Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC FIELDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Methods and systems for low to ultra-low magnetic field nuclear magnetic resonance for detecting chemical nerve agents

A nuclear magnetic resonance (NMR) system is configured to detect chemical threat material. The system comprises a magnet configured to generate a magnetic field of about 300 millitesla or less; and a probe configured to detect nuclear relaxation of at least two nuclei selected from the group consisting of 1H, 19F, 31P and 14N, and detect the spin density of nuclei selected from the group consisting of 1H, 19F, 31P and 14N, following excitation.

Williams, Robert F.↗

Characterization of magnetic field lines in connection with the transport of field lines in Beltrami magnetic fields

Single and double curl Beltrami magnetic fields are studied numerically in connection with their transport properties and the results are compared and analyzed by characterizing the magnetic field lines. In the phase space of single curl Beltrami field, islands of regular field lines are embedded into the chaotic sea. Whereas the field lines for certain solutions of double curl Beltrami field are chaotic over the entire space. Due to the presence of regular islands in phase space, the chaotic trajectories show stickiness phenomena which is characterized by the distribution of a chaotic field line. The dynamical traps in chaotic orbits due to stickiness phenomena are also characterized by the distribution of finite distance Lyapunov exponents. Finally recurrence time distribution of chaotic trajectories is plotted to understand their global behaviour.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ac magnetic fields

Magnetic fluctuations observed by ground observatories, suggesting large amplitude waves as field line resonances driven by magnetopause motion

Holzer, R. E.↗

Efficient magnetic fields for supporting toroidal plasmas

The magnetic field that supports tokamak and stellarator plasmas must be produced by coils well separated from the plasma. However, the larger the separation, the more difficult it is to produce a given magnetic field in the plasma region, so plasma configurations should be chosen that can be supported as efficiently as possible by distant coils. The efficiency of an externally generated magnetic field is a measure of the field's shaping component magnitude at the plasma compared to the magnitude near the coils; the efficiency of a plasma equilibrium can be measured using the efficiency of the required external shaping field. Counterintuitively, plasma shapes with low curvature and spectral width may have low efficiency, whereas plasma shapes with sharp edges may have high efficiency. Two precise measures of magnetic field efficiency, which correctly identify such differences in difficulty, will be examined. These measures, which can be expressed as matrices, relate the externally produced normal magnetic field on the plasma surface to the either the normal field or current on a distant control surface. A singular value decomposition (SVD) of either matrix yields an efficiency ordered basis for the magnetic field distributions. Calculations are carried out for both tokamak and stellarator cases. For axisymmetric surfaces with circular cross-section, the SVD is calculated analytically, and the range of poloidal and toroidal mode numbers that can be controlled to a given desired level is determined. If formulated properly, these efficiency measures are independent of the coordinates used to parameterize the surfaces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of the Strain Dependence of Critical Current of Commercial REBCO Tapes at 15 T Between 4.2 and 40 K for High Field Magnets

Interest for high magnetic fields (>16 T) for applications in high energy physics (HEP) and fusion machines, requires the development of high current cables capable to withstand the large forces, mechanical and electromagnetic, experienced during manufacturing and operations. The critical current (I c ) of REBCO tapes depends on strain, magnetic fields, and operational temperatures. Understanding how these parameters affect the I c of the conductor will be critical to develop robust high-current REBCO cables. However, there are limited reports on the strain dependence of I c , in particular at high fields and elevated temperatures relevant for future high-field compact fusion reactor magnets. We present here I c of commercial REBCO tapes measured as a function of compressive and tensile strain (between -0.6% and +0.65%) at high magnetic fields (12 and 15 T) and different temperatures (within 4.2-40 K). Results at 4.2 and 20 K showed less than 5% reduction in the normalized I c at high strain, while a stronger strain dependence was observed at 40 K. Samples tested at 12 T and 4.2 K showed similar strain dependence as 15 T and 4.2 K. In all tested conditions, the tape experienced reversible I c reduction in both tension and compression. Finite element analysis was used to predict the residual thermal strain accumulated in the REBCO layer prior of testing to account for the effect of the cooldown. A method was also developed to account for the current sharing observed between the sample and the sample holder during the ramp of the current. Our results provide useful input for the development of high-field fusion and HEP magnets using REBCO conductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time and Magnetic Field Variations of Magnetic Structure in the Triangular Lattice Magnet Ca 3 Co 2 O 6

In a previous study, the long-time variation of the magnetic structure was investigated in the triangular lattice compound Ca 3 Co 2 O 6 in zero magnetic field. In this study, the magnetic field and time variations of the magnetic structure have been studied by magnetization and neutron scattering measurements. The magnetization curve shows a multistep increase, which suggests the presence of successive transitions to different magnetic structures. However, magnetic Bragg peaks corresponding to the long-period antiferromagnetic structure persist up to a high magnetic field close to saturation magnetization. After the magnetic field is removed, a diffuse magnetic scattering signal due to short-range correlations grows with time instead of the Bragg peaks owing to the antiferromagnetic structure in the initial state. A model to account for the magnetic field and time variations of the magnetic structure is presented.

36 MATERIALS SCIENCE↗

Determining the exchange parameters of spin-1 metal-organic molecular magnets in pulsed magnetic fields

We nave measured the high-field magnetization of a number of Ni-based metal-organic molecular magnets. These materials are self-assembly coordination polymers formed from transition metal ions and organic ligands. The chemistry of the compounds is versatile allowing many structures with different magnetic properties to be formed. These studies follow on from previous measurements of the Cu-based analogues in which we showed it was possible to extract the exchange parameters of low-dimensional magnets using pulsed magnetic fields. In our recent experiments we have investigated the compound (Ni(HF{sub 2})(pyz){sub 2})PF{sub 6}, where pyz = pyrazine, and the Ni-ions are linked in a quasi-two-dimensional (Q2D) square lattice via the pyrazine molecules, with the layers held together by HF{sub 2} ligands. We also investigated Ni(NCS){sub 2}(pyzdo){sub 2}, where pyzdo = pyrazine dioxide. The samples are grown at Eastern Washington University using techniques described elsewhere. Measurements are performed at the pulsed magnetic field laboratory in Los Alamos. The magnetization of powdered samples is determined using a compensated coil magnetometer in a 65 T short pulse magnet. Temperatures as low as 500 mK are achievable using a {sup 3}He cryostat. The main figure shows the magnetization of the spin-1 [Ni(HF{sub 2})(pyz){sub 2}]PF{sub 6} compound at 1.43 K. The magnetization rises slowly at first, achieving a rounded saturation whose midpoint is around 19 T. A small anomaly is also seen in the susceptibility at low fields ({approx}3 T), which might be attributed to a spin-flop transition. In contrast, the spin-1/2 [Cu(HF{sub 2})(pyz){sub 2}]PF{sub 6} measured previously has a saturation magnetization of 35.5 T and a strongly concave form of M(B) below this field. This latter compound was shown to be a good example of a Q2D Heisenberg antiferromagnet with the strong exchange coupling (J{sub 2D} = 12.4 K, J{sub {perpendicular}}/J{sub 2D} {approx} 10{sup -2}) directed along the Cu-pyz-Cu directions. The structure of the two compounds is similar, but in the case of the Cu-compound the Cu-Cu pathways are linear, whereas in the Ni-compound they are kinked. The pulsed-field data combined with information from temperature-dependent susceptibility, muon-spin rotation, electron-spin resonance and ligand-field calculations suggest that, far from being magnetically Q2D, the Ni-compound is fairly one-dimensional with the dominant exchange (J{sub 1D} = 3.1 K and J{sub {perpendicular}}/J{sub 1D} = 0.63) directed along the Ni-FHF-Ni direction. Ni(NCS){sub 2}(pyzdo){sub 2} was also investigated. Previous ultra-high field measurements using the 100 T magnet have shown that this compound has a saturation field close to 80 T. The purpose of the present studies is to map out the phase diagram of this material at mid-range fields. The data are shown in the inset to the figure. This continuing project probes the ability of organic ligands to mediate magnetic exchange, the link between structure, dimensionality and bulk magnetic properties, as well as the role of spin number in quantum magnets. Ultimately the investigations aim to determine to what extent it is possible to produce self-assembly molecular materials with tailor-made magnetic characteristics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the relation between photospheric flow fields and the magnetic field distribution on the solar surface

Using the technique of local correlation tracking on a 28 minute time sequence of white-light images of solar granulation, the horizontal flow field on the solar surface is measured. The time series was obtained by the Solar Optical Universal Polarimeter (SOUP) on Spacelab 2 (Space Shuttle flight 51-F) and is free from atmospheric blurring and distortion. The SOUP flow fields have been compared with carefully aligned magnetograms taken over a nine hour period at the Big Bear Solar Observatory before, during, and after the SOUP images. The flow field and the magnetic field agree in considerable detail: vectors which define the flow of the white-light intensity pattern (granulation) point toward magnetic field regions, magnetic fields surround flow cells, and magnetic features move along the flow arrows. The projected locations of free particles ('corks') in the measured flow field congregate at the same locations where the magnetic field is observed.

Simon, George W.↗

EFFECTS OF THE NON-RADIAL MAGNETIC FIELD ON MEASURING MAGNETIC HELICITY TRANSPORT ACROSS THE SOLAR PHOTOSPHERE

It is generally believed that the evolution of magnetic helicity has a close relationship with solar activity. Before the launch of the Solar Dynamics Observatory (SDO), earlier studies had mostly used Michelson Doppler Imager/SOHO line of sight (LOS) magnetograms and assumed that magnetic fields are radial when calculating the magnetic helicity injection rate from photospheric magnetograms. However, this assumption is not necessarily true. Here we use the vector magnetograms and LOS magnetograms, both taken by the Helioseismic and Magnetic Imager on SDO, to estimate the effects of the non-radial magnetic field on measuring the magnetic helicity injection rate. We find that: (1) the effect of the non-radial magnetic field on estimating tangential velocity is relatively small; (2) when estimating the magnetic helicity injection rate, the effect of the non-radial magnetic field is strong when active regions are observed near the limb and is relatively weak when active regions are close to disk center; and (3) the effect of the non-radial magnetic field becomes minor if the amount of accumulated magnetic helicity is the only concern.

79 ASTRONOMY AND ASTROPHYSICS↗

Central Magnetic Field of a Magnetic White Dwarf Star

Observations of over-luminous Type 1a supernovae have prompted researchers to come up with various hypotheses in order to explain them. One hypothesis is based on the explosion of a progenitor super-massive magnetic white dwarf star. These stars are assumed to have very strong magnetic fields inside of them. However, there is a lack of analytic proof of the existence of such magnetic fields in the magnetic white dwarf stars. In this work, we plan to address an analytic proof of the existence of very strong magnetic fields in the center of these magnetic white dwarfs. We will see that for a one Landau-level white dwarf star, with central density 10{sup 9}--10{sup 11} g cm{sup −3}, it is possible to have central magnetic fields of the order of 10{sup 13}--10{sup 15}G at least. In the presence of strong magnetic fields, the threshold densities chosen for this work that correspond to instabilities due to general relativity and pycnonuclear reactions have been found to increase so that the matter does not acquire instability at such central densities.

79 ASTRONOMY AND ASTROPHYSICS↗

Probing High Temperature Superconductors with Magnetometry in Ultrahigh Magnetic Fields

The objective of this research is to investigate the high-field magnetic properties of high temperature superconductors, materials that conduct electricity without loss. A technique known as high-resolution torque magnetometry that was developed to directly measure the magnetization of high temperature superconductors. This technique was implemented using the 65 Tesla pulsed magnetic field facility that is part of the National High Magnetic Field Laboratory at Los Alamos National Laboratory. This research addressed unanswered questions about the interplay between magnetism and superconductivity, determine the electronic structure of high temperature superconductors, and shed light on the mechanism of high temperature superconductivity and on potential applications of these materials in areas such as energy generation and power transmission. Further applications of the technology resolve the novel physical phenomena such as correlated topological insulators, and spin liquid state in quantum magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

System and method for magnetic current density imaging at ultra low magnetic fields

Preferred systems can include an electrical impedance tomography apparatus electrically connectable to an object; an ultra low field magnetic resonance imaging apparatus including a plurality of field directions and disposable about the object; a controller connected to the ultra low field magnetic resonance imaging apparatus and configured to implement a sequencing of one or more ultra low magnetic fields substantially along one or more of the plurality of field directions; and a display connected to the controller, and wherein the controller is further configured to reconstruct a displayable image of an electrical current density in the object. Preferred methods, apparatuses, and computer program products are also disclosed.

60 APPLIED LIFE SCIENCES↗

Spatial heterodyne spectroscopy for fast local magnetic field measurements of magnetized fusion plasmas

A novel spectroscopy diagnostic for measuring internal magnetic fields in high temperature magnetized plasmas has been developed. It involves spectrally resolving the Balmer- α (656 nm) neutral beam radiation split by the motional Stark effect with a spatial heterodyne spectrometer (SHS). The unique combination of high optical throughput (3.7 mm 2 sr) and spectral resolution (δλ ~ 0.1 nm) allows these measurements to be made with time resolution $\ll$1 ms. The high throughput is effectively utilized by incorporating a novel geometric Doppler broadening compensation technique in the spectrometer. The technique significantly reduces the spectral resolution penalty inherent to using large area, high-throughput optics while still collecting the large photon flux provided by such optics. In this work, fluxes of order 10 10 s –1 support the measurement of deviations of <5 mT (Δ λ Stark ~ 10 –4 nm) in the local magnetic field with 50 µs time resolution. Example high time resolution measurements of the pedestal magnetic field throughout the ELM cycle of a DIII-D tokamak plasma are presented. Local magnetic field measurements give access to the dynamics of the edge current density, which is essential to understanding stability limits, edge localized mode generation and suppression, and predicting performance of H-mode tokamaks.

47 OTHER INSTRUMENTATION↗