Search NASA⌕ Search

SEARCH · Search NASA

Results for “MASS FILTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Effects of Molecular Size on Resolution in Charge Detection Mass Spectrometry

Instrumental resolution of Fourier transform-charge detection mass spectrometry instruments with electrostatic ion trap detection of individual ions depends on the precision with which ion energy is determined. Energy can be selected using ion optic filters or from harmonic amplitude ratios (HARs) that provide Fellgett’s advantage and eliminate the necessity of ion transmission loss to improve resolution. Unlike the ion energy-filtering method, the resolution of the HAR method increases with charge (improved S/N) and thus with mass. An analysis of the HAR method with current instrumentation indicates that higher resolution can be obtained with the HAR method than the best resolution demonstrated for instruments with energy-selective optics for ions in the low MDa range and above. However, this gain is typically unrealized because the resolution obtainable with molecular systems in this mass range is limited by sample heterogeneity. Here, this phenomenon is illustrated with both tobacco mosaic virus (0.6–2.7 MDa) and AAV9 (3.7–4.7 MDa) samples where mass spectral resolution is limited by the sample, including salt adducts, and not by instrument resolution. Nevertheless, the ratio of full to empty AAV9 capsids and the included genome mass can be accurately obtained in a few minutes from 1× PBS buffer solution and an elution buffer containing 300+ mM nonvolatile content despite extensive adduction and lower resolution. Empty and full capsids adduct similarly indicating that salts encrust the complexes during late stages of droplet evaporation and that mass shifts can be calibrated in order to obtain accurate analyte masses even from highly salty solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Online characterization of primary and secondary emissions of particulate matter and acidic molecules from a modern fleet of city buses

The potential impact of transitioning from conventional fossil fuel to a non-fossil-fuel vehicle fleet was investigated by measuring primary emissions via extractive sampling of bus plumes and assessing secondary mass formation using the Gothenburg Potential Aerosol Mass (Go:PAM) reactor from 76 in-use transit buses. Online chemical characterization of gaseous and particulate emissions from these buses was conducted using chemical ionization mass spectrometry (CIMS) with acetate as the reagent ion, coupled with the Filter Inlet for Gases and AEROsols (FIGAERO). Acetate reagent ion chemistry selectively ionizes acidic compounds, including organic and inorganic acids, as well as nitrated and sulfated organics. A significant reduction (48 %–98 %) in fresh particle emissions was observed in buses utilizing compressed natural gas (CNG), biodiesels like rapeseed methyl ester (RME) and hydrotreated vegetable oil (HVO), and hybrid-electric HVO (HVO HEV ) compared to diesel (DSL). However, secondary particle formation from photooxidation of emissions was substantial across all the fuel types. The median ratio of particle mass emission factors of aged to fresh emissions increased in the following order: DSL buses at 4.0, HVO buses at 6.7, HVO HEV buses at 10.5, RME buses at 10.8, and CNG buses at 84. Of the compounds that can be identified by CIMS, fresh gaseous emissions from all Euro V/EEV (Enhanced Environmentally friendly Vehicle) buses, regardless of fuel type, were dominated by nitrogen-containing compounds such as nitrous acid (HONO), nitric acid (HNO 3 ), and isocyanic acid (HNCO), alongside small monoacids (C 1 –C 3 ). Notably, the emission of nitrogen-containing compounds was lower in Euro VI buses equipped with more advanced emission control technologies. Secondary gaseous organic acids correlated strongly with gaseous HNO 3 signals (R 2 =0.85–0.99) in Go:PAM, but their moderate to weak correlations with post-photooxidation secondary particle mass suggest that they are not reliable tracers of secondary organic aerosol formation from bus exhaust. Our study highlights that non-regulated compounds and secondary pollutant formation, not currently addressed in legislation, are crucial considerations in the evaluation of environmental impacts of future fuel and engine technology shifts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A novel methodology for assessing the hygroscopicity of aerosol filter samples

Abstract. Due to US regulations, concentrations of hygroscopic inorganic sulfate and nitrate have declined in recent years, leading to an increased importance of the hygroscopic nature of organic matter (OM). The hygroscopicity of OM is poorly characterized because only a fraction of the multitude of organic compounds in the atmosphere is readily measured, and there is limited information on their hygroscopic behaviors. Hygroscopicity of aerosol is traditionally measured using a humidified tandem differential mobility analyzer (HTDMA) or electrodynamic balance (EDB). EDB measures water uptake by a single particle. For ambient and chamber studies, HTDMA measurements provide water uptake and particle size information but not chemical composition. To fill this information gap, we developed a novel methodology to assess the water uptake by particles collected on Teflon filters. This method uses the same filter sample for both hygroscopicity measurements and chemical characterization, thereby providing an opportunity to link the measured hygroscopicity with ambient particle composition. To test the method, hygroscopic measurements were conducted in the laboratory for ammonium sulfate, sodium chloride, glucose, and malonic acid, which were collected on 25 mm Teflon filters using an aerosol generator and sampler. Constant-humidity solutions (CHSs), including potassium chloride, barium chloride dihydrate, and potassium sulfate, were employed in a saturated form to maintain the relative humidity (RH) at approximately 84 %, 90 %, and 97 % in small chambers. Our preliminary experiments revealed that, without the pouch, water uptake measurements were not feasible due to rapid water loss during weighing. Additionally, we observed some absorption by the aluminum pouch itself. To account for this, concurrent measurements were conducted for both the loaded and the blank filters at each RH level. Thus, the dry loaded and blank Teflon filters were placed in aluminum pouches with one side open and in RH-controlled chambers for more than 24 h. The wet loaded samples and wet blanks were then weighed using an ultramicrobalance to determine the water uptake by the respective compound and the blank Teflon filter. The net amount of water absorbed by each compound was calculated by subtracting the water uptake of the blank filter from that of the wet loaded filter. Hygroscopic parameters, including the water-to-solute (W / S) ratio, molality, mass fraction solute (mfs), and growth factors (GFs), were calculated from the measurements. The results obtained are consistent with those reported by the Extended Aerosol Inorganics Model (E-AIM) and previous studies utilizing HTDMA and EDB for these compounds, highlighting the accuracy of this new methodology. This new approach enables the hygroscopicity and chemical composition of individual filter samples to be assessed so that in complex mixtures, such as chamber and ambient samples, the total water uptake can be parsed between the inorganic and organic components of the aerosol.

54 ENVIRONMENTAL SCIENCES↗

Performance Evaluation of AG-1 FC HEPA Filters and Medium in Nuclear Complex Facilities - 20434

High Efficiency Particulate Air (HEPA) filters are credited as the final barrier against the release of radioactive aerosol contamination in nearly every operating U. S. Department of Energy (DOE) and National Nuclear Security Agency (NNSA) nuclear facility. The Institute for Clean Energy Technology (ICET) at Mississippi State University maintains a research program that studies various aspects of these components of containment systems and seeks to answer key questions from across the industry. This programmatic overview will include results from recent and ongoing studies, including a study on filter design and performance envelope, degradation due to aging or fatigue, fire event impact on HEPA filters, and accelerated aging of medium and component parts. ICET has completed a study helping to define the threshold for combined elevated temperature and relative humidity resistance of separator style and separator-less style HEPA filters that are used in DOE complexes. The study provides experimental data that considers elevated temperature, elevated relative humidity (RH), and target differential pressure (dP) in an attempt to gain a better understanding or more comprehensive insight into the operating envelope of different configurations of ASME (American Society for Mechanical Engineers) AG-1 Section FC filters. Test variables including air temperature ranges of 48.88 deg. C, 54.44 deg. C, or 60 deg. C (120, 130, or 140 deg. F); air RH ranges including 60-70%, 80%, or 90+% with initial filter dP of either 497.68 Pa, 746.52 Pa, or 995.36 Pa (2 inches water column (in. w. c.), 3 in. w. c., or 4 in. w. c.) included for full bracketing of each set of conditions. A study examining the effects of aging and fatigue on nuclear grade HEPA filters and medium elucidates the physical properties of media along with testing of new and aged ASME AG-1 HEPA filters. In addition to performing autopsies of the tested, aged filters to help better understand the service life of their performance, newly designed accelerated aging chambers allow new medium to undergo accelerated aging and exposure treatments. Evaluation of degradation in physical properties and functionality requires a high population of aged filters of different ages, designs, manufacturers, and operational histories. The limited availability of this population and the impropriety of looking solely at formulations and components from past years requires experimental design that will provide foresight into future filter performance. This undertaking therefore involves not only properties analysis of aged medium from different operational histories, ages, designs, and manufacturers, but also prescience in analytical goals via accelerated aging studies of newly manufactured media. A more complete understanding of the mechanisms of degradation from past formulations as well as current and future formulations is possible. Accelerated Aging of newly manufactured media utilizes exposure treatments based on the Arrhenius equation to artificially age medium and therefore glimpse into the future. Evaluation of current media properties This testing allows for the comparison of performance and durability of new filters under upset or design basis conditions with aged filters that were in service under ambient conditions and other aged filters retained in storage. Susceptibility of HEPA filters to the effects of combustion byproducts, heat, and water is also being studied in an attempt to gain understanding on the prevention of filter failures during fire events in nuclear facilities. ICET seeks to determine the effect of filter performance due to smoke loading using characterized smoke from variable fuel compositions, geometries, and loads; the smoke capacity of various filters with different burning conditions, heat release rates and transport, as well as mass transport from the air stream will be studied in low flow containment systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Broadband and filter radiometers at Ross Island, Antarctica: detection of cloud ice phase versus liquid water influences on shortwave and longwave radiation

Abstract. Surface radiometer data from Ross Island, Antarctica, collected during the austral summer 2015–2016 by the US Department of Energy Atmospheric Radiation Measurement (ARM) program West Antarctic Radiation Experiment (AWARE), are used to evaluate how shortwave and longwave irradiance respond to changing cloud properties as governed by contrasting meteorological regimes. Shortwave atmospheric transmittance is derived from pyranometer measurements, and cloud conservative-scattering optical depth is derived from filter radiometer measurements at 870 nm. With onshore flow associated with marine air masses, clouds contain mostly liquid water. With southerly flow over the Transantarctic Mountains, orographic forcing induces substantial cloud ice water content. These ice and mixed-phase clouds attenuate more surface shortwave irradiance than the maritime-influenced clouds and also emit less longwave irradiance due to colder cloud base temperature. These detected irradiance changes are in a range that can mean onset or inhibition of surface melt over ice shelves. This study demonstrates how basic and relatively low-cost broadband and filter radiometers can be used to detect subtle climatological influences of contrasting cloud microphysical properties at very remote locations.

54 ENVIRONMENTAL SCIENCES↗

Ultrasensitive single-cell proteomics workflow identifies >1000 protein groups per mammalian cell

Here, we report on the combination of nanodroplet sample preparation, ultra-low-flow nanoLC, high-field asymmetric ion mobility spectrometry (FAIMS), and the latest-generation Orbitrap Eclipse Tribrid mass spectrometer for greatly improved single-cell proteome profiling. FAIMS effectively filtered out singly charged ions for more effective MS analysis of multiply charged peptides, resulting in an average of 1056 protein groups identified from single HeLa cells without MS1-level feature matching. This is 2.3 times more identifications than without FAIMS and a far greater level of proteome coverage for single mammalian cells than has been previously reported for a label-free study. Differential analysis of single microdissected motor neurons and interneurons from human spinal tissue indicated a similar level of proteome coverage, and the two subpopulations of cells were readily differentiated based on single-cell label-free quantification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transient Weighted Moving-Average Model of Photovoltaic Module Back-Surface Temperature

Accurate modeling of photovoltaic (PV) performance requires the precise calculation of module temperature. Currently, most temperature models rely on steady-state assumptions that do not account for the transient climatic conditions and thermal mass of the module. On the other hand, complex physics-based transient models are computationally expensive and difficult to parameterize. In order to address this, a new approach to transient thermal modeling was developed, in which the steady-state predictions from previous timesteps are weighted and averaged to accurately predict the module temperature at finer time scales. This model is informed by 3-D finite-element analyses, which are used to calculate the effect of wind speed and module unit mass on module temperature. The model, in application, serves as an added filter over existing steady-state models that smooths out erroneous values that are a result of intermittency in solar resource. Validation of this moving-average model has shown that it can improve the overall PV energy performance model accuracy by as much as 0.58% over steady-state models based on mean absolute error improvements and can significantly reduce the variability between the model predictions and measured temperature times series data.

14 SOLAR ENERGY↗

ODIN: Confirmation and 3D Reconstruction of Six Massive Protoclusters at Cosmic Noon

Protoclusters represent sites of accelerated galaxy formation and extreme astrophysical activity characteristic of dense environments. Identifying massive protoclusters and mapping their spatial structures are therefore crucial for understanding how large-scale environment influences galaxy evolution. We combine wide-field Lyα imaging from the One-hundred-deg$^{2}$ DECam Imaging in Narrowbands survey with extensive Dark Energy Spectroscopic Instrument and ancillary spectroscopy across the extended COSMOS and XMM Large Scale Structure (LSS) fields (≈14 deg$^{2}$) to search for massive protoclusters. We confirm six systems at z ≈ 2.4 and ≈ 3.1, including three newly identified structures and three which overlap with previously known structures and/or systems detected using other tracers. We reconstruct their three-dimensional structures, estimate descendant halo masses, and for one structure at z ≈ 3.12, demonstrate that overlapping narrowband filters (NB497 and N501) provide accurate redshift tomography for emission-line galaxies. One protocluster at z ≈ 2.45 overlaps with one of the LATIS tomographic fields, enabling direct comparison between galaxy and H i overdensities traced by Lyα forest absorption. Another at z ≈ 3.12 hosts a massive quiescent galaxy (M$_{*}$ ≈ 1.2 × 10$^{11}$M$_{⊙}$), suggesting that overdense environments may play a role in accelerating galaxy assembly and quenching. Comparing Lyα emission properties across environments, we find that protocluster galaxies exhibit higher median line fluxes and a deficit of faint emitters relative to the field. The effect is strongest when combining 2D and 3D density information, indicating that galaxies in the densest protocluster cores are most affected by environmental processes. This effect is stronger at z ≈ 3.1 than at z ≈ 2.4, suggesting possible redshift evolution.

Ortiz, Ashley [Purdue U.] (ORCID:000900083184304X)↗

Quantitative Measurement of Positive and Negative Ion Species Ejected from a Li–O–H Surface by Hydrogen and Noble Gas Ion Irradiation

We report sputtering yields of Li + , H - , O - , and OH x - ion species from an Li–O–H surface for H, D, He, Ne, and Ar ion irradiation at 45° incidence in the energy range of 30–2000 eV. A Li film was deposited on a stainless steel target using Li evaporators in the LTX-β vessel, using the LTX-β Sample Exposure Probe (SEP), which includes an ultrahigh vacuum suitcase for transferring targets without significant contamination from air exposure. The SEP was used to transfer the Li-coated target from LTX-β to a separate Sample Exposure Station (SES) to perform ion exposure measurements. The SEP was also used for characterization of the Li-coated target utilizing X-ray photoelectron spectroscopy in a different chamber, showing that the lithium film surface was oxidized. Ion exposures were performed using an electron cyclotron resonance plasma source in the SES. Sputtered/ejected species were sampled by a quadrupole mass spectrometer with capabilities for detecting positive and negative ions, and an energy filter for determining the mean kinetic energy of the ejected ion species. All ion irradiations caused Li + ions to be ejected, while causing impurity ions such as H + , H - , O - and OH - to be ejected. Measured ion energies of Li + ions from a Li–O–H surface suggested that the typical sheath potential on the divertor surface can trap sputtered Li + ions, which were previously reported as ~ 60% of total sputtered Li species from Li targets (Allain and Ruzic in Nucl Fusion 42:202, 2002). Hence, our results for the sputtering yields of ejected ion species and their associated ion energies from a Li–O–H surface indicates that lithium sputtering is suppressed and impurity removal is enhanced due to the sheath potential at the divertor surface for fusion reactor applications.

Plasma-material interaction↗

TopPICR: A Companion R Package for Top-Down Proteomics Data Analysis

Top-down proteomics is the analysis of proteins in their intact form without proteolysis, thus preserving valuable information about post-translational modifications, isoforms, and proteolytic processing. However, it is still a developing field due to limitations in the instrumentation, difficulties with interpretation of complex mass spectra, and a lack of well-established quantification approaches. TopPIC is one of the popular tools for proteoform identification. Here we extended its capabilities into label-free proteoform quantification by developing a companion R package (TopPICR). Key steps in the TopPICR pipeline include filtering identifications, inferring a minimal set of protein accessions explaining the observed sequences, aligning retention times, recalibrating measured masses, clustering features across datasets, and finally compiling feature intensities using the match-between-runs approach. The output of the pipeline is an MSnSet object which makes downstream data analysis seamlessly compatible with packages from the Bioconductor project. It also provides the capability for visualizing proteoforms within the context of the parent protein sequence. The functionality of TopPICR is demonstrated on top-down LC-MS/MS datasets of 10 human-in-mouse xenografts of luminal and basal breast tumor samples.

59 BASIC BIOLOGICAL SCIENCES↗

Accurate Identification of Deamidation and Citrullination from Global Shotgun Proteomics Data Using a Dual-Search Delta Score Strategy

While proteins with deamidated/citrullinated amino acids play critical roles in the pathogenesis of many human diseases, identifying these modifications in complex biological samples has been an ongoing challenge. Herein we present a method to accurately identify these modifications from shotgun proteomics data from a deep proteome profiling study of human pancreatic islets obtained by laser capture microdissection. All MS/MS spectra were searched against database by MSGF+ twice with or without a +0.9840 Da mass shift on amino acids asparagine, glutamine, and arginine (NQR) as a dynamic modification. Consequently, for each spectrum the resulting two peptide-to-spectrum matches (PSM) with their respective MSGF+ scores were used for Delta Score calculation. It was observed that all PSMs with positive Delta Score values were clustered with mass errors around 0 ppm, while PSMs with negative Delta Score values were distributed nearly equally within the defined mass error range (20 ppm) for database searching. To estimate false discovery rate (FDR), a “pseudo-decoy” approach was applied whether datasets were searched against a database with a “real modification” mass shift (+0.9840 Da) and a “mock modification” mass shift (+1.0227 Da). FDR was controlled to ~2% with a Delta Score filter greater than zero. Manual inspection of spectra showed that PSMs with positive Delta Score value contained deamidated/citrullinated fragments in their MS/MS spectra. Finally, the results demonstrated that in-situ deamidated/citrullinated peptides can be accurately identified from shotgun tissue proteomics data by the Dual-search Delta Score Strategy.

59 BASIC BIOLOGICAL SCIENCES↗

Isolation of genome-predicted Caldatribacterium ( Atribacterota ) reveals pervasive microbial cultivation problem due to folate precipitation

Most bacterial phyla have few or no pure cultures, including Atribacterota , comprised of ubiquitous anaerobes. Here, we report genome-guided enrichment and isolation of two Atribacterota species representing a new family, Caldatribacterium saccharofermentans from a hot spring, and Caldatribacterium inferamans from a deep aquifer. Both were co-enriched with sulfate-reducing bacteria and initially resisted isolation, which we link to inadvertent removal of precipitated folic acid by filter-sterilization of unbuffered Wolin’s vitamin solution. We then predict folate auxotrophy across the Atribacterota and ~29% of all bacteria, with extensive auxotrophy in 27% of phyla. Since ≥604 of 791 ( ≥ 76%) media with folic acid additions in the MediaDive database use unbuffered vitamin solutions in which folic acid is likely removed during filter-sterilization, we propose that folate auxotrophy limits culturability in defined media en masse. We also uncover unusual features of Caldatribacterium , including three lipid membrane-like layers (LMLs), with the inner LML surrounding the nucleoid, and a high percentage of secreted proteins, supporting a unique cell biology of Atribacterota .

Biological and medical sciences↗

Constraints on the normal branch of DGP gravity from SPT galaxy clusters with DES and HST weak-lensing mass calibration and from P l a n c k PR4 CMB anisotropies

We present constraints on the normal branch of the Dvali-Gabadadze-Porrati (nDGP) braneworld gravity model from the abundance of massive galaxy clusters. On scales below the nDGP crossover scale r c , the nDGP model features an effective gravitylike fifth force that alters the growth of structure, leading to an enhancement of the halo mass function (HMF) on cluster scales. The enhanced cluster abundance allows for constraints on the nDGP model using cluster samples. We employ the South Pole Telescope (SPT) cluster sample, selected through the thermal Sunyaev-Zel’dovich effect with the SPT and with mass calibration using weak-lensing data from the Dark Energy Survey (DES) and the Hubble Space Telescope (HST). The cluster sample contains 1,005 clusters with redshifts 0.25 < z < 1.78 , which are confirmed with the multicomponent matched filter algorithm using optical and near-infrared data. Weak-lensing data from DES and HST enable a robust mass measurement of the cluster sample. We use DES Year 3 data for 688 clusters with redshifts z < 0.95 , and HST data for 39 clusters with redshifts 0.6 < z < 1.7 . We account for the enhancement in the HMF through a semi-analytic correction factor to the standard cosmology HMF derived from the spherical collapse model in the nDGP model. We then further calibrate this model using N -body simulations. In addition, for the first time, we analyze the primary CMB temperature and polarization anisotropy measurements from Planck PR4 within the nDGP model. We obtain a competitive constraint from the joint analysis of the SPT cluster abundance with the Planck PR4 data, and report an upper bound of 1 / H 0 r c < 1.41 at 95% when assuming a cosmology with massive neutrinos.

Vogt, S. M.L. [Munich U. Observ.; LMU Munich (main↗

The Atacama Cosmology Telescope: DR6 Sunyaev-Zel'dovich Selected Galaxy Clusters Catalog

We present the results of a search for galaxy clusters in the Atacama Cosmology Telescope (ACT) Data Release 6 (DR6) microwave sky maps covering 16293 square degrees in three frequency bands, using data obtained over the lifetime of the project (2008-2022). We report redshifts and mass estimates for 10040 clusters detected via their Sunyaev-Zel'dovich (SZ) effect with signal-to-noise greater than 4 at a 2.4 arcminute filter scale. The catalog includes 1180 clusters at redshifts greater than 1, and 124 clusters at redshifts greater than 1.5. Using a relation between cluster SZ signal and mass that is consistent with recent weak-lensing measurements, we estimate that clusters detected with signal-to-noise greater than 5 form a sample which is 90% complete for clusters with masses greater than $5 \times 10^{14}$ MSun (measured within a spherical volume with mean density 500 times the critical density). El Gordo, a cluster found in an initial ACT survey of 755 square degrees, remains the most extreme cluster in mass and redshift; we find no cluster with a mass and redshift combination high enough to falsify the standard LCDM cosmology with Gaussian initial perturbations. We make public a variety of data products, including the full cluster candidate list, noise maps, and sky masks, along with our software for cluster detection and instructions for reproducing our cluster catalogs from the public ACT maps.

Aguena, M. [Trieste Observ.; LIneA, Rio de Janeiro↗

Dicarboxylic acid emissions from a GDI engine equipped with a catalytic gasoline particulate filter

Dicarboxylic acids play an important role in atmospheric chemistry, yet their emissions from primary sources, such as internal combustion engines, has not been extensively studied. In this paper, KOH impregnated quartz filters were loaded with exhaust gases from a gasoline direct injection (GDI) engine equipped with a catalytic gasoline particulate filter (GPF). All filters were analyzed for carboxylic and dicarboxylic acids using a derivatized gas chromatography-mass spectroscopy method. Exhaust gas was sampled from pre-GPF and post-GPF locations to determine the performance of the GPF regarding acid conversion. Lean and stoichiometric engine modes were considered with non-oxygenated gasoline and 10% splash blended ethanol in gasoline (E10) to examine the impact of stoichiometry and fuel type. Acid emissions represented as much as 0.51% of total unburned hydrocarbon emissions for total monocarboxylic acids and as much as 0.40% for total dicarboxylic acids. Individual acid concentrations were as high as 38 mg/kg-fuel for monocarboxylic acids and as high as 29 mg/kg-fuel for dicarboxylic acids. Overall, the study found that fuel oxygenates had mixed impact on the acid emissions. Engine-out monocarboxylic acids were reduced when using the E10 fuel by approximately 30–45% for the stoichiometric condition and increased marginally for the lean condition. Dicarboxylic acid emissions were generally insensitive to ethanol content. However, the engine condition significantly affected the acid emissions. Lean operation produced a factor of two to an order of magnitude higher emissions rates of both monocarboxylic and dicarboxylic acids than the stoichiometric condition. The catalytic GPF eliminated between 80 and 92% of the acids emitted from the engine, allowing some acids to be emitted into the environment.

42 ENGINEERING↗

The Feasibility of Directly Imaging Nearby Cold Jovian Planets with MIRI/JWST

The upcoming launch of the James Webb Space Telescope (JWST) will dramatically increase our understanding of exoplanets, particularly through direct imaging. Microlensing and radial velocity surveys indicate that some M dwarfs host long-period giant planets. Some of these planets will likely be just a few parsecs away and a few astronomical units from their host stars, a parameter space that cannot be probed by existing high-contrast imagers. We studied whether the coronagraphs on the Mid-infrared Instrument on JWST can detect Jovian-type planets around nearby M dwarfs. For a sample of 27 very nearby M dwarfs, we simulated a sample of Saturn–Jupiter-mass planets with three atmospheric configurations and three orbital separations, observed in three different filters. We found that the f1550c 15.5 μm filter is best suited for detecting Jupiter-like planets. Jupiter-like planets with patchy cloud cover, 2 au from their star, are detectable at 15.5 μm around 14 stars in our sample, while Jupiters with clearer atmospheres are detectable around all stars in the sample. Saturns were most detectable at 10.65 and 11.4 μm (f1065c and f1140c filters), but only with cloud-free atmospheres and within 3 pc (six stars). Surveying all 27 stars would take <170 hr of JWST integration time, or just a few hours for a shorter survey of the most favorable targets. There is one potentially detectable known planet in our sample: GJ 832 b. Observations aimed at detecting this planet should occur in 2024–2026, when the planet is maximally separated from the star.

79 ASTRONOMY AND ASTROPHYSICS↗

Flow Induced Vibration Studies in Pressurized Helium Gas Cooling Channels

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process. During irradiation, pressurized helium gas flows through 0.25 mm thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo-100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Longer duration testing will provide more data and verification for the findings presented in this report. The work will be continued in FY 24.

43 PARTICLE ACCELERATORS↗

Window Cooling Studies and Disk Vibration Testing on a Subset of Mo-100 Disks

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless-steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process, with a smaller percentage adding up to 2.2 kW of heat deposited on the Inconel window. During irradiation, pressurized helium gas flows through thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo 100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. LANL has previously also tested NMR’s Inconel beam window by heating the window, while flowing pressurized helium, using the average heat deposited on the window. However, the NMR beam is pulsed with a duty cycle of 12.5%, which introduces oscillation in temperature around the nominal 600 °C steady state value with each pulse. Available fatigue curves for Inconel are few, established for room temperature, and they are based on mechanical strain cycles not thermally induced strain as in the NMR target. The effect of pulsed beam heating on the Inconel window therefore needs to be quantified. This report details the experiments conducted to assess the factors that lead to mass loss in the NMR target disks as well as to understand the effect of a pulsed beam on NMR’s Inconel window. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 5 to 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Improved target holders significantly reduce disk mass loss to almost negligible quantities. This work finds that the larger window to first disk gap and improved target holder geometry should allow NMR to successfully conduct irradiations with minimal mass loss. The window tests were conducted to understand the effect of a pulsed beam on both the window longevity and to estimate the window temperature and displacement during pulsing. The experiments presented here were performed at significantly low power, due to the limitations of the induction heating system. The window temperature rose to approximately 73 °C with a significantly reduced power of 45 W without beam pulsing. With a 5 Hz pulse rate, 12.5% duty cycle, the window temperature remained constant at 26 °C. These experiments will be repeated with improved coil geometry and reported in upcoming journal papers.

42 ENGINEERING↗