Search NASA⌕ Search

SEARCH · Search NASA

Results for “Magnetostatics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Assessment of ALEGRA Computation for Magnetostatic Configurations

Here, a closed-form solution is described here for the equilibrium configurations of the magnetic field in a simple heterogeneous domain. This problem and its solution are used for rigorous assessment of the accuracy of the ALEGRA code in the quasistatic limit. By the equilibrium configuration we understand the static condition, or the stationary states without macroscopic current. The analysis includes quite a general class of 2D solutions for which a linear isotropic metallic matrix is placed inside a stationary magnetic field approaching a constant value H i ° at infinity. The process of evolution of the magnetic fields inside and outside the inclusion and the parameters for which the quasi-static approach provides for self-consistent results is also explored. Lastly, it is demonstrated that under spatial mesh refinement, ALEGRA converges to the analytic solution for the interior of the inclusion at the expected rate, for both body-fitted and regular rectangular meshes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characteristics of Magnetization Reversal of Magnetostatically Coupled Microwire-Based System

The magnetization reversal process of a system consisted of one Co{sub 67}Fe{sub 3.9}Ni{sub 1.5}B{sub 12.5}Si{sub 14.5}Mo{sub 0.6} and one Fe{sub 74}B{sub 13}Si{sub 11}C{sub 2} microwires was studied. The change of the magnetic characteristics of a system (slope and shape of the hysteresis loop, coercive force) under effect of the neighbor and the length of the system (in the range of 3–20 mm) was considered and analyzed in terms of effective demagnetizing field influence.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Non-axisymmetric local magnetostatic equilibrium

In this study, we outline an approach to the problem of local equilibrium in non-axisymmetric configurations that adheres closely to Miller's original method for axisymmetric plasmas. Importantly, this method is novel in that it allows not only specification of 3D shape, but also explicit specification of the shear in the 3D shape. A spectrally-accurate method for solution of the resulting nonlinear partial differential equations is also developed. We verify the correctness of the spectral method, in the axisymmetric limit, through comparisons with an independent numerical solution. Some analytic results for the two-dimensional case are given, and the connection to Boozer coordinates is clarified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Guiding centre motion for particles in a ponderomotive magnetostatic end plug

The Hamiltonian dynamics of a single particle in a rotating plasma column, interacting with an magnetic multipole is perturbatively solved for up to second order, using the method of Lie transformations. First, the exact Hamiltonian is expressed in terms of canonical action-angle variables, and then an approximate integrable Hamiltonian is introduced, using another set of actions and angles, which describe the centre of oscillation for the particle. The perturbation introduces an effective ponderomotive potential, which to leading order is positive. At the second order, the pseudopotential consists of a sum of terms of the Miller form, and can have either sign. Additionally, at second order, the ponderomotive interaction introduces a modification to the particle effective mass, when considering the motion along the column axis. It is found that particles can be axially confined by the ponderomotive potentials, but acquire radial excursions which scale as the confining potential. The radial excursions of the particle along its trajectory are investigated, and a condition for the minimal rotation frequency for which the particle remains radially confined is derived. Last, we comment on the changes to the aforementioned solution to the pseudopotentials and particle trajectory in the case of resonant motion, that is, a motion which has the same periodicity as the perturbation.

Rubin, T. (ORCID:0000000164850096)↗

Magnetostatic twists in room-temperature skyrmions explored by nitrogen-vacancy center spin texture reconstruction

Abstract Magnetic skyrmions are two-dimensional non-collinear spin textures characterized by an integer topological number. Room-temperature skyrmions were recently found in magnetic multilayer stacks, where their stability was largely attributed to the interfacial Dzyaloshinskii–Moriya interaction. The strength of this interaction and its role in stabilizing the skyrmions is not yet well understood, and imaging of the full spin structure is needed to address this question. Here, we use a nitrogen-vacancy centre in diamond to measure a map of magnetic fields produced by a skyrmion in a magnetic multilayer under ambient conditions. We compute the manifold of candidate spin structures and select the physically meaningful solution. We find a Néel-type skyrmion whose chirality is not left-handed, contrary to preceding reports. We propose skyrmion tube-like structures whose chirality rotates through the film thickness. We show that NV magnetometry, combined with our analysis method, provides a unique tool to investigate this previously inaccessible phenomenon.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetostatic and magnetohydrodynamic modeling of planar wire arrays

For the past 2 years the planar wire array loads have proven their ability to create powerful x-ray radiation sources at the pulsed power facilities with the current level ranging from 1 to 3 MA. Several key features of the implosion and ablation dynamics of the planar wire arrays distinguish them from the wire arrays of the conventional cylindrical design. The uneven current partition through the array wires in planar geometry results in a significant difference between the ablation rates of the outermost and the innermost array wires. This difference is even higher in a double row planar array geometry. According to the three-dimensional magnetohydrodynamic simulations the effect of the delayed ablation of the inner array wires can result in effective mitigation of the Rayleigh-Taylor instability modes. The high number (200-300) of wires in a cylindrical array is preferable to ensure fine azimuthal symmetry of an array implosion. However this requirement is not a great concern for the planar wire array loads, which implode along the plane of wires. Hence, the low-wire-number planar array loads are naturally optimized for the Z-pinch experiments at short pulse (100 ns) 1 MA facilities. The application of planar wire array loads at high current accelerators is attractive for the purposes of the inertial confinement fusion because of the relative compactness of these loads and their potential for radiation pulse shaping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear periodic solutions for isothermal magnetostatic atmospheres

Magnetohydrodynamic equilibria for a plasma in a gravitational field are investigated analytically. For equilibria with one ignorable spatial coordinate, the equations reduce to a single nonlinear elliptic equation for the magnetic potential A, known as the Grad-Shafranov equation. Specifying the arbitrary functions in the latter equation, one obtains three types of nonlinear elliptic equations (a Liouville equation, a sinh Poisson equation, and a generalization of those with a sum of exponentials). Analytical solutions are obtained using the tanh method; this is elaborated in the Appendix. The solutions are adequate to describe an isothermal atmosphere in a uniform gravitational field showing parallel filaments of diffuse, magnetized plasma suspended horizontally in equilibrium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

End-compensated magnetostatic cavity for polarized {sup 3}He neutron spin filters

We have expanded upon the ''Magic Box'' concept, a coil driven magnetic parallel plate capacitor constructed out of mu-metal, by introducing compensation sections at the ends of the box that are tuned to limit end-effects similar to those of short solenoids. This ability has reduced the length of the magic box design without sacrificing any loss in field homogeneity, making the device far more applicable to the often space limited neutron beam line. The appeal of the design beyond affording longer polarized {sup 3}He lifetimes is that it provides a vertical guide field, which facilitates neutron spin transport for typical polarized beam experiments. We have constructed two end-compensated magic boxes of dimensions 28.4x40x15 cm{sup 3} (lengthxwidthxheight) with measured, normalized volume-averaged transverse field gradients ranging from 3.3x10{sup -4} to 6.3x10{sup -4} cm{sup -1} for cell sizes ranging from 8.1x6.0 to 12.0x7.9 cm{sup 2} (diameterxlength), respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charged particle reflection from an artificially structured boundary that produces a spatially periodic magnetostatic field

Charged particle reflection away from an artificially structured boundary is studied by computer simulation. The artificially structured boundary produces a spatially periodic static magnetic field such that the spatial period of the field is much smaller than the dimensions of a source of incident charged particles. A planar artificially structured boundary comprised of a sequence of parallel wires is considered. The wires carry currents in alternating directions and produce the magnetic field. A classical trajectory Monte Carlo study is reported. The motion of charged particles that approach the artificially structured boundary at small or grazing angles of incidence transverse to the wires is simulated. The conditions under which the charged particles reflect away from the boundary without reaching it are determined, and the results are fit to obtain analytical expressions. The results are not dependent on the sign of charge of the incident particles.

43 PARTICLE ACCELERATORS↗

Influence of magnetostatic interactions on the magnetization reversal of patterned magnetic elements

The magnetization reversal in patterned thin-film arrays of elliptical submicron permalloy elements has been investigated by magnetic-force microscopy and micro-magneto-optic Kerr effect. Three different spatial arrangements of chains are considered, namely chains aligned parallel to the long axis of the ellipse, chains aligned parallel to the short axis of the ellipse, and arrays with roughly equal element-to-element spacings in both directions. Comparison of the hysteresis loops in an in-plane field perpendicular to the ellipses' long axes shows that the magnetization reversibility is highest for chains along the long axis. This is due to the nearly coherent magnetization rotation in the applied magnetic field and to the formation of a head-to-tail domain arrangement. Other arrangements, such as chains of ellipses aligned parallel to short axis, yield flux-closure domains as the applied magnetic field is changed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SIMPLE ANALYTICAL FORMS OF THE PERPENDICULAR DIFFUSION COEFFICIENT FOR TWO-COMPONENT TURBULENCE. I. MAGNETOSTATIC TURBULENCE

We explore perpendicular diffusion based on the unified nonlinear transport theory. We derive simple analytical forms for the perpendicular mean free path and investigate the influence of different model spectra. We show that for cases where the field line random walk is normal diffusive, the perpendicular diffusion coefficient consists of only two transport regimes. Details of the spectral shape are less important, especially those of the inertial range. Only the macroscopic properties of the turbulence spectrum control the perpendicular diffusion coefficient. Simple formulae for the perpendicular diffusion coefficient are derived which can easily be implemented in solar modulation or shock acceleration codes.

79 ASTRONOMY AND ASTROPHYSICS↗

Axial to transverse energy mixing dynamics in octupole-based magnetostatic antihydrogen traps

Abstract The nature of the trajectories of antihydrogen atoms confined in an octupole minimum-B trap is of great importance for upcoming spectroscopy, cooling, and gravity experiments. Of particular interest is the mixing time between the axial and transverse energies for the antiatoms. Here, using computer simulations, we establish that almost all trajectories are chaotic, and then quantify the characteristic mixing time between the axial and transverse energies. We find that there are two classes of trajectories: for trajectories whose axial energy is higher than about 20% of the total energy, the axial energy substantially mixes within about 10 s, whereas for trajectories whose axial energy is lower than about 10% of the total energy, the axial energy remains nearly constant for 1000 s or longer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetostatic dipolar domain-wall pinning in chains of permalloy triangular rings.

In a combined experimental and numerical study, we investigated the details of the motion and pinning of domain walls in isolated and interacting permalloy triangular rings (side 2 {micro}m, width 250 nm, and thickness 25 nm). To induce interaction between the rings, they were arranged either in vertical chains with an apex of each triangle in proximity to the edge center of the triangle above it or in horizontal chains where the proximity is between the adjacent corners of the triangles. Using longitudinal and diffraction magneto-optic Kerr effects, magnetic force microscopy, and micromagnetic simulations, we determined the field dependence of the spin structure in the rings. In all cases the remnant state of each ring is an 'onion' state characterized by two domain walls - one head to head the other tail to tail - pinned at the apexes. In isolated rings the magnetization reversal occurs between two onion states via the formation of an intermediate vortex state, which arises from the motion and annihilation of the two domain walls. In the case of the horizontal chains the reversal mechanism is unchanged except that the dipolar interaction affects the field range in which the rings are in the vortex state. In the case of vertical chains an additional intermediate state is observed during reversal. The new state involves a domain wall pinned at the center of the edge that is in close proximity to the apex of its neighbor. We show that the domain-wall motion in this last case can be modeled by a triple potential well. Because the new state requires that a domain wall be pinned at the neighboring apex, our observations can be viewed as a very elementary form of magnetic logic.

36 MATERIALS SCIENCE↗

Analogs of the double-Reissner-Nordstroem solution in magnetostatics and dilaton gravity: Mathematical description and basic physical properties

In this paper we consider a magnetic analog of the double-Reissner-Nordstroem solution and construct the corresponding magnetic potential A{sub {phi}} in the explicit form. The behavior of the resulting solution under the Harrison transformation then naturally singles out the asymmetric black diholes--configurations composed of two nonextreme black holes possessing unequal masses, and charges equal in magnitude but opposite in sign - as its most general subclass for which equilibrium of the black-hole constituents can be achieved with the aid of the external magnetic (or electric) field. We also generalize the double-Reissner-Nordstroem solution to dilaton gravity with arbitrary dilaton coupling, yielding the four-dimensional double-Gibbons-Maeda spacetime. The study of some physical properties of the solutions obtained leads, in particular, to very simple formulas for the areas of the horizons and surface gravities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetostatic focal spot correction for x-ray tubes operating in strong magnetic fields using iterative optimization

Purpose: Combining x-ray fluoroscopy and MR imaging systems for guidance of interventional procedures has become more commonplace. By designing an x-ray tube that is immune to the magnetic fields outside of the MR bore, the two systems can be placed in close proximity to each other. A major obstacle to robust x-ray tube design is correcting for the effects of the magnetic fields on the x-ray tube focal spot. A potential solution is to design active shielding that locally cancels the magnetic fields near the focal spot. Methods: An iterative optimization algorithm is implemented to design resistive active shielding coils that will be placed outside the x-ray tube insert. The optimization procedure attempts to minimize the power consumption of the shielding coils while satisfying magnetic field homogeneity constraints. The algorithm is composed of a linear programming step and a nonlinear programming step that are interleaved with each other. The coil results are verified using a finite element space charge simulation of the electron beam inside the x-ray tube. To alleviate heating concerns an optimized coil solution is derived that includes a neodymium permanent magnet. Any demagnetization of the permanent magnet is calculated prior to solving for the optimized coils. The temperature dynamics of the coil solutions are calculated using a lumped parameter model, which is used to estimate operation times of the coils before temperature failure. Results: For a magnetic field strength of 88 mT, the algorithm solves for coils that consume 588 A/cm{sup 2}. This specific coil geometry can operate for 15 min continuously before reaching temperature failure. By including a neodymium magnet in the design the current density drops to 337 A/cm{sup 2}, which increases the operation time to 59 min. Space charge simulations verify that the coil designs are effective, but for oblique x-ray tube geometries there is still distortion of the focal spot shape along with deflections of approximately 3 mm in the radial and circumferential directions on the anode. Conclusions: Active shielding is an attractive solution for correcting the effects of magnetic fields on the x-ray focal spot. If extremely long fluoroscopic exposure times are required, longer operation times can be achieved by including a permanent magnet with the active shielding design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗