Search NASA⌕ Search

SEARCH · Search NASA

Results for “MCNP Model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Godiva IV Simulated Radiation Field Characterization and Variance Reduction

Godiva IV is a system comprised of highly enriched uranium alloyed with molybdenum in the form of fuel plate rings. The reactor, along with its predecessors, was designed with the unique ability to satisfy interests in the super-prompt-critical reactor operation space. Originally, the reactor was part of the Los Alamos Critical Experiments Facility (LACEF) at Technical Area-18 (TA-18). The radiation field around Godiva at this facility was well characterized and understood. As a fast neutron system, the neutron spectrum in and around Godiva was close to a Watt Fission spectrum. The Kiva where Godiva IV was located at LACEF was made of thin, sheet metal walls which did not contribute significantly to the neutron spectrum. Following the transition of LACEF to the National Critical Experiments and Research Center (NCERC) in Nevada, Godiva-IV was moved from TA-18 to the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS). Part of this move brought renewed interest in radiation field characterization. The new facility introduced significant changes to the environment surrounding Godiva, and preliminary foil irradiation results suggested that the room contribution to the neutron spectrum was significant. Unlike at TA-18, a large thermal neutron signature was added to the fast spectrum from Godiva due to significant room return. A primary goal due to the additional complexity that the room return adds to the Godiva IV radiation emission spectrum was the development of an efficient Monte Carlo N-Particle (MCNP) calculation capable of characterizing the neutron spectrum anywhere in the room around Godiva. A campaign of activation foil irradiations and analysis were completed to support the validation of the MCNP model. The modeling of these foils in MCNP can be easily done with a standard volumetric neutron flux tally. However, given the multitude of locations and reaction rates to be modeled, further steps must be taken to increase the efficiency of these calculations in MCNP. During this study, a benchmark model currently under development for Godiva IV was used. A qualitative assessment of the thermal neutron contributors was performed using spatial neutron distribution plots. Additional detail was added to the model based on the qualitative results showing the thermal spectrum’s large sensitivity to hydrogenous material. Neutron energy spectra was evaluated at discrete locations in the room around Godiva to quantify the relative contribution of various components. It was discovered that the concrete walls are the largest contributor to the thermal signature, with minor contributions from plastic components surrounding Godiva. Following these results, two different variance reduction techniques were implemented to improve the problem efficiency in these calculations. In the first approach, an F5 point detector tally was implemented in the standard Godiva IV criticality problem. The second approach involved a weight-window generator implementation with an F5 point detector tally in a fixed source problem. The weight window implementation reduced the runtime from 42739.55 minutes to 1803.34 minutes (computer time), compared to the F5 KCODE implementation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Predicting deviations in ex-core detector response in Krsko NPP during an earthquake with Monte-Carlo neutron transport methods

To study the response of ex-core detectors during an earthquake, an approach using Monte Carlo code MCNP was developed. As a first step to predict the response of the ex-core detectors a detailed MCNP model of the Krsko reactor core was created. A detailed MCNP core model was used to calculate 3D power distributions inside the core. Calculated power distributions were verified by comparison to the CORD-2 calculations, which is currently used for core design calculation verification of the Krsko nuclear power plant. Due to the outside the core position of the neutron detectors, the hybrid code ADVANTG is used to generate weight windows to speed up neutron transport outside the reactor core. To be able to use ADVANTG, fixed neutron source had to be reconstructed from the criticality core calculation. It was found that the power range ex-core detector movement has a negligible effect on the value of the thermal neutron flux at the active part of the detector. However, the 5 cm radial movement of the intermediate-range detector leads to 7 % - 8 % change in thermal neutron flux within the active intermediate-range detector region. The analysis continued with the evaluation of the effect of core barrel movement on the ex-core detector response. It was determined that the 2 mm core barrel radial oscillation can lead to ∼ 4% change in thermal neutron flux within the active detector region. It was evaluated that reactor core movement inside the baffle can lead up to ∼ 1.9% and ∼ 1.3% deviation in power-range and intermediate-range detector signal respectively. Analysis showed that the mechanical movement of ex-core neutron detectors could not explain the fluctuations in the ex-core detector signal. However, combined core barrel and reactor core inside baffle oscillations could be a probable reason for the observed fluctuations in the ex-core detector signal during an earthquake. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Validation of MCNP Critical Benchmarks Models of Highly Enriched Uranium Cylinders

A new centralized repository of high-quality MCNP models of critical benchmark experiments is currently under development at Los Alamos National Laboratory (LANL). The benchmark experiments are described in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook, and the initial set of benchmark models are derived from the Whisper Suite provided with MCNP6.2. This effort is a collaboration among the Nuclear Criticality Safety, Nuclear Data, and Monte Carlo code development/application organization at LANL. The objective is to create a current single LANL benchmark collection that includes the latest ICSBEP revision that has a formal review and revision process, is contained in an open- source repository, and utilizes new Python tools for improved input and output file review.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MCNP5 Calculations Replicating ARH-600 Nitrate Data

This report serves to extend the previous document: "MCNP Calculations Replicating ARH-600 Data" by replicating the nitrate curves found in ARH-600. This report includes the MCNP models used, the calculated critical dimension for each analyzed parameter set, and the resulting data libraries for use with the CritView code. As with the ARH-600 data, this report is not meant to replace the analysis of the fissile systems by qualified criticality personnel. The MCNP data is presented without accounting for the statistical uncertainty (although this is typically less than 0.001) or bias and, as such, the application of a reasonable safety margin is required. The data that follows pertains to the uranyl nitrate and plutonium nitrate spheres, infinite cylinders, and infinite slabs of varying isotopic composition, reflector thickness, and molarity. Each of the cases was modeled in MCNP (version 5.1.40), using the ENDF/B-VI cross section set. Given a molarity, isotopic composition, and reflector thickness, the fissile concentration and diameter (or thicknesses in the case of the slab geometries) were varied. The diameter for which k-effective equals 1.00 for a given concentration could then be calculated and graphed. These graphs are included in this report. The pages that follow describe the regions modeled, formulas for calculating the various parameters, a list of cross-sections used in the calculations, a description of the automation routine and data, and finally the data output. The data of most interest are the critical dimensions of the various systems analyzed. This is presented graphically, and in table format, in Appendix B. Appendix C provides a text listing of the same data in a format that is compatible with the CritView code. Appendices D and E provide listing of example Template files and MCNP input files (these are discussed further in Section 4). Appendix F is a complete listing of all of the output data (i.e., all of the analyzed dimensions and the resulting k eff values).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verification of MCNP Critical Benchmark Model of U233-COMP-THERM-004

Los Alamos National Laboratory (LANL) has been working on creating a new centralized repository for MCNP models of critical benchmark experiments. The initial model of U233-COMP-THERM-004 was derived from the Whisper Suite provided with MCNP6.2, and was compared against the ICSBEP handbook chapter for the benchmark. Many notable errors were found in the initial model and were revised accordingly. Comparing the computational model of the old and new models confirmed that any Whisper results that relied upon the old model are still valid.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of Modeled to Measured Spectra using MCNP and GADRAS to Benchmark and Contrast Modeling Limitations

The desire to improve nuclear material detection through portal monitors and other low resolution detectors has led to interest in benchmarking the performance of radiation transport codes. These codes can be used to generate a variety and quantity of spectra that may be cost prohibitive to measure directly. Particular characteristics of typical detection scenarios were isolated to compare the performance of radiation transport codes to laboratory experiments. These benchmark experiments were performed to validate simulations in a number of key areas. These experiments included high areal density configurations in both one- and three-dimensional configurations. In addition, off-angle measurements were conducted to investigate the impact of detector response assumptions on complex geometries, for example where an unknown source is not physically collocated with an apparent hot spot. Furthermore, by examining both simple shielding and backscatter configurations, isolation of the scatter emanating from the object and environmental background scatter contributions to the spectra could be elucidated. A series of experiments were performed in which the order of shielding layers and the thickness were evaluated to examine the ability of the simulations to address these variables. Experiments with increasing thickness of polyethylene around a neutron source also allows for examinations of the ability of the transport simulations to properly model n,γ reactions. Finally, depleted uranium (DU) measurements have more complicated spectra than the cobalt-60 and consequently allow for investigations into the ability of transport simulations to model self-shielding. In each case, the results of the experiments were compared to MCNP simulations to judge the performance of the code, as was done previously with GADRAS 18.7.9 simulations [7]. All of the benchmark measurements were taken with a liquid nitrogen cooled 140% high purity germanium (HPGe) detector with a bismuth collimator that had the front tin filter removed. The measurement location and detector configuration were subsequently used for all experimental configurations. The remainder of this report details the experimental measurements, Section 2 and the MCNP model, Section 3. Comparisons between the experimental results and MCNP-generated spectra are performed, Section 4. Section 5 compares the results obtained with MCNP with the previously reported results obtained with GADRAS [2]. Finally, Section 6 presents the conclusions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Passive Neutron Instrumentation and Applications

This chapter presents a description of most of the instruments that are currently in use for the measurement of plutonium and uranium using passive methods (without an external source). This includes the acquisition electronics as well as Singles counting methods, coincidence counting methods and multiplicity counting methods. The Singles counting applications include the measurement of waste and curium bearing materials. The coincidence counting applications include bulk plutonium, bulk uranium, waste and holdup measurements and fresh fuel assemblies. The multiplicity application description includes advantages and disadvantages and multiplicity detector design. There is also a description of some non-3He systems. The chapter concludes with a description of additional concepts: neutron imagers, list-mode data analysis, distributed source term analysis, unattended monitoring and MCNP modeling for detector design.

Coincidence shift register↗

Validation of general purpose mathematical efficiency modeling with ISOCS - 15579

Gamma spectroscopy is a commonly used method for radioactive waste characterization and activity determination in in-situ objects. The gamma rays emitted by radionuclides in the waste container matrix are highly penetrating and can be measured using one or more gamma ray detectors, thus allowing for a passive nondestructive assay. One problem is that a source based calibration of full energy peak efficiency can be difficult or impractical because of the large size and/or an unusual shape of the sample geometry. One attractive solution is to use mathematical efficiency modeling to calculate the full energy peak efficiency. The In-Situ Object Calibration Software (ISOCS) has successfully been used for more than a decade for mathematical efficiency modeling of template based geometries. Templates include the most common objects in waste characterization and D and D, including but not limited to: boxes, drums, and pipes with hotspots, beams, tanks and walls. Scenarios exist where these templates cannot model the desired measurement geometry. Canberra has developed a general purpose version of ISOCS where primitive objects can be combined into practically any geometry. The primitive objects are right circular cylinder, right elliptical cylinder, right circular cone, right elliptical cone, sphere, spheroid, ellipsoid, box (rectangular parallelepiped), torus, and beaker (any cylindrical symmetric object). Multiple primitive objects can be combined using the priority scheme and cut by planes into almost any desired shape. In addition, multiple objects can be defined in the same scene, for example cylinders next to each other or a pipe and a box. Collimators can be constructed as easily as in template based ISOCS. The ray tracing algorithm in ISOCS has been extended to support the new primitive objects for attenuation calculation between the radioactive source and the detector end cap. The new version uses the same vacuum efficiency response, or characterization, in the energy range 10 - 7000 keV of individual detectors to be able to calculate the efficiency as accurately as possible. MCNP has been shown to be able to calculate detection efficiencies for any geometry and the new version of ISOCS have been validated to MCNP. The vacuum efficiency is based on an MCNP model and this model was the base for constructing an identical model in MCNP as in ISOCS. The calculated efficiencies from the two codes have been compared and the agreement is within 3% except for the lowest energies for one geometry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validation of MCNP Critical Benchmark Models of PU-MET-FAST-016 [Slides]

The validation of PU-MET-FAST-016 contributed to the centralized LANL benchmark repository currently under development. The revisions made the MCNP models statistically, significantly more similar to the benchmark models. The overall impact on the USL is negligible. The revisions to the PU-MET-FAST-016 models provide value to the Los Alamos Benchmark Suite without invalidating past Whisper results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verification of MCNP Critical Benchmark Model of U233-COMP-THERM-004 [Slides]

The verification of U233-COMP-THERM-004 contributed to the LANL centralized repository that’s currently under development. Revisions made to the MCNP model were statistically significant. Magnitude of bias is relatively small in comparison to other uranium benchmark biases and thus will likely have not a significant effect on the USL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quarterly Report for Dry Storage Safeguards -Q3-2018-LLNL

The objective of this study is to develop a novel methodology for verification of spent fuel inside dry storage casks by analyzing fast/epi-thermal neutrons coming from the top surface of the dry storage casks. In FY2018, data required for MCNP modeling will be gathered, prepared and used to perform MCNP simulations of the system to validate the effectiveness of the verification methodology. Once the methodology is demonstrated to be effective and valid, parameters that affect the detector system sensitivity will be studied as well as the study of diversion scenarios and partial detect.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MONTE CARLO ANALYSES OF THE YALINA THERMAL FACILITY WITH SERPENT STEREOLITHOGRAPHY GEOMETRY MODEL

This paper analyzes the YALINA Thermal subcritical assembly of Belarus using two different Monte Carlo transport programs, SERPENT and MCNP. The MCNP model is based on combinatorial geometry and universes hierarchy, while the SERPENT model is based on Stereolithography geometry. The latter consists of unstructured triangulated surfaces defined by the normal and vertices. This geometry format is used by 3D printers and it has been created by: the CUBIT software, MATLAB scripts, and C coding. All the Monte Carlo simulations have been performed using the ENDF/B-VII.0 nuclear data library. Both MCNP and SERPENT share the same geometry specifications, which describe the facility details without using any material homogenization. Three different configurations have been studied with different number of fuel rods. The three fuel configurations use 216, 245, or 280 fuel rods, respectively. The numerical simulations show that the agreement between SERPENT and MCNP results is within few tens of pcms.

CUBIT↗

Integration of the Full Tokamak Reference Model with the Complex Model for ITER Neutronic Analysis

The ITER International Organization has developed a number of reference Monte Carlo N-Particle (MCNP) models including the tokamak machine C-model, the Tokamak Complex model, and the neutral beam injection (NBI) systems model. The Tokamak Complex model primarily describes building structures beyond the bioshield. Representation of the tokamak and its systems are not included in this model. The Oak Ridge National Laboratory Radiation Transport Group has conducted two ITER neutronic analysis model integrations: (1) integration of the tokamak C-model with the Tokamak Complex model for shutdown dose rate characterization in Port Cell 16 at level B1, and (2) integration of the NBI model with the Tokamak Complex model for estimating the spatial distribution of biological dose rate at levels L1, L2, and L3 of the Tokamak Complex. The integrated models were further extended to include models of system components that are essential to the neutronic analyses. Furthermore, this paper presents the approach and computer tools used to integrate existing reference models, describes the additional design details implemented in the integrated models, and provides representative neutronic calculations based on the extended models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Whisper Results of a PuCl "Solution" System Using LLNL TEX Cl Benchmark Model

This data set is to be shared with the Nuclear Criticality Safety Division (NCSD) at LLNL as part of a TEX Cl experiment. NCSD at LLNL shared the experimental model with the Nuclear Criticality Safety (NCS) Division at LANL for comparison with an MCNP model of a PuCl application system. The experimental model was used in conjunction with Whisper to see how including it would impact the baseline USL for the PuCl application.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

JMOCUP Physics Depletion Calculations for the As-Run AGR-5/6/7 TRISO Particle Experiment in ATR Northeast Flux Trap

This ECAR documents the as-run Jim Sterbentz’s MCNP ORIGEN Coupled Utility Program (JMOCUP) physics depletion calculation and the calculated results for the AGR-5/6/7 irradiation experiment in the Advanced Test Reactor (ATR). AGR 5/6/7 was irradiated for nine power cycles in the northeast flux trap. The depletion calculations were performed to provide input data for a variety of other engineering analyses supporting the AGR-5/6/7 experiment along with post-irradiation characterization of the tri-structural isotropic (TRISO) particle fuel compacts. Detailed full-core MCNP models and Oak Ridge Isotope Generation (ORIGEN2) radionuclide generation models were specifically developed as part of the JMOCUP Monte Carlo depletion calculations. The MCNP ORIGEN2 computer codes were coupled using the well-established JMOCUP utility modules to couple the two codes and run the depletion calculations. The physics calculations were performed in support of the Advanced Gas Reactor (AGR) program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sensor Placement Optimization Study for the Built Environment: Operational Use Cases

Systems of fixed-position radiation sensors can provide information that assists emergency responders following nuclear and radiological incidents. State, local, tribal, and territorial (SLTT) government agencies that implement systems of fixed-position sensors are faced with numerous decisions regarding sensor selection, quantity, and placement. To develop guidance on implementation of radiation detection systems, we simulated the release of radioactive material in an urban environment using a combination of three models: the Weather Research Forecasting (WRF), Quick Urban and Industrial Complex (QUIC), and Monte Carlo N-Particle (MCNP) models. We then evaluated the performance of several hypothetical sensor systems. The small number of simulations we conducted are not sufficient to generate definitive design guidance for radiation sensor systems, but we did identify trends that would be of interest to emergency planners. For a scenario that releases 1000 curies of Cs-137, radiation detectors were needed at 500-meter intervals to have a high likelihood of event detection and to estimate source location and plume detection. We also noted that optimal detector altitude varied with distance to the source. We recommend additional research in this area be conducted to support developing sensor placement guidelines that expand on a range of locations, isotopes, activity levels, and different weather conditions. Original simulation strategies included a range of environments, additional radioisotopes (Am241 and AmBe), and a larger selection of sensor types. These types of expansions would support SLTT guidance on sensor system recommendations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparing Control Performance Between Simulation and Experiment using the Microreactor Automated Control System Testbed

In the advanced reactor domain, a flexible and scalable software/hardware infrastructure is crucial for integrating and validating various control technologies. This study used the Microreactor Automated Control System (MACS) hardware platform as a testbed. MACS was originally designed to mirror Idaho National Laboratory (INL)'s Microreactor Applications Research Validation and Evaluation (MARVEL), a 85-kW thermal fission microreactor. It features control drums for simulated reactivity control; lights that function as a surrogate reactor core, with the brightness being proportional to the reactor power; and light sensors that emulate neutron detectors. To transform MACS into a physical twin of MARVEL for evaluating control methods, the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND) software was employed. This software integrated the hardware with two models of the MARVEL core, based on Reactor Excursion and Leak Analysis Program (RELAP5-3D) and Monte Carlo N-Particle (MCNP) models. The study aimed to demonstrate the gap between control theory and actual practice—a gap that often necessitates empirical adjustments such as control gain retuning, filters, time discretization, and integrator anti-windup measures. Controllers were developed based on increasingly complex simulations without hardware, starting from the base MARVEL model and then introducing actuator saturation constraints and sensor noise. The final control strategy was then tested using MACS, and a comparative performance analysis was conducted.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Numerical Simulation of Irradiation Induced Swelling for STAR 4.1 Blanket

Here, this article presents the preliminary results of FEM implementation of irradiation-induced swelling, hardening, and creep effect using ANSYS user programmable features (UPFs) applied to material properties. The first liquid metal breeding blanket model for STAR 4.1 tokamak as a part of the virtual prototyping system is under development at Princeton Plasma Physics Laboratory (PPPL). Intense neutron irradiation produces significant changes in the physical and mechanical properties of Fe-(8%–9%)Cr-based reduced activation ferritic martensitic (RAFM) steels. An ANSYS model of the breeding blanket was built to involve these irradiation-induced material property changes with neutron fluence distribution mapped from the MCNP model. Simulation results show that significant structure deformation forms from nuclear swelling, stress, and plastic strain arising from DPA gradient through wall thickness. The material degradation effect is not negligible. This modeling feature can either assist in analyzing the structural behaviors with the influence of nuclear swelling or provide guidance to design the structure to withstand irradiation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗