Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC SUSCEPTIBILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Countering Solutal Buoyant Convection with High Magnetic Fields

An important component in biotechnology, particularly in the area of protein engineering and rational drug design is the knowledge of the precise three-dimensional molecular structure of proteins. The quality of structural information obtained from X-ray diffraction methods is directly dependent on the degree of perfection of the protein crystals. As a consequence, the growth of high quality macromolecular crystals for diffraction analyses has been the central focus for biochemist, biologists, and bioengineers. Macromolecular crystals are obtained from solutions that contain the crystallizing species in equilibrium with higher aggregates, ions, precipitant, other possible phases of the protein, foreign particles, the walls of the container, and a likely host of other impurities. By changing transport modes in general, i.e., reduction of convection and sedimentation, as is achieved in microgravity, we have been able to dramatically effect the movement and distribution of macromolecules in the fluid, and thus their transport, formation of crystal nuclei, and adsorption to the crystal surface. While a limited number of high quality crystals from space flights have been obtained, as the recent National Research Council (NRC) review of the NASA microgravity crystallization program pointed out, the scientific approach and research in crystallization of proteins has been mainly empirical yielding inconclusive results. We postulate that we can reduce convection in ground-based experiments and we can understand the different aspects of convection control through the use of strong magnetic fields and field gradients. We postulate that limited convection in a magnetic field will provide the environment for the growth of high quality crystals. The approach exploits the variation of fluid magnetic susceptibility with concentration for this purpose and the convective damping is realized by appropriately positioning the crystal growth cell so that the magnetic susceptibility force counteracts terrestrial gravity. The general objective is to test the hypothesis of convective control using a strong magnetic field and magnetic field gradient and to understand the nature of the various forces that come into play. Specifically we aim to delineate causative factors and to quantify them through experiments, analysis and numerical modeling. The paper will report on the current status of the investigation and discuss results from the experimental and modeling efforts.

Ramachandran, N.↗

Using Strong Magnetic Fields to Control Solutal Convection

An important component in biotechnology, particularly in the area of protein engineering and rational drug design is the knowledge of the precise three-dimensional molecular structure of proteins. The quality of structural information obtained from X-ray diffraction methods is directly dependent on the degree of perfection of the protein crystals. As a consequence, the growth of high quality macromolecular crystals for diffraction analyses has been the central focus for biochemists, biologists, and bioengineers. Macromolecular crystals are obtained from solutions that contain the crystallizing species in equilibrium with higher aggregates, ions, precipitants, other possible phases of the protein, foreign particles, the walls of the container, and a likely host of other impurities. By changing transport modes in general, i.e., reduction of convection and sedimentation, as is achieved in microgravity , we have been able to dramatically affect the movement and distribution of macromolecules in the fluid, and thus their transport, formation of crystal nuclei, and adsorption to the crystal surface. While a limited number of high quality crystals from space flights have been obtained, as the recent National Research Council (NRC) review of the NASA microgravity crystallization program pointed out, the scientific approach and research in crystallization of proteins has been mainly empirical yielding inconclusive results. We postulate that we can reduce convection in ground-based experiments and we can understand the different aspects of convection control through the use of strong magnetic fields and field gradients. We postulate that limited convection in a magnetic field will provide the environment for the growth of high quality crystals. The approach exploits the variation of fluid magnetic susceptibility with concentration for this purpose and the convective damping is realized by appropriately positioning the crystal growth cell so that the magnetic susceptibility force counteracts terrestrial gravity. The general objective is to test the hypothesis of convective control using a strong magnetic field and magnetic field gradient and to understand the nature of the various forces that come into play. Specifically we aim to delineate causative factors and to quantify them through experiments, analysis and numerical modeling. The paper will report on the experimental results using paramagnetic salts and solutions in magnetic fields and compare them to analytical predictions.

Ramachandran, N.↗

Magnetic Control of Convection during Protein Crystallization

An important component in biotechnology, particularly in the area of protein engineering and rational drug design is the knowledge of the precise three-dimensional molecular structure of proteins. The quality of structural information obtained from X-ray diffraction methods is directly dependent on the degree of perfection of the protein crystals. As a consequence, the growth of high quality macromolecular Crystals for diffraction analyses has been the central focus for bio-chemists, biologists, and bioengineers. Macromolecular crystals are obtained from solutions that contain the crystallizing species in equilibrium with higher aggregates, ions, precipitants, other possible phases of the protein, foreign particles, the walls of container, and a likely host of other impurities. By changing transport modes in general, i.e., reduction of convection and Sedimentation as is achieved in "microgravity", we have been able to dramatically affect the movement and distribution of macromolecules in the fluid, and thus their transport, f o d o n of crystal nuclei, and adsorption to the crystal surface. While a limited number of high quality crystals from space flights have been obtained, as the recent National Research Council (NRC) review of the NASA microgravity crystallization program pointed out, the scientific approach and research in crystallization of proteins has been mainly empirical yielding inconclusive results. We postulate that we can reduce convection in ground-based experiments and we can understand the different aspects of convection control through the use of strong magnetic fields and field gradients. We postulate that limited convection in a magnetic field will provide the environment for the growth of high quality crystals. The approach exploits the variation of fluid magnetic susceptibility with counteracts on for this purpose and the convective damping is realized by appropriately positioning the crystal growth cell so that the magnetic susceptibility force counteract terrestrial gravity. The genera1 objective is to test the hypothesis of convective control using a strong magnetic field and magnetic field gradient and to understand the nature of the various forces that come into play. Specifically we aim to delineate causative factors and to quantify them through experiments, analysis and numerical modeling. The paper will report on the experimental results using paramagentic salts and solutions in magnetic fields and compare them to analyticalpr~ctions.

Ramachandran, N.↗

Fast Characterization of Magnetic Impurities in Single-Wall Carbon Nanotubes

We have demonstrated that the magnetic susceptibility measurement is a non-destructive, fast and accurate method to determine the residual metal catalysts in a few microgram single-wall carbon nanotube (SWCNT) sample. We have studied magnetic impurities in raw and purified SWCNT by magnetic susceptibility measurements, transmission electron microscopy, and thermogravimetry. The data suggest that the saturation magnetic moment and the effective field, which is caused by the interparticle interactions, decreases and increases respectively with the decrease of the particle size. Methods are suggested to overcome the uncertainty associated.

Chen, Feng↗

Magnetic properties of lunar samples returned by Luna 16 automatic station

Results of measuring the specific magnetic susceptibility of regolith are presented. The data indicate that regolith samples from the Sea of Tranquillity and the Sea of Fertility are similar in order of magnitude of the specific magnetic susceptibility. Several stony meteorites of subgroup L have a similar value of this quantity. After comparison with artificial analogs, it can be concluded that the bulk content of ferromagnetic minerals in regolith samples is 3 to 4 percent.

Gorshkov, E. S.↗

Temperature-dependent magnetic properties of individual glass spherules, Apollo 11, 12, and 14 lunar samples.

Magnetic susceptibility of 11 glass spherules from the Apollo 14 lunar fines have been measured from room temperature to 4 K. Data taken at room temperature, 77 K, and 4.2 K, show that the soft saturation magnetization was temperature independent. In the temperature range 300 to 77 K the temperature-dependent component of the magnetic susceptibility obeys the Curie law. Susceptibility measurements on these same specimens and in addition 14 similar spherules from the Apollo 11 and 12 mission show a Curie-Weiss relation at temperatures less than 77 K with a Weiss temperature of 3-7 degrees in contrast to 2-3 degrees found for tektites and synthetic glasses of tektite composition. A proposed model and a theoretical expression closely predict the variation of the susceptibility of the glass spherules with temperature.

Thorpe, A. N.↗

Multistage Magnetic Separator of Cells and Proteins

The multistage electromagnetic separator for purifying cells and magnetic particles (MAGSEP) is a laboratory apparatus for separating and/or purifying particles (especially biological cells) on the basis of their magnetic susceptibility and magnetophoretic mobility. Whereas a typical prior apparatus based on similar principles offers only a single stage of separation, the MAGSEP, as its full name indicates, offers multiple stages of separation; this makes it possible to refine a sample population of particles to a higher level of purity or to categorize multiple portions of the sample on the basis of magnetic susceptibility and/or magnetophoretic mobility. The MAGSEP includes a processing unit and an electronic unit coupled to a personal computer. The processing unit includes upper and lower plates, a plate-rotation system, an electromagnet, an electromagnet-translation system, and a capture-magnet assembly. The plates are bolted together through a roller bearing that allows the plates to rotate with respect to each other. An interface between the plates acts as a seal for separating fluids. A lower cuvette can be aligned with as many as 15 upper cuvette stations for fraction collection during processing. A two-phase stepping motor drives the rotation system, causing the upper plate to rotate for the collection of each fraction of the sample material. The electromagnet generates a magnetic field across the lower cuvette, while the translation system translates the electromagnet upward along the lower cuvette. The current supplied to the electromagnet, and thus the magnetic flux density at the pole face of the electromagnet, can be set at a programmed value between 0 and 1,400 gauss (0.14 T). The rate of translation can be programmed between 5 and 2,000 m/s so as to align all sample particles in the same position in the cuvette. The capture magnet can be a permanent magnet. It is mounted on an arm connected to a stepping motor. The stepping motor rotates the arm to position the capture magnet above the upper cuvette into which a fraction of the sample is collected. The electronic unit includes a power switch, power-supply circuitry that accepts 110-Vac input power, an RS-232 interface, and status lights. The personal computer runs the MAGSEP software and controls the operation of the MAGSEP through the RS-232 interface. The status of the power, the translating electromagnet, the capture magnet, and the rotation of the upper plate are indicated in a graphical user interface on the computer screen.

Barton, Ken↗

Formation of Nanophase Iron in Lunar Soil Simulant for Use in ISRU Studies

For the prospective return of humans to the Moon and the extensive amount of premonitory studies necessary, large quantities of lunar soil simulants are required, for a myriad of purposes from construction/engineering purposes all the way to medical testing of its effects from ingestion by humans. And there is only a limited and precious quantity of lunar soil available on Earth (i.e., Apollo soils) - therefore, the immediate need for lunar soil simulants. Since the Apollo era, there have been several simulants; of these JSC-1 (Johnson Space Center) and MLS-1 (Minnesota Lunar Simulant) have been the most widely used. JSC-1 was produced from glassy volcanic tuff in order to approximate lunar soil geotechnical properties; whereas, MLS-1 approximates the chemistry of Apollo 11 high-Ti soil, 10084. Stocks of both simulants are depleted, but JSC-1 has recently gone back into production. The lunar soil simulant workshop, held at Marshall Space Flight Center in January 2005, identified the need to make new simulants for the special properties of lunar soil, such as nanophase iron (np-Fe(sup 0). Hill et al. (2005, this volume) showed the important role of microscale Fe(sup 0) in microwave processing of the lunar soil simulants JSC-1 and MLS-1. Lunar soil is formed by space weathering of lunar rocks (e.g., micrometeorite impact, cosmic particle bombardment). Glass generated during micrometeorite impact cements rock and mineral fragments together to form aggregates called agglutinates, and also produces vapor that is deposited and coats soil grains. Taylor et al. (2001) showed that the relative amount of impact glass in lunar soil increases with decreasing grain size and is the most abundant component in lunar dust (less than 20 micrometer fraction). Notably, the magnetic susceptibility of lunar soil also increases with the decreasing grain size, as a function of the amount of nanophase-sized Fe(sup 0) in impact-melt generated glass. Keller et al. (1997, 1999) also discovered the presence of abundant np-Fe(sup 0) particles in the glass patinas coating most soil particles. Therefore, the correlation of glass content and magnetic susceptibility can be explained by the presence of the np-Feo particles in glass: small particles contain relatively more np-Fe(sup 0) as glass coatings because the surface area versus mass ratio of the grain size is so increased. The magnetic properties of lunar soil are important in dust mitigation on the Moon (Taylor et al. 2005). Thus material simulating this property is important for testing mitigation methods using electromagnetic field. This np- Fe(sup 0) also produces a unique energy coupling to normal microwaves, such as present in kitchen microwave ovens. Effectively, a portion of lunar soil placed in a normal 2.45 GHz oven will melt at greater than 1200 C before your tea will boil at 100 C, a startling and new discovery reported by Taylor and Meek (2004, 2005). Several methods have been investigated in attempts to make nanophase-sized Feo dispersed within silicate glass; like in the lunar glass. We have been successful in synthesizing such a product and continue to improve on our recipe. We have performed extensive experimentation on this subject to date. Ultimately it will probably be necessary to add this np-Fe(sup 0) bearing silicate glass to lunar soil stimulant, like JSC-1, to actually produce the desired magnetic and microwave coupling properties for use in appropriate ISRU experimentation.

Liu, Yang↗

Antiferromagnetic inclusions in lunar glass

The magnetic susceptibility of eleven glass spherules from the Apollo 15, 16, and 17 fines and two specimens of a relatively large glass spherical shell were studied as a function of temperature from room temperature to liquid helium temperatures. All but one specimen showed the presence of antiferromagnetic inclusions. Closely spaced temperature measurements of the magnetic susceptibility below 77 K on five of the specimens showed antiferromagnetic temperature transitions (Neel transitions). With the exception of ilmenite in one specimen, these transitions did not correspond to any transitions in known antiferromagnetic compounds.

Thorpe, A. N.↗

A Classification Table for Achondrites

Classifying chondrites is relatively easy and the criteria are well documented. It is based on mineral compositions, textural characteristics and more recently, magnetic susceptibility. It can be more difficult to classify achondrites, especially those that are very similar to terrestrial igneous rocks, because mineralogical, textural and compositional properties can be quite variable. Achondrites contain essentially olivine, pyroxenes, plagioclases, oxides, sulphides and accessory minerals. Their origin is attributed to differentiated parents bodies: large asteroids (Vesta); planets (Mars); a satellite (the Moon); and numerous asteroids of unknown size. In most cases, achondrites are not eye witnessed falls and some do not have fusion crust. Because of the mineralogical and magnetic susceptibility similarity with terrestrial igneous rocks for some achondrites, it can be difficult for classifiers to confirm their extra-terrestrial origin. We -as classifiers of meteorites- are confronted with this problem with every suspected achondrite we receive for identification. We are developing a "grid" of classification to provide an easier approach for initial classification. We use simple but reproducible criteria based on mineralogical, petrological and geochemical studies. We presented the classes: acapulcoites, lodranites, winonaites and Martian meteorites (shergottite, chassignites, nakhlites). In this work we are completing the classification table by including the groups: angrites, aubrites, brachinites, ureilites, HED (howardites, eucrites, and diogenites), lunar meteorites, pallasites and mesosiderites. Iron meteorites are not presented in this abstract.

Chennaoui-Aoudjehane, H.↗

Limiting depth of magnetization in cratonic lithosphere

Values of magnetic susceptibility and natural remanent magnetization (NRM) of clino-pyroxene-garnet-plagioclase granulite facies lower crustal xenoliths from a kimberlite in west Africa are correlated to bulk geochemistry and specific gravity. Thermomagnetic and alternating-field demagnetization analyses identify magnetite (Mt) and native iron as the dominant magnetic phases (totaling not more than 0.1 vol pct of the rocks) along with subsidiary sulfides. Oxidation states of the granulites are not greater than MW, observed Mt occurs as rims on coarse (about 1 micron) Fe particles, and inferred single domain-pseudosingle domain Mt may be a result of oxidation of fine-grained Fe. The deepest limit of lithospheric ferromagnetism is 95 km, but a limit of 70 km is most reasonable for the West African Craton and for modeling Magsat anomalies over exposed Precambrian shields.

Toft, Paul B.↗

Microstructure and magnetization of doped Y-Ba-Ca-O materials prepared by melt quench and post annealing method

Y-Ba-Cu-O bulk materials prepared using the melt quench and post annealing method were shown to have very high maximum as well as remanent magnetization. Studies were carried out on materials prepared using this method which deviate from the Y:Ba:Cu = 1:2:3 stoichiometry. In one series of materials, only the stoichiometry was changed, in particular by introducing an excess of yttrium. In other cases, dopants including several rare earths were introduced. Effects of variations in composition on microstructure and phase evolution are discussed, as well as effects on the magnetic susceptibility and on the magnetization. The results show that doped materials can exhibit improvements in magnetic properties. Furthermore, the use of dopants sheds light on the role of defect sites in flux pinning.

Hojaji, H.↗

Magnetic Field, Force, and Inductance Computations for an Axially Symmetric Solenoid

The pumping of liquid oxygen (LOX) by magnetic fields (B field), using an array of electromagnets, is a current topic of research and development at Kennedy Space Center, FL. Oxygen is paramagnetic so that LOX, like a ferrofluid, can be forced in the direction of a B field gradient. It is well known that liquid oxygen has a sufficient magnetic susceptibility that a strong magnetic gradient can lift it in the earth's gravitational field. It has been proposed that this phenomenon can be utilized in transporting (i.e., pumping) LOX not only on earth, but on Mars and in the weightlessness of space. In order to design and evaluate such a magnetic pumping system, it is essential to compute the magnetic and force fields, as well as inductance, of various types of electromagnets (solenoids). In this application, it is assumed that the solenoids are air wrapped, and that the current is essentially time independent.

Lane, John E.↗

Thermodynamics of the Heisenberg ferromagnet in an applied magnetic field.

The anisotropic-Heisenberg-ferromagnet formalism developed previously is examined to include an applied magnetic field for the isotropic case in the random-phase approximation. Thermodynamic quantities such as magnetization, susceptibility, and the derivative of magnetization with respect to temperature are studied near the Curie point.

Flax, L.↗

Hematite Versus Magnetite as the Signature for Planetary Magnetic Anomalies?

Crustal magnetic anomalies are the result of adjacent geologic units having contrasting magnetization. This magnetization arises from induction and/or remanence. In a planetary context we now know that Mars has significant crustal magnetic anomalies due to remanent magnetization, while the Earth has some anomalies where remanence can be shown to be important. This picture, however, is less clear because of the nature and the magnitude of the geomagnetic field which is responsible for superimposed induced magnetization. Induced magnetization assumes a magnetite source, because of its much greater magnetic susceptibility when compared with other magnetic minerals. We investigated the TRM (thermoremanent magnetization) acquisition of hematite, in weak magnetic fields up to 1 mT, to determine if the remanent and induced magnetization of hematite could compete with magnetite. TRM acquisition curves of magnetite and hematite show that multi-domain hematite reaches TRM saturation (0.3 - 0.4 A sq m/kg) in fields as low as 100 microT. However, multi-domain magnetite reaches only a few percent of its TRM saturation in a field of 100 microT (0.02 - 0.06 A sq m/kg). These results suggest that a mineral such as hematite and, perhaps, other minerals with significant remanence and minor induced magnetization may play an important role in providing requisite magnetization contrast. Perhaps, and especially for the Mars case, we should reevaluate where hematite and other minerals, with efficient remanence acquisition, exist in significant concentration, allowing a more comprehensive explanation of Martian anomalies and better insight into the role of remanent magnetization in terrestrial crustal magnetic anomalies.

Kletetshka, Gunther↗

The Ivrea zone as a model for the distribution of magnetization in the continental crust

Units are identified within the Ivrea zone of northern Italy exhibiting magnetic susceptibilities greater than 0.0005 cgs, saturation magnetization values above 0.009 emu/cu cm, and Curie points as high as 570-580 C. Amphibolites from the granulite-amphibolite facies transition, and the mafic-ultramafic granulite facies lithologies exhibit high values of initial susceptibility and saturation remanence, are laterally continuous, and may be considered as a deep crustal source for long-wavelength anomalies in low-geothermal gradient areas. Evidence is presented which suggests that such mafic-ultramafic bodies as those exposed in the Toce valley were synmetamorphic additions to the base of the crust.

Wasilewski, P.↗