Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microchannel plate detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

4U1722 + 11 - The discovery of an X-ray selected BL Lac object

The Uhuru X-ray source 4U1722 + 11 was observed using the microchannel-plate detector (High Resolution Imager) on the Einstein Observatory, and its coordinates measured to a precision of about 5 arcsec. A 16th-magnitude stellar object within the error circle was observed spectroscopically at CTIO, and at the AAT, and found to have a featureless continuum. Subsequent radio observations at the VLA have established that the object is a radio source at the level of 60 mJy, and optical polarization measurements have determined that the source exhibits variable polarization at the level of 10 percent. On the basis of these observations, it is concluded that 4U1722 + 11 is a member of the class of objects known as X-ray selected blazars of BL Lac objects.

Griffiths, R. E.↗

Spectrometer system for diffuse extreme ultraviolet radiation

A unique grazing incidence spectrometer system has been designed to study diffuse line emission between 80 and 650 A with 10-30 A resolution. The minimum detectable emission line strength during a 5-min observation ranges from 100-2000 ph/sq cm sec str. The instrument uses mechanically ruled reflection gratings placed in front of a linear array of mirrors. These mirrors focus the spectral image on microchannel plate detectors located behind thin filters. The field of view is 40 min of arc by 15 deg, and there is no spatial imaging. This instrument has been fabricated, calibrated, and successfully flown on a sounding rocket to observe the astronomical background radiation.

Labov, Simon E.↗

New measurements of the far ultraviolet scattering properties of interstellar dust

An analysis is presented for the spectra of the diffuse ultraviolet background taken during shuttle flight STS-61C (January 1986). Eight regions of the sky were observed for approximately 20 minutes each, using a spectrograph designed specifically to perform measurements of the UV background. The field of view was 3.8 deg x 8 min, with imaging along the slit to confine stellar contamination. The instrument featured a shutter mechanism to measure internal background during flight, a low-scatter holographically ruled diffraction grating, photon counting microchannel plate detectors, through baffling, and a crystal window to further attenuate stray light. The spectra covered the range 1400 to 1850 A and was binned in 50 A bands. The procedure for substracting the contribution of stars too faint to be detected as discrete sources during the observations (in general this represents a small fraction of the total intensity detected except at the longest wavelengths). A radiative transfer model used to interpret the data and set confidence intervals on the relevant parameters is described. It was found that the continuum component of the diffuse ultraviolet background arises primarily from two sources. One source is scattering of starlight by interstellar dust with an albedo of about 12 percent and a relatively isotropic phase function. A second source consists of about 150 photons/cm/sec/ster/A of extragalactic light which is attenuated by the dust in the galaxy. Although emission features possibly associated with molecular H2 are detected in one look direction, fluorescence of H2 is not a major contributor to the diffuse UV background, at least at galactic latitudes greater than -10 degrees.

Hurwitz, Mark↗

Space astronomical telescopes and instruments; Proceedings of the Meeting, Orlando, FL, Apr. 1-4, 1991

The present volume on space astronomical telescopes and instruments discusses lessons from the HST, telescopes on the moon, future space missions, and mirror fabrication and active control. Attention is given to the in-flight performance of the Goddard high-resolution spectrograph of the HST, the initial performance of the high-speed photometer, results from HST fine-guidance sensors, and reconstruction of the HST mirror figure from out-of-focus stellar images. Topics addressed include system concepts for a large UV/optical/IR telescope on the moon, optical design considerations for next-generation space and lunar telescopes, the implications of lunar dust for astronomical observatories, and lunar liquid-mirror telescopes. Also discussed are space design considerations for the Space Infrared Telescope Facility, the Hubble extrasolar planet interferometer, Si:Ga focal-plane arrays for satellite and ground-based telescopes, microchannel-plate detectors for space-based astronomy, and a method for making ultralight primary mirrors.

Bely, Pierre Y.↗

A Remote Laser-mass Spectrometer for Determination of Elemental Composition

Determination of the elemental composition of lunar, asteroid, and planetary surfaces is a major concern for science and resource utilization of space. The science associated with the development of a satellite or lunar rover laser-mass spectrometer instrument is presented here. The instrument would include a pulsed laser with sufficient energy to create a plasma on a remote surface. Ions ejected from this plasma travel back to the spacecraft or rover, where they are analyzed by a time-of-flight mass spectrometer, giving the elemental and isotope composition. This concept is based on the LIMA-D instrument on board the former Soviet Union Phobos-88 spacecraft sent to Mars. A laser-mass spectrometer placed on a rover or satellite would substantially improve the data return over alternative techniques. The spatial resolution would be centimeters, and a complete mass spectrum could be achieved in one laser shot. An experiment is described that demonstrates these features. A 400 mj Nd:YAG laser is focused, to an intensity of 10(exp 11) w/sq cm, onto a Al, Ag, Cu, Ge, or lunar simulant target. A plasma forms from which ions are ejected. Some of these ions travel down an 18-m evacuated flight tube to a microchannel plate detector. Alternatively, the ions are captured by an ion trap where they are stored until pulsed into a 1-m time-of-flight mass spectrometer, giving the elemental composition of the remote surface. A television camera monitors the plasma plume shape, and a photodiode monitors the temporal plasma emission . With this system, ions of Al, Ag, Cu, Ge, and lunar simulant have been detected at 18 m. The mass spectrum from the ion trap and 1-m time-of-flight tube will be presented.

Deyoung, R. J.↗

High throughput narrowband 83.4 nm self-filtering camera

Photometric imaging of ionospheric/magnetospheric O II emission at 83.4 nm is a primary objective for mapping the distribution of O(+) ions. However, instrumental sensitivity has been a major barrier to realizing this goal. We report an instrumental design employing a low focal ratio three-mirror camera where the reflecting surfaces act as both narrowband reflection filters at 83.4 nm and as a high quality imaging system. The design includes coatings with reflectances that are relatively insensitive to the angle of incidence of light. The peak reflectance per mirror is more than 60 percent at 83.4 nm with the average reflectance for out-of-band wavelengths of less than 5 percent. The net reflective transmission for the three mirrors is greater than 20 percent with 6.8 nm bandwidth and 0.01 percent maximum transmittance for out-of-band wavelengths. The transmittance at 30.4 nm is 0.03 percent at 58.4 nm 0.05 percent, and at 121.6 nm 0.004 percent. When used with an open microchannel plate detector, contamination by H Ly-alpha is essentially eliminated. With this spectral purity and effective elimination of major contributors to background contamination noise, a signal-to-noise ratio (excluding detector noise) of 10 is achievable for a 0.01 R signal in 8.8 seconds for the full 6 deg field-of-view.

Zukic, Muamer↗

The ALEXIS data processing package: An IDL based system

The Array of Low Energy X-ray Imaging Sensors (ALEXIS) experiment consists of a mini-satellite containing six wide angle EUV/ultrasoft x-ray telescopes. Its purpose is to map out the sky in three narrow (approximately 5 percent) bandpasses around 66, 71, and 93 eV. The 66 and 71 eV bandpasses are centered on intense Fe emission lines which are characteristic of million degree plasmas such as the one thought to produce the soft x-ray background. The 93 eV bandpass is not near any strong emission lines and is more sensitive to continuum sources. The mission will be launched on the Pegasus Air Launched Vehicle in the second half of 1992 into a 400-nautical-mile, high inclination orbit and will be controlled entirely from a small ground station located at Los Alamos. The project is a collaborative effort between Los Alamos National Laboratory, Sandia National Laboratory, and the University of California-Berkeley Space Sciences Laboratory. The six telescopes are arranged in three pairs. As the satellite spins twice a minute they scan the entire anti-solar hemisphere. Each f/1 telescope consists of a spherical, multilayer-coated mirror with a curved, microchannel plate detector located at the prime focus. The multilayer coatings determine the bandpasses of the telescopes. The field of view of each telescope is 30 degrees with a spatial resolution of 0.5 degree, limited by spherical aberration. The data processing requirements for ALEXIS are large. Each event is one of the six telescopes is telemetered to the ground with its time of arrival and position on the detector. This information must be folded with the aspect solution for the satellite to reconstruct the direction on the sky from which the photon came. Because of the way the six telescopes scan the sky, the effective exposure calculation is also very computationally intensive. ALEXIS may generate up to 100 megabytes of raw data per day, which are converted into a gigabyte per day of processed data. While the processing job for ALEXIS is sizable, the programming staff is small. To maximize programming efficiency, and to make the best use of tools available in the public domain, we chose IDL as our software development platform. IDL was used from the start of instrument development through flight. We use IDL as a top-level executive for the processing tasks (replacing Unix shell scripts), as a device independent graphics engine, as a database manager, and as a final data manipulator. IDL routines spawn special purpose C programs to perform detailed telemetry deconvolution and other specialized functions. We discuss the use of IDL and C within the processing and archiving strategy for the ALEXIS data anlaysis system as implemented on a SPARCstation platform. We also show results from our End-to-End software simulation capability as processed by our analysis codes.

Bloch, J. J.↗

In situ detection of tropospheric OH and HO2 by laser-induced fluorescence in a detection chamber at low pressure

Just as in the method of Hard and O'Brien, ambient air is pulled through an approximately 1 mm diameter inlet into a detection chamber that is maintained at a pressure of 2.4 torr. The ambient air stream travels through the detection chamber with a velocity of greater than 100 m sec(exp -1) in a narrow stream, constrained by the addition of an inert gas flow (0.4 torr). The OH molecule is both excited and detected in the A(exp 2)Sigma (v' = 0) yields X(exp 2)II (v'' = 0) transition at 308 nm. Light from a copper vapor-pumped dye laser (rep. rate = 10kHz; pulse length = 20 ns; linewidth = .1 cm(exp -1), and average power = 15 mW), resonant with the Q(sub 1)(3) transition, is multipassed through a White cell and intercepts the air stream as 24 non-overlapping 2mm by 5mm beams. A fast microchannel plate detector is turned off during the laser pulse to prevent saturation of the detector due to Rayleigh and chamber scattering. It is turned on 30-100 nsec after the end of the laser pulse for 300 ns to collect resonance fluorescence from OH. HO2 is detected by chemical conversion to OH by reaction with reagent NO, followed by OH detection. Both the detection sensitivity and the inlet characteristics must be understood for any in situ instrument. For the calibration of the detection sensitivity, OH is produced quantitatively by the fast H + NO2 yields OH + NO reaction in a low pressure, flowing discharge tube connected to the detection chamber. The inlet transmission of OH inlet is calibrated separately.

Brune, William H.↗

The Extreme Ultraviolet Spectrograph Sounding Rocket Payload: Recent Modifications for Planetary Observations in the EUV/FUV

We report on the status of modifications to an existing extreme ultraviolet (EUV) telescope/spectrograph sounding rocket payload for planetary observations in the 800 - 1200 A wavelength band. The instrument is composed of an existing Wolter Type 2 grazing incidence telescope, a newly built 0.4-m normal incidence Rowland Circle spectrograph, and an open-structure resistive-anode microchannel plate detector. The modified payload has successfully completed three NASA sounding rocket flights within 1994-1995. Future flights are anticipated for additional studies of planetary and cometary atmospheres and interstellar absorption. A detailed description of the payload, along with the performance characteristics of the integrated instrument are presented. In addition, some preliminary flight results from the above three missions are also presented.

Slater, David C.↗

Global Mapping of the Interstellar Medium in the Far Ultraviolet

In early 1993, funding for the NUVIEWS experiment was initiated. The experiment was completed and delivered to Wallops Flight Facility in March 1996, where it has completed flight integration and testing successfully. We feel that the three year development time was too long by a year, and that the history deserves some explanation. The construction of four complete four-mirror telescope systems with unique multilayer coatings, superpolished aspheres, and four large-format, high-resolution microchannel-plate detectors required a substantial effort. Our original design included only three telescopes, but we added a fourth 18 months ago to ensure rejection of all potential contaminating line features. A six-month SMEX Definition study in 1994 required substantial efforts by key personnel. There was great synergy here: the four NUVIEWS detectors are prototypes for the SMEX UV-survey mission (JUNO). In 1993, the Principal Investigator C. Martin took a position at Caltech. The transition of the laboratory from Columbia to Caltech was unfortunately timed and led to more delays, including an additional laboratory move and calibration tank/clean room reconstruction. Following the May NUVIEWS launch, the laboratory move to Caltech will be complete.

Martin, Christopher↗

Hardware and Methods of the Optical End-to-End Test of the Far Ultraviolet Spectroscopic Explorer (FUSE)

The Far Ultraviolet Spectroscopic Explorer (FUSE), currently being tested and scheduled for a 1999 launch, is an astrophysics satellite designed to provide high spectral resolving power (Lambda/(Delta)Lambda = 24,000-30,000) over the interval 90.5-118.7 nm. The FUSE optical path consists of four co-aligned, normal incidence, off-axis parabolic, primary mirrors which illuminate separate Rowland circle spectrograph channels equipped with holographic gratings and delay line microchannel plate detectors. We describe the hardware and methods used for the optical end-to-end test of the FUSE instrument during satellite integration and test. Cost and schedule constraints forced us to devise a simplified version of the planned optical test which occurred in parallel with satellite thermal-vacuum testing. The optical test employed a collimator assembly which consisted of four co-aligned, 15" Cassegrain telescopes which were positioned above the FUSE instrument, providing a collimated beam for each optical channel. A windowed UV light source, remotely adjustable in three axes, was mounted at the focal plane of each collimator. Problems with the UV light sources, including high F-number and window failures, were the only major difficulties encountered during the test. The test succeeded in uncovering a significant problem with the secondary structure used for the instrument closeout cavity and, furthermore, showed that the mechanical solution was successful. The hardware was also used extensively for simulations of science observations, providing both UV light for spectra and visible light for the fine error sensor camera.

Conard, Steven J.↗

Optical Performance Modeling of FUSE Telescope Mirror

We describe the Metrology Data Processor (METDAT), the Optical Surface Analysis Code (OSAC), and their application to the image evaluation of the Far Ultraviolet Spectroscopic Explorer (FUSE) mirrors. The FUSE instrument - designed and developed by the Johns Hopkins University and launched in June 1999 is an astrophysics satellite which provides high resolution spectra (lambda/Delta(lambda) = 20,000 - 25,000) in the wavelength region from 90.5 to 118.7 nm The FUSE instrument is comprised of four co-aligned, normal incidence, off-axis parabolic mirrors, four Rowland circle spectrograph channels with holographic gratings, and delay line microchannel plate detectors. The OSAC code provides a comprehensive analysis of optical system performance, including the effects of optical surface misalignments, low spatial frequency deformations described by discrete polynomial terms, mid- and high-spatial frequency deformations (surface roughness), and diffraction due to the finite size of the aperture. Both normal incidence (traditionally infrared, visible, and near ultraviolet mirror systems) and grazing incidence (x-ray mirror systems) systems can be analyzed. The code also properly accounts for reflectance losses on the mirror surfaces. Low frequency surface errors are described in OSAC by using Zernike polynomials for normal incidence mirrors and Legendre-Fourier polynomials for grazing incidence mirrors. The scatter analysis of the mirror is based on scalar scatter theory. The program accepts simple autocovariance (ACV) function models or power spectral density (PSD) models derived from mirror surface metrology data as input to the scatter calculation. The end product of the program is a user-defined pixel array containing the system Point Spread Function (PSF). The METDAT routine is used in conjunction with the OSAC program. This code reads in laboratory metrology data in a normalized format. The code then fits the data using Zernike polynomials for normal incidence systems or Legendre-Fourier polynomials for grazing incidence systems. It removes low order terms from the metrology data, calculates statistical ACV or PSD functions, and fits these data to OSAC models for the scatter analysis. In this paper we briefly describe the laboratory image testing of FUSE spare mirror performed in the near and vacuum ultraviolet at John Hopkins University and OSAC modeling of the test setup performed at NASA/GSFC. The test setup is a double-pass configuration consisting of a Hg discharge source, the FUSE off-axis parabolic mirror under test, an autocollimating flat mirror, and a tomographic imaging detector. Two additional, small fold flats are used in the optical train to accommodate the light source and the detector. The modeling is based on Zernike fitting and PSD analysis of surface metrology data measured by both the mirror vendor (Tinsley) and JHU. The results of our models agree well with the laboratory imaging data, thus validating our theoretical model. Finally, we predict the imaging performance of FUSE mirrors in their flight configuration at far-ultraviolet wavelengths.

Saha, Timo T.↗

Design and Development of Thin Plastic Foil, Conical Approximation, High Through-out X-Ray Telescope: Light Weight, Thin Plastic Foil, X-Ray Telescopes

We present results from a program to develop an X-ray telescope made from thin plastic shells. Our initial results have been obtained from multi-shell cylindrical lenses that are used in a point-to-point configuration to image the small focal spot of a an X-ray tube on a microchannel plate detector. We describe the steps that led up to the present design and present data from the tests that have been used to identify the properties of the plastic material that make it a suitable X-ray reflector. We discuss two applications of our technology to X-ray missions that are designed to address some of the scientific priorities set forth in NASA's long term plans for high energy astrophysics. One mission will observe in the 1 - 10 keV band, the other will extend up to ca. 100 keV.

Schnopper, Herbert W.↗

RF Manipulation and Detection of Protons in the High Performance Antiproton Trap (HiPAT) Experiment

HiPAT is a Penning-Malmberg trap designed to contain 10(exp 12) particles diagnostics of the plasma. Destructive particle detection is performed by extracting trapped ions from HiPAT and colliding them with a microchannel plate detector (providing number and energy information). The improved RF system has been used to detect various plasma modes for both electron and ion plasmas in the two traps at MSFC, including axd, cyclotron, and diocotron modes. New diagnostics are also being added to HiPAT to measure the axial density distribution of the trapped cloud to match measured RF plasma modes to plasma conditions. In addition, plasma modeling efforts have been started using the XOOPIC code.

Martin, James↗

Fabrication and Calibration of FORTIS

The Johns Hopkins University sounding rocket group is entering the final fabrication phase of the Far-ultraviolet Off Rowland-circle Telescope for Imaging and Spectroscopy (FORTIS); a sounding rocket borne multi-object spectro-telescope designed to provide spectral coverage of 43 separate targets in the 900 - 1800 Angstrom bandpass over a 30' x 30' field-of-view. Using "on-the-fly" target acquisition and spectral multiplexing enabled by a GSFC microshutter array, FORTIS will be capable of observing the brightest regions in the far-UV of nearby low redshift (z approximately 0.002 - 0.02) star forming galaxies to search for Lyman alpha escape, and to measure the local gas-to-dust ratio. A large area (approximately 45 mm x 170 mm) microchannel plate detector built by Sensor Sciences provides an imaging channel for targeting flanked by two redundant spectral outrigger channels. The grating is ruled directly onto the secondary mirror to increase efficiency. In this paper, we discuss the recent progress made in the development and fabrication of FORTIS, as well as the results of early calibration and characterization of our hardware, including mirror/grating measurements, detector performance, and early operational tests of the micro shutter arrays.

Fleming, Brian T.↗

Introduction: Photons and Ground-Based

A Conference on Measurement Techniques for Solar and Space Physics was held on 20-24 April 2015 in Boulder, Colorado, at the National Center for Atmospheric Research Center Green Campus. The present volume collects together the conference papers for photons and ground-based categories. This gathering of over 200 scientists and instrumentalists was born out of the desire to collect in one place the latest experiment and instrument technologies required for advancement of scientific knowledge in the disciplines of solar and space physics. The two goals for this conference and the subsequent publication of its content are (a) to describe measurement techniques and technology development needed to advance high priority science in the fields of solar and space physics; and (b) to provide a survey or reference of techniques for in situ measurement and remote sensing of space plasmas. Towards this end, our goal has always been inspired by the two 1998 Geophysical Monographs (Nos. 102 and 103) entitled, "Measurement Techniques in Space Plasmas" (particles and fields) [Pfaff et al., 1998a, 1998b], which have served as a reference and resource for advanced students, engineers, and scientists who wish to learn the fundamentals of measurement techniques and technology in this field. Those monographs were the product of an American Geophysical Union Chapman Conference that took place in Santa Fe, NM, in 1995: "Measurement Techniques in Space Plasmas-What Works, What Doesn't." Two decades later, we believe that it is appropriate to revisit this subject, in light of recent advances in technology, research platforms, and analysis techniques. Moreover, we now include direct measurements of neutral gases in the upper atmosphere, optical imaging techniques, and remote observations in space and on the ground. Accordingly, the workshop was organized among four areas of measurement techniques: particles, fields, photons, and ground-based. This two-set volume is largely composed of the content of that workshop. Special attention is given to those techniques and technologies that demonstrate promise of significant advancement in measurements that will enable the highest priority science as described in the 2012 National Research Council Decadal Survey [Baker and Zurbuchen et al., 2013]. Additionally, a broad tutorial survey of the current technologies is provided to serve as reference material and as a basis from which advanced and innovative ideas can be discussed and pursued. Included are instrumentation and techniques to observe the solar environment from its interior to its outer atmosphere, the heliosphere out to the interstellar regions, in geospace, and other planetary magnetospheres and atmospheres. To make significant progress in priority science as expressed in the National Research Council solar and space physics decadal survey and recent NASA Heliophysics roadmaps, identification of enabling new measurement techniques and technologies to be developed is required. Also, it is valuable to the community and future scientists and engineers to have a complete survey of the techniques and technologies used by the practitioners of solar and space physics. As with the 1995 conference and subsequent 1998 publication, it is incumbent on the community to identify those measurements that are particularly challenging and still require new techniques to be identified and tested to enable the necessary accuracy and resolution of certain parameters to be achieved. The following is a partial list of the measurement technique categories that are featured in these special publications: Particles; Thermal plasma to MeV energetic particles, neutral gas properties including winds, density, temperature, and composition, and enhanced neutral atom imaging; Fields; DC electric and magnetic fields, plasma waves, and electron drift instruments from which the plasma velocity information provides a measure of the DC electric field; Photons; Instruments sensitive from the near-infrared to X-rays; Contributions of techniques and technology for optical design, optical components, sensors, material selection for cameras, telescopes, and spectrographs; Ground based; Remote sensing methods for solar and geospace activity and space weather. The focus includes solar observatories, all-sky cameras, lidars, and ionosphere thermosphere mesosphere observatory systems such as radars, ionosondes, GPS receivers, magnetometers, conjugate observations, and airborne campaigns. The present volume collects together the papers for photons and ground-based categories. The companion volume collects together the papers for particles and fields categories. It is recognized that there are measurement techniques that overlap among the four categories. For example, use of microchannel plate detectors is used in photon and particle measurement techniques or the observation of visible photons and magnetic fields in space and on the ground share common technologies. Therefore, the reader should consider the entire collection of papers as they seek to understand particular applications. We hope that these volumes will be as valuable as a reference for our community as the earlier 1998 volumes have been.

Spann, James↗

The Lunar Environment Heliophysics X-Ray Imager (LEXI) Mission

The Lunar Environment heliospheric X-ray Imager (LEXI) is a wide field-of-view soft Xray telescope developed to study solar wind-magnetosphere coupling. LEXI is part of the Blue Ghost 1 mission comprised of 10 payloads to be deployed on the lunar surface. LEXI monitors the dayside magnetopause position and shape as a function of time by observing soft X-rays (0.1–2 keV) emitted from solar wind charge-exchange between exospheric neutrals and high charge-state solar wind plasma in the dayside magnetosheath. Measurements of the shape and position of the magnetopause are used to test temporal models of mesoand macro-scale magnetic reconnection. To image the boundary, LEXI employs lobster-eye optics to focus X-rays to a microchannel plate detector with a 9.1◦ × 9.1◦ field of view.

Lunar↗

Quantum efficiencies of imaging detectors with alkali halide photocathodes. I - Microchannel plates with separate and integral CsI photocathodes

Measurements and comparisons have been made of the quantum efficiencies of microchannel plate (MCP) detectors in the far-UV (below 2000-A) wavelength range using CsI photocathodes (a) deposited on the front surfaces of microchannel plates and (b) deposited on solid substrates as opaque photocathodes with the resulting photoelectrons input to microchannel plates. The efficiences were measured in both pulse-counting and photodiode modes of operation. Typical efficiencies are about 15 percent at 1216 A for a CsI-coated MCP compared with 65 percent for an opaque CsI photocathode MCP detector. Special processing has yielded an efficiency as high as 20 percent for a CsI-coated MCP. This may possibly be further improved by optimization of the tilt angle of the MCP channels relative to the front face of the MCP and incident radiation. However, at present there still remains a factor of at least 3 quantum efficiency advantage in the separate opaque CsI photocathode configuration.

Carruthers, George R.↗