Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Characterizing the energy resolution of the MicroBooNE LArTPC at the MeV scale using monoenergetic features of $^{208}$Tl decays

A detailed understanding of the capabilities and fidelity of low-energy reconstruction is crucial for taking advantage of MeV-scale neutrino physics opportunities in liquid argon time projection chambers (LArTPCs). This study presents a measurement of the resolution of reconstructed energy in the MicroBooNE LArTPC at $\approx 1.5$ MeV. The characterization is performed using monoenergetic signals generated by $2.614$ MeV $γ$-rays from $^{208}$Tl decays undergoing pair production in the detector. The resolution is found to be ($7.52 \pm 0.78 \text{(stat)} \pm 0.92 \text{(syst)}$)%. This value is consistent with the MicroBooNE simulation prediction of ($9.70 \pm 0.65 \text{(stat)}$)% at the $1.6 σ$ level. This study represents the first ever measurement of LArTPC energy resolution at the MeV scale and provides a pathway for monoenergetic energy calibrations in future experiments using LArTPC detectors.

Abratenko, P. [Tufts U.]↗

COCOA: A compact Compton camera for astrophysical observation of MeV-scale gamma rays

COCOA (COmpact COmpton cAmera) is a next-generation gamma-ray telescope designed for astrophysical observations in the MeV energy range. The detector comprises a scatterer volume employing the LiquidO detection technology and an array of scintillating crystals acting as absorber. Surrounding plastic scintillator panels serve as a veto system for charged particles. The detector's compact, scalable design enables flexible deployment on microsatellites or high-altitude balloons. Gamma rays at MeV energies have not been well explored historically (the so-called "MeV gap") and COCOA has the potential to improve the sensitivity in this energy band.

79 ASTRONOMY AND ASTROPHYSICS↗

Response of the Verwey transition in magnetite to controlled point-like disorder induced by 2.5 MeV electron irradiation

Controlled point-like disorder induced by low temperature 2.5 MeV electron irradiation was used to probe the nature of the Verwey transition in magnetite, Fe 3 O 4 . Two large single crystals, one with optimal transition temperature, T V ≈ 121 K, and another with T V ≈ 109 K, as well as magnetite magnetosome nanocrystals harvested from the lysed cells of the marine magnetotactic vibrio Magnetovibrio blakemorei strain MV-1, T V ≈ 110 K, were examined. Temperature-dependent resistivity is consistent with the semiconductor-to-semiconductor (insulator) sharp, step-like Verwey transition from a state with a small bandgap of around 60 meV to a state with a large bandgap of about 300 meV. The irradiation causes an up-shift of the resistivity curves above the transition without transition smearing or broadening. It also causes an apparent down-shift of the resistivity maximum at high temperatures. In the lower crystal, the electron irradiation drives the transition temperature into a “forbidden” interval of T V , believed to separate the first order from the second order phase transition. Contrary to this belief, the transition itself remains sharp and hysteretic without a significant change in the hysteresis width indicating the strong 1st order character of the Verwey transition for all TV values. The separate 2nd order - looking transition is likely due to sample inhomogeneities. Here we conclude that the sudden change of the bandgap accompanied (or driven) by the monoclinic distortion and the change of magnetic anisotropy is the reason for the Verwey transition in magnetite and the effect of additional disorder is mostly in the smearing of the sharp gap edges near the Fermi level.

36 MATERIALS SCIENCE↗

Lineshape response of plastic scintillator to pair production of 4.44 MeV γ’s

We measure the distribution of energy deposited in a 40 × 88 mm plastic scintillator by e + e – pair production of 4.44 MeV γ-rays. He, we observe the double-escape peak of 3.42 MeV from pair production by tagging 511 keV annihilation radiation in two high-Z scintillators. The source is a standard commercial neutron source using α-emitting 241 Am encapsulated with 9 Be, which has a reaction branch feeding the first I π = 2 + state of 12 C making the 4.44 MeV γ-rays. We demonstrate the extraction of the double-escape peak from the large neutron-produced backgound, and explore some of the features and difficulties of this technique with our apparatus.

Beta calibration↗

Multiple Coulomb scattering in acrylic of a 221.3 MeV therapeutic proton beam

Measurements of multiple Coulomb scattering (MCS) distributions for 221.3 MeV therapeutic protons are presented using a novel detector system comprised of a thin scintillator, a pellicle mirror, and a digital camera. The MCS distributions were characterized for three acrylic phantoms of varying lengths and for two biological density-equivalent phantoms simulating bone and muscle. Additionally, beam profiles were measured across an energy range of 80.3–221.3 MeV in 20 MeV increments. The observed energy dependence of the photon yields is consistent with the tabulated stopping power values. Finally, the experimental results are benchmarked against Geant4 simulations, demonstrating consistent agreement and validating the capability of the detector system for radiology measurements.

Digital camera↗

Multi-objective Bayesian active learning for MeV-ultrafast electron diffraction

Ultrafast electron diffraction using MeV energy beams(MeV-UED) has enabled unprecedented scientific opportunities in the study of ultrafast structural dynamics in a variety of gas, liquid and solid state systems. Broad scientific applications usually pose different requirements for electron probe properties. Due to the complex, nonlinear and correlated nature of accelerator systems, electron beam property optimization is a time-taking process and often relies on extensive hand-tuning by experienced human operators. Algorithm based efficient online tuning strategies are highly desired. Here, we demonstrate multi-objective Bayesian active learning for speeding up online beam tuning at the SLAC MeV-UED facility. The multi-objective Bayesian optimization algorithm was used for efficiently searching the parameter space and mapping out the Pareto Fronts which give the trade-offs between key beam properties. Such scheme enables an unprecedented overview of the global behavior of the experimental system and takes a significantly smaller number of measurements compared with traditional methods such as a grid scan. This methodology can be applied in other experimental scenarios that require simultaneously optimizing multiple objectives by explorations in high dimensional, nonlinear and correlated systems.

43 PARTICLE ACCELERATORS↗

Compact spectroscopy of keV to MeV X-rays from a laser wakefield accelerator

We reconstruct spectra of secondary X-rays from a tunable 250–350 MeV laser wakefield electron accelerator from single-shot X-ray depth-energy measurements in a compact (7.5 × 7.5 × 15 cm), modular X-ray calorimeter made of alternating layers of absorbing materials and imaging plates. X-rays range from few-keV betatron to few-MeV inverse Compton to > 100 MeV bremsstrahlung emission, and are characterized both individually and in mixtures. Geant4 simulations of energy deposition of single-energy X-rays in the stack generate an energy-vs-depth response matrix for a given stack configuration. An iterative reconstruction algorithm based on analytic models of betatron, inverse Compton and bremsstrahlung photon energy distributions then unfolds X-ray spectra, typically within a minute. We discuss uncertainties, limitations and extensions of both measurement and reconstruction methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Robust unfolding of MeV x-ray spectra from filter stack spectrometer data

Here, we present an inversion method capable of robustly unfolding MeV x-ray spectra from filter stack spectrometer (FSS) data without requiring an a priori specification of a spectral shape or arbitrary termination of the algorithm. Our inversion method is based upon the perturbative minimization (PM) algorithm, which has previously been shown to be capable of unfolding x-ray transmission data, albeit for a limited regime in which the x-ray mass attenuation coefficient of the filter material increases monotonically with x-ray energy. Our inversion method improves upon the PM algorithm through regular smoothing of the candidate spectrum and by adding stochasticity to the search. With these additions, the inversion method does not require a physics model for an initial guess, fitting, or user-selected termination of the search. Instead, the only assumption made by the inversion method is that the x-ray spectrum should be near a smooth curve. Testing with synthetic data shows that the inversion method can successfully recover the primary large-scale features of MeV x-ray spectra, including the number of x-rays in energy bins of several-MeV widths to within 10%. Fine-scale features, however, are more difficult to recover accurately. Examples of unfolding experimental FSS data obtained at the Texas Petawatt Laser Facility and the OMEGA EP laser facility are also presented.

47 OTHER INSTRUMENTATION↗

Diagnostic development and needs for laser driven MeV x-ray radiography

Laser-driven MeV x-ray radiography of dynamic, dense objects demands a small, high flux source of energetic x-rays to generate an image with sufficient quality. Understanding the multi-MeV x-ray spectrum underscores the ability to extrapolate from the current laser sources to new future lasers that might deploy this radiography modality. Here, in this study, we present a small study of the existing x-ray diagnostics and techniques. We also present work from National Ignition Facility-Advanced Radiographic Capability, where we deploy three diagnostics to measure the x-ray spectrum up to 30 MeV. Finally, we also discuss the needs and developments of two new diagnostics: a single crystal scintillator spectrometer and a fast decay activation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MeV x-ray production from a petawatt laser in the regime of a relativistically transparent preplasma, with applications to radiography

Bright sources of mega-electron volt (MeV) x-rays have many unique applications, including nuclear physics, radiation oncology, and imaging high areal density systems. High intensity lasers (>1018 W cm−2) incident on mm-thick metal targets can deliver MeV x-rays via the bremsstrahlung process, providing sources with ultrashort duration (∼ps) and small source size (∼100 μm). Here, we report on a reproducible regime of laser-driven MeV x-ray sources, where the x-ray dose can be further increased by 60% by coating the metal target with micrometers of plastic. High fidelity numerical simulations indicate that the interaction is a result of relativistic transparency in the preplasma. Though relativistic transparency is present in both cases, the greater sound speed and smaller ion inertia of the plastic target allow the laser to more deeply penetrate and couple more efficiently to electrons. Radiography with this system demonstrates a resolving power < 300 μm, important for imaging applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of machine learning techniques for fast MeV x-ray spectra unfolding from filter stack spectrometer data

Recovery of MeV x-ray spectra from detector signals is difficult because the response matrix inversion is ill-conditioned and current methods are too slow for high-repetition-rate experiments. In this work, we make use of neural networks to unfold MeV x-ray spectra from measurements obtained with a filter stack spectrometer at rates of near 40 Hz. The neural network was trained on synthetic data and tested on both synthetic and experimental data, the latter obtained in two separate experiments performed at the Omega EP laser facility. We show here that this unfolding method has good performance on synthetic data and that it is a promising option for experimental data of up to 40 MeV. The accuracy on experimental data is verified by using a simple forward model to compare against measured values.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Properties of states near 𝐸 𝑥 = 6 MeV in 18 Ne through 17 F +𝑝 scattering

The rate of energy production in the hot-CNO cycle and breakout to the rapid-proton capture process in Type I X-ray bursts is strongly related to the 14 O⁡(𝛼,𝑝)⁢ 17 F reaction rate. The properties of states in 18 Ne near 𝐸 𝑥 = 6.1–6.3 MeV are important for understanding the 14 O⁡(𝛼,𝑝)⁢ 17 F reaction rate. In order to study 18 Ne resonances around this energy region, the RESOLUT radioactive-ion beam facility at Florida State University was used to perform 17 F⁡(𝑝,𝑝)⁢ 17 F elastic scattering on a polypropylene target under inverse kinematics. Scattered protons were detected in a silicon-strip detector array while recoiling 17 F ions were detected in coincidence in a gas ionization detector. An 𝑅-matrix analysis of measured cross sections was conducted along with a reanalysis of data from previous 17 F +𝑝 measurements. All the data analyzed are well described by a consistent set of parameters with a 1 − assignment for a state at 6.14(1) MeV. A second comparable solution is also found with a 3 − assignment for the 6.14(1) MeV state. There is no conclusive evidence supporting one of the two solutions over the other. The rates of the 14 O⁡(𝛼,p)⁢ 17 F reaction that are determined from the two solutions differ by up to an order of magnitude.

6 ≤ A ≤ 19↗

First Event-by-Event Identification of Cherenkov Radiation from Sub-Mev Particles in Liquid Argon

This Letter reports the event-by-event observation of Cherenkov light from sub-MeV electrons in a high scintillation light-yield liquid argon detector by the coherent CAPTAIN-Mills (CCM) experiment. The CCM200 detector, located at Los Alamos National Laboratory, instruments seven tons (fiducial volume) of liquid argon with 200 eight-inch photomultiplier tubes, 80% of which are coated in a wavelength-shifting material and the remaining 20% are uncoated. In the prompt time region of an event, defined as - 6 ≤ t < 0 ns relative to the event start time t = 0 , the uncoated photomultiplier tubes are primarily sensitive to visible Cherenkov photons. Using gamma rays from a Na 22 source for production of sub-MeV electrons, we isolated prompt Cherenkov light with > 5 σ confidence and developed a selection to obtain a low-background electromagnetic sample. This is the first event-by-event observation of Cherenkov photons from sub-MeV electrons in a high-yield scintillator detector and represents a milestone in low-energy particle detector development.

Aguilar-Arevalo, A. A. [UNAM, Mexico]↗

Validation of neutron-induced reactions on natural carbon using an active target at neutron energies up to 22 MeV at LANSCE

A single crystal chemical vapor deposited (sCVD) diamond detector is used as an active target to measure neutron-induced reactions on natural carbon using the neutrons produced by spallation, with a broad energy spectrum at LANSCE. Additionally, the neutron-induced reactions are detected in the diamond as low as E n = 400 keV and up to approximately 100 MeV. Relative cross sections for C 12 ( n , α 0 ) , C 12 ( n , p 0 ) , C 12 ( n , d 0 + p 1 ) , and C 13 ( n , α 0 ) are reported up to E n = 22 MeV and comparisons on detected pulse-height spectra and detector response of scattering reactions are made with GEANT4 simulations using the ENDF/B-VIII.0 evaluated nuclear data library up to 20 MeV. The results are compared with past experimental data, including other works that incorporate diamond detectors as an active carbon target. In addition, R-matrix calculations for the C 13 + n system are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fission product yields from the 238 U ( n,f ) reaction at E n = 4.6 MeV

Here, we present cumulative fission product yields from the 238 U (n, f) reaction at an incident energy of 4.6 MeV for fission products with half-lives from less than one second to several hours. We employed direct γ-ray spectroscopy to measure unseparated fission products with a conventional neutron activation analysis and a cyclic activation technique using the RApid Belt-driven Irradiated Target Transfer System (RABITTS). Yields were determined for 78 isotopes and isomers, covering the mass range 84 ≤ A ≤ 148 and the charge range from 33(As) ≤ Z ≤ 58(Ce). Our experimental cumulative yields are compared to the literature and evaluated data at E n ≈0.5 MeV from ENDF/B-VIII.0 and JEFF-3.3 libraries and with theoretical models using the GEF and FREYA codes at E n =4.6 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Differential cross sections of the 16 O (𝑛,𝛼) reaction at neutron energies from 3.8 to 15 MeV

The importance of studying the 16 O (𝑛,𝛼) reaction is motivated by multiple nuclear applications which rely on an accurate nuclear reaction data library for oxygen. Discrepancies between past experimental data on the 16 O (𝑛,𝛼) 13 C reaction and its time-reverse 13 C ⁡(𝛼,𝑛) 16 O reaction have led to various different nuclear data evaluations. Here, we have measured 16 O (𝑛,𝛼) reaction cross sections using the LENZ instrument with the unmoderated white neutron source at LANSCE. Results from 2016/2017 data are discussed and used to benchmark the mcnp and geant simulations of the LENZ experimental setup. We report partial differential cross sections of 16 O (𝑛,𝛼 0 ) at 𝐸 𝑛 = 3.8–15 MeV and 16 O ⁡(𝑛,𝛼 1 +𝛼 2 +𝛼 3 ) at 𝐸 𝑛 =9–15 MeV, based on the new measurement in 2021. The resonances that we observed are in good agreement with the levels in 17 O that were previously measured. The LENZ cross sections are in better agreement with the ENDF/B-VIII.0 evaluation than the with reduced cross section found in ENDF/B-VII.1 up to 6 MeV. However, the current results for 16 O ⁡(𝑛,𝛼 0 ) 13 C g.s. appear to be in the best agreement over the entire energy range with that of JENDL/AN-2005 (ENDF/B-VI.0).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for MeV electron recoils from dark matter in EXO-200

We present a search for electron-recoil signatures from the charged-current absorption of fermionic dark matter using the EXO-200 detector. We report an average electron-recoil background rate of 6.8×10 4 ⁢cts ⁢kg −1 yr −1 keV −1 above 4 MeV and find no statistically significant excess over our background projection. Using a total 136 Xe exposure of 234.1 kg yr, we exclude new parameter space for the charged-current absorption cross section for dark matter masses between 𝑚𝜒=2.6–11.6 MeV with a minimum of 6×10 −51 cm 2 at 8.3 MeV at the 90% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of Born cross sections for e + e − → Λ c + Λ ¯ c ( 2595 ) − + c . c . and e + e − → Λ c + Λ ¯ c ( 2625 ) − + c . c . at s = 4918.0 and 4950.9 MeV

Using e + e − collision data collected with the BESIII detector operating at the BEPCII collider, the Born cross sections of e + e − → Λ c + Λ ¯ c ( 2595 ) − + c . c . and e + e − → Λ c + Λ ¯ c ( 2625 ) − + c . c . are measured for the first time at center-of-mass energies of s = 4918.0 and 4950.9 MeV. Nonzero cross sections are observed very close to the production threshold. The measured Born cross sections of e + e − → Λ c + Λ ¯ c ( 2625 ) − + c . c . are about 2–3 times greater than those of e + e − → Λ c + Λ ¯ c ( 2595 ) − + c . c . , providing the similar behavior as semileptonic decays of Λ b 0 , but different behavior from that in the hadronic decays of Λ b 0 . The Born cross sections are 15.6 ± 3.1 ± 0.9 pb and 29.4 ± 3.7 ± 2.7 pb for e + e − → Λ c + Λ ¯ c ( 2595 ) − + c . c . , and are 43.4 ± 4.0 ± 4.1 pb and 76.8 ± 6.5 ± 4.2 pb for e + e − → Λ c + Λ ¯ c ( 2625 ) − + c . c . at s = 4918.0 and 4950.9 MeV, respectively. Based on the polar angle distributions of the Λ ¯ c ( 2625 ) − and Λ c ( 2625 ) + , the form-factor ratios | G E | 2 + 3 | G M | 2 / | G C | are determined for e + e − → Λ c + Λ ¯ c ( 2625 ) − + c . c . for the first time, which are 5.95 ± 4.07 ± 0.15 and 0.94 ± 0.32 ± 0.02 at s = 4918.0 and 4950.9 MeV, respectively. All of these first uncertainties are statistical and second systematic. Published by the American Physical Society 2024

Astronomy & Astrophysics↗