Search NASASearch

SEARCH · Search NASA

Results for “Metering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Strategic Surface Metering at Charlotte Douglas International Airport

NASA is conducting a field test of the Airspace Technology Demonstration2 (ATD-2) to evaluate an Integrated Arrival, Departure, and Surface (IADS) traffic management system. The IADS system was deployed to Charlotte Douglas International Airport (CLT) in 2017 for a three-year field evaluation. The Phase 1 field evaluation included tactical surface metering, which manages departure excess taxi time by tactically assigning gate holds. Phase 2 built upon the lessons learned from Phase 1 to extend surface metering into the strategic metering timeframes. In this paper, we describe the strategic metering capabilities of the ATD-2 IADS system and the operational results from CLT.

Airspace Technology Demonstration 2

Design, fabrication, and test of a Graphite/Epoxy Metering Shell (GEMS)

A program to design, fabricate and test a dimensionally stable metering structure in support of the large space telescope (LST) program is discussed. Graphite/epoxy was the material selected as the only viable candidate material which can meet the stringent thermal expansion criteria of the LST. A metering shell was designed and fabricated, with emphasis on dimensional stability in conjunction with low cost. Thermal expansion test coupons extracted from the layups of the skin panels indicated the attainment of a coefficient of thermal expansion of 0.0666 micrometers/m K. Subsequent thermal vacuum chamber tests on the complete metering shell demonstrated an expansion of the 2.95-meter overall length of 0.27 micrometers/K. Static and dynamics tests, which demonstrated adequacy with respect to limit loads and stiffness, were also accomplished.

Source record

A 15-meter deployable aperture microwave radiometer

The Large Antenna Multifrequency Microwave Radiometer (LAMMR) was a 4-meter-diameter mechanically scanned (at 1 rps) antenna operating at frequencies from 4.3 to 36 GHz. This LAMMR system was scheduled to fly on the National Oceanic Satellite System (NOSS) in 1986 to measure sea surface temperature and wind speed along with several other atmospheric and sea ice parameters. The LAMMR was limited to a 4-meter solid reflector to stay within the Shuttle/NOSS launch volume and to operate with radiometric precision up to 36.5 GHz. Under the 4-meter aperture constraint, LAMMR could not meet the user resolution requirement for sea surface temperature (25 km minimum, 50 km goal) in an RFI free band, i.e., 4.3 GHz. This study explores the feasibility of meeting this requirement goal with a 15-meter mechanically scanned deployable reflector. Two other research objectives can also be studied by adding one active (approximately 5 GHz) and two additional passive (1.4 and 6.4 GHz) channels to investigate soil moisture and precipitation profiles over land. These two objectives are closely related because the precipitation is the source of the soil moisture in unirrigated regions, and the soil moisture changes between samples (2/day) could indicate that precipitation may have occurred while the sensor was not in view.

Coyner, J. V., Jr.

NASTRAN Structural Model for the Large 64-meter Antenna Pedestal. Part 3: Applications to Hydrostatic Bearing Oil Film

Investigations are conducted on the 64-meter antenna hydrostatic bearing oil film thickness under a variety of loads and elastic moduli. These parametric studies use a NASTRAN pedestal structural model to determine the deflections under the hydrostatic bearing pad. The deflections form the input for a computer program to determine the hydrostatic bearing oil film thickness. For the future 64-meter to 70-meter antenna extension and for the 2.2-meter (86-in.) haunch concrete replacement cases, safe oil film thickness (greater than 0.13 mm (0.005 in.) at the corners of the pad) are predicted. The effects of varying moduli of elasticity for different sections of the pedestal and the film height under distressed runner conditions are also studied.

Chian, C. T.

Advanced smoke meter development survey and analysis

Ideal smoke meter characteristics are determined to provide a basis for evaluation of candidate systems. Five promising techniques are analyzed in detail to evaluate compilance with the practical smoke meter requirements. Four of the smoke measurement concepts are optical methods: Modulated Transmission (MODTRAN), Cross Beam Absorption Counter (CBAC), Laser Induced Incandescence (LIN), and Photoacoustic Spectroscopy (PAS). A rapid response filter instrument called a Taper Element Oscillating Microbalance (TEOM) is also evaluated. For each technique, the theoretical principles are described, the expected performance is determined, and the advantages and disadvantages are discussed The expected performance is evaluated against each of the smoke meter specifications, and the key questions for further study are given. The most promising smoke meter technique analyzed was MODTRAN, which is a variation on a direct transmission measurement. The soot-laden gas is passed through a transmission cell, and the gas pressure is modulated by a speaker.

Pitz, R. W.

The development of the 15-Meter Hoop Column deployable antenna system with structural and electromagnetic performance results

This paper presents the technical results obtained during the development and engineering tests of a 15-Meter Hoop Column deployable antenna system. An important element of the 15-meter antenna program was the structural tests and the characterization of the surface accuracy of the deployed mesh surface. The overall system performance of the 15-meter antenna was obtained during radio frequency tests conducted in the Martin Marietta Near Field Test Laboratory in Denver, CO. The near field tests verified the electromagnetic performance of the structure which exhibited a surface accuracy of 0.061 in (RMS). Radio frequency tests were conducted at 2.3, 4.3, 7.7, and 11.6 GHz. The experiment and analytical results obtained through the 15-meter antenna program will provide new opportunities for the application of large space antennas for future missions.

Campbell, T. G.

Development of the 15 meter diameter hoop column antenna

The building of a deployable 15-meter engineering model of the 100 meter antenna based on the point-design of an earlier task of this contract, complete with an RF-capable surface is described. The 15 meter diameter was selected so that the model could be tested in existing manufacturing, near-field RF, thermal vacuum, and structural dynamics facilities. The antenna was designed with four offset paraboloidal reflector surfaces with a focal length of 366.85 in and a primary surface accuracy goal of .069 in rms. Surface adjustment capability was provided by manually resetting the length of 96 surface control cords which emanated from the lower column extremity. A detailed description of the 15-meter Hoop/Column Antenna, major subassemblies, and a history of its fabrication, assembly, deployment testing, and verification measurements are given. The deviation for one aperture surface (except the outboard extremity) was measured after adjustments in follow-on tests at the Martin Marietta Near-field Facility to be .061 in; thus the primary surface goal was achieved.

Source record

Buckling analysis of the quadripod structure for the NASA 70-meter antenna

As part of the effort to extend the diameter of three Deep Space Network large earth antennas from 64 meters to 70 meters, a slim profiled quadripod structure was designed to support a 7.7 meter diameter subreflector for the 70 meter antenna. The new quadripod design, which particularly emphasizes reduced radio frequency blockage, is achieved by means of a narrow cross sectional profile of the legs. Buckling analysis, using NASTRAN, was conducted in this study to verify the safety margin for the quadripod structural stability.

Chian, Chian T.

The ac and dc electric field meters developed for the US Department of Energy

Two space-potential electric field meters developed at the Jet Propulsion Laboratory under the auspices of the U.S. Department of Energy are described. One of the meters was designed to measure dc fields, the other ac fields. Both meters use fiber optics to couple a small measuring probe to a remote readout device, so as to minimize field perturbation due to the presence of the probe. By using coherent detection, it has been possible to produce instruments whose operating range extends from about 10 V/m up to about 2.5 kV/cm, without the need for range switching on the probe. The electrical and mechanical design of both meters are described in detail. Data from laboratory tests are presented, as well as the results of the tests at the National Bureau of Standards and the Electric Power Research Institute's High Voltage Transmission Research Facility.

Kirkham, H.

DSN 63 64-meter antenna S- and X-band efficiency and system noise temperature calibrations, July 1986

The Deep Space Network (DSN) 64-meter antenna in Spain (DSN 63) has been calibrated prior to its upgrading to a 70-meter high efficiency configuration in preparation for the Voyager Neptune encounter in August 1989. The S-band (2285 MHz) and X-band (8420 MHz) effective area efficiency and system noise temperature calibrations were carried out during July 1986 to establish a baseline system performance for this station. It is expected that the 70-meter will result in at least a 1.9 dB G/T improvement at X-band relative to the 64-meter baseline reference.

Slobin, S. D.

Balloon-borne three-meter telescope for far-infrared and submillimeter astronomy

The scientific objectives, engineering analysis and design, results of technology development, and focal-plane instrumentation for a two-meter balloon-borne telescope for far-infrared and submillimeter astronomy are presented. The unique capabilities of balloon-borne observations are discussed. A program summary emphasizes the development of the two-meter design. The relationship of the Large Deployable Reflector (LDR) is also discussed. Detailed treatment is given to scientific objectives, gondola design, the mirror development program, experiment accommodations, ground support equipment requirements, NSBF design drivers and payload support requirements, the implementation phase summary development plan, and a comparison of three-meter and two-meter gondola concepts.

Fazio, Giovanni G.

Evaluation of the ride quality of a light twin engine airplane using a ride quality meter

A ride quality meter was used to establish the baseline ride quality of a light twin-engine airplane planned for use as a test bed for an experimental gust alleviation system. The ride quality meter provides estimates of passenger ride discomfort as a function of cabin noise and vibration (acceleration) in five axes (yaw axis omitted). According to the ride quality meter, in smooth air the cabin noise was the dominant source of passenger discomfort, but the total discomfort was approximately the same as that for the smooth-air condition. The researcher's subjective opinion, however, is that the total ride discomfort was much worse in the moderate turbulence than it was in the smooth air. The discrepancy is explained by the lack of measurement of the low-frequency accelerations by the ride quality meter.

Stewart, Eric C.

A wide-band monolithic quasi-optical power meter for millimeter- and submillimeter-wave applications

A novel monolithic power meter has been developed for submillimeter-wave applications (100 GHz to 10 THz). The detector is a large-area bismuth bolometer integrated on a 1.2-micron-thick dielectric membrane. This approach results in a wide-band, high-responsivity detector. The power meter is simple to fabricate, is inexpensive, and can be easily calibrated using a low-frequency network. Quasi-optical measurements at 90, 140, and 240 GHz show that the bolometer is polarization-independent and could be modeled by a simple transmission line model. Absolute power measurements at 90, 140, and 240 GHz show a + or - 5 percent accuracy and agree well with a calibrated Anritsu power meter at 90 GHz. Potential application areas are power calibration, antenna coupling efficiency measurements, and absolute power measurements from solid-state devices and far-infrared lasers at submillimeter wavelengths. Absolute output power measurements on a 220-280 GHz tripler using the quasi-optical power meter are presented as an application example.

Ling, Curtis C.

Low Flow Vortex Shedding Flow Meter for Hypergolics/all Media

A family of vortex shedding flow meters, for measurement of hypergol flows, was designed and fabricated. The test loops to evaluate the flow meters for water flow, as well as Freon -113 flow which simulates the hypergolic fluids, were modified and constructed to utilize a pump system which has an output capacity of 200 gpm. Test runs were conducted on the small 1/2 inch model with Freon 113 and on the larger models with water. Results showed that the linearity between the frequency of the vortices and the flow rate of the fluids was very close to that of the turbine flow meter. It is suggested that the vortex shedding flow meter is a possible replacement for the existing turbine type.

Thinh, Ngo Dinh

Liquid helium Dewar for one meter mirror testing

The NASA Ames Research Center has developed a baseline design for a One Meter Cryogenic Optical Test Facility (OMF) incorporating a liquid helium Dewar for cryogenic optical testing of one-meter-class mirrors, principally the Space Infrared Telescope Facility (SIRTF) primary mirror. The primary requirements for the test facility are as follows: (1) the facility must be capable of interferometrically testing any mirror, positioned face-up or face-down, with a diameter less than 1.5 meters and a radius of curvature from 1.5 to 5.5 meters; (2) the facility must achieve and maintain, for 24 hours, a mirror temperature of 4 K with a maximum radiative heat load of less than 500 mW to the mirror, using stored liquid helium and liquid nitrogen; (3) the facility must include a vibration-isolated metrology structure between the test mirror and an external interferometer, and (4) the facility must be operated by two persons and a test, starting from the mounting of a mirror to the removal of a mirror, must be conducted within one week.

Sarver, George L., III

The Use of a Chlorophyll Meter (SPAD-502) for Field Determinations of Red Mangrove (Rhizophora Mangle L.) Leaf Chlorophyll Amount

The red mangrove Rhizophora mangle L., is a halophytic woody spermatophyte common to the land-sea interface of tropical and subtropical intertidal zones. It has been reported that 60 to 75% of the coastline of the earth's tropical regions are lined with mangroves. Mangroves help prevent shoreline erosion, provide breeding, nesting and feeding areas for many marine animals and birds. Mangroves are important contributors of primary production in the coastal environment, and this is largely proportional to the standing crop of leaf chlorophylls. Higher intensities of ultraviolet radiation, resulting from stratospheric ozone depletion, can lead to a reduction of chlorophyll in terrestrial plants. Since the most common method for determining chlorophyll concentration is by extraction and this is labor intensive and time consuming, few studies on photosynthetic pigments of mangroves have been reported. Chlorophyll meter readings have been related to leaf chlorophyll content in apples and maples. It has also been correlated to nitrogen status in corn and cotton. Peterson et al., (1993) used a chlorophyll meter to detect nitrogen deficiency in crops and in determining the need for additional nitrogen fertilizer. Efforts to correlate chlorophyll meter measurements to chlorophyll content of mangroves have not been reported. This paper describes the use of a hand-held chlorophyll meter (Minolta SPAD-502) to determine the amount of red mangrove foliar chlorophyll present in the field.

Connelly, Xana M.

Suppression of Random Dopant-Induced Threshold Voltage Fluctuations in Sub-0.1-(micron)meter MOSFET's with Epitaxial and (delta)-Doped Channels

A detailed three-dimensional (3-D) statistical 'atomistic' simulation study of fluctuation-resistant sub-0.1-(micron)meter MOSFET architectures with epitaxial channels and delta doping is presented. The need for enhancing the fluctuation resistance of the sub-0.1-(micron)meter generation transistors is highlighted by presenting summarized results from atomistic simulations of a wide range of conventional devices with uniformly doped channel. According to our atomistic results, the doping concentration dependence of the random dopant-induced threshold voltage fluctuations in conventional devices is stronger than the analytically predicted fourth-root dependence. As a result of this, the scaling of such devices will be restricted by the "intrinsic" random dopant-induced fluctuations earlier than anticipated. Our atomistic simulations confirm that the introduction of a thin epitaxial layer in the MOSFET's channel can efficiently suppress the random dopant-induced threshold voltage fluctuations in sub-0.1-(micron)meter devices. For the first time, we observe an "anomalous" reduction in the threshold voltage fluctuations with an increase in the doping concentration behind the epitaxial channel, which we attribute to screening effects. Also, for the first time we study the effect of a delta-doping, positioned behind the epitaxial layer, on the intrinsic threshold voltage fluctuations. Above a certain thickness of epitaxial layer, we observe a pronounced anomalous decrease in the threshold voltage fluctuation with the increase of the delta doping. This phenomenon, which is also associated with screening, enhances the importance of the delta doping in the design of properly scaled fluctuation-resistant sub-0.1-(micron)meter MOSFET's. Index Terms-Doping, fluctuations, MOSFET, semiconductor device simulation, silicon devices, threshold.

Asenov, Asen

10 meter Sub-Orbital Large Balloon Reflector (LBR)

The realization of a large, space-based 10 meter class telescope for far-infrared/THz studies has long been a goal of NASA. Such a telescope could study the origins of stars, planets, molecular clouds, and galaxies; providing a much needed means of following-up on tantalizing results from recent successful missions such as Spitzer, Herschel, and SOFIA. Indeed, Herschel began its life in the US space program as the Large Deployable Reflector (LDR) to be assembled in low Earth orbit by shuttle astronauts. Escalating costs and smaller federal budget allocations resulted in a downsizing of the mission. However, by combining successful suborbital balloon and ground-based telescope technologies, the dream of a 10 meter class telescope free of ~99% of the Earth's atmospheric absorption in the far-infrared can be realized. The same telescope can also be used to perform sensitive, high spectral and spatial resolution limb sounding studies of the Earth's atmosphere in greenhouse gases such as CO, ClO, O3, and water, as well as serve as a high flying hub for any number of telecommunications and surveillance activities. Flight times of 100+ days will be possible, with instruments having mass and power requirements in excess of ~500 kg and ~1 kW.Here we present the results of our NIAC Step 1, Phase B design study where each key aspect of the LBR concept is discussed and recommendations made for further study in Phase II.These aspects include realization of a large spherical reflecting surface, spherical corrector, pointing system, instrument module, and service module/gondola. Once each hardware component is introduced, a typical LBR Mission profile is described that enables the realization of a stratospheric 10 meter THz observatory and limb sounder. Verification of the design approach was achieved by using a combination of analytical modelling, lab testing of materials and techniques, and building a 3 meter rooftop LBR prototype.

Telescope