Search NASA⌕ Search

SEARCH · Search NASA

Results for “Medical Kit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

JSC Pharmacy Services for Remote Operations

The Johnson Space Center Pharmacy began operating in March of 2003. The pharmacy serves in two main capacities: to directly provide medications and services in support of the medical clinics at the Johnson Space Center, physician travel kits for NASA flight surgeon staff, and remote operations, such as the clinics in Devon Island, Star City and Moscow; and indirectly provide medications and services for the International Space Station and Space Shuttle medical kits. Process changes that occurred and continued to evolve in the advent of the installation of the new JSC Pharmacy, and the process of stocking medications for each of these aforementioned areas will be discussed. Methods: The incorporation of pharmacy involvement to provide services for remote operations and supplying medical kits was evaluated. The first step was to review the current processes and work the JSC Pharmacy into the existing system. The second step was to provide medications to these areas. Considerations for the timeline of expiring medications for shipment are reviewed with each request. The third step was the development of a process to provide accountability for the medications. Results: The JSC Pharmacy utilizes a pharmacy management system to document all medications leaving the pharmacy. Challenges inherent to providing medications to remote areas were encountered. A process has been designed to incorporate usage into the electronic medical record upon return of the information from these remote areas. This is an evolving program and several areas have been identified for further improvement.

Stoner, Paul S.↗

Stability of Dosage Forms in the Pharmaceutical Payload Aboard Space Missions

Efficacious pharmaceuticals with adequate shelf lives are essential for successful space medical operations. Stability of pharmaceuticals, therefore, is of paramount importance for assuring the health and wellness of astronauts on future space exploration missions. Unique physical and environmental factors of space missions may contribute to the instability of pharmaceuticals, e.g., radiation, humidity and temperature variations. Degradation of pharmaceutical formulations can result in inadequate efficacy and/or untoward toxic effects, which could compromise astronaut safety and health. Methods: Four identical pharmaceutical payload kits containing 31 medications in different dosage forms (liquid, tablet, capsule, ointment and suppository) were transported to the International Space Station aboard the Space Shuttle (STS-121). One of the 4 kits was stored on the Shuttle and the other 3 were stored on the International Space Station (ISS) for return to Earth at 6-month interval aboard a pre-designated Shuttle flight for each kit. The kit stored on the Shuttle was returned to Earth aboard STS-121 and 2 kits from ISS were returned on STS 117 and STS-122. Results: Analysis of standard physical and chemical parameters of degradation was completed for pharmaceuticals returned by STS-121 after14 days, STS - 117 after11 months and STS 122 after 19 months storage aboard ISS. Analysis of all flight samples along with ground-based matching controls was completed and results were compiled. Conclusion: Evaluation of results from the shuttle (1) and ISS increments (2) indicate that the number of formulations degraded in space increased with duration of storage in space and was higher in space compared to their ground-based counterparts. Rate of degradation for some of the formulations tested was faster in space than on Earth. Additionally, some of the formulations included in the medical kits were unstable, more so in space than on the ground. These results indicate that the space flight environment may adversely affect the shelf life of pharmaceuticals aboard space missions.

Du, Brian J.↗

Are Medications Involved in Vision and intracranial Pressure Changes Seen in Spaceflight?

Some crewmembers have experienced changes in their vision after long-duration spaceflight on the ISS. These impairments include visual performance decrements, development of cotton-wool spots or choroidal folds, optic-disc edema, optic nerve sheath distention, and/or posterior globe flattening with varying degrees of severity and permanence. These changes are now used to define the visual impairment/intracranial pressure (VIIP) syndrome. The reasons for these potentially debilitating medical issues are currently unknown. The potential role of administered medications has not yet been examined, but it is known that many medications can have side effects that are similar to VIIP symptoms. Some medications raise blood pressure, which can affect intracranial pressure. Many medications that act in the central nervous system can affect intracranial pressures and/or vision. About 40% of the medications in the ISS kit are known to cause side effects involving changes in blood pressure, intracranial pressure and/or vision. For this reason, we proposed an investigation of the potential relationship between ISS medications and their risk of causing or exacerbating VIIP-like symptoms. The purpose of this study was to use medication usage records for affected and unaffected crew to determine if use of particular medications seemed to correlate with VIIP occurrence or severity.

Wotring, V. E.↗

Are Medications Involved in Vision and Intracranial Pressure Changes Seen in Spaceflight?

Some crewmembers have experienced changes in their vision after long-duration spaceflight on the ISS. These impairments include visual performance decrements, development of cotton-wool spots or choroidal folds, optic-disc edema, optic nerve sheath distention, and/or posterior globe flattening with varying degrees of severity and permanence. These changes are now used to define the visual impairment/intracranial pressure (VIIP) syndrome. It is known that many medications can have side effects that are similar to VIIP symptoms. Some medications raise blood pressure, which can affect intracranial pressure. Many medications that act in the central nervous system can affect intracranial pressures and/or vision. About 40% of the medications in the ISS kit are known to cause side effects involving changes in blood pressure, intracranial pressure and/or vision. For this reason, we have begun an investigation of the potential relationship between ISS medications and their risk of causing or exacerbating VIIP-like symptoms.

Wotring, V. E.↗

SHF: Symmetrical Hierarchical Forest with Pretrained Vision Transformer Encoder for High-Resolution Medical Segmentation

This paper presents a novel approach to addressing the long-sequence problem in high-resolution medical images for Vision Transformers (ViTs). Using smaller patches as tokens can enhance ViT performance, but quadratically increases computation and memory requirements. Therefore, the common practice for applying ViTs to high-resolution images is either to: (a) employ complex sub-quadratic attention schemes or (b) use large to medium-sized patches and rely on additional mechanisms within the model to capture the spatial hierarchy of details. We propose Symmetrical Hierarchical Forest (SHF), a lightweight approach that adaptively patches the input image to increase token information density and encode hierarchical spatial structures into the input embedding. We then apply a reverse depatching scheme to the output embeddings of the transformer encoder, eliminating the need for convolution-based decoders. Unlike previous methods that modify attention mechanisms or use a complex hierarchy of interacting models, SHF can be retrofitted to any ViT model to allow it to learn the hierarchical structure of details in high-resolution images without requiring architectural changes. Experimental results demonstrate significant gains in computational efficiency and performance: on the PAIP WSI dataset, we achieved a 3∼32×speedup or a 2.95%∼7.03% increase in accuracy (measured by Dice score) at a 64K2 resolution with the same computational budget, compared to state-of-the-art production models. On the 3D medical datasets BTCV and KiTS, training was 6×faster, with accuracy gains of 6.93% and 5.9%, respectively, compared to models without SHF.

Zhang, Enzhi [Hokkaido University, Japan]↗

Information Technology: A Tool to Cut Health Care Costs

Old Dominion University embarked on a project to see how current computer technology could be applied to reduce the cost and or to improve the efficiency of health care services. We designed and built a prototype for an integrated medical record system (MRS). The MRS is written in Tool control language/Tool kit (Tcl/Tk). While the initial version of the prototype had patient information hard coded into the system, later versions used an INGRES database for storing patient information. Currently, we have proposed an object-oriented model for implementing MRS. These projects involve developing information systems for physicians and medical researchers to enhance their ability for improved treatment at reduced costs. The move to computerized patient records is well underway, several standards exist for laboratory records, and several groups are working on standards for other portions of the patient record.

Mukkamala, Ravi↗

Shuttle Orbiter medical system equipment/supplies evaluation

The effectivity was evaluated in zero gravity of several medical equipment and supply items flown in the Shuttle Orbiter Medical System (SOMS). Several procedures listed in Medical Operations Medical Checklist, JSC 1732 were also evaluated. Several items were drawn out of the kits and tested on the KC-135. In two different flights, the following elements were examined: (1) measuring IV flow (drip chamber, one way flow valve, and air/fluid separator); (2) chemstrip protocol for urine analysis in zero-gravity; and (3) tamper resistant seals for injectable medications.

Maidlow, Kristin↗

Assessing the reliability of medical resource demand models in the context of COVID-19

Abstract Background Numerous medical resource demand models have been created as tools for governments or hospitals, aiming to predict the need for crucial resources like ventilators, hospital beds, personal protective equipment (PPE), and diagnostic kits during crises such as the COVID-19 pandemic. However, the reliability of these demand models remains uncertain. Methods Demand models typically consist of two main components: hospital use epidemiological models that predict hospitalizations or daily admissions, and a demand calculator that translates the outputs of the epidemiological model into predictions for resource usage. We conducted separate analyses to evaluate each of these components. In the first analysis, we validated various hospital use epidemiological models using a recent validation framework designed for epidemiological models. This allowed us to quantify the accuracy of the models in predicting critical aspects such as the date and magnitude of local COVID-19 peaks, among other factors. In the second analysis, we evaluated a range of demand calculators for ventilators, medical gowns, and COVID-19 test kits. To achieve this, we decoupled these demand calculators from the underlying epidemiological models and provided ground truth data for their inputs. This approach enabled a direct comparison of the demand calculators, comparing them against each other and actual usage data when available. The code is available athttps://doi.org/10.5281/zenodo.13712387. Results Performance varied greatly across the epidemiological models, with greater variability in COVID-19 hospital use predictions than for COVID-19 deaths as analyzed previously. Some models did not have any peaks. Among those that did, the models under-estimated date of peak approximately as often as they over-estimated, but were more likely to under-estimate magnitude of peak, with typical relative errors around 50%. Regarding demand calculator predictions, there was significant variability, including five-fold differences in predictions for gown models. Validation against actual or surrogate usage data illustrated the potential value of demand models while demonstrating their limitations. Conclusions The emerging field of demand modeling holds promise in averting medical resource shortages during future public health emergencies. However, achieving this potential necessitates focused efforts on standardization, transparency, and rigorous model validation before placing reliance on demand models in critical public health decision-making.

Medical Informatics↗

Biomedical support systems

Biomedical support hardware for SMEAT consisted basically of two systems, the inflight medical support system, and the operational bioinstrumentation system. The former is essentially a diagnostic and therapeutic kit; the latter is a belt equipped with sensors worn by the crewman to permit monitoring of his vital signs. Special attention was given during to the use and verification of the items in the systems so that changes required in the equipment could be pinpointed and effected prior to the Skylab mission. During the in-chamber testing, evaluations were made of the effectiveness of the proposed microbiology procedures, techniques, equipment, and the stability of media and reagents over the extended period of storage.

Brockett, R. M.↗

Automatic Sprout Grower

Self-contained seed-sprouting system provides environment for sprouting seeds quickly and easily. Sprouting container standard 6-oz package for dehydrated food and drink mixes in Space Shuttle. About 4 g of dry alfalfa or radish seeds vacuum-sealed in each cup, like freeze-dried foods. Sixteen cups suspended in tray. Air-and-water inlet tube links each cup to system of tubes and solenoid valves alternately furnish air and water and remove stale air. Peristaltic pump supplies water from vinyl medical-fluid bag. Small diaphragm pump supplies and exhausts air. Small circuit board times movements of air and water. Kit offers advantages to home gardeners. Apartment dwellers use it for steady production of homegrown sprouts even though they have no garden space.

Sauer, Richard L.↗

Pharmacovigilance in Space: Stability Payload Compliance Procedures

Pharmacovigilance is the science of, and activities relating to the detection, assessment, understanding, and prevention of drug-related problems. Over the lase decade, pharmacovigilance activities have contributed to the development of numerous technological and conventional advances focused on medication safety and regulatory intervention. The topics discussed include: 1) Proactive Pharmacovigilance; 2) A New Frontier; 3) Research Activities; 4) Project Purpose; 5) Methods; 6) Flight Stability Kit Components; 7) Experimental Conditions; 8) Research Project Logistics; 9) Research Plan; 10) Pharmaceutical Stability Research Project Pharmacovigilance Aspects; 11) Security / Control; 12) Packaging/Containment Actions; 13) Shelf-Life Assessments; 14) Stability Assessment Parameters; 15) Chemical Content Analysis; 16) Preliminary Results; 17) Temperature/Humidity; 18) Changes in PHysical and Chemical Assessment Parameters; 19) Observations; and 20) Conclusions.

Daniels, Vernie R.↗

Shuttle freezer conceptual design

A conceptual design for a kit freezer for operation onboard shuttle was developed. The freezer features a self-contained unit which can be mounted in the orbiter crew compartment and is capable of storing food at launch and returning with medical samples. Packaging schemes were investigated to provide the optimum storage capacity with a minimum weight and volume penalty. Several types of refrigeration systems were evaluated to select one which would offer the most efficient performance and lowest hazard of safety to the crew. Detailed performance data on the selected, Stirling cycle principled refrigeration unit were developed to validate the feasibility of its application to this freezer. Thermal analyses were performed to determine the adequacy of the thermal insulation to maintain the desired storage temperature with the design cooling capacity. Stress analyses were made to insure the design structure integrity could be maintained over the shuttle flight regime. A proposed prototype freezer development plan is presented.

Proctor, B. W.↗

Antimicrobial Medication Stability During Space Flight

The current vision for manned space flight involves lunar and Martian exploration within the next two decades. In order for NASA to achieve these goals, a significant amount of preparation is necessary to assure crew health and safety. A mission critical component of this vision centers around the stability of pharmaceutical preparations contained in the space medicine kits. Evidence suggests that even brief periods of space flight have significant detrimental effects for some pharmaceutical formulations. The effects observed include decreases in physical stability of drug formulations of sufficient magnitude to effect bioavailability. Other formulations exhibit decreases in chemical stability resulting in a loss of potency. Physical or-chemical instability of pharmaceutical formulations i n space medicine kits could render the products ineffective. Of additional concern is the potential for formation of toxic degradation products as a result of the observed product instability. This proposal addresses Question number 11 of Clinical Capabilities in the Critical Path Roadmap. In addition, this proposal will reduce the risks and/or enhance the capabilities of humans exposed to the environments of space flight or an extraterrestrial destination by identifying drugs that may be unstable during spaceflight.

Putcha, Lakshmi↗

Shuttle Kit Freezer Refrigeration Unit Conceptual Design

The refrigerated food/medical sample storage compartment as a kit to the space shuttle orbiter is examined. To maintain the -10 F in the freezer kit, an active refrigeration unit is required, and an air cooled Stirling Cycle refrigerator was selected. The freezer kit contains two subsystems, the refrigeration unit, and the storage volume. The freezer must provide two basic capabilities in one unit. One requirement is to store 215 lbs of food which is consumed in a 30-day period by 7 people. The other requirement is to store 128.3 lbs of medical samples consisting of both urine and feces. The unit can be mounted on the lower deck of the shuttle cabin, and will occupy four standard payload module compartments on the forward bulkhead. The freezer contains four storage compartments.

Copeland, R. J.↗

Surgical Instrument Restraint in Weightlessness

Performing a surgical procedure during spaceflight will become more likely with longer duration missions in the near future. Minimal surgical capability has been present on previous missions as the definitive medical care time was short and the likelihood of surgical events too low to justify surgical hardware availability. Early demonstrations of surgical procedures in the weightlessness of parabolic flight indicated the need for careful logistical planning and restraint of surgical hardware. The consideration of human ergonomics also has more impact in weightlessness than in the conventionall-g environment. Three methods of surgical instrument restraint - a Minor Surgical Kit (MSK), a Surgical Restraint Scrub Suit (SRSS), and a Surgical Tray (ST) were evaluated in parabolic flight surgical procedures. The Minor Surgical Kit was easily stored, easily deployed, and demonstrated the best ability to facilitate a surgical procedure in weightlessness. Important factors in this surgical restraint system include excellent organization of supplies, ability to maintain sterility, accessibility while providing secure restraint, ability to dispose of sharp items and biological trash, and ergonomical efficiency.

Campbell, Mark R.↗

In-flight medical support system

The In-flight Medical Support System for Skylab was designed to provide the onboard Crew Physician or Scientist Pilot (or other crewmember if the Scientist Pilot was unable to act) with information adequate to make diagnostic assessment of those injuries or illnesses most likely to occur in the Skylab environment. The necessary diagnostic, therapeutic, and laboratory equipment needed to diagnose and to render first aid, resuscitative or supportive measures was stored in the Skylab Orbital Workshop. The resupply kit containing refrigerated laboratory and drug resupply items was stored in the Command Module.

Chassay, C.↗

Emergency medicine and the airline passenger

Problems related to immediate medical care in case of in-flight emergencies are discussed with reference to such critical types of medical emergencies as obstructed airway, cardiac dysfunction, trauma, hemorrhage, hypoxia, and pain. It is shown that training flight attendants to deal with in-flight medical emergencies and to use first-aid support equipment and essential and useful drugs may later help with stabilization of a victim and allow continuing the flight to the scheduled destination without the need for a diverted landing. Among the steps suggested in order to upgrade inflight welfare and safety of passengers are the development of an advisory circular by the FAA covering standardized training for flight attendants, regulatory action requiring upgrading of the present rudimentary first-aid kit, and the enactment of Good Samaritan legislation by the U.S. Government.

Mohler, S. R.↗

Fibroblast Growth Factor-23 in Bed Rest and Spaceflight

Many nutritional factors influence bone, from the basics of calcium and vitamin D, to factors which influence bone through acid/base balance, including protein, sodium, and more. Fibroblast growth factor 23 (FGF23) is a recently identified factor, secreted from osteocytes, which is involved in classic (albeit complex) feedback loops controlling phosphorus homeostasis through both vitamin D and parathyroid hormone (PTH) (1, 2). As osteocytes are gravity sensing cells, it is important to determine if there are changes in FGF23 during spaceflight. In extreme cases, such as chronic kidney disease, FGF23 levels are highly elevated. FGF23 imbalances, secondary to dietary influences, may contribute to skeletal demineralization and kidney stone risk during spaceflight. Presented with an imbalanced dietary phosphorus to calcium ratio, increased secretion of FGF23 will inhibit renal phosphorus reabsorption, resulting in increased excretion and reduced circulating phosphorus. Increased intake and excretion of phosphorus is associated with increased kidney stone risk in both the terrestrial and microgravity environments. Highly processed foods and carbonated beverages are associated with higher phosphorus content. Ideally, the dietary calcium to phosphorus ratio should be at minimum 1:1. Nutritional requirements for spaceflight suggest that this ratio not be less than 0.67 (3), while the International Space Station (ISS) menu provides 1020 mg Ca and 1856 mg P, for a ratio of 0.55 (3). Subjects in NASA's bed rest studies, by design, have consumed intake ratios much closer to 1.0 (4). FGF23 also has an inhibitory influence on PTH secretion and 1(alpha)-hydroxylase, both of which are required for activating vitamin D with the conversion of 25-hydroxyvitamin D to 1,25-dihydroxyvitamin D. Decreased 1,25-dihydroxyvitamin D will result in decreased intestinal phosphorus absorption, and increased urinary phosphorus excretion (via decreased renal reabsorption). Should a decrease in 1,25- dihydroxyvitamin D be necessary to reduce intestinal phosphorus absorption, calcium absorption will also proportionally be reduced, potentially leading to skeletal demineralization. Demineralization of bone can increase kidney stone risk, a medical issue that could prove detrimental to mission success. Given the interrelationships described above, we sought to determine circulating FGF23 concentrations in spaceflight and ground analog studies to better understand the potential effects of dietary phosphorus on bone and calcium metabolism. We analyzed serum from ISS astronauts participating in studies of bone biochemistry, including the Nutrition SMO and Pro K experiments, and we also evaluated FGF23 during extended-duration bed rest. Serum intact FGF23 levels were determined using an ELISA kit from Kainos laboratories in Japan. While initial evaluation of the data showed no changes over time during flight or bed rest, evaluation continues of FGF23 data in light of dietary factors, PTH, vitamin D status, and other biochemical and endocrine factors.

Bokhari, R.↗