Electronic-to-vibrational energy transfer efficiency in the O/1 D/-N2 and O/1 D/-CO systems

With the aid of a molecular resonance fluorescence technique, which utilizes optical pumping from the v = 1 level of the ground state of CO by A 1 Pi-X 1 Sigma radiation, a study is made of the efficiency of E-V transfer from O(1 D) to CO. O(1 D) is generated at a known rate by O2 photodissociation at 1470 A in an intermittent mode, and the small modulation of the fluorescent signal associated with CO (v = 1) above the normal thermal background is interpreted in terms of E-V transfer efficiency. The CO (v = 1) lifetime in this system is determined mainly by resonance trapping of the IR fundamental band, and is found to be up to ten times longer than the natural radiative lifetime. For CO, (40 plus or minus 8)% of the O(1 D) energy is converted into vibrational energy. By observing the effect of N2 on the CO (v = 1) fluorescent intensity and lifetime, it is possible to obtain the E-V transfer efficiency for the system O(1 D)-N2 relative to that for O(1 D)-CO. The results indicate that the efficiency for N2 is (83 plus or minus 10)% of that for CO.

Slanger, T. G.↗

IR pumped third-harmonic generation and sum-frequency generation in diatomic molecules

The potential efficiency of using nonlinear up-conversion techniques for the high efficiency type lasers (CO,CO2, and chemical) is assessed. Results indicate that: the small pump photon energy necessitates the use of molecular media for conversion if resonance enhancement is to be used and that molecular systems present several problems. These difficulties include: their levels are complex; their transition probabilities are often unknown; and the oscillator strengths among vibrational levels in the ground electronic state of a molecule are much smaller than those among electronic states of an atom, thus limiting the magnitude of nonlinear interactions. It is shown that this problem can be eliminated by making use of vibronic transitions which, being primarily electronic transitions have much larger matrix elements and efficient conversion can be achieved with molecular systems.

She, C. Y.↗

Further laboratory studies and stratospheric flight of a mass spectrometer beam system

A gas expansion system combined with a mass spectrometer has been tested and flown successfully in the stratosphere. Through a sequence of orifices and high speed pumping, gas particles were formed into a molecular beam and analyzed by a sensitive mass spectrometer. During two balloon flights, vertical profiles of all major atmospheric constituents as well as O3, CO2, H2O and others were obtained. Gases such as AR38 and O16;O17 provided in-flight calibration standards. The sensitivity of the system was such that gases with mixing ratios of 10 ppb at an ambient pressure of about 10 mbar were detectable.

Mauersberger, K.↗

Water maser emission from X-ray-heated circumnuclear gas in active galaxies

We have modeled the physical and chemical conditions present within dense circumnuclear gas that is irradiated by X-rays from an active galactic nucleus. Over a wide range of X-ray fluxes and gas pressures, the effects of X-ray heating give rise to a molecular layer at temperatures of 400-1000 K within which the water abundance is large. The physical conditions within this molecular layer naturally give rise to collisionally pumped maser emission in the 6(sub 16) - 5(sub 23) 22 GHz transition of ortho-water, with predicted maser luminosities of 10(exp 2 +/- 0.5) solar luminosity per sq. pc of illuminated area. Given plausible assumptions about the geometry of the source and about the degree to which the maser emission is anisotropic, such surface luminosities are sufficient to explain the large apparent luminosities observed in water maser sources that are associated with active galactic nuclei.

Neufeld, David A.↗

Compact hydrogenator

The development and characteristics of a hydrogenating apparatus are described. The device consists of a reaction chamber which is selectively permeable to atomic hydrogen and catalytically active to a hydrogenating reaction. In one device, hydrogen is pumped out of the reaction chamber while the reactant remains inside to remove molecular hydrogen so that more atomic hydrogen can pass through the walls. In another device, the reactant is pumped through the reaction chamber, and the hydrogen is removed from the material leaving the chamber. The reactant is then cycled through the chamber.

Simmonds, P. G.↗

Lasant Materials for Blackbody-Pumped Lasers

Blackbody-pumped solar lasers are proposed to convert sunlight into laser power to provide future space power and propulsion needs. There are two classes of blackbody-pumped lasers. The direct cavity-pumped system in which the lasant molecule is vibrationally excited by the absorption of blackbody radiation and laser, all within the blackbody cavity. The other system is the transfer blackbody-pumped laser in which an absorbing molecule is first excited within the blackbody cavity, then transferred into a laser cavity when an appropriate lasant molecule is mixed. Collisional transfer of vibrational excitation from the absorbing to the lasing molecule results in laser emission. A workshop was held at NASA Langley Research Center to investigate new lasant materials for both of these blackbody systems. Emphasis was placed on the physics of molecular systems which would be appropriate for blackbody-pumped lasers.

Deyoung, R. J.↗

Molecular contamination study by interaction of a molecular beam with a platinum surface

The capability of molecular beam scattering from a solid surface is analyzed for identification of molecular contamination of the surface. The design and setup of the molecular beam source and the measuring setup for the application of a phase sensitive measuring technique for the determination of the scattered beam intensity are described. The scattering distributions of helium and nitrogen molecular beams interacting with a platinum surface were measured for different amounts of contamination from diffusion pump oil for surface temperatures ranging from 30 to 400 C. The results indicate the scattering of molecular beams from a platinum surface is a very sensitive method for detecting surface contamination.

Nuss, H. E.↗

Generation of Optical Combs in a WGM Resonator from a Bichromatic Pump

Optical combs generated by a monolithic resonator with Kerrmedium can be used in a number of applications, including orbital clocks and frequency standards of extremely high accuracy, such as astronomy, molecular spectroscopy, and the like. The main difficulty of this approach is the relatively high pump power that has to be used in such devices, causing undesired thermorefractive effects, as well as stimulated Raman scattering, and limiting the optical comb quality and utility. In order to overcome this problem, this innovation uses a different approach to excitation of the nonlinear oscillations in a Kerr-nonlinear whispering gallery mode (WGM) resonator and generation of the optical comb. By coupling to the resonator two optical pump frequencies instead of just one, the efficiency of the comb source can be increased considerably. It therefore can operate in a lowerpower regime where the undesirable effects are not present. This process does not have a power threshold; therefore, the new optical component can easily be made strong enough to generate further components, making the optical comb spread in a cascade fashion. Additionally, the comb spacing can be made in an arbitrary number of the resonator free spectral ranges (FSR). The experimental setup for this innovation used a fluorite resonator with OMEGA= 13.56 GHz. This material has very low dispersion at the wavelength of 1.5 microns, so the resonator spectrum around this wavelength is highly equidistant. Light was coupled in and out of the resonator using two optical fibers polished at the optimal coupling angle. The gap between the resonator and the fibers, affecting the light coupling and the resonator loading, was controlled by piezo positioners. The light from the input fiber that did not go into the resonator reflected off of its rim, and was collected by a photodetector. This enabled observation and measurement of the (absorption) spectrum of the resonator. The input fiber combined light from two lasers centered at around 1,560 nanometers. Both laser frequencies were simultaneously scanned around the selected WGMs of the same family. However, they were separated by one, two, three, or ten FSRs. This was achieved by fine-tuning each laser frequency offset until the selected resonances overlap on the oscilloscope screen. The resonator quality factor Q = 7 x 10(exp 7) was relatively low to increase the linewidth and, therefore, the duty cycle of both lasers simultaneously coupled into their WGMs. The optical spectrum analyzer (OSA) connected to the output fiber was continuously acquiring data, asynchronously with the laser scan. The instrument was set to retain the peak power values; therefore, a trace recorded for a sufficiently long period of time reflected the situation with both lasers maximally coupled to the WGMs.

Strekalov, Dmitry V.↗

A mass spectrometer-beam experiment for investigations of planetary atmospheres

An experimental concept for investigation of planetary atmospheres using a mass spectrometer is discussed. High atmospheric pressures are reduced to mass spectrometer operating pressures by means of differential pumping. Sampling is accomplished through the formation of a molecular beam. A flag in front of the mass spectrometer can be used to separate ambient gases from system background. Laboratory tests have confirmed the feasibility of the experiment, particularly in CO2 dominated atmospheres.

Mauersberger, K.↗

Infrared-pumped third-harmonic and sum-frequency generation in diatomic molecules

Using molecular hydrogen as a model system, we present a calculation which demonstrates the feasibility of efficient third-harmonic and sum-frequency generation of IR laser radiation by diatomic molecular gases. A conversion efficiency of 10% without phase matching is achievable with a modest laser intensity of about 20 MW/sq cm. In addition to a two-photon resonance, the efficient conversion depends on a mechanism which makes use of virtual vibronic transitions exclusively. Possible methods for phase matching are also suggested.

She, C. Y.↗

The High Spectral Resolution Lidar

The High Spectral Resolution Lidar (HSRL) system was developed for the remote measurement of atmospheric optical properties. Measurements are obtained by the separation of the backscattered signal into aerosol and molecular channels using a high spectral resolution Fabry-Perot optical interferometer to separate the aerosol contributions to backscatter near the laser wavelength from the Doppler-shifted molecular component of the backscatter. The transmitter consists of an optically pumped pulsed dye laser of the oscillator-amplifier design which emits at 467.88 nm, with a bandwidth of less than 0.3 pm. The transmitter and receiver share a common Schmidt-Cassegrain telescope, although they do not share the same field stop, but rather two conjugate stops. The HSRL system uses a computer-controlled dual-channel photon-counting data acquisition system providing for stable measurements at very low power levels and an excellent dynamic range. The system has been used to obtain airborne measurements of height profiles of aerosol and molecular backscatter cross sections.

Eloranta, E. W.↗

Nuclear-pumped He/3/-Ar laser modeling

A first-order model of He(3)-Ar 1.79-micron laser is developed, compared to experimental results, and used to explain the qualitative features of this system. Results indicate that direct excitation of the argon upper level is at best very inefficient for population inversion. For argon concentrations which give the most efficient laser operation, the He-3(n,p)He-3(n,p)He-3 energy is used to produce atomic He ions that quickly convert into He molecular ions. These molecular ions subsequently form argon atomic ions through charge transfer. The dominant pumping mechanism is collisional-radiative recombination of the argon atomic ion and subsequent radiative cascading into the upper laser level.

Wilson, J. W.↗

Temperature Swing Adsorption Compressor Development

Closing the oxygen loop in an air revitalization system based on four-bed molecular sieve and Sabatier reactor technology requires a vacuum pump-compressor that can take the low-pressure CO, from the 4BMS and compress and store for use by a Sabatier reactor. NASA Ames Research Center proposed a solid-state temperature-swing adsorption (TSA) compressor that appears to meet performance requirements, be quiet and reliable, and consume less power than a comparable mechanical compressor/accumulator combination. Under this task, TSA compressor technology is being advanced through development of a complete prototype system. A liquid-cooled TSA compressor has been partially tested, and the rest of the system is being fabricated. An air-cooled TSA compressor is also being designed.

Finn, John E.↗

Diversity and regulation of plant Ca2+ pumps: insights from expression in yeast

The spatial and temporal regulation of calcium concentration in plant cells depends on the coordinate activities of channels and active transporters located on different organelles and membranes. Several Ca2+ pumps have been identified and characterized by functional expression of plant genes in a yeast mutant (K616). This expression system has opened the way to a genetic and biochemical characterization of the regulatory and catalytic features of diverse Ca2+ pumps. Plant Ca(2+)-ATPases fall into two major types: AtECA1 represents one of four or more members of the type IIA (ER-type) Ca(2+)-ATPases in Arabidopsis, and AtACA2 is one of seven or more members of the type IIB (PM-type) Ca(2+)-ATPases that are regulated by a novel amino terminal domain. Type IIB pumps are widely distributed on membranes, including the PM (plasma membrane), vacuole, and ER (endoplasmic reticulum). The regulatory domain serves multiple functions, including autoinhibition, calmodulin binding, and sites for modification by phosphorylation. This domain, however, is considerably diverse among several type IIB ATPases, suggesting that the pumps are differentially regulated. Understanding of Ca2+ transporters at the molecular level is providing insights into their roles in signaling networks and in regulating fundamental processes of cell biology.

Review, Academic↗

Approximate analytic solutions for the optical pumping of fluorescent dyes

A general technique for solving a system of rate equations describing the interaction of an electromagnetic field and a molecular system is presented. The method is used to obtain approximate time-dependent solutions for the upper-level population of fluorescent dyes in the presence of a pump field.

Lawandy, N. M.↗

Approximate analytic solutions for the optical pumping of fluorescent dyes

A general technique for solving a system of rate equations describing the interaction of an electromagnetic field and a molecular system is presented. The method is used to obtain approximate time-dependent solutions for the upper-level populations of fluorescent dyes in the presence of a pump field.

Lawandy, N. M.↗

Vacuum-ultraviolet laser uses superfluid helium

Vacuum ultra violet laser in wavelength around 0.800 microns is produced by using optical pumping to increase lifetimes of excited metastable molecules in super fluid helium. In method, super fluid helium is pumped electronically to produce excited HE2, and then pumped by circularly polarized 0.9096 - micron radiation to aline excited HE2 molecular spins. High power ultraviolet radiation has potential applications in molecular reaction studies, power transmission in space, and biomedical research.

Zmuidzinas, J. S.↗