Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measure control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Installation effects on propeller wake/vortex induced structure-borne noise transmission

A laboratory-based test apparatus was employed to investigate the effects of power-plant placement, engine/nacelle mass installation, and wing-to-fuselage attachment methods on propeller-induced structure-borne noise (SBN) transmission levels and their effects on noise-control measures. Data are presented showing SBN transmission is insensitive to propeller spanwise placement, however some sensitivity is seen in propeller-to-wing spacing. Installation of an engine/nacelle mass and variation in wing-to-fuselage attachments have measurable influences on SBN transmission and control measures.

Unruh, J. F.↗

Thermal monitoring, measurement, and control system for a Volatile Condensable Materials (VCM) test apparatus

A thermal monitoring and control concept is described for a volatile condensable materials (VCM) test apparatus where electric resistance heaters are employed. The technique is computer based, but requires only proportioning ON/OFF relay control signals supplied through a programmable scanner and simple quadrac power controllers. System uniqueness is derived from automatic temperature measurements and the averaging of these measurements in discrete overlapping temperature zones. Overall control tolerance proves to be better than + or - 0.5 C from room ambient temperature to 150 C. Using precisely calibrated thermocouples, the method provides excellent temperature control of a small copper VCM heating plate at 125 + or - 0.2 C over a 24 hr test period. For purposes of unattended operation, the programmable computer/controller provides a continual data printout of system operation. Real time operator command is also provided for, as is automatic shutdown of the system and operator alarm in the event of malfunction.

Ives, R. E.↗

Controllability and observability measures for Craig-Bampton substructure representations

Measures of controllability and observability are derived for a Craig-Bampton substructure representation for which fixed interface modes and constraint modes are computed relative to control actuator locations. The measures facilitate modal ordering and act as an index of dynamic completeness for modal truncation. Example problems are given to demonstrate that the controllable and observable reduced substructure models have a greater accuracy in predicting closed loop pole locations, transfer functions and actuation commands than conventional normal mode models.

Triller, Michael J.↗

Insitu measurement and control of processing properties of composite resins in a production tool

An in situ measuring technique for use in automated composite processing and quality control is discussed. Frequency dependent electromagnetic sensors are used to measure processing parameters at four ply positions inside a thick section 192-ply graphite-epoxy composite during cure in an 8 x 4 in. autoclave. Viscosity measurements obtained using the sensors are compared with the viscosities calculated using the Loos-Springer cure process model. Good overall agreement is obtained. In a subsequent autoclave run, the output from the four sensors was used to control the autoclave temperature. Using the 'closed loop' sensor controlled autoclave temperature resulted in a more uniform and more rapid cure cycle.

Kranbuehl, D.↗

The measurement and control of helicopter blade modal response using blade-mounted accelerometers

The measurement of helicopter blade flapping, bending, and lag modal acceleration and displacement response using blade-mounted accelerometers is described. It is shown that knowledge of the blade mode shapes is sufficient to permit separation of the modal contributions to the accelerometer signals using matrix inversion. The application of the Mckillip (1985) filter to the identification of modal rate response is described. Finally, the design of flapping, bending, and lag mode controllers utilizing the conventional mesh plate is presented. The measurement technique is illustrated using flight test results obtained using a Black Hawk helicopter.

Ham, Norman D.↗

Structure-borne noise control for propeller aircraft

A laboratory test apparatus was developed which would allow the study and development of propeller wake/vortex-induced structure-borne interior noise control measures. Various methods of wing structural modification, including blocking masses, surface damping treatments, and tuned mechanical absorbers, were evaluated relative to reduced interior noise levels. Inboard wing fuel was found to act as an effective blocking mass. Wing panel add-on damping treatment in the form of a single, constrained layer was not an effective control measure, except in the area of the propeller wake. However, highly damped, tuned mechanical absorbers were found to be the most efficient structure-borne noise (SBN) control measure.

Unruh, James F.↗

Distributionally Robust Decentralized Volt-Var Control With Network Reconfiguration

Here, this paper presents a decentralized volt-var optimization (VVO) and network reconfiguration strategy to address the challenges arising from the growing integration of distributed energy resources, particularly photovoltaic (PV) generation units, in active distribution networks. To reconcile control measures with different time resolutions and empower local control centers to handle intermittency locally, the proposed approach leverages a two-stage distributionally robust optimization; decisions on slow-responding control measures and set points that link neighboring subnetworks are made in advance while considering all plausible distributions of uncertain PV outputs. We present a decomposition algorithm with an acceleration scheme for solving the proposed model. Numerical experiments on the IEEE 123 bus distribution system are given to demonstrate its outstanding out-of-sample performance and computational efficiency, which suggests that the proposed method can effectively localize uncertainty via risk-informed proactive timely decisions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On stochastic control and optimal measurement strategies

The control of stochastic dynamic systems is studied with particular emphasis on those which influence the quality or nature of the measurements which are made to effect control. Four main areas are discussed: (1) the meaning of stochastic optimality and the means by which dynamic programming may be applied to solve a combined control/measurement problem; (2) a technique by which it is possible to apply deterministic methods, specifically the minimum principle, to the study of stochastic problems; (3) the methods described are applied to linear systems with Gaussian disturbances to study the structure of the resulting control system; and (4) several applications are considered.

Kramer, L. C.↗

Measurement and Control of Free Calcium Inside Small Intact Cells

The use of dye to measure intracellular free calcium concentration was discussed. Difficulty in measuring the calcium is caused by two problems: the small amount of calcium available for testing, and the selectivity to bind calcium at 100 nanomolar excludes substances from entering the cell.

Tsien, R. Y.↗

Modular instrumentation system for real-time measurements and control on reciprocating engines

An instrumentation system was developed for reciprocating engines. Among the parameters measured are the indicated mean effective pressure, or theoretical work per cycle, and the mass fraction burn rate, a measure of the combustion rate in the cylinder. These computations are performed from measured cylinder pressure and crankshaft angle and are available in real time for the experimenter. A 100 or 200 consecutive-cycle sample is analyzed to reduce the effect of cyclic variations in the engine. Data are displayed in bargraph form, and the mean and standard deviation are computed. Other instruments are also described.

Rice, W. J.↗

General aviation fuel quality control

Quality control measures for aviation gasoline, and some of the differences between quality control on avgas and mogas are discussed. One thing to keep in mind is that with motor gasoline you can always pull off to the side of the road. It's not so easy to do in an airplane. Consequently, there are reasons for having the tight specifications and the tight quality control measures on avgas as compared to motor gasoline.

Poitz, H.↗

Static Stability and Control Characteristics of a 0.5-Scale Model of the Hughes GAR-11 Missile at Mach Numbers from 1.60 to 2.30

Normal forces, axial forces, pitching moments, and rolling moments on the model and hinge moments on each of the four control surfaces were measured. Control surfaces were deflected from -35 deg to 15 deg in various combinations to produce pitching, yawing, and rolling moments on the model over a range of angles of attack from -5 deg to 25 deg at roll angles from -135 deg to 45 deg.

Wong, Norman D.↗

Fluid Redistribution and Heart Rate in Humans During Whole-Body Tilting, G(z) Centrifugation, and Lower Body Negative Pressure

Gravity creates blood pressure gradients which redistribute body fluids towards the feet. Positive G(z) centrifugation and lower body negative pressure (LBNP) have been proposed to simulate these and other effects of gravity during long-term existence in microgravity. We hypothesized that the magnitude of upper-to-lower body fluid redistribution would increase according to the following order: short-arm centrifugation (SAC), long-arm centrifugation (LAC), head-up tilt (HUT), and LBNP. To test this hypothesis, we employed strain gauge plethysmography of the neck, thigh and calf during HUT and supine SAC and LAC up to lG(z) at the feet, and during supine LBNP to 100 mm Hg. Supine 100 mm Hg LBNP generates footward force and produces transmural blood pressures in the foot approximately equal to 1 G(z) (90 deg) HUT. Heart rate was measured via cardiotachometry. Control measurements were made while supine. SAC and LAC elicited similar increases in thigh volume at 1 G(z) (2.3 +/- 0.4 and 2.1 +/- 0.1%, respectively; mean +/- se, n greater than or equal to 7). At 100 mm Hg LBNP, thigh volume increased (3.4 +/- 0.3%) significantly more than during l G(z) centrifugation (p less than 0.05). Surprisingly, due to a paradoxical 0.6% reduction of thigh volume between 0.8 and 1.0 G(z) HUT, thigh volume was increased only 0.6 +/- 0.3% at 1 G(z) HUT. The calf demonstrated similar, although less definitive, responses to the various gravitational stimuli. Neck volume tended to decrease less during HUT than during the other stimuli. Heart rate increased similarly during HUT (18 +/- 2 beats/min) and LAC (12 +/- 2 beats/min), and exhibited still greater elevation during LBNP (29 +/- 4 beats/min), yet did not increase during SAC. These results suggest upright posture activates mechanisms that counteract footward fluid redistribution which are not activated during supine applications of simulated gravity. LAC more closely approximated effects of normal gravity (HUT) than LBNP. Therefore, when considering LBNP to simulate gravity, these findings support efforts to reduce the cardiovascular stress imposed by LBNP, while preserving the gravity-like force generated by LBNP.

Watenpaugh, D. E.↗

Dynamic response for thermal control and measurement and fast radiation thermometry

A preliminary evaluation was made by ORNL of a two-color ratio pyrometer (TCRP) for temperature control in the Modular Electromagnetic Levitation (MEL) experiment. A discussion was presented by Eric Spjut at the 1987 NASA Non-Contact Temperature Measurement Workshop (NASA Conf. Publ. 2503, pp. 182-213) in which he described the non-linear characteristics of the time response of TCPs. Researchers replicated his model and results and note that the non-linear response behavior is minimized for small temperature steps at high temperatures. They then used the predicted response in a model for a proportional or integral feedback controller and predicted the control characteristics for heating and cooling a 5-mm diameter sphere of niobium at high (1500 to 2750 K) temperatures. The analysis shows that for a slow (25-ms) time response for a commercial RCRP, overshoots of several hundred kelvins will result from a 100-K decrease in the setpoint, and temperature tracking errors of 14 to 45 K will occur for control temperature ramps of 1000K/s. For a fast (greater than 0.1 ms) time response, the overshoot and ramp response errors are largely eliminated.

Shepard, R. L.↗

Control response measurements of the Skyship-500 airship

An examination is conducted of the Skyship 500's dynamic response to control inputs from elevators, rudders, and throttles at zero, 25, and 40 kts indicated airspeed. Input frequency sweeps were made with pitch and turn controls at 25 and 40 kts, ranging in frequency from about 0.03 to 1.5 Hz. FFT data analysis was then applied to compute describing functions for each run. Frequency responses are noted to be very smooth, and comparisons between repeat runs indicate excellent agreement. Summary plots of the faired describing functions from each run form the core of the data presented. These data constitute a comprehensive and reliable data base on which to predicate future dynamic simulation mathematical models of small airship dynamic response.

Jex, H. R.↗

Research on measurement and control of helicopter rotor response using blade-mounted accelerometers 1990-91

Wind tunnel testing of the full-size Model 412/IBC rotor performed at the NASA Ames Research Center is described. The use of blade-mounted accelerometers is found to be feasible for estimating or measuring blade flapping, lagging, and bending accelerations, rates, and displacements. Application of the imaginary swash plate concept to IBC systems leads to useful filtering of the blade accelerometer signals while permitting the control of a four-bladed rotor using measurements from any three blades. Rotor state measurements in the rotating system can be transformed to the corresponding nonrotating rotor states using the IBC algorithm with its associated filtering properties.

Ham, Norman D.↗

A computer simulation approach to measurement of human control strategy

Human control strategy is measured through use of a psychologically-based computer simulation which reflects a broader theory of control behavior. The simulation is called the human operator performance emulator, or HOPE. HOPE was designed to emulate control learning in a one-dimensional preview tracking task and to measure control strategy in that setting. When given a numerical representation of a track and information about current position in relation to that track, HOPE generates positions for a stick controlling the cursor to be moved along the track. In other words, HOPE generates control stick behavior corresponding to that which might be used by a person learning preview tracking.

Green, J.↗

Improved temperature control for measuring the humidity dependence of aerosol optical properties

Aerosols impact climate and cloud formation by their ability to take up water, which leads to changes in their optical properties. To better characterize the interactions of aerosol with water vapor, a humidification section has been added to the Cavity Attenuation Phase-shift Spectrometry (CAPS) instrument. The CAPS is a diode based method that provides simultaneous measurements of both aerosol total optical extinction and scattering in real-time. We are improving the humidity controlled sample line with new temperature controls. The current system suffers from particlelosses and poorly controlled humidity profiles, both of which were corrected for in the systems redesign. This improved wet-CAPS system has been integrated with a dry-CAPS to simultaneously measure the wet and dry aerosol optical properties. The two CAPS monitors were operated in a dry collection mode to ensure there were no biases between the instruments. Initial calibrations and data were collected to test the functionality of the dual CAPS system (wet + dry). The new two channel CAPS system improves our ability to measure the effects of humidity on aerosol optical properties.