Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Cosmic Supernova Neutrino and Gamma-Ray Backgrounds in the MeV Regime

Cosmic multimessenger backgrounds include relic diffuse components created in the early universe and contributions from individual sources. Here, we study both type Ia supernovae (SNe Ia) and core-collapse supernovae (CCSNe) contributions to the diffuse neutrino and gamma-ray backgrounds in the MeV regime referred to as DSNB and DSGB respectively. We show that the diffuse SN Ia background is 10 6 times lower (for $\overline{v}_e$) than the CCSN background making it negligible. Our predicted DSNB $\overline{v}_e$ flux at earth in the 19.3–32 MeV regime is 0.36 ν cm -2 s -1 . We also find that the DSNB flux in the energy range from 11.3 to 32 MeV varies by +29% with a change in the SFRD model from Madau & Fragos which yielded a minimum predicted flux, to the extragalactic background light reconstruction model (maximum predicted flux). The diffuse SN Ia gamma-ray background and its dependence on the progenitor supernova delay time distribution are also evaluated. Furthermore, we address the origin of the CGB (Cosmic Gamma-ray Background) in the 0.1–7 MeV regime by adding contributions from sources such as SNe Ia, CCSNe, radio-quiet Active Galactic Nuclei, Flat spectrum radio quasars (FSRQs) and Neutron star—neutron star mergers. We find that our modeled background (including uncertainties) matches the observed CGB above 1.0 MeV, but is a factor ≈2 lower than the observed flux in the 0.1–1.0 MeV range, highlighting the need for future MeV missions to establish the CGB spectrum more reliably, and to possibly identify additional sources or even source classes in the underexplored MeV band.

79 ASTRONOMY AND ASTROPHYSICS↗

High-luminosity meV-resolution single-shot hard X-ray spectrograph for cavity-based X-ray free-electron lasers

Cavity-based X-ray free-electron lasers (CBXFELs) represent a possible realization of fully coherent hard X-ray sources having high spectral brilliance along with a narrow spectral bandwidth of ∼1–50 meV, a high repetition pulse rate of ∼1 MHz, and good stability. A diagnostic tool is required to measure CBXFEL spectra with meV resolution and high luminosity on a shot-to-shot basis. We have designed a high-luminosity single-shot hard X-ray spectrograph that images 9.831 keV X-rays in a ∼200 meV spectral window with a spectral resolution of a few meV. The spectrograph is designed around angular dispersion of X-rays in Bragg diffraction from crystals. It operates close to design specifications, exhibiting a linear dispersion rate of ∼1.4 µm meV −1 and a ∼200 meV window of high-fidelity spectral imaging. The experimentally demonstrated spectral resolution is ∼20 meV; this resolution is twice as low as expected from theory primarily because the spectrograph is highly sensitive to crystal angular instabilities. The experiment was performed at the bending magnet X-ray optics testing beamline 1-BM at the Advanced Photon Source.

Bragg diffraction↗

Cosmic ray positron and negatron spectra between 20 and 800 MeV measured in 1974

A balloon-borne spark chamber magnetic spectrometer was used to measure separate spectra of positrons and negatrons in two flights during summer, 1974. The total electron flux is about 0.3 m(-2) s(-1) sr(-1) MeV(-1) between 70 and 800 MeV, and increases toward lower energies. The positron spectrum decreases sharply toward lower energies from a value of about 0.08 m(-2) s(-1) sr(-1) MeV(-1) at 650 MeV, and only upper limits are obtained for positrons below 200 MeV. At energies above 180 MeV, the spherically symmetric Fokker-Planck equation provides reasonable fits to both the positron and total electron data. At energies below 180 MeV the data are consistent with a continuation of the same diffusion coefficient and local source of negatrons, or a change in the diffusion coefficient to a constant value.

Hartman, R. C.↗

Diffuse 0.511 MeV line emission and the distribution of positron annihilation in the galaxy

We model the distribution in the Galaxy of 0.511 MeV line emission and the implied positron annihilation using plausible distributions based on observations at other photon energies. We use 0.511 MeV line observations from the Galactic center and from directions away from the Galactic center to normalize the two-dimensional 0.511 MeV sky maps. We find that in order to understand all of the available data it is necessary to invoke the presence of a time-variable component of 0.511 MeV line emission in addition to an underlying diffuse component. The large 0.511 MeV fluxes observed with broad field of view detectors, such as the SMM gamma-ray spectrometer, can be reconciled with the small fluxes seen with narrow field-of-view instruments (GRIS and OSSE) from directions away from the Galactic center if the diffuse emission follows the distribution of Galactic novae for which the recently detected 0.511 MeV line emission from the Galactic center with OSSE is predominantly of diffuse origin. For future GRIS and HEXAGONE observations from the direction of the Galactic center we predict a minimum 0.511 MeV line flux of (6.0 +/- 0.9) x 10 exp -4 photons/sq cm/s.

Skibo, J. G.↗

Towards Construction of a Novel Nanometer-Resolution MeV-STEM for Imaging Thick Frozen Biological Samples

Driven by life-science applications, a mega-electron-volt Scanning Transmission Electron Microscope (MeV-STEM) has been proposed here to image thick frozen biological samples as a conventional Transmission Electron Microscope (TEM) may not be suitable to image samples thicker than 300–500 nm and various volume electron microscopy (EM) techniques either suffering from low resolution, or low speed. The high penetration of inelastic scattering signals of MeV electrons could make the MeV-STEM an appropriate microscope for biological samples as thick as 10 μm or more with a nanoscale resolution, considering the effect of electron energy, beam broadening, and low-dose limit on resolution. The best resolution is inversely related to the sample thickness and changes from 6 nm to 24 nm when the sample thickness increases from 1 μm to 10 μm. To achieve such a resolution in STEM, the imaging electrons must be focused on the specimen with a nm size and an mrad semi-convergence angle. This requires an electron beam emittance of a few picometers, which is ~1000 times smaller than the presently achieved nm emittance, in conjunction with less than 10 -4 energy spread and 1 nA current. We numerically simulated two different approaches that are potentially applicable to build a compact MeV-STEM instrument: (1) DC (Direct Current) gun, aperture, superconducting radio-frequency (SRF) cavities, and STEM column; (2) SRF gun, aperture, SRF cavities, and STEM column. Beam dynamic simulations show promising results, which meet the needs of an MeV-STEM, a few-picometer emittance, less than 10 -4 energy spread, and 0.1–1 nA current from both options. Also, we designed a compact STEM column based on permanent quadrupole quintuplet, not only to demagnify the beam size from 1 μm at the source point to 2 nm at the specimen but also to provide the freedom of changing the magnifications at the specimen and a scanning system to raster the electron beam across the sample with a step size of 2 nm and the repetition rate of 1 MHz. This makes it possible to build a compact MeV-STEM and use it to study thick, large-volume samples in cell biology.

36 MATERIALS SCIENCE↗

C 13 ( n , 2 n γ ) C 12 γ -ray production in the 14–16 MeV incident neutron energy range

We report γ-ray emission from 12 C and 13 C samples irradiated with deuterium-tritium fusion neutrons was experimentally measured at the Omega Laser Facility and at the Ohio University Edwards Accelerator Laboratory. The intent of these measurements was to determine the feasibility of using 13 C-based plastic ablators with embedded 12 C layers for “dark mix” diagnosis of inertial confinement fusion implosions. Spectrally resolved measurements at Ohio University identified significant 4.44-MeV γ-ray emission from the 13 C(n, 2nγ) 12 C-L1 reaction channel. The recorded 4.44-MeV 13 C signal was compared against emission from an identically irradiated 12 C target with known 12 C(n, n'γ) 12 C-L1 cross section, which resulted in an average 13 C(n, 2nγ) 12 C-L1 cross section of 117 ± 17 mb over the incident neutron energy distribution range from 14.4 to 15.8 MeV. Integrated 13C γ -ray signals above 2.9 MeV recorded with the Gas Cherenkov Detector at Omega exceeded MCNP6.1 predictions by a factor of 3. The additional signal was attributed to 4.44-MeV γs resulting in an inferred 13 C(n, 2nγ) 12 C-L1 cross section of 95 ± 11 mb at 14.1-MeV average incident neutron energy. As a result, the 13 C-based “dark mix” diagnostic concept was deemed infeasible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of the neutron cross section on argon between 95 and 720 MeV

We report an extended measurement of the neutron cross section on argon in the energy range of 95-720 MeV. The measurement was obtained with a 4.3-hour exposure of the Mini-CAPTAIN detector to the WNR/LANSCE beam at LANL. Compared to an earlier analysis of the same data, this extended analysis includes a reassessment of systematic uncertainties, in particular related to unused wires in the upstream part of the detector. Using this information we doubled the fiducial volume in the experiment and increased the statistics by a factor of 2.4. Here we also shifted the analysis from energy bins to time-of-flight bins. This change reduced the overall considered energy range, but improved the understanding of the energy spectrum of incoming neutrons in each bin. Overall, the new measurements are extracted from a fit to the attenuation of the neutron flux in five time-of-flight regions: 140ns-180ns, 120ns-140ns, 112ns-120ns, 104ns-112ns, 96ns-104ns. The final cross sections are given for the flux-averaged energy in each time-of-flight bin with statistical and systematic (syst) uncertainties: σ(146 MeV) = 0.60 $^{+0.14}_{-0.14}$ ±0.08(syst) b, σ(236 MeV) = 0.72 $^{+0.10}_{-0.10}$ ± 0.04(syst) b, σ(319 MeV) = 0.80 $^{+0.13}_{-0.12}$ ±0.040(syst) b, σ(404 MeV) = 0.74 $^{+0.14}_{-0.09}$ ±0.04(syst) b, σ(543 MeV) = 0.74 $^{±0.09}_{-0.09}$ ± 0.04(syst) b.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of MeV gamma-ray events during May 1967 from ERS-18

Gamma-ray fluxes between 25 keV and 6 MeV were observed by instruments aboard the Environmental Research Satellite-18 (ERS-18)during the great solar flares of May 21 and May 23, 1967. Measurements were made with a 6.35-cm-diameter by 7.65-cm-long Nal scintillation counter with five differential channels between 0.25 and 6.0 MeV. Data obtained during the event at 1945 UT on May 23, 1967, can be fitted by a two-part, power-law, differential-number spectrum. One part is of spectral index 3.2 between 8 keV and 0.6 MeV, and the other is of spectral index 1.2 above 0.6 MeV. An upper limit of 0.52 photons is set for 2.23 MeV line strength for this event. In all three bursts, tentatively associated with white light flares, the MeV-range fluxes declined more slowly than the 25-keV fluxes.

Gruber, D. E.↗

Time dependences of the 0.51 and 2.2 MeV lines in solar flares

The time dependence of the 0.51 MeV line in solar flares is determined by the following factors: variation with time of the rate of nuclear reactions which produce the positron emitters; mean lives of the positron emitters; slowing-down of the positrons which depends on the ambient density and magnetic field; and annihilation or positronium formation times of the positrons with free or bound electrons. The discussion is limited to the observed intensity-time profile of a 0.35-8 MeV gamma-ray emission and of a 0.51-MeV line calculated for three different ambient densities in the annihilation region. Major conclusions are that (1) MeV electrons and protons of at least 30 MeV/nuc have similar time dependences and hence a common origin in the flare region, which support a two-phase acceleration model in solar flares; and (2) the delayed character of the 0.51-MeV emission is clearly defined, where at a time when the rate of nuclear reactions is zero, there still is considerable 0.51-MeV emission.

Ramaty, R.↗

Measurements of galactic plane gamma ray emission in the energy range from 10 - 80 MeV

A spark chamber gamma ray telescope was developed and flown to observe diffuse gamma ray emission from the central region of the galaxy. The extension of observations down to 10 MeV provides important new data indicating that the galactic diffuse gamma ray spectrum continues as a power law down to about 10 MeV, an observation in good agreement with recent theoretical predictions. Data from other experiments in the range from 100 keV to 10 MeV show a significant departure from the extension of the power-law fit to the medium energy observations reported here, possibly indicating that a different mechanism may be responsible for the emissions below and above a few MeV. The intensity of the spectrum above 10 MeV implies a galactic electron spectrum which is also very intense down to about 10 MeV. Electrons in this energy range cannot be observed in the solar cavity because of solar modulation effects. The galactic gamma ray data are compared with recent theoretical predictions.

Bertsch, D. L.↗

Measurements of galactic plane gamma-ray emission in the energy range 10-80 MeV

A spark chamber gamma ray telescope was developed and flown to observe diffuse gamma ray emission from the central region of the galaxy. The extension of observations down to 10 MeV provides important new data indicating that the galactic diffuse gamma ray spectrum continues as a power law down to about 10 MeV, an observation in good agreement with recent theoretical predictions. Data from other experiments in the range from 100 keV to 10 MeV show a significant departure from the extension of the power-law fit to the medium energy observations reported here, possibly indicating that a different mechanism may be responsible for the emissions below and above a few MeV. The intensity of the spectrum above 10 MeV implies a galactic electron spectrum which is also very intense down to about 10 MeV. Electrons in this energy range cannot be observed in the solar cavity because of solar modulation effects. The galactic gamma ray data are compared with recent theoretical predictions. Previously announced in STAR as N83-17444

Bertsch, D. L.↗

Galactic 0.511 MeV line emission

Observations over two decades with various balloon-borne instruments and instruments on HEAO 3, SMM, and Compton Gamma Ray Observatory (CGRO) have revealed the existence of strong 0.511 MeV line emission from the direction of the Galactic center. We have attempted to fit the spatial distribution of this emisssion with distributions of various Galactic constituents, but found that none of these distributions alone could fit the data. Of the assumed distributions, those of Galactic novae and hot (10(exp 8) K) plasma are the most strongly peaked at the Galactic center. But we found that the 0.511 MeV line emission is even more strongly peaked. This new result is the direct consequence of the analysis of recent data obtained with the OSSE instrument on CGRO. We have thus considered two-component models consisting of an enhanced central Galactic component superposed on a Galactic plane component given by any one of our previously assumend distributions. For the central Galactic component we take either a single point source at the location of the source of annihilation radiation 1E 1740.7-2942 or an extended spheroidal distribution of several hundred parsecs in size. We find acceptable fits in both cases. We suggest that this additional component of the emission from the Galactic center region is due to positrons produced near one or more black holes. Such a component was also suggested by the variability of the 0.511 MeV line flux observed with balloon-borne high-resolution detectors. To produce the very narrow line observed by these high-resolution detectors at almost precisely 0.511 MeV the positrons must escape from the vicinity of the holes and annihilate in the surrounding interstellar medium. We have reexamined the issure of the time variability of the 0.511 MeV line emission. Although the significance of the variability implied by all of the earlier observations is diminished by a large number of recent OSSE observations which show no variability, the latter measurements merely indicate that the flux remained relatively constant only over a period of about 1 year (1991-1992). Positron producation in the Galactic center region by a small number of variable sources would lead to variable 0.511 MeV line emission. The timescale of the variation depends on the density of the gas in which the positrons annihilate. It could be as short as several months if the annihilation is in dense moleduar clouds, but would be much longer and essentially undetectable if the positrons annihilate in lower density interstellar gas.

Ramaty, R.↗

Focused interplanetary transport of approximately 1 MeV solar energetic protons through self-generated Alfven waves

We present a model of the focused transport of approximately 1 MeV solar energetic protons through interplanetary Alfven waves that the protons themselves amplify or damp. It is based on the quasi-linear theory but with a phenomenological pitch angle diffusion coefficient in the 'resonance gap.' For initial Alfven wave distributions that give mean free paths greater than approximately 0.5 AU for approximately 1 MeV protons in the inner heliosphere, the model predicts greater than roughly an order of magnitude amplification (damping) in the outward (inward) propagating resonant Alfven waves at less than or approximately equal to o.3 AU heliocentric distance. As the strength of proton source is increased, the peak differential proton intensity at approximately 1 MeV at 1 AU increases to a maximum of approximately 250 particles (/(sq cm)(s)(sr)(MeV)) and then decreases slowly. It may be attenuated by a factor of 5 or more relative to the case without wave evolution, provided that the proton source is sufficiently intense that the resulting peak differential intensity of approximately 1 MeV protons at 1 AU exceeds approximately 200 particles (/(sq cm)(s)(sr)(MeV)). Therefore, in large solar proton events, (1) one may have to take into account self-amplified waves in studying solar particle propagation, (2) the number of accelerated protons escaping from a flare or interplanetary shock may have been underestimated in past studies by a significant factor, and (3) accelerated protons escaping from a traveling interplanetary shock at r less than or approximately equal to 0.3 AU should amplify the ambient hydromagnetic waves siginificantly to make the shock an efficient accelerator, even if initially the mean free path is greater than or approximately equal to 1 AU.

Ng, C. K.↗

Development of a Quasi-monoenergetic 6 MeV Gamma Facility at NASA Goddard Space Flight Center

The 6 MeV Gamma Facility has been developed at NASA Goddard Space Flight Center (GSFC) to allow in-house characterization and testing of a wide range of gamma-ray instruments such as pixelated CdZnTe detectors for planetary science and Compton and pair-production imaging telescopes for astrophysics. The 6 MeV Gamma Facility utilizes a circulating flow of water irradiated by 14 MeV neutrons to produce gamma rays via neutron capture on oxygen (O-16(n,p)N-16 yields O-16* yields O-16 + gamma). The facility provides a low cost, in-house source of 2.742, 6.129 and 7.117 MeV gamma rays, near the lower energy range of most accelerators and well above the 2.614 MeV line from the Th-228 decay chain, the highest energy gamma ray available from a natural radionuclide. The 7.13 s half-life of the N-16 decay allows the water to be irradiated on one side of a large granite block and pumped to the opposite side to decay. Separating the irradiation and decay regions allows for shielding material, the granite block, to be placed between them, thus reducing the low-energy gamma-ray continuum. Comparison between high purity germanium (HPGe) spectra from the facility and a manufactured source, Pu-238/C-13, shows that the low-energy continuum from the facility is reduced by a factor approx. 30 and the gamma-ray rate is approx.100 times higher at 6.129 MeV.

NASA↗

Reaching For New Physics With MeV-scale Reconstruction In The MicroBooNE LArTPC Neutrino Detector

Large neutrino liquid argon time projection chamber (LArTPC) experiments can broaden their physics reach by reconstructing MeV-Scale energy depositions, or blips, in their data. We demonstrate new calorimetric and particle discrimination capabilities at the MeV scale using reconstructed blips in MicroBooNE LArTPC data at Fermilab. A concentration of low-energy ($<$3 MeV) blips is observed around fiberglass mechanical support struts along the TPC edges, with spectral features consistent with the Compton edge of the 2.614 MeV $^{208}$Tl decay $\gamma$ ray. With these features we perform the electron energy scale calibration to few-percent precision and yield the specific activity of $^{208}$Tl in the struts, $(11.7 \pm 0.2 \text{(stat)} \pm 2.8 \text{(syst)})$ Bq/kg. Using cosmogenic blips above 3 MeV, we demonstrate the ability of large LArTPCs to discriminate low-energy proton and electron depositions. An enriched low-energy proton sample selected with this technique is smaller in data than in dedicated CORSIKA simulations, pointing to possible mismodeling in CORSIKA incident cosmic fluxes or Geant4 particle transport. These methods are applied to MicroBooNE's inclusive single-photon search, which reported a 2.2$\sigma$ excess below 600 MeV in shower energy for events with no reconstructed protons. By identifying and classifying blips near single-photon events selected by the WireCell reconstruction framework, a more comprehensive labeling of nearby hadronic activity is established: blips upstream of the shower axis indicate previously unidentified final-state protons, while elevated blip counts at wide angles signal final-state neutrons. Taken together with MiniBooNE's long-standing low-energy excess (LEE) and MicroBooNE electron-like and sterile neutrino searches disfavored as possible explanations of the MiniBooNE anomaly, this analysis motivates an expanded exploration of the single-photon channel in Fermilab's short-baseline LArTPC program. This thesis documents the current status of this enhanced analysis, which will form a key part of MicroBooNE's final low-energy-excess results.

Andrade Aldana, Diego Armando [IIT, Chicago (main)↗

Experimental study of energy-dependent angular broadening of MeV electron beams for high-resolution imaging in thick samples

In scanning transmission electron microscopy (STEM), spatial resolution is primarily influenced by the projected size of the electron probe within the specimen. In thin samples, a large semi-convergence angle enables a tightly focused beam and sub-nanometer resolution. However, in thick specimens, resolution is fundamentally limited by transverse beam broadening from multiple large-angle scattering events—for example, a probe with 10 mrad angular divergence can broaden by ∼100 nm over a 10 μm path. Since this broadening scales inversely with beam energy, MeV-STEM offers a promising route for high-resolution imaging in thick materials. To quantitatively assess this effect, we performed high-precision measurements at UCLA’s PEGASUS beamline, characterizing beam divergence and intensity profiles for 3–8 MeV electrons transmitted through a wedged-silicon sample of varying thickness. Our results reconcile discrepancies among analytical models and validate Monte Carlo simulations. Here, we find that increasing beam energy from 3.0 to 5.8 MeV reduces angular broadening by a factor of 2.6, with diminishing returns observed at 7.6 MeV. These findings provide a quantitative framework for optimizing MeV-STEM parameters in high-resolution imaging of thick biological and microelectronic specimens, and for guiding beam energy selection in other advanced imaging modes beyond STEM.

36 MATERIALS SCIENCE↗

Monte Carlo Simulation of Electron Interactions in an MeV-STEM for Thick Frozen Biological Sample Imaging

A variety of volume electron microscopy techniques have been developed to visualize thick biological samples. However, the resolution is limited by the sliced section thickness (>30–60 nm). To preserve biological samples in a hydrated state, cryo-focused ion beam scanning electron microscopy has been developed, providing nm resolutions. However, this method is time-consuming, requiring 15–20 h to image a 10 μm thick sample with an 8 nm slice thickness. There is a pressing need for a method that allows the rapid and efficient study of thick biological samples while maintaining nanoscale resolution. The remarkable ability of mega-electron-volt (MeV) electrons to penetrate thick biological samples, even exceeding 10 μm in thickness, while maintaining nanoscale resolution, positions MeV-STEM as a suitable microscopy tool for such applications. Our research delves into understanding the interactions between MeV electrons and frozen biological specimens through Monte Carlo simulations. Single elastic scattering, plural elastic scattering, single inelastic scattering, and plural inelastic scattering events have been simulated. The electron trajectories, the beam profile, and the intensity change of electrons in each category have been investigated. Additionally, the effects of the detector collection angle and the focal position of the electron beam were investigated. As electrons penetrated deeper into the specimen, single and plural elastic scattered electrons diminished, and plural inelastic scattered electrons became dominant, and the beam profile became wider. Even after 10 μm of the specimen, 42% of the MeV electrons were collected within 10 mrad. This confirms that MeV-STEM can be employed to study thick biological samples.

electron specimen interaction↗

Stable and tunable MeV $$\gamma$$-ray generation via dual-laser inverse Thomson scattering from a laser-plasma accelerator

Abstract Inverse Thomson scattering from laser-plasma accelerators offers a pathway to compact, tunable MeV $$\gamma$$ -ray sources for reduced-dose radiography and enhanced performance in nuclear resonance fluorescence (NRF)-based isotope identification. However, photon yield and spectral quality are often limited by constraints on interaction geometry and scatter-laser tunability. Here we demonstrate a MeV $$\gamma$$ -ray source based on a dual-laser inverse Thomson scattering configuration driven by a 100-TW laser-plasma accelerator. Electron beams tunable from 122 to 204 MeV with $$<5$$ mrad divergence and $$<1$$ mrad pointing stability generate $$\gamma$$ rays with peak energies from 276 keV to 1.2 MeV and yields up to $$2\times 10^{7}$$ photons per shot. By independently controlling the interaction position and the scatter-pulse duration, we experimentally match the scatter pulse to the walk-off-limited interaction length. Extending the scatter pulse to 200 fs increases photon production by approximately $$15\%$$ while maintaining operation in the linear Thomson regime, thereby preserving narrow spectral bandwidth and controlled radiation divergence. Radiographic characterization demonstrates MeV-level penetration and $$\approx 0.1$$ mm spatial resolution, while stable operation is sustained over multi-hour timescales across multiple days. These results show that interaction-length optimization provides a scalable strategy for improving photon yield, spectral control, and operational stability in compact laser-plasma-accelerator-driven $$\gamma$$ -ray sources.

Tsai, Hai-En↗