analysis of 20 samples containing 10 ng tryptic peptides demonstrated high reproducibility with correlation coefficients of >0.995 between any two samples. The nanoPOTS autosampler can provide analysis throughput of 9.6, 16, and 24 single cells per day using 120, 60, and 30 min LC gradients, respectively. As a demonstration for single-cell proteomics, the autosampler was first applied to profiling protein expression in single MCF10A cells using a label-free approach. At a throughput of 24 single cells per day, an average of 256 proteins was identified from each cell and the number was increased to 731 when the Match Between Runs algorithm of MaxQuant was used. Using a multiplexed isobaric labeling approach (TMT-11plex), ~77 single cells could be analyzed per day. We analyzed 152 cells from three acute myeloid leukemia cell lines, resulting in a total of 2558 identified proteins with 1465 proteins quantifiable (70% valid values) across the 152 cells. These data showed quantitative single-cell proteomics can cluster cells to distinct groups and reveal functionally distinct differences.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗