At least 73 records · Page 4

Magnetocaloric effect in the vicinity of the magnetic phase transition in NdCo 2–x Fe x compounds

In the present paper, the magnetocaloric effect (MCE) of NdCo 2-x Fe x (x = 0, 0.2, 0.4, 0.6) compounds was investigated by magnetization measurements. Here, the temperature-dependent high-resolution synchrotron x-ray diffraction study shows a magnetostructural transition from the paramagnetic cubic phase to the ferromagnetic tetragonal phase below their Curie temperatures. Differential scanning calorimetry analysis shows the absence of thermal hysteresis, indicating the second-order nature of the magnetostructural phase transition in these compounds. The maximum values of magnetic entropy change (ΔS M ) and wide operating temperature (OT) are obtained under a field change of 5 T, which are 7.33 Jkg -1 K -1 , 6.45 Jkg -1 K -1 , 5.71 Jkg -1 K -1 , 4.70 Jkg -1 K -1 and 78 K, 82 K, 85 K, 92 K for x = 0, 0.2, 0.4, and 0.6, respectively. The corresponding values of relative cooling power (RCP) are 529.96 Jkg -1 , 497.25 Jkg -1 , 470.55 Jkg -1 , and 428.31 Jkg -1 . The observed wide OT range and large RCP values are comparable with Gd, Gd 5 Ge 2 Si 2 , and some rare-earth-based giant magnetocaloric materials, making this series of compounds suitable for magnetic refrigeration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Benefit FOA FY2015 - Solid State Magnetocaloric Air Conditioner (Final Report)

The active magnetic refrigeration (AMR) cycle holds great promise to reduce energy consumption of space cooling and heating. It is estimated that it could achieve up to 25% improvement in energy efficiency over conventional vapor compression systems. Prototypes have been built and demonstrated the working principles and energy benefits of the technology. These prototypes however were of low specific cooling power, defined as cooling power obtainable from unit mass of magnetocaloric materials (MCM). Specific cooling power is inversely proportional to the cost of the system. Therefore, for the magnetocaloric technology to be commercially viable, the specific cooling power must be increased. To increase the specific cooling power, for any MCM, the frequency of operation must increase. However, the maximum frequency that an AMR can operate at is limited by the residence time that is required to transfer heat in and out of the regenerator during the cold and got blows. This time length is dependent on the thermal conductivity of the heat transfer medium. The higher the thermal conductivity of the heat transfer medium, the faster heat can be transferred between the medium and the MCM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Magnetism, dimensional changes, and magnetic transitions in hydrated cesium manganese chloride

Dimensional changes (strain) along the three principal crystal axes of the antiferromagnet CsMnCl3-2H2O are studied as a function of magnetic field and temperature in the antiferromagnetic, spin flopped, and paramagnetic phases. Changes in dimensions through the phase transitions between the magnetic states are examined. By applying the molecular field model and utilizing all available information, magnetic properties of CsMnCl3-2H2O are determined. The possible usefulness of this material in a magnetic refrigeration cycle is evaluated.

Woollam, J. A.↗

Magnetization and magnetic entropy of Dy2Ti2O7

Isothermal measurements of the magnetic entropy, magnetization, and differential susceptibility of Dy2Ti2O7 have been made. Absolute values of magnetic entropy have been determined as a function of applied magnetic field for several temperatures in the range 2-20 K, and several isofield lines in the magnetic entropy-temperature plane have been determined. Magnetization measurements, which extended into the saturation region, yield a powder-average magnetic moment of about 4.7 Bohr magnetons per ion. A van Vleck contribution to M was also observed. The results are consistent with the assumption of a nearly pure Jz equals + or - 15/2 ground-state Kramers doublet for the Dy(+++) ion. Comments on the suitability of Dy2Ti2O7 for use in a magnetic refrigerator cycling between 4.2 and 20 K are included.

Flood, D. J.↗

Experiment to determine properties of packed particle beds and regenerators at cryogenic temperatures

Studies related to the development of magnetic refrigeration and heat pump systems in temperature ranges from 4 K to ambient temperature and above have been conducted, taking into account the testing of the properties of packed-particle beds and regenerators at cryogenic temperatures as low as 4 K as an essential part of these studies. The present paper provides a description of the developed experimental apparatus and presents the results of recent measurements on packed-particle beds in the liquid helium and liquid nitrogen temperature ranges. Attention is given to a schematic of the apparatus and the data acquisition system, the various modes of gas flow, a schematic of a typical test bed with thermocouple positions, the calculation of transient heat transfer rates at different positions in the bed, the governing equations, and the procedures used for solving these equations.

Barclay, J. A.↗

Space applications of high temperature superconductivity technology

A review is presented of the present status of high temperature superconductivity (HTS) technology and related areas of potential space application. Attention is given to areas of application that include microwave communications, cryogenic systems, remote sensing, and space propulsion and power. Consideration is given to HTS phase shifters, miniaturization of microwave filters, far-IR bolometers, and magnetic refrigeration using flux compression.

Connolly, D. J.↗

NASA's Software Bank (SINDA 1985/FLUINT)

Astronautics Corporation uses SINDA '85/FLUINT to model designs for efficient magnetic refrigeration devices. The proposed designs are compared for relative efficiency, and the best concept is selected. SINDA is later used to develop a more complex model for predicting temperature distribution in the refrigeration.

Source record↗

Passive Superconducting Shielding: Experimental Results and Computer Models

Passive superconducting shielding for magnetic refrigerators has advantages over active shielding and passive ferromagnetic shielding in that it is lightweight and easy to construct. However, it is not as easy to model and does not fail gracefully. Failure of a passive superconducting shield may lead to persistent flwc and persistent currents. Unfortunately, modeling software for superconducting materials is not as easily available as is software for simple coils or for ferromagnetic materials. This paper will discuss ways of using available software to model passive superconducting shielding.

Warner, Brent↗

Passive Superconducting Shielding: Experimental Results and Computer Models

Passive superconducting shielding for magnetic refrigerators has advantages over active shielding and passive ferromagnetic shielding in that it is lightweight and easy to construct. However, it is not as easy to model and does not fail gracefully. Failure of a passive superconducting shield may lead to persistent flux and persistent currents. Unfortunately, modeling software for superconducting materials is not as easily available as is software for simple coils or for ferromagnetic materials. This paper will discuss ways of using available software to model passive superconducting shielding.

Warner, B. A.↗

NASA Tech Briefs, August 2012

Topics covered include: Mars Science Laboratory Drill; Ultra-Compact Motor Controller; A Reversible Thermally Driven Pump for Use in a Sub-Kelvin Magnetic Refrigerator; Shape Memory Composite Hybrid Hinge; Binding Causes of Printed Wiring Assemblies with Card-Loks; Coring Sample Acquisition Tool; Joining and Assembly of Bulk Metallic Glass Composites Through Capacitive Discharge; 670-GHz Schottky Diode-Based Subharmonic Mixer with CPW Circuits and 70-GHz IF; Self-Nulling Lock-in Detection Electronics for Capacitance Probe Electrometer; Discontinuous Mode Power Supply; Optimal Dynamic Sub-Threshold Technique for Extreme Low Power Consumption for VLSI; Hardware for Accelerating N-Modular Redundant Systems for High-Reliability Computing; Blocking Filters with Enhanced Throughput for X-Ray Microcalorimetry; High-Thermal-Conductivity Fabrics; Imidazolium-Based Polymeric Materials as Alkaline Anion-Exchange Fuel Cell Membranes; Electrospun Nanofiber Coating of Fiber Materials: A Composite Toughening Approach; Experimental Modeling of Sterilization Effects for Atmospheric Entry Heating on Microorganisms; Saliva Preservative for Diagnostic Purposes; Hands-Free Transcranial Color Doppler Probe; Aerosol and Surface Parameter Retrievals for a Multi-Angle, Multiband Spectrometer LogScope; TraceContract; AIRS Maps from Space Processing Software; POSTMAN: Point of Sail Tacking for Maritime Autonomous Navigation; Space Operations Learning Center; OVERSMART Reporting Tool for Flow Computations Over Large Grid Systems; Large Eddy Simulation (LES) of Particle-Laden Temporal Mixing Layers; Projection of Stabilized Aerial Imagery Onto Digital Elevation Maps for Geo-Rectified and Jitter-Free Viewing; Iterative Transform Phase Diversity: An Image-Based Object and Wavefront Recovery; 3D Drop Size Distribution Extrapolation Algorithm Using a Single Disdrometer; Social Networking Adapted for Distributed Scientific Collaboration; General Methodology for Designing Spacecraft Trajectories; Hemispherical Field-of-View Above-Water Surface Imager for Submarines; and Quantum-Well Infrared Photodetector (QWIP) Focal Plane Assembly.

Source record↗

Design of the PIXIE Adiabatic Demagnetization Refrigerators

The Primordial Inflation Explorer (PIXIE) is a proposed mission to densely map the polarization of the cosmic microwave background. It will operate in a scanning mode from a sun-synchronous orbit, using low temperature detectors (at 0.1 K) and located inside a teslescope that is cooled to approximately 2.73 K - to match the background temperature. A mechanical cryocooler operating at 4.5 K establishes a low base temperature from which two adiabatic demagnetization refrigerator (ADR) assemblies will cool the telescope and detectors. To achieve continuous scanning capability, the ADRs must operate continuously. Complicating the design are two factors: 1) the need to systematically vary the temperature of various telescope components in order to separate the small polarization signal variations from those that may arise from temperature drifts and changing gradients within the telescope, and 2) the orbital and monthly variations in lunar irradiance into the telescope barrels. These factors require the telescope ADR to reject quasi-continuous heat loads of 2-3 millwatts, while maintaining a peak heat reject rate of less than 12 milliwatts. The detector heat load at 0.1 K is comparatively small at 1-2 microwatts. This paper will describe the 3-stage and 2-stage continuous ADRs that will be used to meet the cooling power and temperature stability requirements of the PIXIE detectors and telescope.

adiabatic demagnetization refrigerator↗

3-Stage ADR for the X-Ray Imaging and Spectrometer Mission (XRISM)

Following the loss of the Hitomi x-ray astronomy satellite shortly after its launch in early 2016, the US and Japanese space agencies (NASA and JAXA) agreed to fund a replacement mission, presently called the X-Ray Imaging and Spectroscopy Mission (XRISM). XRISM will include only the two soft x-ray instruments from Hitomi, the Soft X-ray Spectrometer (SXS), and the Soft X-ray Imager (SXI). The spectrometer instrument, now named Resolve, will be similar to the original SXS design. It consists of a 6 by 6 array of silicon microcalorimeters cooled to 50 millikelvin by means of a 3-stage Adiabatic Demagnetization Refrigerator (ADR) whose operation is supported by a 40 liter superfluid helium tank, a 4.5-degrees-Kelvin Joule-Thomson cryocooler and a number of 2-stage Stirling cryocoolers. These components were all successfully demonstrated on Hitomi before its failure. This talk will summarize the design of the XRISM ADR and how it differs from the SXS version.

ADR (Adiabatic Demagnetization Refrigerator)↗

Active magnetic regenerative processes and systems employing hydrogen as heat transfer fluid and process gas

A system including:an active magnetic regenerative refrigerator apparatus that includes a high magnetic field section in which a hydrogen heat transfer fluid can flow from a cold side to a hot side through at least one magnetized bed of at least one magnetic refrigerant, and a low magnetic field or demagnetized section in which the hydrogen heat transfer fluid can flow from a hot side to a cold side through the demagnetized bed;a first conduit fluidly coupled between the cold side of the low magnetic field or demagnetized section and the cold side of the high magnetic field section; anda second conduit fluid coupled to the first conduit, an expander and at least one liquefied hydrogen storage module.

Holladay, Jamie D.↗

Design of a horizonal liquid helium cryostat for refrigerating a flying superconducting magnet in a wind tunnel

The design of a horizontal liquid helium cryostat for refrigerating a flying superconducting magnet in a wind tunnel is presented. The basic principles of magnetic suspension theory are described and theoretical calculations of the superconducting magnet are provided. The experimental results of the boil-off of liquid nitrogen and liquid helium in the cryostat are reported.

Wu, Y. Y.↗

Micromachined Active Magnetic Regenerator for Low-Temperature Magnetic Coolers

A design of an Active Magnetic Regenerative Refrigeration (AMRR) system has been developed for space applications. It uses an innovative 3He cryogenic circulator to provide continuous remote/distributed cooling at temperatures in the range of 2 K with a heat sink at about 15 K. A critical component technology for this cooling system is a highly efficient active magnetic regenerator, which is a regenerative heat exchanger with its matrix material made of magnetic refrigerant gadolinium gallium garnet (GGG). Creare Inc. is developing a microchannel GGG regenerator with an anisotropic structured bed for high system thermal efficiency. The regenerator core consists of a stack of thin, single-crystal GGG disks alternating with thin polymer insulating layers. The insulating layers help minimize the axial conduction heat leak, since GGG has a very high thermal conductivity in the regenerator s operating temperature range. The GGG disks contain micro channels with width near 100 micrometers, which enhance the heat transfer between the circulating flow and the refrigerant bed. The unique flow configuration of the GGG plates ensures a uniform flow distribution across the plates. The main fabrication challenges for the regenerator are the machining of high-aspect-ratio microchannels in fragile, single-crystal GGG disks and fabrication and assembly of the GGG insulation layers. Feasibility demonstrations to date include use of an ultrashort- pulse laser to machine microchannels without producing unacceptable microcracking or deposition of recast material, as shown in the figure, and attachment of a thin insulation layer to a GGG disk without obstructing the flow paths. At the time of this reporting, efforts were focused on improving the laser machining process to increase machining speed and further reduce microcracking.

Chen, Weibo↗

Improvement on the Magnetic Shielding for the XRISM/Resolve Adiabatic Demagnetization Refrigerator

We report modeling, fabrication, cryogenic tensile testing, and magnetic field measurements of a shield around an adiabatic demagnetization stage (ADR) built for the XRISM/Resolve instrument. During testing of a near-identical stage built for Astro-H, a previous spaceflight mission, it was determined that the magnet at full current generated a field external to the shield that violated the maximum dipole-moment requirement of the spacecraft. In addition, there was an interference with the detector assembly nearby when the magnet was greater than 85% of it's typical maximum current. Starting with the Astro-H shield design, we performed a parametric study that increased the thickness of the shield in critical regions. This calculation proceeded until the magnetic field satisfied the estimated maximum field allowed at the detector array based upon the Astro-H measurements. We also performed a detailed measurement of the field generated by the ADR stage at full current as a function of relative angle between the magnet axis and a series of flux-gate magnetometers. Details and results from the calculation and subsequent measurement will be presented.

ADR↗

Magnetic-Flux-Compression Cooling Using Superconductors

Proposed magnetic-flux-compression refrigeration system produces final-stage temperatures below 4.2 K. More efficient than mechanical and sorption refrigerators at temperatures in this range. Weighs less than comparable liquid-helium-cooled superconducting magnetic refrigeration systems operating below 4.2 K. Magnetic-flux-compression cooling stage combines advantages of newly discovered superconductors with those of cooling by magnetization and demagnetization of paramagnetic salts.

Strayer, Donald M.↗

Magnetically suspended Stirling cryogenic space refrigerator Status report

At the 1979 Cryogenic Engineering Conference, attention was given to conceptual designs of spaceborne cryogenic refrigeration systems which can provide long-term, unattended operation. Since that time, efforts have continued to translate one of those concepts into an engineering model. The present investigation is concerned with a refrigerator which was designed to generate 5 W of cooling power at a temperature of 65 K. The compression heat of the refrigerator is dissipated at a temperature of 300 K, and the output of the system is to be maintained reliably for a period of five years or longer. The refrigerator design is based on the Stirling cycle, which has an ideal efficiency equal to that of the Carnot cycle. Attention is given to some background information concerning a cryogenic refrigerator, the design of the refrigerator components, and the development status. The magnetic bearings and the linear motors have been tested at the component level.

Daniels, A.↗