At least 73 records · Page 4

The mirror and ion cyclotron anisotropy instabilities

The linear dispersion equation for fully electromagnetic waves and instabilities at arbitrary directions of propagation relative to a background magnetic field B(0) in a homogeneous Vlasov plasma is solved numerically for bi-Maxwellian particle distributions. For isotropic plasmas the dispersion and damping of the three modes below the proton cyclotron frequency are studied as functions of Beta(i) and T(e)/T(i). The transport ratios of helicity, cross-helicity, Alfven ratio, compressibility, and parallel compressibility are defined. Under the condition that the proton temperature perpendicular to B(0) is greater than the parallel temperature, the growth rates and transport ratios of the mirror instability and the ion cyclotron anisotropy instability are examined and compared. Both the proton parallel compressibility and the proton Alfven ratio are significantly different for the two growing modes.

Gary, S. P.↗

Crack Branching and Fracture Mirror Data of Glasses and Advanced Ceramics

The fracture mirror and crack branching constants were determined from three glasses and nine advanced ceramics tested under various loading and specimen configurations in an attempt to use the constants as a data base for fractography. The ratios of fracture mirror or crack branching constant to fracture toughness were found to be approximately two for most ceramic materials tested. A demonstration of how to use the two constants as a tool for verifying stress measurements was presented for silicon nitride disk specimens subjected to high-temperature, constant stress-rate biaxial flexure testing.

Choi, Sung R.↗

Precise β branching-ratio measurement for the 0 + → 0 + superallowed decay of 34 Ar

We have measured the branching ratio for the superallowed 0 + → 0 + β transition from 34 Ar to be 0.9448(8), and determined its ft value to be 3058.1(28) s, a result with ±0.09% precision, which is a factor of three improvement over the previous result based on current world data. The ft-value ratio for the mirror pair of superallowed transitions 34 Ar → 34 Cl and 34 Cl → 34 S, becomes the most precise yet measured and, in a sensitive test of the method used to calculate the isospin-symmetry-breaking correction, δ C , it agrees well with the ratio as calculated with Woods-Saxon radial wave functions. This confirms the method used in the most recent survey of superallowed decays to extract V ud , the up-down quark-mixing element of the Cabibbo-Kobayashi-Maskawa matrix. Additionally, our branching-ratio results for the four observed Gamow-Teller branches to 1 + states in 34 Cl are shown to agree well with shell-model calculations based on the same effective interactions that were used in the determination of δ C .

39 ≤ A ≤ 58↗

Asymptotic normalization of mirror states and the effect of couplings

Assuming that the ratio between asymptotic normalization coefficients of mirror states is model independent, charge symmetry can be used to indirectly extract astrophysically relevant proton capture reactions on proton-rich nuclei based on information on stable isotopes. The assumption has been tested for light nuclei within the microscopic cluster model. In this work we explore the Hamiltonian independence of the ratio between asymptotic normalization coefficients of mirror states when deformation and core excitation is introduced in the system. For this purpose we consider a phenomenological rotor+N model where the valence nucleon is subject to a deformed mean field and the core is allowed to excite. We apply the model to {sup 8}Li/{sup 8}B, {sup 13}C/{sup 13}N, {sup 17}O/{sup 17}F, {sup 23}Ne/{sup 23}Al, and {sup 27}Mg/{sup 27}P. Our results show that, for most studied cases, the ratio between asymptotic normalization coefficients of mirror states is independent of the strength and multipolarity of the couplings induced. The exception is for cases in which there is an s-wave coupled to the ground state of the core, the proton system is loosely bound, and the states have large admixture with other configurations. We discuss the implications of our results for novae.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Diamond Machining of an Off-Axis Biconic Aspherical Mirror

Two diamond-machining methods have been developed as part of an effort to design and fabricate an off-axis, biconic ellipsoidal, concave aluminum mirror for an infrared spectrometer at the Kitt Peak National Observatory. Beyond this initial application, the methods can be expected to enable satisfaction of requirements for future instrument mirrors having increasingly complex (including asymmetrical), precise shapes that, heretofore, could not readily be fabricated by diamond machining or, in some cases, could not be fabricated at all. In the initial application, the mirror is prescribed, in terms of Cartesian coordinates x and y, by aperture dimensions of 94 by 76 mm, placements of -2 mm off axis in x and 227 mm off axis in y, an x radius of curvature of 377 mm, a y radius of curvature of 407 mm, an x conic constant of 0.078, and a y conic constant of 0.127. The aspect ratio of the mirror blank is about 6. One common, "diamond machining" process uses single-point diamond turning (SPDT). However, it is impossible to generate the required off-axis, biconic ellipsoidal shape by conventional SPDT because (1) rotational symmetry is an essential element of conventional SPDT and (2) the present off-axis biconic mirror shape lacks rotational symmetry. Following conventional practice, it would be necessary to make this mirror from a glass blank by computer-controlled polishing, which costs more than diamond machining and yields a mirror that is more difficult to mount to a metal bench. One of the two present diamond machining methods involves the use of an SPDT machine equipped with a fast tool servo (FTS). The SPDT machine is programmed to follow the rotationally symmetric asphere that best fits the desired off-axis, biconic ellipsoidal surface. The FTS is actuated in synchronism with the rotation of the SPDT machine to generate the difference between the desired surface and the best-fit rotationally symmetric asphere. In order to minimize the required stroke of the FTS, the blanks were positioned at a large off-axis distance and angle, and the axis of the FTS was not parallel to the axis of the spindle of the SPDT machine. The spindle was rotated at a speed of 120 rpm, and the maximum FTS speed was 8.2 mm/s.

Ohl, Raymond G.↗

High throughput narrowband 83.4 nm self-filtering camera

Photometric imaging of ionospheric/magnetospheric O II emission at 83.4 nm is a primary objective for mapping the distribution of O(+) ions. However, instrumental sensitivity has been a major barrier to realizing this goal. We report an instrumental design employing a low focal ratio three-mirror camera where the reflecting surfaces act as both narrowband reflection filters at 83.4 nm and as a high quality imaging system. The design includes coatings with reflectances that are relatively insensitive to the angle of incidence of light. The peak reflectance per mirror is more than 60 percent at 83.4 nm with the average reflectance for out-of-band wavelengths of less than 5 percent. The net reflective transmission for the three mirrors is greater than 20 percent with 6.8 nm bandwidth and 0.01 percent maximum transmittance for out-of-band wavelengths. The transmittance at 30.4 nm is 0.03 percent at 58.4 nm 0.05 percent, and at 121.6 nm 0.004 percent. When used with an open microchannel plate detector, contamination by H Ly-alpha is essentially eliminated. With this spectral purity and effective elimination of major contributors to background contamination noise, a signal-to-noise ratio (excluding detector noise) of 10 is achievable for a 0.01 R signal in 8.8 seconds for the full 6 deg field-of-view.

Zukic, Muamer↗

Unstable nuclei in dissociation of light stable and radioactive nuclei in nuclear track emulsion

A role of the unstable nuclei {sup 6}Be, {sup 8}Be and {sup 9}B in the dissociation of relativistic nuclei {sup 7,9}Be, {sup 10}B and {sup 10,11}C is under study on the basis of nuclear track emulsion exposed to secondary beams of the JINR Nuclotron. Contribution of the configuration {sup 6}Be + n to the {sup 7}Be nucleus structure is 8 ± 1% which is near the value for the configuration {sup 6}Li + p. Distributions over the opening angle of α-particle pairs indicate to a simultaneous presence of virtual {sup 8}Be{sub g.s}. and {sup 8}Be{sub 2+} states in the ground states of the {sup 9}Be and {sup 10}C nuclei. The core {sup 9}B is manifested in the {sup 10}C nucleus with a probability of 30 ± 4%. Selection of the {sup 10}C “white” stars accompanied by {sup 8}Be{sub g.s}. ({sup 9}B) leads to appearance in the excitation energy distribution of 2α2p “quartets” of the distinct peak with a maximum at 4.1 ± 0.3 MeV. {sup 8}Be{sub g.s}. decays are presented in 24 ± 7% of 2He + 2H events of the {sup 11}C coherent dissociation and 27 ± 11% of the 3He ones. The channel {sup 9}B + H amounts 14 ± 3%. The {sup 8}B{sub g.s}. nucleus is manifested in the coherent dissociation {sup 10}B → 2He + H with a probability of 25 ± 5% including 13 ± 3% of {sup 9}B decays. A probability ratio of the mirror channels {sup 9}B + n and {sup 9}Be + p is estimated to be 10 ± 1.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Indentation flaw formation and strength response of silicon nitride ceramics at low indentation loads

The configuration and the strength response of indentation flaws in silicon nitrides are described as a function of indentation loads primarily near the threshold level. Test materials under consideration include 30 vol percent SiC whisker-reinforced composite silicon nitride and similar monolithic silicon nitride. The results of strength testing show that, at indentation loads less than or equal to 1.96, a number of the specimens fail from the intrinsic flaws of the materials rather than from the indent sites, causing a distinct trend to reach a plateau, at a level corresponding to the as-received strength of the material. The ratio of the mirror constant to the fracture toughness for the composite and monolithic materials is found to be 1.44 and 1.51, respectively.

Choi, Sung R.↗

Streak-Camera Measurements with High Currents in PEP-II and Variable Optics in SPEAR3

A dual-axis, synchroscan streak camera was used to measure longitudinal bunch profiles in three storage rings at SLAC: the PEP-II low- and high-energy rings, and SPEAR3. At high currents, both PEP rings exhibit a transient synchronous-phase shift along the bunch train due to RF-cavity beam loading. Bunch length and profile asymmetry were measured along the train for a range of beam currents. To avoid the noise inherent in a dual-axis sweep, we accumulated single-axis synchroscan images while applying a 50-ns gate to the microchannel plate. To improve the extinction ratio, an upstream mirror pivoting at 1 kHz was synchronized with the 2kHz MCP gate to deflect light from other bunches off the photocathode. Bunch length was also measured on the HER as a function of beam energy. For SPEAR3 we measured bunch length as a function of single-bunch current for several lattices: achromatic, low-emittance and low momentum compaction. In the first two cases, resistive and reactive impedance components can be extracted from the longitudinal bunch profiles. In the low-alpha configurations, we observed natural bunch lengths approaching the camera resolution, requiring special care to remove instrumental effects, and saw evidence of periodic bursting.

43 PARTICLE ACCELERATORS↗

MHD plasma stabilization in a chain of axisymmetric adiabatic open mirror cells

Conditions for convective plasma instability in a chain of axisymmetric adiabatic mirror cells with different signs of magnetic field curvature are analyzed. The boundaries of the region that can be occupied by a stable hollow plasma in a system of two connected cells-a nonparaxial simple mirror cell and a semicusp-are determined, as well as the interval of allowed values of the ratio between the pressures in the cells. Because of the large magnetic field curvature in the component cells, the safety factor that is achieved at both-external and internal-plasma boundaries in accordance with the average min-B principle can be high. It is assumed that the unperturbed pressure in each cell is almost isotropic, in which case the mirror ratio should necessarily be large. A key role in the stability of the plasma is played by its compressibility. A comparison is made between the conditions for complete plasma stabilization against arbitrary perturbations and the conditions for stability of individual cells against the global mode. The stability of the cells against the global mode is sufficient, but not necessary, for stabilizing the chain. The analysis is done by using orthogonal coordinates associated with the unperturbed magnetic field (flux variables). Numerical simulations were carried out for nonparaxial cells from a certain three-parameter family.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of optical mirror structures

The structural requirements for large optical telescope mirrors was studied with a particular emphasis placed on the three-meter Large Space Telescope primary mirror. Analysis approaches through finite element methods were evaluated with the testing and verification of a number of element types suitable for particular mirror loadings and configurations. The environmental conditions that a mirror will experience were defined and a candidate list of suitable mirror materials with their properties compiled. The relation of the mirror mechanical behavior to the optical performance is discussed and a number of suitable design criteria are proposed and implemented. A general outline of a systematic method to obtain the best structure for the three-meter diffraction-limited system is outlined. Finite element programs, using the STRUDL 2 analysis system, were written for specific mirror structures encompassing all types of active and passive mirror designs. Parametric studies on support locations, effects of shear deformation, diameter to thickness ratios, lightweight and sandwich mirror configurations, and thin shell active mirror needs were performed.

Soosaar, K.↗

PSD Determination using a Simultaneous-Phase Acquisition Interferometer for the Constellation-X Spectroscopy X-ray Telescope (SXT) Mirrors

We investigated the use of a simultaneous-phase acquisition interferometer (a 4D FizCamTM 1500) for determining the PSD of the extremely-high aspect ratio (500: 1) glass mirrors for the Constellation-X SXT telescope. We found that the results obtained are strongly influenced by the methodology employed while collecting the data and outline a best method for this type of measurement.

Lehan, J. P.↗

A comparison of performance of lightweight mirrors

Four lightweight solid contoured back mirror shapes (a double arch, a single arch, a modified single arch, and a double concave mirror) and a cellular sandwich lightweight meniscus mirror, have been considered for the primary mirror of the Space Infrared Telescope Facility (SIRTF). A parametric design study using these shapes for the SIRTF 40 inch primary mirror with a focal ratio f/2 is presented. Evaluations of the optical performance and fundamental frequency analyses are performed to compare relative merits of each mirror configuration. Included in these are structural, optical, and frequency analyses for (1) different back contour shapes, (2) different number and location of the support points, and (3) two gravity orientations (ZENITH and HORIZON positions). The finite element program NASTRAN is used to obtain the structural deflections of the optical surface. For wavefront error analysis, FRINGE and PCFRINGE programs are used to evaluate the optical performance. A scaling law relating the optical and structural performance for various mirror contoured back shapes is developed.

Cho, Myung K.↗

Design, Fabrication, Optical Testing, and Performance of Diamond Machined Aspheric Mirrors for Ground-Based Near-IR Astronomy

Challenges in fabrication and testing have historically limited the choice of surfaces available for the design of reflective optical instruments. Spherical and conic mirrors are common, but, for future science instruments, more degrees of freedom are necessary to meet challenging performance and packaging requirements. These instruments will be composed of unusual aspheres located far off-axis with large spherical departure, and some designs will require asymmetric surface profiles. In particular, single-surface astigmatism correction in spectrographs necessitates a toroidal surface, which lacks an axis of rotational symmetry. We describe the design, fabrication, optical testing, and performance of three rotationally symmetric, off-axis, aspheric mirrors and one toroidal, off-axis, biconic camera mirror on aluminum substrates for the Infrared Multi-Object Spectrograph (IRMOS) instrument. IRMOS is a facility instrument for the Kitt Peak National Observatory's Mayall Telescope (3.8 m) and an engineering prototype for a possible design of the Next Generation Space Telescope/Multi-Object Spectrograph. The symmetric mirrors range in aperture from 94x86 mm to 286x269 mm and in f-number from 0.9 to 2.4. They are various off-axis, convex and concave, prolate and oblate ellipsoids. The concave biconic mirror has a 94x76 mm aperture, Rx=377 mm, kx=0.0778, Ry=407 mm, and ky=0.1265 and is decentered. by -2 mm in x and 227 mm in y. The mirrors have an aspect ratio of approximately 4:1. The surface error fabrication tolerances are less than 63.3 nm RMS figure error and less than 10 nm RMS microroughness. The mirrors are attached to the instrument bench via a semi-kinematic, integral flexure mount. We describe mirror design, diamond machining, the results of figure testing using computer-generated holograms, and imaging and scattered light modeling and performance.

Ohl, Raymond G.↗

Precise branching ratio measurement for the superallowed β+ decay of 26 Si: Completion of a second mirror pair

As part of a continuing effort to test the unitarity of the Cabbibo-Kobayashi-Maskawa matrix, we have measured the branching ratio for the superallowed 0 + → 0 + β + -decay transition from 26 Si to be 0.7569(14), a result with 0.18% relative precision. With this result, the ft value for the transition is now established with comparable precision to the well-known superallowed transitions currently used in the determination of V ud . Furthermore, it also completes a second pair of mirror superallowed transitions, 26 Si → 26m Al and 26m Al → 26 Mg, the ratio of whose measured ft values provides a sensitive test of the method used to calculate the isospin-symmetry-breaking correction δ C needed to determine V ud . Like the previously measured ratio for the mass-38 mirror pair, the new result agrees well with the calculation based on Woods-Saxon radial wave functions and strengthens the case for rejecting the calculation that uses Hartree-Fock radial functions.

20 ≤ A ≤ 38↗

Extended range X-ray telescope: X-ray microscope design

A glancing incidence X-ray microscope using a confocal hyperboloid ellipsoid mirror was designed to couple optically a Wolter 1 telescope to a CCD focal plane detector. Both the RMS spot size and the point spread function calculations were used to evaluate the resolution, defocusing, and vignetting effects of the system for microscope focal lengths of 1, 1.5, and 2 meters and for magnifications varying from 2 to 10x. For the specific application with the S-056 telescope, a 2 meter, 8x microscope with a fabrication ratio of the microscope mirror length to the inner diameter at hyperboloid ellipsoid intersection of 2.5 was designed to be used with a thinned, back illuminated CCD detector array with 320 by 512, 30 micron pixels.

Shealy, D. L.↗

Optical Testing of Diamond Machined, Aspheric Mirrors for Groundbased, Near-IR Astronomy

The Infrared Multi-Object Spectrometer (IRMOS) is a facility-class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8-2.5 micron) spectrometer and operates at approximately 80 K. The 6061-T651 aluminum bench and mirrors constitute an athermal design. The instrument produces simultaneous spectra at low- to mid-resolving power (R=lambda/delta lambda= 300-3000) of approximately 100 objects in its 2.8 x 2.0 arcmin field. We describe ambient and cryogenic optical testing of the IRMOS mirrors across a broad range in spatial frequency (figure error, mid-frequency error, and microroughness). The mirrors include three rotationally symmetric, off-axis conic sections, one off-axis biconic, and several flat fold mirrors. The symmetric mirrors include convex and concave prolate and oblate ellipsoids. They range in aperture from 94x86 mm to 286x269 mm and in f-number from 0.9 to 2.4. The biconic mirror is concave and has a 94x76 mm aperture, R(sub x)=377 mm, k(sub x)=0.0778, R(sub y)=407 mm, and k(sub y)=0.1265 and is decentered by -2 mm in X and 227 mm in Y. All of the mirrors have an aspect ratio of approximately 6:1. The surface error fabrication tolerances are less than 10 nm RMS microroughness, 'best effort' for mid-frequency error, and less than 63.3 nm RMS figure error. Ambient temperature (approximately 293 K) testing is performed for each of the three surface error regimes, and figure testing is also performed at approximately 80 K. Operation of the ADE Phaseshift MicroXAM white light interferometer (micro-roughness) and the Bauer Model 200 profilometer (mid-frequency error) is described. Both the sag and conic values of the aspheric mirrors make these tests challenging. Figure testing is performed using a Zygo GPI interferometer, custom computer generated holograms (CGH), and optomechanical alignment fiducials. Cryogenic CGH null testing is discussed in detail. We discuss complications such as the change in prescription with temperature and thermal gradients. Correction for the effect of the dewar window is also covered. We discuss the error budget for the optical test and alignment procedure. Data reduction is accomplished using commercial optical design and data analysis software packages. Results from CGH testing at cryogenic temperatures are encouraging thus far.

Chambers, V. John↗