Validation of UNF-ST&DARDS As-loaded safety analysis methods for BWR decay heat calculations
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Abstract not provided.
The tools developed within the U.S. Department of Energy (DOE) Office of Nuclear Energy’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program aim at providing high fidelity multiphysics modeling capabilities to support design and licensing of various types of advanced nuclear reactors, including the technologies being developed by U.S. microreactor vendors relying on heat pipe and gas-cooled technologies. In FY-2022, the NEAMS Multiphysics Applications team made significant progress both in demonstrating capabilities applied to microreactor problems, and in supporting NEAMS developers.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
This report describes the specimen loading order and documents all preirradiation examination material property measurement data for graphite specimens contained within the Second Advanced Graphite Capsule (AGC 2) irradiation capsule. The AGC 2 capsule is the second in six planned irradiation capsules comprising the Advanced Graphite Creep (AGC) test series. The AGC test series is used to irradiate graphite specimens in order to garner quantitative data necessary for predicting the irradiation behavior and operating performance of new nuclear grade graphites. This testing will ascertain the in service behavior of the graphite for pebble bed and prismatic very high temperature reactor designs. Similar to the First Advanced Graphite Capsule (AGC 1) preirradiation examination report, material property tests were conducted on specimens from 18 nuclear grade graphite types. However, AGC 2 tested an increased number of specimens (i.e., 512) prior to loading them into the AGC 2 irradiation assembly. All AGC 2 specimen testing was conducted at Idaho National Laboratory from July 2009 to August 2010. This report also details the specimen loading methodology for graphite specimens inside the AGC 2 irradiation capsule. The AGC 2 capsule design requires “matched pair” creep specimens that have similar dose levels above and below the neutron flux profile mid plane. This provides similar specimens with and without an applied load. Analysis in this document utilizes the neutron flux profile calculated for the AGC 2 capsule design, the capsule dimensions, and the size (i.e., length) of the selected graphite specimens to create a stacking order that produces “matched pairs” of graphite specimens above and below the AGC 2 capsule elevation mid point, thus providing specimens with similar neutron dose levels.
This report summarizes the results of the Double-Shell Tank Thermal and Operating Loads Analysis (TaLA) combined with the Seismic Analysis. This combined analysis provides a thorough, defensible, and documented analysis that will become a part of the overall analysis of record for the Hanford double-shell tanks (DSTs). The bases of the analytical work presented herein are two ANSYS{reg_sign} finite element models that were developed to represent a bounding-case tank. The TaLA model includes the effects of temperature on material properties, creep, concrete cracking, and various waste and annulus pressure-loading conditions. The seismic model considers the interaction of the tanks with the surrounding soil including a range of soil properties, and the effects of the waste contents during a seismic event. The structural evaluations completed with the representative tank models do not reveal any structural deficiencies with the integrity of the DSTs. The analyses represent 60 years of use, which extends well beyond the current date. In addition, the temperature loads imposed on the model are significantly more severe than any service to date or proposed for the future. Bounding material properties were also selected to provide the most severe combinations. While the focus of the analyses was a bounding-case tank, it was necessary during various evaluations to conduct tank-specific analyses. The primary tank buckling evaluation was carried out on a tank-specific basis because of the sensitivity to waste height, specific gravity, tank wall thickness, and primary tank vapor space vacuum limit. For this analysis, the occurrence of maximum tank vacuum was classified as a service level C, emergency load condition. The only area of potential concern in the analysis was with the buckling evaluation of the AP tank, which showed the current limit on demand of l2-inch water gauge vacuum to exceed the allowable of 10.4 inches. This determination was based on analysis at the design waste temperature of 350 F and the full 60-year corrosion allowance on the tank wall of 0.060 inch. However, analysis at a more realistic temperature of 250 F or corrosion allowance of 0.025 inch results in an acceptable demand/capacity ratio according to the ASME code criteria. Thus, buckling of the primary tank is judged to be unlikely for the current lack of corrosion in the tanks, and the expectation that the maximum waste temperature will not exceed 210 F. The reinforced concrete structure was evaluated as specified by the American Concrete Institute (ACI) code requirements for nuclear safety-related structures (ACI-349). The demand was demonstrated to be lower than the capacity at all locations. Revision 1 is being issued to document changes to the anchor bolt evaluation. RPP-RPT-32237 Rev. 1, Hanford Double-Shell Tank Thermal and Seismic Project-Increased Liquid Level Analysis for 241AP Tank Farms, described changes to the anchor bolt modeling and evaluation which were implemented in response to the independent reviewer's comments. Similar changes have been made in the bounding tank analysis and are documented in RPP-RPT-28968 Rev. 1. The conclusions of the previous releases of this report remain unchanged.
This paper discusses the design, manufacturing, and planned testing of a scaled demonstrator turbine as part of the Segmented Ultralight Morphing Rotor (SUMR) project funded by the Advanced Project Research Agency - Energy (ARPA-E). The scaled demonstrator (SUMR-D) is based off of a downwind, 13.2 MW SUMR design. This scaled rotor will be tested on the CART2 turbine at the National Wind Technology Center to verify the scaling methodology and planned control scheme. The design was done in an iterative fashion among six teams focused on aerodynamics, structures, and controls. This process included extensive load analysis, modification for manufacturability, adaptations required for testing on the CART2, and ground proof loading. The details of this process are presented here, concluding with planned testing and expectations of performance.
Extreme wind load cases are one of the most important external conditions in the design of offshore wind turbines in hurricane prone regions. Furthermore, in these areas, the increase in load with storm return-period is higher than in extra-tropical regions. However, current standards have limited information on the appropriate models to simulate wind loads from hurricanes. This study investigates turbulent wind models for load analysis of offshore wind turbines subjected to hurricane conditions. Suggested extreme wind models in IEC 61400-3 and API/ABS (a widely-used standard in oil and gas industry) are investigated. The present study further examines the wind turbine response subjected to Hurricane wind loads. Three-dimensional wind simulator, TurbSim, is modified to include the API wind model. Wind fields simulated using IEC and API wind models are used for an offshore wind turbine model established in FAST to calculate turbine loads and response.
The interim stabilized Hanford Single Shell Tanks (SSTs) are currently undergoing a state of the art analysis to assess the structural integrity of the waste storage tanks, for cleanup and closure operations, considering their adverse thermal histories and an updated seismic hazard for the Hanford Site near Richland, Washington. The SSTs contain a variety of ancillary pits, piping, piping supports, risers, equipment, and penetrations known as appurtenances. These appurtenances may alter the structural response and ultimately could affect the structural integrity of the SSTs. An important challenge to the structural analysis of the SSTs is determining the impact of these appurtenances on structural integrity. To achieve this, the various appurtenances were reviewed and bounding appurtenance configurations for SST Types II and III tank designs were analyzed using finite element software. The bounding configurations for the Type II tanks considered four heavy offset pits with a central pit with and without a 36-inch diameter central post-construction penetration and four 42-inch diameter offset penetrations. The bounding configuration for the Type III tanks is a tank with two heavy offset pits and one heavy central pit. For each bounding configuration two finite element models are developed: a seismic analysis model and a thermal and operating loads analysis (TOLA) model. The TOLA models include a Type II or III thermal history, concrete cracking and thermal degradation, reinforcement yielding, and soil plasticity. Additionally, operating loads such as internal waste pressure and concentrated and distributed soil surface loads are applied to the TOLA model. The seismic model treats the tank concrete as linear elastic based on the present day degraded concrete properties. Also, in the seismic model the soil is treated as linear elastic while special techniques are used in the soil above the tank dome and along the tank wall to avoid soil arching and achieve the proper soil pressure on the tank walls. Seismic time histories (in the horizontal and vertical directions) are applied to the seismic model. The American Concrete Institute (ACI) has code requirements for nuclear safety-related concrete structures (ACI-349-06) that are used to evaluate the structural integrity of the SSTs. ACI-349-06 recommends evaluating factored load combinations against reduced tank section capacities to account for both loading and material uncertainties. From both the TOLA and seismic models the structural demands (forces and moments) are extracted from sections throughout the tank under the appropriate load combinations. These demands are compared against the ACI-349-06 capacities at each of the sections. This ratio of demand to capacity is reported as a measure of structural integrity. The Type II and Type III appurtenances configurations are found to increase the demand to capacity ratios in local regions near the appurtenances. Away from the appurtenances the influence on structural integrity is minor. A comparison of the Type II and III results show that even though the Type II offset pits weight less, they have a larger impact on the structural integrity of the tanks due to their locations. Finally, lessons learned from the Type II and Type III appurtenance analysis, and their application to the more complex Type IV structural integrity analysis, will be discussed.
The present paper analyzes failure observed in polymer rods collided with a steel anvil under the Taylor cylinder impact experiments. The experimental and numerical analysis demonstrates that association of the failure patterns with the loading mode depends on the rod material. Two materials are considered in the paper, specifically, polymethylmethacrylate (PMMA) and polycarbonate (PC). Damage in PMMA rods at the Taylor tests is shown to be dominated by the shear load resulting in plastic deformation. In contrast, the major mechanism of damage in PC rods is governed by omni-directional (pressure) mode of load. Analysis of the damage in sections of the rods associated with the glass transition is also addressed in the present theoretical study. Failure in these polymers follows the traditional fracture wave mechanism for brittle glass-type materials due to load in the corresponding mode. Numerical analysis employs a two-phase model with improved inter-phase thermal balance accounting for the inter-phase mass, momentum, and heat exchanges during the glass phase transition, while damage being accumulated in time. In conclusion, the simulation results demonstrate a good correlation with the experimental results.
This chapter describes the single and double shell tanks at Hanford, analysis of record and static and thermal loads analysis.
In-vessel corium retention through external reactor vessel cooling (IVR-ERVC) for a small integral reactor has been evaluated to determine the thermal margin for the prevention of a reactor vessel failure. A thermal load analysis from the corium pool to the outer reactor vessel wall in the lower plenum of the reactor vessel has been performed to determine the heat flux distribution. The critical heat flux (CHF) on the outer reactor vessel wall has been determined to fix the maximum heat removal rate through the external coolant between the outer reactor vessel and the insulation of the reactor vessel. Finally, the thermal margin has been evaluated by comparison of the thermal load with the maximum heat removal rate of the CHF on the outer reactor vessel wall. The maximum heat flux from the corium pool to the outer reactor vessel is estimated at approximately 0.25 MW/m{sup 2} in the metallic layer because of the focusing effect. The CHF of the outer reactor vessel is approximately 1.1 MW/m{sup 2} because of a two phase natural circulation mass flow. Since the thermal margin for the IVR-ERVC is sufficient, the reactor vessel integrity is maintained during a severe accident of a small integral reactor. (authors)
Next generation nuclear reactors such as the advanced high temperature reactor (AHTR) are designed to increase energy efficiency in the production of electricity and provide high temperature heat for industrial processes. The efficient transfer of energy for industrial applications depends on the ability to incorporate effective heat exchangers between the nuclear heat transport system and the industrial process heat transport system. This study considers two different types of heat exchangers - helical coiled heat exchanger and printed circuit heat exchanger - as possible options for the AHTR secondary heat exchangers with distributed load analysis and comparison. Comparison is provided for all different cases along with challenges and recommendations. (authors)
Explore the source record for details and available documents.