Search NASA⌕ Search

SEARCH · Search NASA

Results for “Magnetic Resonance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Further modeling of q 95 windows for the suppression of edge localized modes by resonant magnetic perturbations in the DIII-D tokamak

An improved resonant plasma response model that more accurately captures the physics of the interaction between a tokamak plasma and a resonant magnetic perturbation (RMP) is developed. The model interpolates between the linear and the nonlinear response regimes and takes into account the fact that the slip-frequency is non-zero in the nonlinear regime. The improved model is incorporated into the extended perturbed equilibrium code (EPEC) toroidal asymptotic matching code. The modified EPEC code is used to investigate RMP-induced edge-localized-mode (ELM) suppression in DIII-D H-mode discharge #145380. Somewhat surprisingly, allowing for a finite slip-frequency (i.e., relaxing the so-called no-slip constraint) is found to only slightly facilitate the locking of driven magnetic island chains to the RMP, and, hence, to only slightly facilitate RMP-induced ELM suppression. This is true despite the fact that the nature of non-locked island solutions is radically different when the no-slip constraint is imposed compared to when it is relaxed (in the first case, the widths of the island chains driven at the rational surfaces pulsate, and in the second case, they remain steady). The previously obtained conclusion that the response of a typical H-mode tokamak plasma to an RMP cannot be accurately modeled by linear theory is confirmed. Here, the previously obtained conclusion that the best agreement between theory and observations is achieved by assuming that the natural frequencies of tearing modes, in the absence of the RMP, are determined by the local equilibrium E × B velocity is also confirmed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-linear MHD modelling of edge localized modes suppression by resonant magnetic perturbations in ITER

Edge localized modes (ELMs) suppression by resonant magnetic perturbations (RMPs) was studied with the non-linear magneto-hydro-dynamic (MHD) code JOREK for the ITER H-mode scenarios at 15 MA, 12.5 MA, 10 MA/5.3 T. In this study, the main aim was to demonstrate that ELMs can be suppressed by RMPs while the divertor 3D footprints of heat and particle fluxes remain within divertor material limits. The unstable peeling–ballooning modes responsible for ELMs without RMPs were modelled first for each scenario using numerically accessible parameters for ITER. Then the stabilization of ELMs by RMPs was modelled with the same parameters. RMP spectra, optimized by the linear MHD MARS-F code, with main toroidal harmonics N = 2, N = 3, N = 4 have been used as boundary conditions of the computational domain of JOREK, including realistic RMP coils, main plasma, scrape off layer (SOL) divertor and realistic first wall. The model includes all relevant plasma flows: toroidal rotation, two fluid diamagnetic effects and neoclassical poloidal friction. With RMPs, the main toroidal harmonic and the non-linearly coupled harmonics remain dominant at the plasma edge, producing saturated modes and a continuous MHD turbulent transport thereby avoiding ELM crashes in all scenarios considered here. The threshold for ELM suppression was found at a maximum RMP coils current of 45 kAt–60 kAt compared to the coils maximum capability of 90 kAt. In the high beta poloidal steady-state 10 MA/5.3 T scenario, a rotating QH-mode without ELMs was observed even without RMPs. In this scenario with RMPs N = 3, N = 4 at 20 kAt maximum current in RMP coils, similar QH-mode behaviour was observed however with dominant edge harmonic corresponding to the main toroidal number of RMPs. The present MHD modelling was limited in time by few tens of ms after RMPs were switched on until the magnetic energy of the modes saturates. As a consequence the thermal energy was still evolving on this time scale, far from the ITER confinement time scale and hence only the form of 3D footprints on the divertor targets can be indicated within this set-up. Also note, that the divertor physics was missing in this model, so realistic values of fluxes are out of reach in this modelling. However the stationary 3D divertor and particle fluxes could be simply extrapolated from these results to the stationary situation considering that a large power fraction should be radiated in the core and SOL and only about 50 MW power is going to the divertor, which is an arbitrary, but reasonable number used here. The 3D footprints with RMPs show the characteristic splitting with the main RMP toroidal symmetry. The maximum radial extension of the footprints typically was ~20 cm in inner divertor and ~40 cm in outer divertor with stationary heat fluxes decreasing further out from the initial strike point from ~5 MW m ₋2 to ~1 MW m ₋2 assuming a total power in the divertor and walls is 50 MW. The heat fluxes remain within the divertor target and baffle areas, however with rather small margin in the outer divertor which could be an issue for the first wall especially in transient regimes when part of the plasma thermal energy is released due to switching on the RMP coils. This fact should be considered when RMPs are applied with a more favorable application before or soon after the L–H transition, although optimization is required to avoid increasing the L–H power threshold with RMPs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of the Magnetic Resonance Capabilities at INL

The aim of this presentation is to give a broad overview of the magnetic resonance capabilities at Idaho National Laboratory and how the technique is implemented within the different directorates at the lab. Historically, the high-field NMR instrumentation has been used by our Energy & Environment Science and Technology (EES&T) directorate primarily as a characterization tool for synthetic chemistry work, but we have been actively trying to expand the use of the instrumentation into our Nuclear Science and Technology (NS&T) and National and Homeland Security (NHS) directorates. The expanded scope of work has ranged from solid-state characterization of biomass, analysis of electrolyte materials from lithium ion batteries, quantification of extracted critical materials, and measurement of metal-ligand complexes using ligands proposed for use in the nuclear fuel cycle.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Reynolds stress tensor measurements using magnetic resonance velocimetry: expansion of the dynamic measurement range and analysis of systematic measurement errors

This study presents magnetic resonance velocimetry (MRV) Reynolds Stress measurements in a periodic hill channel with a hill Reynolds number of Re = 29,500. The velocity encoding scheme is based on the ICOSA6 method with six icosahedral encoding directions and multiple encoding values are measured to increase the dynamic range. The full Reynolds stress tensor is obtained from a voxel-wise three-dimensional Gaussian fit using the magnitude data of all acquisitions. The MRV results are compared to a wall-resolved large eddy simulation and laser Doppler velocimetry measurements conducted in the same channel. It is shown that the MRV Reynolds stress data have excellent precision and agree qualitatively with the reference data. However, there are apparent systematic deviations. One of the most prominent error contributions is the signal attenuation caused by higher orders of motion, which leads to an overestimation of the turbulence level. Another fundamental error is identified in the assumption that the turbulence is Gaussian distributed. With the presented reconstruction technique, the MRV data are fitted to a statistical model, and depending on the examined flow setup, the Gaussian model can lead to considerable errors. Possible ways of how to reduce all identified errors are presented. In summary, this technique enables Reynolds stress tensor measurements in complex internal flows with high dynamic range and excellent precision. However, several issues need to be resolved to make the turbulence quantification more accurate.

42 ENGINEERING↗

Design and demonstration of a low‐field magnetic resonance imaging rhizotron for in‐field imaging of energy sorghum roots

Abstract Root phenotyping provides critical information to plant breeders for developing varieties with improved drought tolerance, greater root biomass, and greater nutrient use efficiency. Phenotyping roots in the natural environment is important for understanding the effect of the soil environment on root genotypic expressions. The goal of this work was to design and test a field‐scale mobile low‐field magnetic resonance imaging (LF‐MRI) Rhizotron that produces actionable root phenotyping data. We demonstrated this novel technology for root visualization and quantification using a LF‐MRI Rhizotron operating at 47 mT with two soil types. The LF‐MRI Rhizotron weights 453 kg, with a height of 90 cm, a diameter of 28 cm and an imaging field of view of 28 cm × 28 cm. The unit was operated in a Belk clay (Entic Hapluderts) and Weswood silt loam (Udifluventic Halustepts) generating 2‐D and 3‐D image data sets. The 2‐D image data had a collection time of 16.5 min per image at an image resolution of 2.2 mm per pixel. The 3‐D data had a collection time of 13 h per image with a 2.2 × 2.2 × 2.2 mm voxel resolution. Low‐field magnetic resonance imaging worked well for visualizing roots in moderate to high clay soils, demonstrating the potential for this technology; however, the broad application of this platform is hampered due to the prohibitively long scanning time to obtain 3‐D images. By increasing the field strength, and therefore the signal‐to‐noise ratio, faster scan times can enable a more useful system for root phenotyping.

Bagnall, G. Cody↗

Metrics and extrapolation of resonant magnetic perturbation thresholds for ELM suppression

This large database study of resonant magnetic perturbation (RMP) edge localized mode (ELM) suppression thresholds in the AUG, DIII-D, EAST, and KSTAR tokamaks details the key strengths and weaknesses of RMP metrics. The RMP ELM suppression database used for this work contains plasma information at the time of transition from ELMing to ELM suppressed states where a clear experimental threshold is identified. The experimental threshold distributions are compared for five metrics: (1) the island overlap width, (2) pedestal top Chirikov overlap, (3) peeling edge displacement, (4) pedestal top resonant drive, and (5) edge dominant mode overlap. The distributions, the regularity of the dependence on RMP coil currents, and the sensitivities of a given metric to equilibrium reconstruction details are compared. The overlap metric proves to be a good compromise between including the appropriate plasma response physics and maintaining a numerical robustness. This quantity does not exhibit clear power-law scalings for projection, but machine learning can assist in predicting thresholds within the existing parameter ranges and providing uncertainty quantification of those predictions. Two new first-principles models, one utilizing a threshold from the non-linear Modified Rutherford equation evaluated at the pedestal top and one utilizing the SLAYER code to calculate the linear tearing threshold from torque balance, offer possible paths to extrapolation beyond the existing database parameter space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear magnetic resonance investigation of superconducting and normal state Nb 3 Sn

The superconductor Nb3Sn has important applications for construction of very high-field superconducting magnets. In this work we investigate its microscopic electronic structure with 93 Nb nuclear magnetic resonance (NMR). The high-quality Nb 3 Sn powder sample was studied in both 3.2 T and 7 T magnetic fields in the temperature range from 4 K to 300 K. From measurement of the spectrum and its theoretical analysis, we find evidence for anisotropy despite its cubic crystal structure. Magnetic alignment of the powder grains in the superconducting state was also observed. The Knight shift and spin-lattice relaxation rate, T 1 -1 , were measured and the latter compared with BCS theory for the energy gap Δ(0) = 2.7 ± 0.3k B T c at 3.2 T and Δ(0) = 2.33 ± 0.07 k B T c at 7 T, indicating suppression of the order parameter by magnetic field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Role of the edge stochastic layer in density pump-out by resonant magnetic perturbations

The role of the edge stochastic layer on particle transport is addressed in DIII-D plasmas with applied resonant magnetic perturbations (RMPs) causing density pump-out (a term used to denote the density reduction at the top of the pedestal due to the applied RMPs). Using an analytical model that adds the stochastic parallel transport of electrons (Harvey et al 1981 Phys. Rev. Lett. 47 102) to the fluid equations, the ambipolar radial electric field and particle flux are calculated simultaneously. In this model the nonambipolar electron particle flux, driven by the stochastic magnetic field, is predominantly balanced by the nonambipolar perpendicular ion flux, driven by toroidal viscosity, across a narrow stochastic layer of order two percent of the plasma radius (0.98 < ψn < 1). The model reproduces the level of density pump-out and its dependence on RMP amplitude near the separatrix for three plasma discharges for which the pedestal foot is at medium to high collisionality $(2\leqslant {\nu }_{\text{sep}}^{\ast }\leqslant 30)$. In this work, the experimentally observed and numerically tested inverse density dependence of density pump-out (Hu et al 2020 Nucl. Fusion 60 076001) is accurately captured by the model: an increase in collisionality with density in the pedestal foot results in a decrease in stochastic diffusivity, and hence a decrease in the level of pump-out.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wide Operational Windows of Edge-Localized Mode Suppression by Resonant Magnetic Perturbations in the DIII-D Tokamak

Edge-Localized-Mode (ELM) suppression by resonant magnetic perturbations (RMPs) generally occurs over very narrow ranges of the plasma current (or magnetic safety factor $q_{95}$) in the DIII-D tokamak. However, wide $q_{95}$ ranges of ELM suppression are needed for the safety and operational flexibility of ITER and future reactors. In DIII-D ITER Similar Shape (ISS) plasmas with $n$=3 RMPs, the range of $q_{95}$ for ELM suppression is found to increase with decreasing electron density. Nonlinear two-fluid MHD simulations reproduce the observed $q_{95}$ windows of ELM suppression and the dependence on plasma density, based on the conditions for resonant field penetration at the top of the pedestal. When the RMP amplitude is close to the threshold for resonant field penetration, only narrow isolated magnetic islands form near the top of the pedestal, leading to narrow $q_{95}$ windows of ELM suppression. However, as the threshold for field penetration decreases with decreasing density, resonant field penetration can take place over a wider range of $q_{95}$. For sufficiently low density (penetration threshold) multiple magnetic islands form near the top of the pedestal giving rise to continuous $q_{95}$ windows of ELM suppression. The model predicts that wide $q_{95}$ windows of ELM suppression can be achieved at substantially higher pedestal pressure in DIII-D by shifting to higher toroidal mode number ($n$=4) RMPs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of resonant magnetic perturbations on radial electric fields in DIII-D tokamak

Here, gyrokinetic simulations of DIII-D tokamak equilibrium find that resonant magnetic perturbation (RMP) drives a neoclassical non-ambipolar electron particle flux, which causes a rapid change of equilibrium radial electric fields consistent with experimental observations during the suppression of the edge localized mode (ELM). The simulation results provide a support for the conjecture that RMP-induced changes of radial electric fields lead to the enhanced turbulent transport at the pedestal top during the ELM suppression (Taimourzadeh et al 2019 Nucl. Fusion 59 046005). Furthermore, gyrokinetic simulations of collisionless damping of zonal flows show that resonant responses to the RMP decrease the residual level of the zonal flows and damp the geodesic acoustic mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

RASER MRI: Magnetic resonance images formed spontaneously exploiting cooperative nonlinear interaction

The spatial resolution of magnetic resonance imaging (MRI) is limited by the width of Lorentzian point spread functions associated with the transverse relaxation rate 1/T 2 * . Here, we show a different contrast mechanism in MRI by establishing RASER (radio-frequency amplification by stimulated emission of radiation) in imaged media. RASER imaging bursts emerge out of noise and without applying radio-frequency pulses when placing spins with sufficient population inversion in a weak magnetic field gradient. Small local differences in initial population inversion density can create stronger image contrast than conventional MRI. This different contrast mechanism is based on the cooperative nonlinear interaction between all slices. On the other hand, the cooperative nonlinear interaction gives rise to imaging artifacts, such as amplitude distortions and side lobes outside of the imaging domain. Contrast mechanism and artifacts are explored experimentally and predicted by simulations on the basis of a proposed RASER MRI theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of resonant magnetic perturbations including toroidal sidebands on magnetic footprints and fast ion losses in HL-2M

Externally applied resonant magnetic perturbations (RMPs), generated by magnetic coils located outside the plasma (referred to as RMP coils), provide an effective way to control the edge localized mode (ELM) in tokamak devices. Due to the discrete nature of the toroidal distribution of these window-frame coils, toroidal sidebands always exist together with the fundamental harmonics designed for ELM control. In this work, the MARS-F code (Liu et al 2000 Phys. Plasmas7 3681) is applied to investigate the detailed features of the RMP spectra considering both the dominant harmonic (n = 2) and the associated sideband (n = 6), and the impact of the combined fields on magnetic footprints as well as on the fast ion losses for a reference double-null scenario in the HL-2M device. It is found that the sum of the n = 2 and n = 6 RMP fields splits the footprint and widens the footprint area, as compared to the single-n (n = 2) harmonic case. The resistive plasma response breaks the up–down symmetry of the footprint pattern on the outer divertor plates, which is otherwise symmetric assuming vacuum RMP fields. Considering fast ion losses, a threshold value exists for the initially launched radial position of test particles, as well as for the RMP coil current, before the loss occurs. When the threshold criterion is satisfied, the combined n = 2 and n = 6 RMP fields enhance the fast ion loss rate by , as compared to that of the n = 2 component alone. These results illustrate the important role of the sideband of RMP fields on the magnetic footprints and fast ion losses in tokamak plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pedestal collapse by resonant magnetic perturbations

Pedestal collapse (i.e., the complete loss of the edge transport barrier (ETB)) in DIII-D H-mode plasmas occurs when resonant magnetic perturbations (RMPs) penetrate the steep gradient region at the plasma edge. Normally, RMP driven magnetic islands can occur at the top and bottom of the H-mode pedestal and these islands generate conditions consistent with edge-localized-mode (ELM) suppression and density pump-out, respectively, based on nonlinear two-fluid MHD simulations. In contrast, MHD simulations show that the steep pressure gradient region between the top and bottom of the DIII-D pedestal is generally immune to resonant field penetration due to large local E × B and diamagnetic flows. By this fortuitous circumstance, the edge-transport-barrier and H-mode confinement can be maintained while achieving ELM suppression. However, pedestal collapse can occur in DIII-D when the screening flows are inadequate to prevent field penetration in the steep gradient region of the pedestal. Non-linear two-fluid MHD simulations support the role of resonant field penetration in pedestal collapse for DIII-D H-mode plasmas with weak edge E × B and diamagnetic screening flows. ITER will likely have weaker edge screening flows than present experiments due to its much larger size, making it more susceptible to resonant field penetration in the steep gradient region of the pedestal. Analysis of model ITER equilibria demonstrates that resonant field penetration in the steep pressure gradient region is possible for RMP levels of the order required for ELM suppression. The effect of such penetration on the ITER pedestal will depend sensitively on the resulting degree of island overlap.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reducing the Energy Consumption of Magnetic Resonance Imaging and Computed Tomography Scanners: Integrating Ecodesign and Sustainable Operations

This review aims to provide valuable insights into how energy consumption in magnetic resonance imaging (MRI) and computed tomography (CT) scanners can be effectively monitored, managed, and reduced, thereby contributing to more sustainable medical imaging practices. Demand for advanced imaging technologies such as MRI and CT scanners continues to increase, and understanding the resultant impact on greenhouse gas emissions requires a thorough evaluation of their energy consumption. Here, this review examines the energy monitoring and consumption characteristics of MRI and CT scanners, highlighting potential approaches for energy savings. An overview of MRI and CT principles, hardware components, and their associated energy consumption is provided. After addressing the technical aspects, the hardware and software requirements essential for accurate energy metering are detailed. Baseline measurements of energy consumption data are then provided as a foundation to understand current usage patterns and identify areas for improvement. Ongoing efforts to reduce energy consumption are categorized into 3 main strategies: operations, scanner design enhancements, and active scanning techniques, including accelerated MRI protocols. Ultimately, we emphasize that achieving sustainability in medical imaging requires collaboration across disciplines. By incorporating eco-friendly design in new imaging equipment, we can reduce the environmental impact, promote sustainability, and set a health care industry standard for a healthier planet.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clustering Nuclear Magnetic Resonance: Machine learning assistive rapid two‐dimensional relaxometry mapping

Abstract Low‐field nuclear magnetic resonance (NMR) relaxometry is an attractive approach from point‐of‐care testing medical diagnosis to in situ oil‐gas exploration. One of the problems, however, is the inherently long relaxation time of the (liquid) samples, (and hence low signal‐to‐noise ratio) which causes unnecessarily long repetition time. In this work, a new class of methodology is presented for rapid and accurate object classification using NMR relaxometry with the aid of machine learning. It is demonstrated that the sensitivity and specificity of the classification is substantially improved with higher order of (pseudo)‐dimensionality (e.g., 2D‐ or multi‐dimensional). This new methodology (termed as ‘Clustering NMR’) may be extremely useful for rapid and accurate object classification (in less than a minute) using low‐field NMR.

Peng, Weng Kung↗

Toward holistic understanding of the ITER-like resonant magnetic perturbation (RMP) ELM control on KSTAR

Here, KSTAR has clarified a set of unresolved 3D physics issues utilizing the ITER-like in-vessel, three-row, resonant magnetic perturbation (RMP) configurations. Since RMP-driven, edge-localized-modes (ELMs)-crash control elevates the divertor heat flux peak through its impact on edge plasma parameters and transport, a series of intentionally misaligned RMP configurations (IMCs) have been explored to investigate the relationship between RMP ELM control and divertor heat fluxes, while searching for an ideal IMC that could be favorable in both aspects. First of all, the contrasting influence of kink vs anti-kink phasing on the ELM-crash suppression has been articulated, demonstrating the synergistic benefit of 'kink' phasing on ELM-crash-suppression. On the other hand, the three-row IMC in the anti-kink phasing becomes more insensitive to the ELM-crashes at the sub-marginal level of RMP, consistent with theory. Meanwhile, the divertor 'wetted' area of ELM-crash-suppression gets narrower than that of ELM-crash-mitigation, suggesting that ELM-crash-mitigation remains advantageous over ELM-crash-suppression in terms of time-averaged divertor thermal loading. In comparison, based on a set of two-row IMCs, no evidence of divertor heat flux broadening was found during ELM-crash-suppression, supporting a hypothesis that the dispersal of the divertor heat flux in three-row IMCs cannot be driven by helically structured two-row RMPs alone. Among ITER-like three-rows, lower two-row RMPs have been found to be much more effective in suppressing the ELM-crashes than upper two-row RMPs. Although it is quite preliminary, the up/down asymmetric dependence of RMP coupling may be generically attributed to lower-single-null plasmas. Such a holistic understanding of RMP-driven, ELM-crash-control in KSTAR is expected not only to elucidate various subtle points in the vicinity of ELM-crash-suppression, but also to clarify the relevant divertor thermal loading issues for ITER and beyond.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution ultra-low field magnetic resonance imaging with a high-sensitivity sensing coil

We present high-resolution magnetic resonance imaging (MRI) at ultra-low field (ULF) with a proton Larmor frequency of around 120 kHz. The key element is a specially designed high-sensitivity sensing coil in the shape of a solenoid with a few millimeter gap between windings to decrease the proximity effect and, hence, increase the coil’s quality ([Formula: see text]) factor and sensitivity. External noise is strongly suppressed by enclosing the sensing coil in a copper cylindrical shield, large enough not to negatively affect the coil’s [Formula: see text] factor and sensitivity, measured to be 217 and 0.47 fT/Hz[Formula: see text], respectively. To enhance small polarization of proton spins at ULF, a strong pulsed 0.1 T prepolarization field is applied, making the signal-to-noise ratio (SNR) of ULF MRI sufficient for high-quality imaging in a short time. We demonstrate ULF MRI of a copper sulfate solution phantom with a resolution of [Formula: see text] and SNR of 10. The acquisition time is 6.3 min without averaging. The sensing coil size in the current realization can accommodate imaging objects of 9 cm in size, sufficient for hand, and it can be further increased for human head imaging in the future. Since the in-plane resolution of [Formula: see text] is typical in anatomical medical imaging, this ULF MRI method can be an alternative low-cost, rapid, portable method for anatomical medical imaging of the human body or animals. This ULF MRI method can supplement other MRI methods, especially when such methods are restricted due to high cost, portability requirement, imaging artifacts, and other factors.

59 BASIC BIOLOGICAL SCIENCES↗

Detecting rare earth elements via optically detected magnetic resonance (ODMR) and spin-relaxometry using nitrogen vacancy centers in nanodiamonds

Nanodiamonds embedded with nitrogen-vacancy (NV) centers are emerging as powerful tools in quantum sensing due to their remarkable sensitivity to local variations in electromagnetic fields, temperature, and pressure. These point defects in the diamond lattice can be probed using optically detected magnetic resonance (ODMR) and spin relaxometry techniques, allowing for the detection and characterization of magnetic nanoparticles and ions. The sensing mechanism relies on laser-induced excitation of the NV center's non-degenerate triplet ground state, which promotes electrons to an excited state. Subsequent photoluminescence (PL) emission, which is spin-state dependent, is then measured. These spin states are highly responsive to magnetic perturbations in the surrounding environment. By analyzing changes in the ODMR spectra and spin relaxation times, we can effectively monitor how magnetic species influence the NV center's spin dynamics, thus enabling sensitive and selective characterization of nanoscale magnetic materials. These techniques have been applied for the characterization of transition metals and rare earth elements which shows natural ferromagnetic properties.

magnetic nanopartgicles and ions↗