Evaluation of Contact Resistance and Fin Effectiveness of Enhanced, Brazed "Dogbone" Fin and Serpentine Tube Heat Exchangers for Air Conditioning and Heat Pump Applications

The energy consumption due to air conditioning is projected to increase by 1.3 and 4.5 times by 2050 compared to 2010 for members and non-members of the Organization of Economic Coordination and Development (OECD), respectively. Greenhouse Gas (GHG) emissions must be carefully managed to minimize their hazardous contribution to climate change. Air conditioners (AC) and heat pumps (HP) contribute with direct GHG emissions through systemic refrigerant leakage, which consequently degrades the system’s performance and therefore increases its indirect GHG emissions as well. To address this issue, the goals of new systems include minimizing leakage risk, using low global warming potential (GWP) refrigerants such as natural refrigerants, and increasing system efficiency. This paper presents part of the efforts in the development of a brazed “dogbone” fin to continuous serpentine tube heat exchanger (HX) for AC/HP applications. The main advantages of such technology are: 1) The potential to reduce 90% or more of the tube return-bends brazed joints compared to conventional tube-fin heat exchangers, thus minimizing leakage vulnerability, enabling the use of natural refrigerants like Propane and Ammonia that carry other concerning risks of flammability and toxicity ; and 2) The brazed fin to the tube joints should yield very low contact resistance. In order to quantify and estimate the impacts of contact resistance and fin effectiveness, a numerical-experimental study is investigated. The novel enhanced brazed “dog-bone” fin is compared to an equivalent pressure expanded fin. The results showed that the expanded fin has consistently greater effective heat transfer but greater contact resistance as well. Furthermore, the brazed fins have up to 20% lower pressure drop. The trade-off comparison shows that the thermal-hydraulic ratio between the two fins is equivalent for air velocities below 2m/s; for greater velocities, however, the expanded fin is favored since it has less fin efficiency penalty. For HVAC&R applications, the air velocities are typically low which makes the proposed technology competitive and a viable option in the pursuit of refrigerant leakage reduction.

30 DIRECT ENERGY CONVERSION↗

Performance Assessment of High-Efficiency Refrigerated Display Cases With Low Global Warming Potential Refrigerants

As California policy makers enforce new regulations such as SB 1383 to achieve state greenhouse gas reduction goals, it will be critical to understand the energy efficiency implications of low global warming potential (GWP) refrigerants in commercial refrigeration applications. The goal of this research project, funded by Commonwealth Edison, was to assess the energy performance of two high-efficiency medium-temperature, self-contained, reach-in display cases that utilized natural refrigerant propane (R-290, GWP = 3), and hydrofluorocarbon (HFC) drop-in hydrofluoroolefin R-513A (GWP = 573). Performance of these display cases was compared to a baseline fixture using HFC (R-134A, GWP = 1301) under equal conditions in a controlled environment chamber. These display cases were selected due to their widespread use in convenience stores and small supermarkets. The high-efficiency cases were equipped with energy-efficient lighting, improved panel insulation, high-efficiency evaporator and condenser fan motors, and high-effectiveness heat exchangers. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 standard method to evaluate each case under equivalent conditions (ASHRAE 2018). However, minor modifications to this methodology were implemented to better represent more realistic operation of the units. While maintaining equivalent target product temperature, the energy-efficient fixtures A (containing R-290, improved insulation, heat exchangers with a higher overall heat transfer coefficient (higher UA), and more efficient lighting and fan motors) and B (containing R-513A, improved fans, and higher UA-heat exchangers, and more efficient lighting and fan motors) consumed 61.8% to 32.6% less energy, respectively, than a baseline case using R-134A refrigerant. The daily energy consumption of the R-290, R-513A, and baseline display cases at the upper limit of environmental conditions was 4.30, 7.59, and 11.26 kWh/day, respectively.

alternative refrigerants↗

A DYNAMIC ENERGY MODEL FOR DISPLAY CASES CONSIDERING FAULTS IN SUPERMARKETS FOR LOW GWP REFRIGERANTION

Display cases are widely used in supermarkets to demonstrate commercial goods for customers, like milk, frozen food, ice-cream, etc. There are two types of display case: open case and closed case. The goods inside display cases need to stay within a stable temperature range to meet the quality standards. However, due to variety of faults (e.g., leaving door opening), it is hard to maintain a stable temperature. The associated energy consumption from display cases is extremely high due to faults. There is a need for a dynamic energy model to accurately predict the good temperature and energy consumption under faults. A dynamic model is developed based on operation data collected through field tests in a low global warming potential (GWP) refrigeration system, at Oak Ridge National Laboratory.

Li, Yanfei↗

Enhancing the Energy Efficiency of Room Air Conditioners in Malaysia: Opportunities and Impact Analysis

The global room air conditioner (AC) market is rapidly transitioning toward variable-speed units, offering significant opportunities for energy-efficient designs and the adoption of low-global warming potential (GWP) refrigerants. Emerging economies, particularly in regions such as Malaysia, are expected to drive consumer demand for ACs. This report reviews key trends in the Malaysian AC market, including the availability of high-efficient ACs. Currently, variable-speed units account for 30–65% of the market, achieving cooling seasonal performance factor (CSPF) levels of between 5.0 and 6.0. Cost comparisons show that CSPF 5–6-rated, inverter-driven room ACs are competitively priced against lower-efficiency, fixed-speed units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DOE Cold Climate Heat Pump Challenge: Development, Metrics, and Early Field Observations

Space heating in residential buildings is a major contributor of Greenhouse Gas (GHG) emissions in the United States. New, advanced electric heat pumps are poised to provide a low carbon alternative to traditional fossil-based heating, especially in colder climates. Widespread deployment of cold climate heat pumps could help address the significant portion of building emissions and primary energy used in American households, but these gains will require broader acceptance from consumers and decision makers. As part of the “Energy, Emissions, and Equity” (E3) initiative, the U.S. Department of Energy launched the Cold Climate Heat Pump Challenge (CCHP) in 2021 to accelerate the deployment of the next generation of air source heat pumps. The Challenge is currently focused on residential, centrally ducted, electric heat pumps, with a nominal cooling capacity greater than or equal to 24,000 Btu/h (2 tons) and less than or equal to 65,000 Btu/h (5 tons). The Challenge specifications represent a best-in-class heat pump product that provides high-efficiency heating performance in cold climates, employs environmentally friendly low-Global Warming Potential (GWP) refrigerants, and is designed to be grid interactive. Spearheaded by DOE in partnership with the US Environmental Protection Agency (EPA) and Natural Resources Canada (NRCan), the CCHP Challenge brings together numerous major heat pump manufacturers and key stakeholders including utilities and state agencies across the country. In addition to performance testing in a laboratory environment, a key component of this research is evaluating the in-field performance of the prototype heat pumps developed as part of the Challenge. This paper will discuss the development of the CCHP Challenge, key performance specifications, and the energy and non-energy metrics that will be evaluated through the field study. The types of data that are being collected from the units installed in homes across North America as part of the field validation will be described, including details about the sensors and data acquisition system. Data cleaning and analysis methodologies will be discussed, along with early observations from the winter 2022-2023, spring and summer performance periods, and an assessment of non-energy metrics through pre- and post-installation homeowner surveys. Challenges uncovered and lessons learned throughout the process will also be discussed. Finally, the paper will discuss next steps for the second winter assessment period, areas needing additional research, and potential applications of the data collected and analyzed through this work.

Mendon, Vrushali V.↗

Driving the Shift to Energy-Efficient and Climate-Responsible Commercial Refrigeration Equipment in Chile

This report provides an overview of global and Chile-specific market trends, technological advancements, and policy developments related to commercial refrigeration equipment, with an emphasis on refrigerated display cabinets. Section 2 examines CRE market trends at the global and Chilean levels. Section 3 presents CRE energy consumption and the latest technological options for improving energy performance. It also discusses low global warming potential (GWP)1 refrigerant options for CRE. Section 4 provides a cost-effectiveness analysis. Section 5 reviews other regional energy efficiency standards and labeling programs and offers potential standard requirements for Chile. Section 6 concludes the report by summarizing key findings and conclusions. Finally, Appendix A provides detailed guidelines intended as a starting point to inform policies and programmes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Searching for eco-friendly working fluids for an ejector-driven heat pump for domestic water heating

This study searches for refrigerants with low global warming potential (GWP) and zero ozone depletion potential (ODP) for an ejector heat pump water heater (EHPWH). Several criteria are set, and R1336mzz(Z), R601a, R1233zd(E), R1224yd(Z), R1234ze(Z), and R600a are shortlisted. A theoretical model is built to study the performance of EHPWH and the corresponding ejector design at different operating conditions. For the same ejector design, a refrigerant with a high specific heat ratio produces a high entrainment ratio and heating COP. This is because the expansion wave angle in the ejector is small for refrigerants with a high specific heat ratio, allowing more mass flow rate to be entrained. A higher entrainment ratio does not necessarily correlate to a high COP because the saturation curve of the tested refrigerants is not the same. Results show that the heating COP of R601a is the highest, but it is extremely flammable. R1224yd(Z) and R1234ze(Z) are the most candidates for EHPWH when the trade-off between the COP and safety criteria is considered. The results presented in this work could help building an EHPWH using eco-friendly refrigerants.

Mohammed, Ramy H.↗

Reliability of Copper Inverse Opal Surfaces for Extreme-Heat-Flux Micro-Coolers in Low-Global-Warming-Potential Refrigerant R-1233zd Pool Boiling Experiments

This presentation provides a brief snapshot of the InterPACK paper InterPACK2023-113781. The paper explores copper inverse opal (CIO) surface reliability in pool boiling experiments in water and a new, low-global-warming-potential (GWP = 1) hydrofluoroolefin (HFO) refrigerant R-1233zd. The CIO-based structure is intended to develop enhanced two-phase heat transfer surfaces for extreme-heat-flux (approximately 1 kW/cm2) micro-coolers. In this study, a limited number of pool boiling experiments were performed using water and HFO-1233zd fluid, and the reliability of the CIO-based surfaces was evaluated. Critical heat flux (CHF) values in HFO-1233zd at 40 Degrees Celsius to 45 Degrees Celsius saturation temperatures and the corresponding saturation pressures were also measured. The CHF values with the refrigerant are significantly lower compared to those with water, but the refrigerant allows for a wider usable temperature range in the end application of the micro-coolers and is not limited to data centers with controlled ambient conditions. Reliability experiments with CIO surface samples - involving pool boiling with water on the CIO surfaces for approximately 48 hours and with HFO-1233zd for 144 hours - showed no structural degradation of the enhanced surface or any significant performance drop in heat transfer coefficients. The CIO surface samples in water were oxidized, most likely due to the presence of air in water and in the experimental vessel.

critical heat flux↗

Field Measurement of Central CO2 Heat Pump Water Heater for Multifamily Retrofit

Domestic hot water heating of multifamily buildings accounts for a substantial portion of the energy load of existing buildings. This load is made up of both the energy required to produce hot water and the energy needed to maintain the temperature of the heated water within a building’s distribution piping so that heat can be promptly delivered to building occupants as needed. Properly designed heat pump water heater (HPWH) systems have the ability to improve efficiency in both water heating and temperature control operations. Further, CO2 heat pump technology reflects a shift away from traditional refrigerants and toward refrigerants with low global warming potential (GWP). In this paper’s case study, a design consisting of multiple CO2 heat pump water heaters (commonly used in single-family homes) with a novel “swing tank” was proposed to meet the demand for domestic hot water heating and recirculation loop temperature maintenance. The proposed design was applied to the retrofit of a 60-unit, low-rise, multi-family building located in the Pacific Northwest of the United States. The purpose of this paper is to verify the performance of the system including the proposed “swing tank” in a centralized SHW system using CO2 HPWH. It also provides practical information and lessons learned from the retrofit project. Long-term monitoring data showed that the system had a coefficient of performance (COP) of three or greater and provided an average of 20 gallons of hot water per day per apartment. The results of this work indicate that residential-scale CO2 HPWH equipment and a “swing tank” design can efficiently provide domestic hot water heating and temperature maintenance for mid-sized multifamily buildings.

Banks, Adria↗

Elucidating the challenges in extracting ultra-slow flame speeds in a closed vessel - A CH 2 F 2 microgravity case study using optical and pressure-rise data

Refrigerants with a low global warming potential (GWP) possess mild flammability. Hence, a fundamental understanding of their combustion characteristics is required to assess their fire-hazardous potential. The laminar burning velocity is one fundamental property to describe these under safety evaluation aspects. However, measuring laminar burning velocities for slow-burning components, such as low-GWP alternatives, is challenging. This is due to influencing effects such as buoyant flame deformation, stretch, radiation, and confinement, especially at the flammability limits. Here, in the present study, we investigated near-limit flames of the representative refrigerant difluoromethane (CH 2 F 2 ) with nitrogen-enriched oxidizer mixtures to elucidate the potentials and limitations at ultra-slow flame speeds of two widely used flame speed measurement methods in the closed vessel configuration: the optical flame speed measurement in the early quasi-isobaric regime and the flame speed determination from the pressure-rise during the later phase of the isochoric combustion process. Experiments were performed under terrestrial- and microgravity, conducted in a specially designed setup suitable for drop tower applications, using both methods in parallel. Recommendations for the extraction of flame speed data are derived from the non-buoyant reference investigations under microgravity and transferred to ultra-slow flames at terrestrial gravity. Near-limit flames under microgravity were found to be significantly affected by stretch effects for the optical method so that flame speed extrapolations to unstretched conditions are prone to errors. Stretch also affects the pressure method’s lower evaluation limit, and errors can be estimated by combining flame speed data from the pressure method and Markstein lengths from optical experiments.

42 ENGINEERING↗

Flow condensation heat transfer performance of natural and emerging synthetic refrigerants

There is great interest in predicting flow condensation heat transfer for lower global warming potential (GWP) fluids. This paper analyzes the efficacy of common flow condensation correlations developed for particular fluids in order to identify their suitability to predict heat transfer performance of low GWP fluids. Condensation heat transfer data were extracted from the literature, including 19 papers and 1,473 data points for natural refrigerants [i.e., ammonia (R717), CO 2 (R744), propane (R290), isobutane (R600a)] and 35 papers and 5,030 data points for synthetic refrigerants [i.e., R12, R1234yf, R1234ze(E), R1234ze(Z), R22, R32, R41, R123, R125, R134a, R142b, R152a, R161, R404A, R410A, R448A, R449A, R450A, R452B, R454C, R455A, R513A] encompassing tube diameters of 0.1–11.5 mm, mass fluxes of 55–1200 kg/m2s, and saturation temperatures of -25°C–65°C. Correlations analyzed included Akers et al. (1959), Cavallini et al. (2006, 2011), Kim and Mudawar (2013), Macdonald and Garimella (2016), Shah (1979, 2009, 2013, 2016) and Traviss et al. (1973) for smooth tubes and Chamra et al. (2005) and Kedzierski and Goncalves (1999) for enhanced tubes. Since most studies did not report wall temperature, correlations which relied on wall temperature directly or indirectly were excluded from the analysis. For synthetic refrigerants, mean average error (MAE) ranged from 6%–257%, and Cavallini et al. (2011) and Kim and Mudawar (2013) were the best predictors for emerging synthetic refrigerants. Furthermore, the Kim and Mudawar (2013) correlation was found to best predict the heat transfer performance for propane and R600a data, but most correlations did not accurately predict ammonia and CO 2 flow condensation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-objective optimization of low-GWP mixture composition and heat exchanger circuitry configuration for improved system performance and reduced refrigerant flammability

The recently introduced hydrofluoroolefin (HFO) refrigerants, including R1234yf and R1234ze(E), have significantly lower global warming potentials (GWPs) than traditional hydrofluorocarbon (HFC) refrigerants like R410A. However, prior tests show that direct drop-in of pure R1234yf or R1234ze(E) into equipment designed for R410A results in a decrease in heat exchanger capacity and the system coefficient of performance. The primary reason is the lower in-tube heat transfer performance of R1234yf and R1234ze(E) compared with that of R410A. To address this issue, previous studies have mixed the mildly flammable HFC R32 with HFOs to improve system performance, with HFC R125 also added to suppress flammability. Previous studies selected compositions based on simple cycle analyses and did not consider modifications of the heat exchanger circuitry configuration to adapt to the new refrigerants. This study presents a novel multi-objective optimization approach to design a refrigerant composition that maximizes energy efficiency within flammability and GWP limits. The approach in this work simultaneously optimizes mixture composition and heat exchanger circuitry configuration. A case study on a rooftop unit indicates that, compared with mixture-only optimization, simultaneous optimization of mixture and heat exchanger circuitry yields a 5.9% improvement in cycle efficiency and a 48.6% reduction in refrigerant flammability with a GWP of 268. Circuitry optimization using refrigerants with different temperature glides shows that the larger the temperature glide is, the larger EER improvement is obtained. The results show that zeotropic blends with a large temperature glide are more sensitive to the refrigerant circuitry than pure refrigerants and may suffer significant performance degradation with subpar heat exchanger circuitry design. The proposed optimization approach is generally applicable to mixtures with any number of components. Using this approach to design a HVAC system can yield higher system efficiency within flammability and GWP constraints.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Comprehensive Review of Working Fluids for High-Temperature Heat Pumps: History, Selection, and Evaluation

High-temperature heat pumps (HTHPs) are essential for enhancing energy efficiency across various industrial applications, especially in terms of integrating with renewable energy sources and recovering waste heat. This article thoroughly investigates suitable working fluids for HTHPs, highlighting the evolution from traditional refrigerants to contemporary alternatives with low global warming potential (GWP). It proposes comprehensive selection criteria for these working fluids, pre-selects low-GWP working fluids, and outlines a screening methodology. The pre-selected low-GWP working fluids are evaluated for applications in three typical industrial scenarios involving HTHPs. Furthermore, this study demonstrates that regulatory compliance and environmental impacts significantly influence the development of next-generation refrigerants. The choice of working fluids is closely linked to the types of vapor compression cycles, tailored to the specific industrial applications for HTHPs. This study emphasizes areas for future research, including the development of innovative working fluids; integrated strategies that account for performance, safety, and regulatory standards; alignment of HTHP components; exploration of natural working fluids; and broadening the applications of existing working fluids.

Compression↗

Experimental Study on Flow Condensation of Low Global Warming Potential Refrigerants in a Micro-fin Aluminum Tube

This study investigates the dynamic shifts in refrigerant technologies driven by environmental regulations, particularly emphasizing low global warming potential (GWP). Moreover, there is a rising trend in the adoption of aluminum tubes with internal axial micro-fin structures in heat exchangers to reduce costs. The research focuses on the condensation process within an expanded axial micro-fin aluminum tube with a 5.96 mm fin-tip diameter. Various refrigerants are analyzed, including both single compounds (R-32, R-1234yf, R-1234ze(E)) and zeotropic mixtures (R-454B, R-454C, R-455A). Experimental procedures cover a range of condensation temperatures (35~45 °C), reduced pressures (0.21~0.55), and mass fluxes (150~350 kg/(m² s)), providing crucial data on heat transfer coefficients (HTC) and frictional pressure gradient (FPG). This data is particularly significant for high-glide refrigerants and is instrumental in the design of advanced air conditioning and refrigeration systems aimed at mitigating global warming.

Hu, Yifeng↗

High-Performance, Low Environmental Impact Refrigerants

Refrigerants used in process and facilities systems in the US include R-12, R-22, R-123, R-134a, R-404A, R-410A, R-500, and R-502. All but R-134a, R-404A, and R-410A contain ozone-depleting substances that will be phased out under the Montreal Protocol. Some of the substitutes do not perform as well as the refrigerants they are replacing, require new equipment, and have relatively high global warming potentials (GWPs). New refrigerants are needed that addresses environmental, safety, and performance issues simultaneously. In efforts sponsored by Ikon Corporation, NASA Kennedy Space Center (KSC), and the US Environmental Protection Agency (EPA), ETEC has developed and tested a new class of refrigerants, the Ikon (registered) refrigerants, based on iodofluorocarbons (IFCs). These refrigerants are nonflammable, have essentially zero ozone-depletion potential (ODP), low GWP, high performance (energy efficiency and capacity), and can be dropped into much existing equipment.

McCullough, E. T.↗

Building Technologies Office 03.02.02.38 Milestone Report — Technology Options for Low Environmental Impact Air-Conditioning and Refrigeration Systems

Due to increasing concerns about global warming, various environmental regulations will eventually phase out refrigerants used in air conditioning and refrigeration systems (e.g., R-410A, R-404A). Several refrigerants have been proposed as replacements, offering a variety of global warming potential (GWP), levels of energy efficiency and flammability. Some of these options are synthetic HFC/HFO mixtures such as R-454C and R-455A while other are commonly called naturals such as R-290 (Propane) and R-744 (Carbon Dioxide). This study discusses the merits of the leading options for air Conditioning and refrigeration systems. The fundamental requirements (environmental, performance, safety) are employed to fairly evaluate these options. Performance data and Life Cycle analysis results for these options are presented. Overall, this study provides information needed to judge the prospects of getting adequate replacement for R-410A and R-404A in a long-term sustainable basis.

42 ENGINEERING↗

A Propane Hydronic Heat Pump with Energy Storage

Propane is an environment-friendly refrigerant, having a 20-year GWP (global warming potential) of 0.072 and a 100-year GWP of 0.02, as compared to R-410A having a GWP > 2000. It has superior thermodynamic cycle performance and heat transfer characteristics. However, propane is classified as a A3 refrigerant, which is highly flammable, and not allowed to be used indoor if the system charge is higher than 150 grams. It is a challenge to use propane in residential applications requiring a rated capacity larger than 10 k Watts. A hydronic heat pump, i.e., containing propane in an outdoor unit and distributing the cooling and heating capacity through a hydronic coil to the indoor space addresses the flammability issue, while maintaining a high efficiency. We developed a hydronic heat pump with propane, it uses a two-stage compressor, a brazed plate indoor heat exchanger, and a microchannel outdoor heat exchanger. It achieves a rated cooling capacity larger than 10 k Watts, and a cooling SEER (cooling seasonal energy efficiency rating) > 16.0 (cooling seasonal COP > 4.7) and a heating HSPF (heating seasonal performance factor) > 9.5 (heating seasonal COP > 2.78), while requiring a system charge < 1200 grams. Additionally, the hydronic heat pump was evaluated in a laboratory water heating loop to heat a 50-gallon water tank in a full condensing mode. Experiments of heating the tank water from 58F(14.4°C) to 150F(65.6°C) were conducted under ambient temperatures from 17F(-8.3°C) to 75F(23.9°C), at the compressor high and low stages.

Shen, Bo↗