Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEDICATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Overview of Exploration Medical Capability Systems Engineering Level 4 Requirements for Medical Level-of-Care IV in Space Lunar Orbit Habitat

This paper presents how the Exploration Medical Capability Element of the National Aeronautics and Space Administration’sHuman Research Program usingModel-Based System Engineering is defining Level 4 Foundational Requirements to provide Medical Level-of-Care IV in a space Habitat during exploration missions.

Space Habitat Medical System Engineering Requireme↗

Development of polymer 'chips' used in medical diagnostics

In recent years, there has been growing interest in creating bio-inspired devices that feature artificial bilayer lipid membranes (BLM), or lipid bilayers. These membranes can be tailored to mimic the structure and transport properties of cellular walls and can be used to selectively transport ions and other species between aqueous volumes. One application of this research is the formation of a standardized BLM contained within a portable and disposable housing for use in medical diagnostics. This concept utilizes a flexible polymer 'chip' that has internal compartments for housing both an organic solvent and an aqueous solution, which contains phospholipid molecules, proteins, and specific analyte molecules. The formation of a BLM within the chip enables integration of the chip into an electronic reader to perform diagnostic measurements of the sample. A key element of the bilayer formation process requires a single aqueous volume to first be separated into multiple volumes such that it can then be reattached to form a bilayer at the interface. This process, called the regulated attachment method, relies on the geometry of the deformable 'chip' to separate and reattach the aqueous contents held inside by opening and closing an aperture that divides adjacent compartments through the application of mechanical force. The purpose of this research is to develop an optimized chip that provides a controllable method for initially separating the aqueous phase via dynamic excitation. This study focuses on two specific aspects: designing an efficient excitation method for separating the aqueous volume, and optimizing the geometry of the chip to decrease the required input energy and better target the location and duration of the separation. Finite Element (FE) models are used to optimize the chip geometry and to identify suitable excitation signals. A series of experimental studies are also presented to validate the FE models.

42 ENGINEERING↗

International Medical Graduates in Radiation Oncology: Historical Trends and Comparison With Other Medical Specialties

Purpose: This is the first National Resident Matching Program analysis evaluating historical patterns of international medical graduates (IMGs) in radiation oncology (RO) and providing comparison with American (MD) medical graduates (AMGs), osteopathic students (DOs), unfilled positions, and other specialties. Methods and Materials: National Resident Matching Program data for IMGs were available from 2003 to 2015, with limited data for other specialty matches. The following RO-specific figures were obtained per year: total positions available; total matched positions; number of unfilled positions; and number of IMG, AMG, and DO matches. In addition, the number of IMG matches and total matched positions were obtained for 19 other specialties. Fisher exact tests and χ{sup 2} tests were considered significant at α <.05. Results: From 2010 to 2015, 0.8% of RO matches were IMGs, a decline from 2.4% in 2003 to 2009 (P=.006). Proportions of DO matches during these intervals increased by 40% (from 1.0% to 1.4%), significantly lower than IMGs for 2003 to 2009 (P=.03) but not 2010 to 2015 (P=.26). From 2003 to 2015, the percentage of IMG matches, at 1.5%, was significantly lower than the percentage of unfilled seats, at 3.5% (P<.001). In comparison with other specialties (2003-2015), RO had the fewest IMG matches (1.5%), followed by otolaryngology (1.9%) and orthopedics (2.2%); specialties with the highest IMG proportions were internal medicine (37.1%), family medicine (35.7%), and neurology (31.1%). Conclusions: Presently, IMGs represent <1% of RO matches, the lowest among major specialties. There are several speculative factors associated with this low proportion. There are significantly more unfilled positions than those filled by IMGs; programs at risk of not matching could weigh the advantages and disadvantages of interviewing IMGs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo simulations of photoneutron activation in a medical LINAC

The first step of the present study was to simulate the γ-radioactivity produced by photoneutrons in the treatment head of a decommissioned medical LINAC. These results, obtained with MCNPX and CINDER'90, are then compared with γ-ray spectrometric measurements of parts of the treatment head. Our ultimate objective is to simulate the associated production by photonuclear reactions of pure β-emitters, which are more difficult to access experimentally than the γ-ray emitters. (authors)

43 PARTICLE ACCELERATORS↗

Medical imaging using ionizing radiation: Optimization of dose and image quality in fluoroscopy

The 2012 Summer School of the American Association of Physicists in Medicine (AAPM) focused on optimization of the use of ionizing radiation in medical imaging. Day 2 of the Summer School was devoted to fluoroscopy and interventional radiology and featured seven lectures. These lectures have been distilled into a single review paper covering equipment specification and siting, equipment acceptance testing and quality control, fluoroscope configuration, radiation effects, dose estimation and measurement, and principles of flat panel computed tomography. This review focuses on modern fluoroscopic equipment and is comprised in large part of information not found in textbooks on the subject. While this review does discuss technical aspects of modern fluoroscopic equipment, it focuses mainly on the clinical use and support of such equipment, from initial installation through estimation of patient dose and management of radiation effects. This review will be of interest to those learning about fluoroscopy, to those wishing to update their knowledge of modern fluoroscopic equipment, to those wishing to deepen their knowledge of particular topics, such as flat panel computed tomography, and to those who support fluoroscopic equipment in the clinic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A brief description of the Medical Information Computer System (MEDICS)

The Medical Information Computer System (MEDICS) is a time shared, disk oriented minicomputer system capable of meeting storage and retrieval needs for the space- or non-space-related applications of at least 16 simultaneous users. At the various commercially available low cost terminals, the simple command and control mechanism and the generalized communication activity of the system permit multiple form inputs, real-time updating, and instantaneous retrieval capability with a full range of options.

Moseley, E. C.↗

Simulating Medical Officer Occupied Time (MOOT) for Space Medical System Design, a Pilot Project

Providing and receiving medical treatment takes time away from other duties. The time is expected to vary based on the provider’s skill level, duration of the patient’s illness, specific tasks performed, and the condition’s severity. Since crew time is a limited resource, it is important to understand how MOOT will impact mission objectives. Historically, diagnostic/treatment time was estimated only for the patient by subject matter experts using a non-standard approach based on the condition as a whole. The present effort uses a Delphi approach among experts of varied training levels and based on estimates of specific medical tasks in order to more accurately assess downtime for both caregiver and patient with fewer errors.

Preston Fedor↗

Modeling Provider Creativity in Medical System Design Simulating a Medical MacGyver

This presentation describes a method for modeling provider creativity during the requirements building and risk assessment phase of medical system design. Practicing medicine in isolated, confined, and extreme environments requires providers to use limited supplies in creative ways. This is necessary to handle unexpected medical events or make better use of limited storage capacity by leaving low-use, bulky equipment behind in favor of in situ or dual-use resources. This is a highly-valued skillset in remote environments, however, the ability to simulate this care creativity computationally is difficult.

Brian Lonquich↗

Development of an Accepted Medical Condition List for Exploration Medical Capability Scoping

Future NASA human spaceflight programs are on the verge of moving beyond Low Earth Orbit (LEO) to implement missions in lunar space and ultimately Mars. The mission constraints for these types of missions are expected to be progressively challenging for integration of Human Systems requirements into the vehicle and mission architectures. Mass and volume allocations are expected to become increasingly restrictive at the same time that mission realities will drive an increasing need for crew self-sufficiency in the maintenance and repair of both vehicle systems and human systems. To meet these challenges, a systematic, traceable, and repeatable approach to identifying, defining, and prioritizing medical capabilities is required. To provide a systematic and repeatable approach to defining and prioritizing clinical capabilities for spaceflight medicine, a clear process is required for delivering a list of prioritized medical capabilities to the Systems Engineering process that will delineate the mass, power, volume, and similar needs and the trade space analysis for a given space vehicle and mission architecture.

Rebecca Blue↗

Medical implants and methods of making medical implants

A medical implant device having a substrate with an oxidized surface and a silane derivative coating covalently bonded to the oxidized surface. A bioactive agent is covalently bonded to the silane derivative coating. An implantable stent device including a stent core having an oxidized surface with a layer of silane derivative covalently bonded thereto. A spacer layer comprising polyethylene glycol (PEG) is covalently bonded to the layer of silane derivative and a protein is covalently bonded to the PEG. A method of making a medical implant device including providing a substrate having a surface, oxidizing the surface and reacting with derivitized silane to form a silane coating covalently bonded to the surface. A bioactive agent is then covalently bonded to the silane coating. In particular instances, an additional coating of bio-absorbable polymer and/or pharmaceutical agent is deposited over the bioactive agent.

42 ENGINEERING↗

Associations between environmental quality and adult asthma prevalence in medical claims data

Highlights: • Asthma is a complex condition affecting 7.4% of U.S. adults. • Asthma may be driven by multiple exposures operating in tandem. • The Environmental Quality Index measures 5 environmental domains simultaneously. • Worsening overall environmental quality is associated with increasing asthma. • Patterns vary by domain (air, water, land, built, sociodemograhic) and rurality. As of 2014, approximately 7.4% of U.S. adults had current asthma. The etiology of asthma is complex, involving genetics, behavior, and environmental factors. To explore the association between cumulative environmental quality and asthma prevalence in U.S. adults, we linked the U.S. Environmental Protection Agency's Environmental Quality Index (EQI) to the MarketScan{sup ®} Commercial Claims and Encounters Database. The EQI is a summary measure of five environmental domains (air, water, land, built, sociodemographic). We defined asthma as having at least 2 claims during the study period, 2003–2013. We used a Bayesian approach with non-informative priors, implementing mixed-effects regression modeling with a Poisson link function. Fixed effects variables were EQI, sex, race, and age. Random effects were counties. We modeled quintiles of the EQI comparing higher quintiles (worse quality) to lowest quintile (best quality) to estimate prevalence ratios (PR) and credible intervals (CIs). We estimated associations using the cumulative EQI and domain-specific EQIs; we assessed U.S. overall (non-stratified) as well as stratified by rural-urban continuum codes (RUCC) to assess rural/urban heterogeneity. Among the 71,577,118 U.S. adults with medical claims who could be geocoded to county of residence, 1,147,564 (1.6%) met the asthma definition. Worse environmental quality was associated with increased asthma prevalence using the non-RUCC-stratified cumulative EQI, comparing the worst to best EQI quintile (PR:1.27; 95% CI: 1.21, 1.34). Patterns varied among different EQI domains, as well as by rural/urban status. Poor environmental quality may increase asthma prevalence, but domain-specific drivers may operate differently depending on rural/urban status.

54 ENVIRONMENTAL SCIENCES↗

Engineering Prototype for a Compact Medical Dielectric Wall Accelerator

A compact accelerator system architecture based on the dielectric wall accelerator (DWA) for medical proton beam therapy has been developed by the Compact Particle Acceleration Corporation (CPAC). The major subsystems are a Radio Frequency Quadrupole (RFQ) injector linac, a pulsed kicker to select the desired proton bunches, and a DWA linear accelerator incorporating a high gradient insulator (HGI) with stacked Blumleins to produce the required acceleration energy. The Blumleins are switched with solid state laser-driven optical switches integrated into the Blumlein assemblies. Other subsystems include a high power pulsed laser, fiber optic distribution system, electrical charging system, and beam diagnostics. An engineering prototype has been constructed and characterized, and these results will be used within the next three years to develop an extremely compact 150 MeV system capable of modulating energy, beam current, and spot size on a shot-to-shot basis. This paper presents the details the engineering prototype, experimental results, and commercialization plans.

43 PARTICLE ACCELERATORS↗