Search NASA⌕ Search

SEARCH · Search NASA

Results for “Maximum Mean Discrepancy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The Theory and Practice of Estimating the Accuracy of Dynamic Flight-Determined Coefficients

Means of assessing the accuracy of maximum likelihood parameter estimates obtained from dynamic flight data are discussed. The most commonly used analytical predictors of accuracy are derived and compared from both statistical and simplified geometrics standpoints. The accuracy predictions are evaluated with real and simulated data, with an emphasis on practical considerations, such as modeling error. Improved computations of the Cramer-Rao bound to correct large discrepancies due to colored noise and modeling error are presented. The corrected Cramer-Rao bound is shown to be the best available analytical predictor of accuracy, and several practical examples of the use of the Cramer-Rao bound are given. Engineering judgement, aided by such analytical tools, is the final arbiter of accuracy estimation.

Maine, R. E.↗

A correlative study of simultaneously measured He(++) fluxes in the solar wind and in the magnetosphere utilizing Imp-1 and 1971-089A satellite data

Simultaneously measured He(++) fluxes in the solar wind and in the magnetosphere were studied using data from the plasma spectrometer on the Imp I satellite and the energetic ion mass spectrometer on the low altitude polar orbiting satellite 1971-89A. A detailed comparison of the He(++) energy spectra measured simultaneously in the solar wind and in the low altitude dayside polar cusp on March 7, 1972 was made. The energy-per-unit-charge range of the energetic ion mass spectrometer on board the polar orbiting satellite was 700 eV to 12 keV. Within this range there was a clear maximum in the He(++) energy spectrum at approximately 1.5 keV/nucleon. There was not a clearly defined maximum in the H(+) spectrum, but the data were consistent with a peak between 0.7 and 1.0 keV/nucleon. Both spectra could be reasonably well fit with a convecting Maxwellian plus a high energy tail; however, the mean velocity for He(++) distribution was significantly greater than that for the H(+) distribution. The simultaneous solar wind measurements showed the mean velocities for both ion species to be approximately 600 km/sec. The discrepancies between the relative velocity distributions in the low altitude cusp and those in the solar wind are consistent with a potential difference of approximately 1.4 kV along their flow direction between the two points of observation.

Shelley, E. G.↗

Projected future daily characteristics of African precipitation based on global (CMIP5, CMIP6) and regional (CORDEX, CORDEX-CORE) climate models

In this work, we provide an assessment of future daily characteristics of African precipitation by explicitly comparing the results of large ensembles of global (CMIP5, CMIP6) and regional (CORDEX, CORE) climate models, specifically highlighting the similarities and inconsistencies between them. Results for seasonal mean precipitation are not always consistent amongst ensembles: in particular, global models tend to project a wetter future compared to regional models, especially over the Eastern Sahel, Central and East Africa. However, results for other precipitation characteristics are more consistent. In general, all ensembles project an increase in maximum precipitation intensity during the wet season over all regions and emission scenarios (except the West Sahel for CORE) and a decrease in precipitation frequency (under the Representative Concentration Pathways RCP8.5) especially over the West Sahel, the Atlas region, southern central Africa, East Africa and southern Africa. Depending on the season, the length of dry spells is projected to increase consistently by all ensembles and for most (if not all) models over southern Africa, the Ethiopian highlands and the Atlas region. Discrepancies exist between global and regional models on the projected change in precipitation characteristics over specific regions and seasons. For instance, over the Eastern Sahel in July–August most global models show an increase in precipitation frequency but regional models project a robust decrease. Global and regional models also project an opposite sign in the change of the length of dry spells. CORE results show a marked drying over the regions affected by the West Africa monsoon throughout the year, accompanied by a decrease in mean precipitation intensity between May and July that is not present in the other ensembles. This enhanced drying may be related to specific physical mechanisms that are better resolved by the higher resolution models and highlights the importance of a process-based evaluation of the mechanisms controlling precipitation over the region.

54 ENVIRONMENTAL SCIENCES↗

Quantification of beam complexity in intensity-modulated radiation therapy treatment plans

Purpose: Excessive complexity in intensity-modulated radiation therapy (IMRT) plans increases the dose uncertainty, prolongs the treatment time, and increases the susceptibility to changes in patient or target geometry. To date, the tools for quantitative assessment of IMRT beam complexity are still lacking. In this study, The authors have sought to develop metrics to characterize different aspects of beam complexity and investigate the beam complexity for IMRT plans of different disease sites. Methods: The authors evaluated the beam complexity scores for 65 step-and-shoot IMRT plans from three sites (prostate, head and neck, and spine) and 26 volumetric-modulated arc therapy (VMAT) plans for the prostate. On the basis of the beam apertures and monitor unit weights of all segments, the authors calculated the mean aperture area, extent of aperture shape irregularity, and degree of beam modulation for each beam. Then the beam complexity values were averaged to obtain the complexity metrics of the IMRT plans. The authors studied the correlation between the beam complexity metrics and the quality assurance (QA) results. Finally, the effects of treatment planning parameters on beam complexity were studied. Results: The beam complexity scores were not uniform among the prostate IMRT beams from different gantry angles. The lateral beams had larger monitor units and smaller shape irregularity, while the anterior-posterior beams had larger modulation values. On average, the prostate IMRT plans had the smallest aperture irregularity, beam modulation, and normalized monitor units; the head and neck IMRT plans had large beam irregularity and beam modulation; and the spine stereotactic radiation therapy plans often had small beam apertures, which may have been associated with the relatively large discrepancies between planned and QA measured doses. There were weak correlations between the beam complexity scores and the measured dose errors. The prostate VMAT beams showed greater complexity than the prostate step-and-shoot IMRT beams. In the treatment planning process, the beam complexity increased as the minimum segment area decreased and as the number of optimization iterations and the maximum number of segments increased. Conclusions: The proposed metrics were effective in characterizing the beam complexity of different disease sites and for different treatment modalities. Efforts should be made to reduce the unnecessary complexity of IMRT beams to minimize the radiation dose uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Dosimetric Effect of Zipper Artifacts on TomoTherapy Adaptive Dose Calculation-A Phantom Study

Tomotherapy adaptive dose calculation offers the ability to verify and adjust the therapeutic plan during the treatment. Using tomotherapy adaptive dose calculation, the planned fluence pattern can be used to recalculate the dose distribution on pretreatment megavoltage computed tomography (MVCT) images. Zipper artifacts, which appear as increased density in the central region of MVCT images, may affect the accuracy of adaptive dose recalculation. The purpose of this study was to evaluate the dosimetric effects of zipper artifacts on tomotherapy adaptive dose calculation. MVCT images of a cylindrical water phantom of 22-cm diameter were acquired on a tomotherapy system. The zipper artifacts were enclosed by a cylindrical planning target volume (PTV) contoured on these images. For comparison, artifact-free images were created by replacing the computed tomography (CT) numbers of zipper artifacts with the mean CT number of water. Treatment plans were generated by giving a uniform dose of 2 Gy to the PTV based on these modified images; it was then applied to the images that have the zipper artifacts. The impacts of different pitch ratios on the artifacts were assessed. The dose distribution differences between the 2 sets of images were compared. The absorbed dose that covered 95% volume of PTV and maximum dose, minimum dose, and mean dose of the PTV were also calculated and compared. The water phantom was scanned on the tomotherapy system twice per week for 12 consecutive weeks. The mean CT number of zipper artifacts (101 HU) was three times higher than that of water (34 HU). The CT number value and location of zipper artifacts were not affected by the pitch ratio. Gamma analysis was performed between the original and recalculated dose distributions. The discrepancies between the isodose distributions calculated by two sets of images were within 1%/1-mm tolerance. The dosimetric impact from zipper artifacts was found insignificant such that the recalculated dose was underestimated by less than 0.5%.

61 RADIATION PROTECTION AND DOSIMETRY↗

The 183-WSL Fast Rain Rate Retrieval Algorithm. Part II: Validation Using Ground Radar Measurements

The Water vapour Strong Lines at 183 GHz (183-WSL) algorithm is a method for the retrieval of rain rates and precipitation type classification (convectivestratiform), that makes use of the water vapor absorption lines centered at 183.31 GHz of the Advanced Microwave Sounding Unit module B (AMSU-B) and of the Microwave Humidity Sounder (MHS) flying on NOAA-15-18 and NOAA-19Metop-A satellite series, respectively. The characteristics of this algorithm were described in Part I of this paper together with comparisons against analogous precipitation products. The focus of Part II is the analysis of the performance of the 183-WSL technique based on surface radar measurements. The ground truth dataset consists of 2.5 years of rainfall intensity fields from the NIMROD European radar network which covers North-Western Europe. The investigation of the 183-WSL retrieval performance is based on a twofold approach: 1) the dichotomous statistic is used to evaluate the capabilities of the method to identify rain and no-rain clouds; 2) the accuracy statistic is applied to quantify the errors in the estimation of rain rates.The results reveal that the 183-WSL technique shows good skills in the detection of rainno-rain areas and in the quantification of rain rate intensities. The categorical analysis shows annual values of the POD, FAR and HK indices varying in the range 0.80-0.82, 0.330.36 and 0.39-0.46, respectively. The RMSE value is 2.8 millimeters per hour for the whole period despite an overestimation in the retrieved rain rates. Of note is the distribution of the 183-WSL monthly mean rain rate with respect to radar: the seasonal fluctuations of the average rainfalls measured by radar are reproduced by the 183-WSL. However, the retrieval method appears to suffer for the winter seasonal conditions especially when the soil is partially frozen and the surface emissivity drastically changes. This fact is verified observing the discrepancy distribution diagrams where2the 183-WSL performs better during the warm months, while during the winter time the discrepancies with radar measurements tends to maximum values. A stable behavior of the 183-WSL algorithm is demonstrated over the whole study period with an overall overestimation for rain rates intensities lower than 1 millimeter per hour. This threshold is crucial especially in wintertime where the low precipitation regime is difficult to be classified.

validationradar↗

Wall-Modeled Large-Eddy Simulations of a Swept Wing with Leading-Edge Ice

The aerodynamic performance of a swept wing derived from the Common Research Model wing with high-fidelity and smooth leading-edge ice shapes is evaluated using wall-modeled large-eddy simulations. Two mesh paradigms are considered within the Launch, Ascent, and Vehicle Aerodynamics framework: structured hybrid curvilinear body-fitted/immersed-boundary and unstructured Voronoi. The curvilinear approach models the effect of the ice on the flow through penalty terms and the Voronoi strategy includes the ice representation directly in the mesh.Aerodynamic loads, surface pressure profiles, and skin-friction streamlines are compared against experimental results collected at the Wichita State University wind tunnel at a Mach number of 0.18 and a Reynolds number per mean aerodynamic chord of 1.6 million. For the curvilinear simulations with high-fidelity ice, results are sensitive to spanwise mesh resolution near the leading edge, where insufficient spanwise resolution leads to a spanwise running vortexaft of the high-fidelity ice, which is partially removed with increasing spanwise resolution. For the Voronoi simulations with high-fidelity ice, refining the mesh led to good convergence towards the experimental results with the best case demonstrating a maximum discrepancy of three lift counts relative to the experiment across a range of angles of attack from about 5 to 24 degrees, validating the shrink-wrapping procedure used for the ice. For the smooth ice, the curvilinear approach consistently under-predicted the upper surface suction leading to an under-prediction in lift, but did not demonstrate the pronounced over-prediction in upper surface suction near the leading edge observed in the Voronoi simulations.

AATT↗

Variation in the Definition of Clinical Target Volumes for Pelvic Nodal Conformal Radiation Therapy for Prostate Cancer

Purpose: We conducted a comparative study of clinical target volume (CTV) definition of pelvic lymph nodes by multiple genitourinary (GU) radiation oncologists looking at the levels of discrepancies amongst this group. Methods and Materials: Pelvic computed tomography (CT) scans from 2 men were distributed to 14 Radiation Therapy Oncology Group GU radiation oncologists with instructions to define CTVs for the iliac and presacral lymph nodes. The CT data with contours were then returned for analysis. In addition, a questionnaire was completed that described the physicians' method for target volume definition. Results: Significant variation in the definition of the iliac and presacral CTVs was seen among the physicians. The minimum, maximum, mean (SD) iliac volumes (mL) were 81.8, 876.6, 337.6 {+-} 203 for case 1 and 60.3, 627.7, 251.8 {+-} 159.3 for case 2. The volume of 100% agreement was 30.6 and 17.4 for case 1 and 2 and the volume of the union of all contours was 1,012.0 and 807.4 for case 1 and 2, respectively. The overall agreement was judged to be moderate in both cases (kappa = 0.53 (p < 0.0001) and kappa = 0.48 (p < 0.0001). There was no volume of 100% agreement for either of the two presacral volumes. These variations were confirmed in the responses to the associated questionnaire. Conclusions: Significant disagreement exists in the definition of the CTV for pelvic nodal radiation therapy among GU radiation oncology specialists. A consensus needs to be developed so as to accurately assess the merit and safety of such treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Solar imaging vector magnetograph

This report describes an instrument which has been constructed at the University of Hawaii to make observations of the magnetic field in solar active regions. Detailed knowledge of active region magnetic structures is crucial to understanding many solar phenomena, because the magnetic field both defines the morphology of structures seen in the solar atmosphere and is the apparent energy source for solar flares. The new vector magnetograph was conceived in response to a perceived discrepancy between the capabilities of X ray imaging telescopes to be operating during the current solar maximum and those of existing magnetographs. There were no space-based magnetographs planned for this period; the existing ground-based instruments variously suffered from lack of sensitivity, poor time resolution, inadequate spatial resolution or unreliable sites. Yet the studies of flares and their relationship to the solar corona planned for the 1991-1994 maximum absolutely required high quality vector magnetic field measurements. By 'vector' measurements we mean that the observation attempts to deduce the complete strength and direction of the field at the measurement site, rather than just the line of sight component as obtained by a traditional longitudinal magnetograph. Knowledge of the vector field permits one to calculate photospheric electric currents, which might play a part in heating the corona, and to calculate energy stored in coronal magnetic fields as the result of such currents. Information about the strength and direction of magnetic fields in the solar atmosphere can be obtained in a number of ways, but quantitative data is best obtained by observing Zeeman-effect polarization in solar spectral lines. The technique requires measuring the complete state of polarization at one or more wavelengths within a magnetically sensitive line of the solar spectrum. This measurement must be done for each independent spatial point for which one wants magnetic field data. All the measurements need to be done in a time short compared to the time scale for changes of the solar features being observed. Were it possible, one would want to record all the needed data simultaneously, since temporal variation of atmospheric seeing degrades both the image and the polarization sensitivity. Since the measurements must span four dimensions, two spatial plus polarization and wavelength, we had some freedom to design the instrument to favor some dimensions over others in terms of simultaneity. Our earlier instrument, the Haleakala Stokes Polarimeter, records a range of wavelengths spanning two spectral lines in each reading, but requires two seconds to determine the polarization state and obtains spatial information only by assembling a long sequence of measurements at single locations on the sun. The new instrument sacrifices spectral detail and accuracy in favor of greatly improved imaging characteristics. The scientific goals for this instrument were to measure surface magnetic fields with enough accuracy to permit calculations of photospheric currents, but with a field of view covering an entire typical active region, high spatial resolution, and a fast enough temporal cadence for detecting flare-associated changes in magnetic structures.

Canfield, Richard C.↗

Calculation of electron and isotopes dose point kernels with fluka Monte Carlo code for dosimetry in nuclear medicine therapy

Purpose: The calculation of patient-specific dose distribution can be achieved by Monte Carlo simulations or by analytical methods. In this study, fluka Monte Carlo code has been considered for use in nuclear medicine dosimetry. Up to now, fluka has mainly been dedicated to other fields, namely high energy physics, radiation protection, and hadrontherapy. When first employing a Monte Carlo code for nuclear medicine dosimetry, its results concerning electron transport at energies typical of nuclear medicine applications need to be verified. This is commonly achieved by means of calculation of a representative parameter and comparison with reference data. Dose point kernel (DPK), quantifying the energy deposition all around a point isotropic source, is often the one. Methods: fluka DPKs have been calculated in both water and compact bone for monoenergetic electrons (10{sup -3} MeV) and for beta emitting isotopes commonly used for therapy ({sup 89}Sr, {sup 90}Y, {sup 131}I, {sup 153}Sm, {sup 177}Lu, {sup 186}Re, and {sup 188}Re). Point isotropic sources have been simulated at the center of a water (bone) sphere, and deposed energy has been tallied in concentric shells. fluka outcomes have been compared to penelope v.2008 results, calculated in this study as well. Moreover, in case of monoenergetic electrons in water, comparison with the data from the literature (etran, geant4, mcnpx) has been done. Maximum percentage differences within 0.8{center_dot}R{sub CSDA} and 0.9{center_dot}R{sub CSDA} for monoenergetic electrons (R{sub CSDA} being the continuous slowing down approximation range) and within 0.8{center_dot}X{sub 90} and 0.9{center_dot}X{sub 90} for isotopes (X{sub 90} being the radius of the sphere in which 90% of the emitted energy is absorbed) have been computed, together with the average percentage difference within 0.9{center_dot}R{sub CSDA} and 0.9{center_dot}X{sub 90} for electrons and isotopes, respectively. Results: Concerning monoenergetic electrons, within 0.8{center_dot}R{sub CSDA} (where 90%-97% of the particle energy is deposed), fluka and penelope agree mostly within 7%, except for 10 and 20 keV electrons (12% in water, 8.3% in bone). The discrepancies between fluka and the other codes are of the same order of magnitude than those observed when comparing the other codes among them, which can be referred to the different simulation algorithms. When considering the beta spectra, discrepancies notably reduce: within 0.9{center_dot}X{sub 90}, fluka and penelope differ for less than 1% in water and less than 2% in bone with any of the isotopes here considered. Complete data of fluka DPKs are given as Supplementary Material as a tool to perform dosimetry by analytical point kernel convolution. Conclusions: fluka provides reliable results when transporting electrons in the low energy range, proving to be an adequate tool for nuclear medicine dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Data Assimilation and Uncertainties in Early Solar Cycle Predictions

Stochastic nature of solar activity variations together with our limited knowledge of the dynamo mechanism and subsurface dynamics causes uncertainty in predictions of the solar cycle. For improving the physics-­‐based predictions we can take advantage of the mathematical data assimilation approach that allows us to take into account both, observational errors and model uncertainties, and provide estimates of the next solar cycle along with prediction uncertainties. In this study we use the Parker's migratory dynamo model together with the equation of magnetic helicity balance, which reproduces main properties of the sunspot cycles and allow us to minimize discrepancies between the observed global activity variations and the model solution. The test simulation runs show that a reliable prediction can be obtained for two phases of preceding solar cycle: 1) if the polar field reversals shortly after the solar maxima (strong toroidal field and weak poloidal field), and 2) during the solar minima (strongest poloidal and weak toroidal fields). The early estimate of Cycle 25 obtained by this method shows that this cycle will start in 2019 – 2020, reach the maximum in 2023 – 2024, and that the mean sunspot number at the maximum will be about 90 (for the v2.0 sunspot number series).

Data Assimilation↗

Poster — Thur Eve — 58: Dosimetric validation of electronic compensation for radiotherapy treatment planning

In this study we investigate the deliverability of dosimetric plans generated by the irregular surface compensator (ISCOMP) algorithm for 6 MV photon beams in Eclipse (Varian Medical System, CA). In contrast to physical tissue compensation, the electronic ISCOMP uses MLCs to dynamically modulate the fluence of a photon beam in order to deliver a uniform dose at a user defined plane in tissue. This method can be used to shield critical organs that are located within the treatment portal or improve dose uniformity by tissue compensation in inhomogeneous regions. Three site specific plans and a set of test fields were evaluated using the γ-metric of 3%/ 3 mm on Varian EPID, MapCHECK, and Gafchromic EBT3 film with a clinical tolerance of >95% passing rates. Point dose measurements with an NRCC calibrated ionization chamber were also performed to verify the absolute dose delivered. In all cases the MapCHECK measured plans met the gamma criteria. The mean passing rate for the six EBT3 film field measurements was 96.2%, with only two fields at 93.4 and 94.0% passing rates. The EPID plans passed for fields encompassing the central ∼10 × 10 cm{sup 2} region of the detector; however for larger fields and greater off-axis distances discrepancies were observed and attributed to the profile corrections and modeling of backscatter in the portal dose calculation. The magnitude of the average percentage difference for 21 ion chamber point dose measurements and 17 different fields was 1.4 ± 0.9%, and the maximum percentage difference was −3.3%. These measurements qualify the algorithm for routine clinical use subject to the same pre-treatment patient specific QA as IMRT.

60 APPLIED LIFE SCIENCES↗

Absence of hindrance in a microscopic 12 C + 12 C fusion study

Studies of low-energy fusion of light nuclei are important in astrophysical modeling, with small variations in reaction rates having a large impact on nucleosynthesis yields. Due to the lack of experimental data at astrophysical energies, extrapolation and microscopic methods are needed to model fusion probabilities. To investigate deep sub-barrier 12 C+ 12 C fusion cross sections and establish trends for the S factor. Microscopic methods based on static Hartree-Fock and time-dependent Hartree-Fock (TDHF) mean-field theory are used to obtain 12 C+ 12 C ion-ion fusion potentials. Fusion cross sections and astrophysical S factors are then calculated using the incoming wave boundary condition method. Both density-constrained frozen Hartree-Fock (DCFHF) and density-constrained TDHF (DC-TDHF) predict a rising S factor at low energies, with DC-TDHF predicting a slight damping in the deep sub-barrier region (≈1 MeV). Comparison between DC-TDHF calculations and maximum experimental cross sections in the resonance peaks are good. However, the discrepancy in experimental low-energy results inhibits interpretation of the trend. Using the fully microscopic DCFHF and DC-TDHF methods, no S factor maximum is observed in the 12 C+ 12 C fusion reaction. In addition, no extreme sub-barrier hindrance is predicted at low energies. Furthermore, the development of a microscopic theory of fusion including resonance effects, as well as further experiments at lower energies must be done before the deep sub-barrier behavior of the reaction can be established.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

When and how to treat an IMRT patient on a second accelerator without replanning?

When a linear accelerator is unavailable for treatment, a clinical decision is imminent regarding whether a patient should be treated on a linear accelerator other than the machine the patient was scheduled on, or whether treatment should be postponed until the original Linac becomes available. This work investigates the feasibility of switching patients to different accelerators for intensity-modulated radiation therapy (IMRT). We have performed Monte Carlo simulations of photon beams from different Linac models and vendors. Prostate and head and neck (H&N) treatment plans for Siemens Primus, Primart, and Varian 21EX accelerators are studied in this work. Dose distributions for given plans are recalculated using different beam data with the same nominal energy from different Linacs. We have compared dose-volume histograms (DVHs) and the maximum, the minimum, and the mean doses to the target and critical structures because of switching accelerators. In the process of switching a treatment plan to a different accelerator, issues exist, including optimum penumbra compensation, dose distribution at the boundary of target and critical structures, and multileaf collimator (MLC) leaf-width effects, which need to be considered and verified with measurements. Our Monte Carlo simulation results confirm that, for the cases we tested, the dose received by 95% of the planning target volume differs by 0.2% to 1.5% between Siemens Primus and Varian 21EX Linacs. The discrepancy is within our clinical acceptance criteria of 3% for IMRT treatments. In making the final decision on whether to switch machines or not, the tumor control probabilities (TCPs) based on a linear-quadratic model are compared. Based on the analyses performed in this work, it is therapeutically more beneficial to switch a patient to a different machine than to postpone a treatment until the original machine is available, especially for fast-growing tumors such as H&N cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Part 1: Aspects of lithospheric evolution on Venus. Part 2: Thermal and collisional histories of chondrite parent bodies

The geological evolution of distinctly different kinds of solar system objects is addressed. Venus has been observed over the past decade by orbital radars on both American and Soviet spacecraft. These surface measurements provide clues to the structure and evolution of the lithosphere. The parent bodies of chondritic meteorites, thought to resemble asteroids, represent the other end of the size spectrum of terrestrial objects. Their early thermal and collisional histories may be constrained by the chemical and textural record preserved in meteorite samples. Impact craters on Venus have been observed by the Soviet Venera 15/16 spacecraft. A formalism is presented by which the size-frequency distribution of impact craters may be used to estimate upper bounds on the mean global rates of volcanic resurfacing and lithospheric recycling on that planet over the past several hundred million years. The impact crater density reported from Venera observations, if valid for the entire Venus surface, indicates a mean volcanic flux no greater than 2 cu km/y, corresponding to a maximum average rate of resurfacing of about 4 km/b.y. For the lowest estimated mean crater retention age of the surface of Venus imaged by Venera 15/16, the rate of lithospheric recycling on Venus does not exceed 1.5 sq km/y. Ordinary chondrite meteorites show textural and chemical patterns indicative of varying intensities of thermal metamorphism. The conventional onion-shell model, which envisions highly metamorphosed material in the core and less intensely heated rocks near the surface, predicts an inverse relation between peak temperature and cooking rate, but none has been observed. A metamorphosed-planetesimal model is devised to explain this discrepancy, whereby heating occurs in planetesimals a few kilometers in radius which then accrete to form 100-km-radius parent bodies. Cooling rates are then randomly controlled by burial depth. Thermal and collisional constraints are examined, and the model is found to be applicable only to highly insulating Al-26-rich planetesimals that remain closely aggregated upon accretion. An alternative model is presented, in which onion-shell parent bodies are collisionally fragmented during metamorphism and then gravitationally reassembled. If reassembly times are short, then cooling rates would be determined by burial depth in the reaccreted parent body. This model, unlike previous ones, can explain both coherent and incoherent cooling of Breccia clasts by collisions during or after metamorphism, respectively.

Grimm, Robert E.↗

Two-dimensional profile measurement of plasma parameters in radio frequency-driven argon atmospheric pressure plasma jet

The two-dimensional profiles of the electron density, electron temperature, neutral translational temperature, and molecular rotational temperature are investigated in an argon atmospheric pressure plasma jet, which is driven by the radio frequency of 13.56 MHz by means of the laser scattering methods of Thomson, Rayleigh, and Raman. All measured parameters have maximum values at the center of the discharge and decrease toward the plasma edge. The results for the electron temperature profile are contrary to the results for the microwave-driven plasma. From our experimental results, the profiles of the plasma parameters arise from the radial contraction of plasmas and the time averaged profile of the electric field, which is obtained by a microwave simulation performed under identical conditions to the plasma jet. In the case of the neutral temperature, a higher translational temperature than the rotational temperature is measured, and its discrepancy is tentatively explained in terms of the low ion-neutral charge exchange rate and the additional degrees of freedom of the molecules. The description of our experimental results and the underlying physics are addressed in detail.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DARK AND LUMINOUS MATTER IN THINGS DWARF GALAXIES

We present mass models for the dark matter component of seven dwarf galaxies taken from 'The H I Nearby Galaxy Survey' (THINGS) and compare these with those taken from numerical {Lambda} cold dark matter ({Lambda}CDM) simulations. The THINGS high-resolution data significantly reduce observational uncertainties and thus allow us to derive accurate dark matter distributions in these systems. We here use the bulk velocity fields when deriving the rotation curves of the galaxies. Compared to other types of velocity fields, the bulk velocity field minimizes the effect of small-scale random motions more effectively and traces the underlying kinematics of a galaxy more properly. The 'Spitzer Infrared Nearby Galaxies Survey' 3.6 {mu}m and ancillary optical data are used for separating the baryons from their total matter content in the galaxies. The sample dwarf galaxies are found to be dark matter dominated over most radii. The relation between total baryonic (stars + gas) mass and maximum rotation velocity of the galaxies is roughly consistent with the baryonic Tully-Fisher relation calibrated from a larger sample of gas-dominated low-mass galaxies. We find discrepancies between the derived dark matter distributions of the galaxies and those of {Lambda}CDM simulations, even after corrections for non-circular motions have been applied. The observed solid body-like rotation curves of the galaxies rise too slowly to reflect the cusp-like dark matter distribution in cold dark matter halos. Instead, they are better described by core-like models such as pseudo-isothermal halo models dominated by a central constant-density core. The mean value of the logarithmic inner slopes of the mass density profiles is {alpha} = -0.29 {+-} 0.07. They are significantly different from the steep slope of {approx} - 1.0 inferred from previous dark-matter-only simulations, and are more consistent with shallower slopes found in recent {Lambda}CDM simulations of dwarf galaxies in which the effects of baryonic feedback processes are included.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-179: Exploring Appropriate Offset Values for Pencil Beam and Monte Carlo Dose Optimization in Lung Stereotactic Body Radiotherapy Encompassing the Effects of Respiration and Tumor Location

Purpose: Exploring appropriate offset values in dose optimization with pencil beam (PB) algorithm to minimize dosimetric differences with plans calculated with Monte Carlo (MC) for lung cancer treatment with Stereotactic Body Radiotherapy (SBRT). Methods: 20 cases of Non-Small Cell Lung Cancer, treated with gated full motion range SBRT were selected. According to the proximity of the Gross Tumor Volume (GTV) to the chest wall, two groups are defined: peripherally located when GTV merges with the chest wall for at least 50% of the lesion diameter, and centrally located when the GTV is surrounded by lung tissue. Treatment plans were created on 4D average intensity projection (AIP) CT set with Brainlab iPlanDose 4.1.2 planning system. The D97 of PTV was normalized to 50Gy using the fast PB and compared with MC. The optimized plan was then recomputed over each 4D respiratory phase, and compared with MC using the same plan MU's. Results: The mean difference in the PB and MC D97 of the ITV was 10.5% (±0.8%) of the prescription dose (50Gy). PB algorithm showed 2.3–2.4% less overestimation to the D97 of the ITV, when comparing to MC, in the maximum exhalation phase than in the maximal inhalation phase. Significantly smaller dose difference between PB and MC is also shown in plans for peripheral lesions (7.7 ± 0.7%) versus for central lesions (12.7±0.8%) (p< 0.01). Conclusion: The dosimetric differences between PB and MC can be reasonably predicted depending on the location of lesion in the lung, and may be used as offset value in dose optimization with PB. Since the maximal exhalation phase demonstrates less dose discrepancy between the two algorithms than that in maximal inhalation phase, caution is suggested when the latter is included as a major phase portion in the respiration gated lung SBRT.

60 APPLIED LIFE SCIENCES↗