Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROWAVE SPECTRUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development of MKIDs for Measurement of the Cosmic Microwave Background with the South Pole Telescope

We present details of the design, simulation, and initial test results of prototype detectors for the fourth-generation receiver of the South Pole Telescope (SPT). Optimized for the detection of key secondary anisotropies of the cosmic microwave background (CMB), SPT-3G+ will measure the temperature and polarization of the mm/sub-mm sky at 220, 285, and 345 GHz, beyond the peak of the CMB blackbody spectrum. The SPT-3G+ focal plane will be populated with microwave kinetic inductance detectors (MKIDs), allowing for significantly increased detector density with reduced cryogenic complexity. We present simulation-backed designs for single-color dual-polarization MKID pixels at each SPT-3G+ observation frequency. We further describe design choices made to promote resonator quality and uniformity, enabling us to maximize the available readout bandwidth. We also discuss aspects of the fabrication process that enable rapid production of these devices and present an initial dark characterization of a series of prototype devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmic birefringence test of the Hubble tension

A cosmic pseudo-Nambu-Goldstone boson has been proposed to resolve the four-sigma discrepancy between precision measurements of the expansion rate of the universe. We show this solution may also produce a cosmic birefringence (CB) signal in the polarization of the cosmic microwave background (CMB); observations of the CB power spectrum and cross-correlation with the CMB can independently confirm the presence of this new boson. In this work, we find significant new contributions to the CB signal, and show that future CMB experiments will greatly improve sensitivity to CB and Hubble tension scenarios.

79 ASTRONOMY AND ASTROPHYSICS↗

Real-world CMB lensing quadratic estimator power spectrum response

I describe a method to estimate response matrices of Cosmic Microwave Background (CMB) lensing power spectra estimators to the true sky power under realistic conditions. Applicable to all lensing reconstruction pipelines based on quadratic estimators (QE), it uses a small number of Gaussian CMB Monte-Carlos and specially designed QE's in order to obtain sufficiently accurate matrices with little computational effort. This method may be used to improve the modelling of CMB lensing band-powers by incorporating at least some of the non-idealities encountered in CMB lensing reconstruction. These non-idealities always include masking, and often inhomogeneous filtering, either in the harmonic domain or pixel space. I obtain these matrices for Planck latest lensing reconstructions, and then show that the residual couplings induced by masking explain very well the residual multiplicative bias seen on the Planck simulations, removing the need for an empirical correction.

79 ASTRONOMY AND ASTROPHYSICS↗

Demonstration of Microwave Cavity Transducer Performance in High Temperature Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment, which is similar to that of an advanced reactor. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Outer diameter of the cylindrical cavity is approximately 3cm, and the thin wall is approximately 200µm thick. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Frequency shift of the cavity spectral response was obtained at room temperature and ambient pressure by gradually increasing water flow rate from 0 to 25GPM (gallons per minute). Corresponding monotonic increase of resonant frequency by several hundred KHz was observed. Next, a sodium flow rate sensing study was performed in a liquid sodium vessel at 340° C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of Microwave Resonant Cavity Transducer Recalibration Procedures

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Inner diameter of the cylindrical cavity is 22.2 mm, and the thin wall is approximately 200µm thick. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Sodium flow rate sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed. From the measurements, we observed significant scatter in high temperature liquid sodium at low flow velocity values. Our hypothesis is that this is caused by temperature drift in the liquid, which results in thermal expansion of the cavity and a drift in the resonator frequency. In this report, we investigate temperature dependence of the resonant frequency through development of analytic models and preliminary analysis of experimental data. In addition, we develop a procedure for compensation for temperature drift during flow sensing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Third Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Gravitational wave spectrum of chain inflation

Chain inflation is an alternative to slow-roll inflation in which the inflaton tunnels along a large number of consecutive minima in its potential. In this work we perform the first comprehensive calculation of the gravitational wave (GW) spectrum of chain inflation. In contrast to slow-roll inflation the latter does not stem from quantum fluctuations of the gravitational field during inflation, but rather from the bubble collisions during the first-order phase transitions associated with vacuum tunneling. Our calculation is performed within an effective theory of chain inflation which builds on an expansion of the tunneling rate capturing most of the available model space. The effective theory can be seen as chain inflation’s analog of the slow-roll expansion in rolling models of inflation. The near scale-invariance of the scalar power spectrum translates to a quasiperiodic shape of the inflaton potential in chain inflation, with the tunneling rate changing very slowly during the e-folds leading to cosmic microwave background observables. We show that chain inflation produces a very characteristic double-peak GW spectrum: a faint high-frequency peak associated with the gravitational radiation emitted during inflation, and a strong low-frequency peak associated with the graceful exit from chain inflation (marking the transition to the radiation-dominated epoch). There exist very exciting prospects to test the gravitational wave signal from chain inflation at the aLIGO-aVIRGO-KAGRA network, at LISA and /or at pulsar timing array experiments. A particularly intriguing possibility we point out is that chain inflation could be the source of the stochastic gravitational wave background recently detected by NANOGrav, PPTA, EPTA, and CPTA. We also show that the gravitational wave signal of chain inflation is often accompanied by running/ higher running of the scalar spectral index to be tested at future cosmic microwave background experiments. Published by the American Physical Society 2024

Freese, Katherine↗

High-accuracy emulators for observables in ΛCDM, N eff, Σ m ν, and w cosmologies

ABSTRACT We use the emulation framework CosmoPower to construct and publicly release neural network emulators of cosmological observables, including the cosmic microwave background (CMB) temperature and polarization power spectra, matter power spectrum, distance-redshift relation, baryon acoustic oscillation (BAO) and redshift-space distortion (RSD) observables, and derived parameters. We train our emulators on Einstein–Boltzmann calculations obtained with high-precision numerical convergence settings, for a wide range of cosmological models including ΛCDM, wCDM, ΛCDM + Neff, and ΛCDM + Σmν. Our CMB emulators are accurate to better than 0.5 per cent out to ℓ = 104, which is sufficient for Stage-IV data analysis, and our P(k) emulators reach the same accuracy level out to $k=50 \, \, \mathrm{Mpc}^{-1}$, which is sufficient for Stage-III data analysis. We release the emulators via an online repository (CosmoPower Organisation), which will be continually updated with additional extended cosmological models. Our emulators accelerate cosmological data analysis by orders of magnitude, enabling cosmological parameter extraction analyses, using current survey data, to be performed on a laptop. We validate our emulators by comparing them to class and camb and by reproducing cosmological parameter constraints derived from Planck TT, TE, EE, and CMB lensing data, as well as from the Atacama Cosmology Telescope Data Release 4 CMB data, Dark Energy Survey Year-1 galaxy lensing and clustering data, and Baryon Oscillation Spectroscopic Survey Data Release 12 BAO and RSD data.

Astronomy & Astrophysics↗

Ultra-narrow-linewidth hybrid-integrated self-injection locked laser at 780 nm

Narrow-linewidth lasers are essential across a wide range of applications, including classical and quantum sensing, trapped ion systems, position/navigation/timing systems, optical clocks, and microwave frequency synthesizers. In the visible and near-visible spectrum, low-noise lasers are particularly important for laser trapping and cooling techniques, which are vital for trapped ion quantum computing, sensing, and atomic clocks. In this context, our work showcases a hybrid-integrated narrow-linewidth laser that operates at 780 nm, achieving a self-heterodyne linewidth of 105 Hz. To validate the experimental results, we performed a numerical analysis that combines insights from a many-body theory applied to the gain region with a travelling-wave model to capture the laser dynamics. Our investigation further delves into how the linewidth of the self-injection locked lasers is influenced by the parameters of micro-ring resonators, aiming to assess the potential for achieving Hz-level integrated laser linewidths at 780 nm. This work not only demonstrates the technical feasibility of Hz-level narrow-linewidth lasers but also lays the groundwork for future explorations in the field.

Prokoshin, Artem (ORCID:0009000699760238)↗

The SPT-3G+ Experiment on the South Pole Telescope

Observations of the cosmic microwave background (CMB) offer an unparalleled opportunity to advance our understanding of fundamental physics. SPT-3G+ is an upgraded receiver for the arcminute-resolution South Pole Telescope (SPT) that plans to deploy in late 2028. SPT-3G+ will increase the CMB mapping speed of SPT by nearly an order of magnitude over the currently installed SPT-3G receiver. SPT-3G+ will have ~24,000 transition-edge sensor (TES) bolometers in two frequency bands with center frequencies at 95 GHz and 150 GHz that will be read out with microwave multiplexing. SPT-3G+ will measure the CMB lensing spectrum and galaxy clusters to constrain the growth of structure, dark matter, and dark energy. SPT-3G+ will also reach critical thresholds on inflationary constraints by combining data with BICEP/Keck, forming the South Pole Observatory (SPO). BICEP/Keck has deep degree-angular scale measurements but is currently delensing-limited, while SPT-3G+ will provide deep lensing measurements. Forecasts show that SPO will reach an uncertainty on the tensor-to-scalar ratio $r$ of $\sigma(r) \sim 1.2\times 10^{-3}$ by 2034. A detection at these levels would provide evidence of inflation and probe new physics at grand unified theory energy scales, while no detection would exclude large classes of models and shift the scientific paradigm describing the early universe. I will give an overview of SPT-3G+ including its design and current status.

Simon, Sara M. [Fermilab] (ORCID:0009000006683584)↗

Light in the dark forest. Part I. An efficient optimal estimator for 3D Lyman-alpha forest power spectrum

The highly anisotropic nature of the Lyman-alpha (Lyα) forest data introduces a complex survey window function that complicates the measurement of the three-dimensional power spectrum ( P 3D ). In this paper, we present the first fully optimal estimator for P 3D , which exactly deconvolves the survey window function and marginalizes contaminated modes that distort the power spectrum. Our approach adapts optimal estimator techniques developed for the 2D cosmic microwave background data to the 3D case. To achieve computational feasibility, we employ the conjugate gradient method and implement the P 3 M formalism to handle large-scale and small-scale operations separately and efficiently. We validate our estimator using Monte Carlo mocks and Gaussian simulations, demonstrating its accuracy and computational efficiency. We confirm that mode marginalization eliminates distortions arising from quasar continuum errors and delivers robust power spectrum estimation, though it also inflates errors at large scales. This first implementation works in the flat-sky case; we discuss the remaining steps needed to generalize it to the curved-sky case. This formalism offers a foundation for the Lyα forest P 3D measurements and a new path toward cosmological constraints from the Lyα forest data.

Lyman alpha forest↗

Forecasting the Ly-𝛼 forest × CMB lensing bispectrum from ACT, SO, S4, and DESI

We forecast the sensitivity of future correlations between cosmic microwave background (CMB) lensing and the Lyman-𝛼 forest power spectrum. This squeezed-limit bispectrum probes the connection between the Lyman-𝛼 transmission and the underlying large-scale matter density field. We recover the measured signal-to-noise (SNR) ratio obtained with Planck × BOSS, and forecast a SNR of 10.3, 14.8 and 20.2 for DESI combined with ACT, SO, and CMB-S4, respectively. For DESI and SO/CMB-S4, the correlation should be detectable at SNR ≥ 5 in 5 redshift bins, useful for distinguishing our signal from several contaminants. Indeed, our forecast is affected by large theoretical uncertainties in the current modeling of the signal and its contaminants, such as continuum misestimation bias or damped-Lyman-𝛼 absorbers. Quantifying these more accurately will be crucial to enable a reliable cosmological interpretation of this observable in future measurements. We attempt to enumerate the features required in future Lyman-𝛼 forest simulations required to do so.

Cosmic microwave background↗

Extragalactic CO emission lines in the CMB experiments: A forgotten signal and a foreground

High resolution cosmic microwave background (CMB) experiments have allowed us to precisely measure the CMB temperature power spectrum down to very small scales (multipole ℓ ~ 3000). Such measurements at multiple frequencies enable separating the power spectrum of the primary CMB anisotropies with the power spectrum of other signals like CMB lensing, thermal and kinematic Sunyaev-Zel’dovich effects (tSZ and kSZ), and cosmic infrared background (CIB). Here, in this paper, we explore another signal of interest at these frequencies that should be present in the CMB maps: extragalactic CO molecular rotational line emissions, which are the most widely used tracers of molecular gas in the line intensity mapping experiments. Using the SIDES simulations adopted for top hat bandpasses at 150 and 220 GHz, we show that the cross-correlation of the CIB with CO lines has a contribution similar to the CIB-tSZ correlation and the kSZ power, thereby contributing a non-negligible amount to the total power at these scales. This signal, therefore, may significantly impact the recently reported ≥3σ detection of the kSZ power spectrum from the South Pole Telescope collaboration, as the contribution of the CO lines is not considered in such analyses. Our results also provide a new way of measuring the CO power spectrum in cross-correlation with the CIB. Finally, these results show that the CO emissions present in the CMB maps will have to be accounted for in all the CMB auto-power spectrum and cross-correlation studies involving a large-scale structure tracer.

79 ASTRONOMY AND ASTROPHYSICS↗

Mitigating foreground bias to the CMB lensing power spectrum for a CMB-HD survey

A promising way to measure the distribution of matter on small scales (k~10 h Mpc –1 ) is to use gravitational lensing of the cosmic microwave background (CMB). CMB-HD, a proposed high-resolution, low-noise millimeter survey over half the sky, can measure the CMB lensing auto spectrum on such small scales enabling measurements that can distinguish between a cold dark matter (CDM) model and alternative models designed to solve problems with CDM on small scales. However, extragalactic foregrounds can bias the CMB lensing auto spectrum if left untreated. Here, we present a foreground mitigation strategy that provides a path to reduce the bias from two of the most dominant foregrounds, the thermal Sunyaev-Zel’dovich effect and the cosmic infrared background. Given the level of realism included in our analysis, we find that the thermal Sunyaev-Zel’dovich alone and the cosmic infrared background alone bias the lensing auto spectrum by 0.6σ and 1.1σ, respectively, in the lensing multipole range of Lϵ[5000,20000] for a CMB-HD survey; combined these foregrounds yield a bias of only 1.3σ. Including these foregrounds, we also find that a CMB-HD survey can distinguish between a CDM model and a 10 –22 eV fuzzy dark matter model at the 5σ level. These results provide an important step in demonstrating that foreground contamination can be sufficiently reduced to enable a robust measurement of the small-scale matter power spectrum with CMB-HD.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dynamical attractors in contracting spacetimes dominated by kinetically coupled scalar fields

We present non-perturbative numerical relativity simulations of slowly contracting spacetimes in which the scalar field driving slow contraction is coupled to a second scalar field through an exponential non-linear σ model-type kinetic interaction. These models are important because they can generate a nearly scale-invariant spectrum of super-Hubble density fluctuations fully consistent with cosmic microwave background observations. We show that the non-linear evolution rapidly approaches a homogeneous, isotropic and flat Friedmann-Robertson-Walker (FRW) geometry for a wide range of inhomogeneous and anisotropic initial conditions. Ultimately, we find, the kinetic coupling causes the evolution to deflect away from flat FRW and towards a novel Kasner-like stationary point, but in general this occurs on time scales that are too long to be observationally relevant.

79 ASTRONOMY AND ASTROPHYSICS↗

Control of spin dynamics in artificial honeycomb spin-ice-based nanodisks

In this paper, we report the experimental and theoretical characterization of the angular-dependent spin dynamics in arrays of ferromagnetic nanodisks arranged on a honeycomb lattice. The magnetic field and microwave frequency dependence, measured by broadband ferromagnetic resonance, reveal a rich spectrum of modes that is strongly affected by the microstate of the network. Based on symmetry arguments with respect to the external field, we show that certain parts of the ferromagnetic network contribute to the detected signal. A comparison of the experimental data with micromagnetic simulations reveals that different subsections of the lattice predominantly contribute to the high-frequency response of the array. This is confirmed by optical characterizations using microfocused Brillouin light scattering. Furthermore, we find indications that nucleation and annihilation of vortexlike magnetization configurations in the low-field range affect the dynamics, which is different from clusters of ferromagnetic nanoellipses. Our work opens up new perspectives for designing magnonic devices that combine geometric frustration in gyrotropic vortex crystals at low frequencies with magnonic crystals at high frequencies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enhanced matter power spectrum from axion kination after Big Bang nucleosynthesis

Despite stringent constraints from Big Bang Nucleosynthesis (BBN) and cosmic microwave background (CMB) observations, it is still possible for well-motivated particle physics models to substantially alter the cosmic expansion history between BBN and recombination. In this work we consider two different axion models that can realize a period of first matter domination, then kination, in this epoch. We perform fits to both primordial element abundances as well as CMB data and determine that up to a decade of late axion domination is allowed by these probes of the early universe. We establish the implications of late axion domination for the matter power spectrum on the scales 1/Mpc ≲ k ≲ 10 3 /Mpc. Our 'log' model predicts a relatively modest bump-like feature together with a small suppression relative to the standard ΛCDM predictions on either side of the enhancement. Our 'two-field' model predicts a larger, plateau-like feature that realizes enhancements to the matter power spectrum of up to two orders of magnitude. These features have interesting implications for structure formation at the forefront of current detection capabilities.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of the temperature and $E$-mode polarization of the cosmic microwave background from the full 500-square-degree SPTpol dataset

Using the full four-year SPTpol 500 deg 2 dataset in both the 95 and 150 GHz frequency bands, we present measurements of the temperature and E-mode polarization of the cosmic microwave background (CMB), as well as the E-mode polarization autopower spectrum (EE) and temperature-E-mode cross-power spectrum (TE) in the angular multipole range 50 < ℓ < 8000. We find the SPTpol dataset to be self-consistent, passing several internal consistency tests based on maps, frequency bands, bandpowers, and cosmological parameters. The full SPTpol dataset is well-fit by the ΛCDM model, for which we find H 0 = 70.48 ± 2.16 km s -1 Mpc -1 and Ω m = 0.271 ± 0.026, when using only the SPTpol data and a Planck-based prior on the optical depth to reionization. The ΛCDM parameter constraints are consistent across the 95 GHz-only, 150 GHz-only, TE-only, and EE-only data splits. Between the ℓ < 1000 and ℓ > 1000 data splits, the ΛCDM parameter constraints are borderline consistent at the ∼2σ level. This consistency improves when including a parameter A L , the degree of lensing of the CMB inferred from the smearing of acoustic peaks. When marginalized over A L , the ΛCDM parameter constraints from SPTpol are consistent with those from Planck. In conclusion, the power spectra presented here are the most sensitive measurements of the lensed CMB damping tail to date for roughly ℓ > 1700 in TE and ℓ > 2000 in EE.

79 ASTRONOMY AND ASTROPHYSICS↗