Extraction of mass spectra free of background and neighboring component contributions from gas chromatography/mass spectrometry data
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Electron impact fragmentation patterns were obtained for 1,4-bis[(5-perfluoro-n-heptyl)-1,2,4-oxadiazolyl- benzene, its perfluoroalkylether substituted analogue, 3,5-bis(perfluoroalkyl)-, 3,5-bis(perfluoroalkylether)- and 3-perfluoroalkylether-5-perfluoroalkyl-1,2,4-oxadiazoles. In the compounds containing the phenylene group the molecular ion constituted the base peak; the main process was the breakdown of the oxadiazole ring with concurrent liberation of the perfluoroalkyl or perfluoroalkylether nitrile molecule; cleavage of the fluorinated chain ot to the oxadiazole ring was found to take place to a considerable degree. In the perfluorinated 1,2,4-oxadiazoles cleavage beta to the oxadiazole ring occurred preferentially; fragmentation of the ring itself took place to a limited degree only. The 3-perfluoroalkylether-5-perfluoroalkyl-1,2,4-oxadiazole appeared to undergo the primary beta-cleavage exclusively at the perfluoroalkylether sidechain.
This proposal was for a detailed analysis of the far ultraviolet (FUV) photoionizing radiation that provides crucial input physics for mass loss studies, e.g., observations of the flux below 10448, allow us to constrain the Ca II/Ca III balance and make significant progress beyond previous optical studies on stellar mass loss and circumstellar photochemistry. Our targets selection provided good spectral-type coverage required to help unravel the Ca II/Ca III balance as the mass-loss rates increase by over three orders of magnitude from K5 III to M5 III. We also explored the relationship between the FUV radiation field and other UV diagnostics to allow us to empirically estimate the FUV radiation field for the vast majority of stars which are too faint to be observed with FUSE, and to improve upon their uncertain mass-loss rates.
The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250
A technique which employs known gas mixtures to calibrate the residual gas analyzer (RGA) is described. The mass spectra from the RGA are recorded for each gas mixture. This mass spectra data and the mixture composition data each form a matrix. From the two matrices the calibration matrix may be computed. The matrix mathematics requires the number of calibration gas mixtures be equal to or greater than the number of gases included in the calibration. This technique was evaluated using a mathematical model of an RGA to generate the mass spectra. This model included shot noise errors in the mass spectra. Errors in the gas concentrations were also included in the valuation. The effects of these errors was studied by varying their magnitudes and comparing the resulting calibrations. Several methods of evaluating an actual calibration are presented. The effects of the number of gases in then, the composition of the calibration mixture, and the number of mixtures used are discussed.
Identification of small molecules is a critical task in various areas of life science. Recent advances in mass spectrometry have enabled the collection of tandem mass spectra of small molecules from hundreds of thousands of environments. To identify which molecules are present in a sample, one can search mass spectra collected from the sample against millions of molecular structures in small molecule databases. The existing approaches are based on chemistry domain knowledge, and they fail to explain many of the peaks in mass spectra of small molecules. Here, we present molDiscovery, a mass spectral database search method that improves both efficiency and accuracy of small molecule identification by learning a probabilistic model to match small molecules with their mass spectra. A search of over 8 million spectra from the Global Natural Product Social molecular networking infrastructure shows that molDiscovery correctly identify six times more unique small molecules than previous methods.
The Cassini spacecraft's final orbits sampled Saturn's atmosphere and returned surprisingly complex mass spectra from the Ion and Neutral Mass Spectrometer (INMS). Signal returned from the instrument included native Saturn species, as expected, as well as a significant amount of signal attributed to vaporized ices and higher mass organics believed to be owing into Saturn's atmosphere from the rings. In this paper, we present an in-depth compositional analysis of the mass spectra returned from Cassini's last few orbits. We use a mass spectral deconvolution algorithm designed specifically to handle the complexities involved with unit resolution spaceflight mass spectrometry data to determine the relative abundance of species detected in the observations. We calculate the downward external flux and mass deposition rates of ring volatile species into Saturn's atmosphere and conclude that during these observations ring material was being deposited into Saturn's equatorial region at a rate on the order of 10(exp 4) kg/s.
The Cassini spacecraft's final orbits sampled Saturn's atmosphere and returned surprisingly complex mass spectra from the Ion and Neutral Mass Spectrometer (INMS). Signal returned from the instrument included native Saturn species, as expected, as well as a significant amount of signal attributed to vaporized ices and higher mass organics believed to be flowing into Saturn's atmosphere from the rings. In this paper, we present an in-depth compositional analysis of the mass spectra returned from Cassini's last few orbits. We use a mass spectral deconvolution algorithm designed specifically to handle the complexities involved with unit resolution spaceflight mass spectrometry data to determine the relative abundance of species detected in the observations. We calculate the downward external flux and mass deposition rates of ring volatile species into Saturn's atmosphere and conclude that during these observations ring material was being deposited into Saturn's equatorial region at a rate on the order of 10(exp 4) kg/s.
Many endophytes and rhizobacteria associated with plants support the growth and health of their hosts. The vast majority of these potentially beneficial bacteria have yet to be characterized, in part because of the cost of identifying bacterial isolates. Matrix-assisted laser desorption-time of flight (MALDI-TOF) has enabled culturomic studies of host-associated microbiomes but analysis of mass spectra generated from plant-associated bacteria requires optimization. In this study, we aligned mass spectra generated from endophytes and rhizobacteria isolated from heritage and sweet varieties of Zea mays. Multiple iterations of alignment attempts identified a set of parameters that sorted 114 isolates into 60 coherent MALDI-TOF taxonomic units (MTUs). These MTUs corresponded to strains with practically identical (>99%) 16S rRNA gene sequences. Mass spectra were used to train a machine learning algorithm that classified 100% of the isolates into 60 MTUs. These MTUs provided >70% coverage of aerobic, heterotrophic bacteria readily cultured with nutrient rich media from the maize microbiome and allowed prediction of the total diversity recoverable with that particular cultivation method. Acidovorax sp., Pseudomonas sp. and Cellulosimicrobium sp. dominated the library generated from the rhizoplane. Relative to the sweet variety, the heritage variety contained a high number of MTUs. The ability to detect these differences in libraries, suggests a rapid and inexpensive method of describing the diversity of bacteria cultured from the endosphere and rhizosphere of maize.
Introduction: Given the long time intervals required for data transmission to and from ocean worlds targets, low bandwidth for data transmission, time required for data processing and analysis, and potentially extreme radiation environments (e.g., Europa), it is clear that ocean worlds missions will need more autonomous flight instruments and software in order to achieve established science goals. Protracted time intervals for data analysis (e.g., Europa Lander) strongly motivates the development of rapid, consistent and streamlined methods for interpreting data from flight mass spectrometers to e.g., determine how mass spectra from a plume or surface liquid/ice relates to the surface/subsurface. Since mass spectrometry also has the potential to correctly identify biosignatures[1], it is imperative that such methods for interpreting data are consistent and accurate. We used 848 isotope ratio mass spectra from laboratory analyses of CO2 that interacted with ocean worlds-relevant seawaters as a ‘training’ dataset for ‘unsupervised’ machine learning. In unsupervised learning, characteristics of the data are not labeled or linked, and any similarities found only result from the neural network. CO2 isotopologues analyzed for this dataset mimic the remote measurements of CO2 by a flight mass spectrometer, and are detailed in Theiling [2]. From this dataset, we used measured features of the spectra, such as retention time, intensity, and (isotopologue) mass ratios as inputs for our autoencoder neural network. Our neural network was trained to find similarities in these and other spectral features for seawaters of a particular composition and amount of initial CO2. Successful training then created an output of these similarities for various seawaters, which included MgSO4, Na2SO4, NaCl, MgCl2, KCl, and NaHCO3, and combinations of these salts. We then applied dimensionality reduction techniques such as Principal Component Analysis (PCA), T-Distributed Stochastic Neighbor Embedding (TSNE), and Uniform Manifold Approximation and Projection (UMAP) to demonstrate latent data features as a two-dimensional projection in a unitless, high-dimensional space. In this projection, a data point represents the combined effect of spectral features such as intensity, retention time, and isotope ratio. Our initial UMAP demonstrates data clustering (organization of the data by the neural network) based on the amount of CO2 that had initially interacted with each seawater. Further training using more ‘supervised’ learning techniques demonstrate strong clustering of preliminary data based on initial CO2 concentration, seawater chemical composition, and ionic strength (salinity). Our preliminary work therefore suggests that machine learning has the potential to identify compositional variants of an ocean world seawater based on mass spectra from volatile CO2 measurements. Acknowledgments: This work was funded through a Strategic Task Group at NASA Goddard Space Flight Center. The training dataset was collected through funding from the Oklahoma Space Grant Consortium. References: [1] Pappalardo, R. et al. (2013) Astrobiology, 13, 740–773. [2] Theiling (2020) Icarus, 114216.
Generating top-down tandem mass spectra (MS/MS) for complex mixtures of proteoforms has become possible through improvements in fractionation, on-line separation, dissociation, and mass analysis. The algorithms to match tandem mass spectra to sequences have undergone a parallel evolution, with both spectral alignment and peak matching being paired with diverse methods for scoring proteoform-spectral matches (PrSMs). This study assesses state-of-the-art algorithms for top-down identification through three distinct challenges. The first is identifying a large yield of PrSMs while controlling false discovery rate (FDR) in identifying thousands of proteoforms from complex cell lysates via four software workflows: ProSight Proteome Discoverer, TopPIC, Informed Proteomics, and pTop. The second is the deconvolution of data from both Thermo Orbitrap-class and Bruker maXis Q-TOF instruments to produce consistent precursor charge and mass determinations while generating fragment mass lists to optimize identification. The third attempts to detect diverse post-translational modifications (PTMs) in proteoforms from cow milk and human ovarian tissue. The data demonstrate that existing software suites produce admirable sensitivity, in some cases identifying a third of collected tandem mass spectra with FDR controlled below 2%; the overlap in these PrSMs, however, illustrates real value in searching data with multiple search engines. Differences among identification workflows seem to result from each search algorithm incorporating its own deconvolution algorithm. By transmitting deconvolution data from multiple deconvolution routes (Thermo Xtract, Bruker Auto MSn, Mascot Distiller, TopFD, and FLASHDeconv) to the downstream TopPIC search algorithm, we were able to detect common causes of deconvolution disagreement. The detection of PTMs was very inconsistent among search algorithms, with some workflows suggesting as little as 1% of PrSMs from cow’s milk were singly-phosphorylated while other workflows found that 18% of PrSMs were singly-phosphorylated. Taken together, these results make a strong argument for top-down researchers to adopt a standard practice of analyzing each MS/MS experiment with at least two different search engines.
Knowledge of the chemical composition and mixing state of aerosols at a single-particle level is critical for gaining insights into atmospheric processes. One common tool to make these measurements is single-particle mass spectrometry. There remains a need to compare the performance of different single-particle mass spectrometers (SPMSs). An intercomparison of SPMSs was conducted at the Aerosol Interaction and Dynamics in the Atmosphere (AIDA) chamber at the Karlsruhe Institute of Technology (KIT) in November 2014, as part of the first phase of the Fifth International Workshop on Ice Nucleation (FIN-01). In this paper we compare size distributions and mass spectra of atmospherically relevant particle types measured by five SPMSs. These include different minerals, desert and soil dusts, soot, bioaerosol (Snomax; protein granule), secondary organic aerosol (SOA), and SOA-coated mineral particles. Most SPMSs reported similar vacuum aerodynamic diameter (d va ) within typical instrumental ranges from ~100–200 nm (lower limit) to ~2–3 µm (upper limit). In general, all SPMSs exhibited a wide dynamic range (up to ~10 3 ) and high signal-to-noise ratio (up to ~10 4 ) in mass spectra. Common spectral features with small diversities in mass spectra were found with high average Pearson's correlation coefficients, i.e., for average positive spectra r avg-pos =0.74 ± 0.12 and average negative spectra r avg-neg =0.67 ± 0.22. We found that instrument-specific detection efficiency (DE) was more dependent on particle size than particle type, and particle identification favored the use of bipolar, rather than monopolar, instruments. Particle classification from “blind experiments” showed that all instruments differentiated SOA, soot, and soil dust and detected subtle changes in the particle internal mixing but had difficulties differentiating among specific mineral types and dusts. This study helps to further understand the capabilities and limitations of the single-particle mass spectrometry technique in general and the specific performance of the instrument in characterizing atmospheric aerosol particles.
Matrix-assisted ionization (MAI) demonstrates high sensitivity for a variety of organic compounds; however, few studies have reported the application of MAI for the detection and characterization of inorganic analytes. Trace-level uranium analysis is important in the realms of nuclear forensics, nuclear safeguards, and environmental monitoring. Traditional mass spectrometry methods employed in these fields require combinations of extensive laboratory chemistry sample preparation and destructive ionization methods. There has been recent interest in exploring ambient mass spectrometry methods that enable timely sample analysis and higher sensitivity than what is attainable by field-portable radiation detectors. Rapid characterization of uranium at nanogram levels is demonstrated in this study using MAI techniques. Mass spectra were collected on an atmospheric pressure mass spectrometer for solutions of uranyl nitrate, uranyl chloride, uranyl acetate, and uranyl oxalate utilizing 3-nibrobenzonitrile as the ionization matrix. The uranyl complexes investigated were detectable, and the chemical speciation was preserved. Sample analysis was accomplished in a matter of seconds, and limits of detection of 5 ng of uranyl nitrate, 10 ng of uranyl oxalate, 100 ng of uranyl chloride, and 200 ng of uranyl acetate were achieved. The observed gas-phase speciation was similar to negative-ion electrospray ionization of uranyl compounds with notable differences. Six matrix-derived ions were detected in all negative-ion mass spectra, and some of these ions formed adducts with the uranyl analyte. Subsequent analysis of the matrix suggests that these molecules are not matrix contaminants and are instead created during the ionization process.
The present numerical model for neutral or charged dust-particle distribution prediction in P/Halley encompasses the spatial and temporal variations of the plasma parameters and magnetic field. A significant difference is noted between results for neutral dust trajectories and the trajectories of charged dust particles with radii smaller than 0.1 micron. While most of the model and in situ mass spectra were in good agreement, there is a shortage of the lowest-mass model particles, as well as an offset of the total counting rate for two outbound mass spectra. A combination of two Lorentzian particle mass-density functions with a 100:1 ratio for the number of particles with the lower and higher density functions yielded the best agreement.
The Hebrew University Cloud Model (HUCM) bin scheme and the Thompson bulk scheme in the Weather Research and Forecasting (WRF) model are compared to assess biases often found in simulated brightness temperature and radar reflectivity. Compared to our preceding study that evaluated several bulk schemes in the WRF model, the current study obtains a reduction of the bias from excessive microwave scattering by precipitation ice for both HUCM bin and the Thompson bulk microphysics schemes for a topographic winter precipitation event associated with an atmospheric river. The Thompson particle size distributions (PSDs) and snow particle density assumption are implemented into the Goddard Satellite Data Simulator Unit (G‐SDSU) and have produced improvements. Despite the greater sophistication of the bin scheme in representing cloud and precipitation processes, the simulation with the Thompson bulk scheme is generally in better agreement with observations for this winter event. The explicitly resolved hydrometeor PSDs in HUCM enable analysis of mass spectra variations in response to changes in microphysics assumptions. Two HUCM sensitivity runs tested the enhancement of snow particle breakup and the influence of ice nuclei (IN) concentration. Higher IN concentration resulted in increased snow mass and broadened the spectrum toward small‐size particles. Modified snow mass spectra and resultant changes in graupel contributed to modifications in scattering and reflectivity simulations. The article demonstrates the bin scheme's capability to provide a new means to improve our understanding of uncertainties in mesoscale weather models and radiative transfer models.
The design, development, manufacture, test and calibration of five lunar orbital mass spectrometers with the four associated ground support equipment test sets are discussed. A mass spectrometer was installed in the Apollo 15 and one in the Apollo 16 Scientific Instrument Module within the Service Module. The Apollo 15 mass spectrometer was operated with collection of 38 hours of mass spectra data during lunar orbit and 50 hours of data were collected during transearth coast. The Apollo 16 mass spectrometer was operated with collection of 76 hours of mass spectra data during lunar orbit. However, the Apollo 16 mass spectrometer was ejected into lunar orbit upon malfunction of spacecraft boom system just prior to transearth insection and no transearth coast data was possible.
The present invention discloses a mixed signal RF drive electronics board that offers small, low power, reliable, and customizable method for driving and generating mass spectra from a mass spectrometer, and for control of other functions such as electron ionizer, ion focusing, single-ion detection, multi-channel data accumulation and, if desired, front-end interfaces such as pumps, valves, heaters, and columns.