Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microwave absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Non-resonant Microwave Absorption and Boundary Current Response of Ba{sub 0.34}K{sub 0.64}Fe{sub 2}As{sub 2} Superconducting Single Crystals

Boundary current response of Ba{sub 0.34}K{sub 0.64}Fe{sub 2}As{sub 2} (BaK122) single crystals was probed by non-resonant microwave absorption (NRMA) as a function of 100-KHz modulation field at an intermediate temperature, namely, 25 K, which is 10 K below the actual T{sub c}. The measurements were done for both field parallel and perpendicular to the iron arsenide plane configuration. A weak anisotropic effect is noted. However, it is observed that the boundary current response depends on the modulation field value and it increases as we increase the modulation field value from 1 to 9 G. Further, this boundary current response strongly depends on the microwave power. We have shown that these modulation field and microwave power dependence of the boundary current response of NRMA signals in BaK122 iron arsenide crystal can be qualitatively understood through the Dulcic model.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Laboratory evaluation and application of microwave absorption properties under simulated conditions for planetary atmospheres

Radio absorptivity data for planetary atmospheres obtained from spacecraft radio occultation experiments and earth-based radio astronomical observations can be used to infer abundances of microwave absorbing atmospheric constituents in those atmospheres, as long as reliable information regarding the microwave absorbing properties of potential constituents is available. The use of theoretically derived microwave absorption properties for such atmospheric constituents, or using laboratory measurements of such properties under environmental conditions which are significantly different than those of the planetary atmosphere being studied, often leads to significant misinterpretation of available opacity data. The recognition of the need to make such laboratory measurements of simulated planetary atmospheres over a range of temperatures and pressures which correspond to the altitudes probed by both radio occultation experiments and radio astronomical observations, and over a range of frequencies which correspond to those used in both radio occultation experiments and radio astronomical observations, has led to the development of a facility at Georgia Tech which is capable of making such measurements. The goal of this investigation was to conduct such measurements and to apply the results to a wide range of planetary observations, both spacecraft and earth-based, in order to determine the identity and abundance profiles of constituents in those planetary atmospheres.

Steffes, Paul G.↗

Laboratory evaluation and application of microwave absorption properties under simulated conditions for planetary atmospheres

Radio absorptivity data for planetary atmospheres obtained from spacecraft radio occultation experiments and earth-based radio astronomical observations can be used to infer abundances of microwave absorbing atmospheric constituents in those atmospheres, as long as reliable information regarding the microwave absorbing properties of potential constituents is available. The use of theoretically-derived microwave absorption properties for such atmospheric constituents, or using laboratory measurements of such properties under environmental conditions which are significantly different than those of the planetary atmosphere being studied, often leads to significant misinterpretation of available opacity data. For example, laboratory measurements performed by Fahd and Steffes have shown that the opacity from gaseous SO2 under simulated Venus conditions can be well described by the Van Vleck-Weisskopf lineshape at wavelengths shortward of 2 cm, but that the opacity of wavelengths greater than 2 cm is best described by a different lineshape that was previously used in theoretical predictions. The recognition of the need to make such laboratory measurements of simulated planetary atmospheres over a range of temperatures and pressures which correspond to the altitudes probed by both radio occultation experiments and radio astronomical observations, and over a range of frequencies which correspond to those used in both radio occultation experiments and radio astronomical observations, has led to the development of a facility at Georgia Tech which is capable of making such measurements. It has been the goal of this investigation to conduct such measurements and to apply the results to a wide range of planetary observations, both spacecraft and earth-based, in order to determine the identity and abundance profiles of constituents in those planetary atmospheres.

Steffes, Paul G.↗

Laboratory Evaluation and Application of Microwave Absorption Properties Under Simulated Conditions for Planetary Atmospheres

Radio absorptivity data for planetary atmospheres obtained from spacecraft radio occultation experiments and earth-based radio astronomical observations can be used to infer abundances of microwave absorbing constituents in those atmospheres, as long as reliable information regarding the microwave absorbing properties of potential constituents is available. The use of theoretically-derived microwave absorption properties for such atmospheric constituents, or using laboratory measurements of such properties under environmental conditions which are significantly different than those of the planetary atmosphere being studied, often leads to significant misinterpretation of available opacity data. Laboratory measurements completed under this grant (NAGW-533), have shown that the opacity from, SO2 under simulated Venus conditions is best described by a different lineshape than was previously used in theoretical predictions. The recognition of the need to make such laboratory measurements of simulated planetary atmospheres over a range of temperatures and pressures which correspond to the altitudes probed by both radio occultation experiments and radio astronomical observations, and over a range of frequencies which correspond to those used in both radio occultation experiments and radio astronomical observations, has led to the development of a facility at Georgia Tech which is capable of making such measurements. It has been the goal of this investigation to conduct such measurements and to apply the results to a wide range of planetary observations, both spacecraft and earth-based, in order to determine the identity and abundance profiles of constituents in those planetary atmospheres.

Steffes, Paul G.↗

Investigation of Magnetic and Microwave Absorption Properties of Ba{sub (1−2x)}La{sub x}Na{sub x}Fe{sub 10}CoTiO{sub 19} Hexaferrites in 18.0–26.5 GHz Band

A series of Ba{sub (1−2x)}La{sub x}Na{sub x}Fe{sub 10}CoTiO{sub 19} hexaferrite samples with x = 0.00–0.25 (step size 0.05) were prepared by using conventional solid-state reaction technique. The magnetic properties of the hexaferrites have been investigated at room temperature by employing a vibrating sample magnetometer. There is an overall decrease in saturation magnetization from 70.64 to 57.83 emu/g with an increase in doping concentration from x = 0.00–0.25. The microwave measurements were done utilizing vector network analyzer in the k-band (18.0–26.5 GHz) frequency range. The electromagnetic measurements revealed that the gross tangent loss is maximum for x = 0.10 sample. The microwave absorption measurements show that sample x = 0.10 with 1.4 mm thickness exhibits a reflection loss of − 26.59 dB (99.78% signal absorption) and 7.65 GHz bandwidth. Thus, it is considered for thin single-layer broadband microwave absorber applications in 18.0–26.5 GHz frequency range.

36 MATERIALS SCIENCE↗

Large-scale synthesis, characterization and microwave absorption properties of carbon nanotubes of different helicities

Carbon nanotubes of high helicity (H-HCNTs, Sample A) have been synthesized in large-scale by pyrolysis of acetylene at 450 deg. C over Fe nanoparticles derived from coprecipitation/hydrogen reduction method. With controlled introduction of hydrogen during acetylene pyrolysis, CNTs of low helicity (L-HCNTs, Sample B) and worm-like CNTs (Sample C) were obtained in large quantities. The yields of the CNTs products are high, especially that of H-HCNTs (ca. 7474%). The complex permittivity and permeability of Composites A, B, and C that contain Samples A, B and C (30 wt%) were measured in the 2-18 GHz frequency range. Good absorption of electromagnetic wave (reflection loss<-20 dB) was observed in the 7.18-10.68 and 7.5-10.7 GHz range over Composites B and C (2.0-3.0 mm thickness), respectively. Thus, through the suggested route, CNTs can be produced easily and selectively in large quantities. The lightweight materials can be utilized for microwave absorption. - Graphical abstract: FESEM image of Sample B and reflection loss versus frequency of Composite B (containing 30 wt% of Sample B) in the range of 2-18 GHz.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Laboratory evaluation and application of microwave absorption properties under simulated conditions for planetary atmospheres

The recognition of the need to make laboratory measurements of simulated planetary atmospheres over a range of temperatures and pressure which correspond to the altitudes probed by radio occultation experiments, and over a range of frequencies which correspond to both radio occultation experiments and radio astronomical observations, has led to the development of a facility at Georgia Tech which is capable of making such measurements. Construction was completed of the outer planets simulator and measurements were conducted of the microwave absorption and refraction from nitrogen under simulated Titan conditions. The results of these and previous laboratory measurements were applied to a wide range of microwave opacity measurements, in order to derive constituent densities and distributions in planetary atmospheres such as Venus.

Steffes, P. G.↗

Low temperature charge transport and microwave absorption of carbon coated iron nanoparticles–polymer composite films

Highlights: ► Carbon coated Fe nanoparticle–PVC composite films were prepared by solution casting method. ► A low electrical percolation threshold of 2.2 was achieved. ► The low temperature electrical conductivity follows variable range hopping type conduction. ► An EMI shielding of 18 dB was achieved in 200 micron thick film. -- Abstract: In this paper, the low temperature electrical conductivity and microwave absorption properties of carbon coated iron nanoparticles–polyvinyl chloride composite films are investigated for different filler fractions. The filler particles are prepared by the pyrolysis of ferrocene at 980 °C and embedded in polyvinyl chloride matrix. The high resolution transmission electron micrographs of the filler material have shown a 5 nm thin layer graphitic carbon covering over iron particles. The room temperature electrical conductivity of the composite film changes by 10 orders of magnitude with the increase of filler concentration. A percolation threshold of 2.2 and an electromagnetic interference shielding efficiency (EMI SE) of ∼18.6 dB in 26.5–40 GHz range are observed for 50 wt% loading. The charge transport follows three dimensional variable range hopping conduction.

36 MATERIALS SCIENCE↗

Microwave absorption through the martensitic and Curie transitions in Ni 45 Cr 5 Mn 37 In 13

We have investigated the electron spin resonance (ESR) of the Ni 45 Cr 5 Mn 37 In 13 Heusler alloy near the structural and magnetic phase transition temperatures. Ni 45 Cr 5 Mn 37 In 13 is characterized by a first order magnetostructural (martensitic) transition (MST) with magneto-responsive properties such as magnetoresistance, Hall and magnetocaloric effects, etc., in the vicinity of the MST. Since the details and origins of these behaviors are not well understood, we used a technique beyond magnetometry, i.e., “microwave absorption”, to reveal new information. ESR studies of Ni 45 Cr 5 Mn 37 In 13 shows that this compound is characterized by wide absorption spectra at temperatures greater than 250 K that depend on the angle of the magnetic field relative to the normal to the sample plate (α) and temperature (T). Two local maxima at about 5 and 6 kOe were detected for α close to zero degrees near the martensitic transition and Curie temperatures. In conclusion, the absorption spectra are discussed along with the results of the structural and magnetic studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of Synthesis Approaches and Morphological Properties on Dielectric Enhancement and Microwave Absorption of Fe{sub 3}O{sub 4}/PANI Nanocomposites

In the present work, Fe{sub 3}O{sub 4} spherical (Fe{sub 3}O{sub 4}-cop) and raspberry-like (Fe{sub 3}O{sub 4}-hyd) nanoparticles were synthesized via co-precipitation and hydrothermal routes, respectively. Fe{sub 3}O{sub 4}/polyaniline (PANI) nanocomposites were prepared by in situ oxidative polymerization of aniline monomer in the presence of the Fe{sub 3}O{sub 4} materials. Characterization of the nanocomposites by XRD, FT-IR, FESEM, and TEM techniques revealed a core/shell structure for Fe{sub 3}O{sub 4}-hyd/PANI, unlike the PANI blocks with embedded Fe{sub 3}O{sub 4} and γ-Fe{sub 2}O{sub 3} observed in Fe{sub 3}O{sub 4}-cop/PANI composites. The larger and pure magnetite nanoparticles produced with the hydrothermal process and the respective nanocomposite with PANI possess higher magnetization and coercivity values, according to the magnetic investigation with VSM. Moreover, according to the electromagnetic characterization in the X-band, the Fe{sub 3}O{sub 4}-hyd/PANI nanocomposite exhibits the highest complex permittivity level, as a consequence of increased interfacial polarization in the Fe{sub 3}O{sub 4}-hyd/PANI system. On this account, reflection loss measurements have shown the superior microwave absorption capability of Fe{sub 3}O{sub 4}-hyd/PANI composite, compared with Fe{sub 3}O{sub 4}-cop/PANI, with a measured maximum of −31.28 dB at 8.5 GHz for 3.5 mm layer thickness.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Microwave absorption of oxygen measured with a Fabry-Perot spectrometer

A semiconfocal configuration of a Fabry-Perot interferometer is described, which can be used for measuring moderately weak absorption at a fixed microwave frequency as a function of pressure by measuring the change in the Q of the system when the gas is introduced. An accuracy of 0.3 dB/km at 58.82 GHz is achieved with just conventional laboratory equipment. The absorption need not be resonant, and can be determined as a function of such physical factors as pressure, temperature, and mixture composition. Oxygen absorption measurements support calculations based on theories of line overlap inside the oxygen absorption band at subatmospheric pressure.

Poon, R. K. L.↗

Microwave absorptions of ultrathin conductive films and designs of frequency-independent ultrathin absorbers

We study the absorption properties of ultrathin conductive films in the microwave regime, and find a moderate absorption effect which gives rise to maximal absorbance 50% if the sheet (square) resistance of the film meets an impedance matching condition. The maximal absorption exhibits a frequency-independent feature and takes place on an extremely subwavelength scale, the film thickness. As a realistic instance, ∼5 nm thick Au film is predicted to achieve the optimal absorption. In addition, a methodology based on metallic mesh structure is proposed to design the frequency-independent ultrathin absorbers. We perform a design of such absorbers with 50% absorption, which is verified by numerical simulations.

36 MATERIALS SCIENCE↗

Laboratory evaluation of microwave absorption properties under simulated conditions for planetary atmospheres

The microwave absorbing properties of gaseous sulfuric acid (H2SO4) under Venus atmospheric conditions are investigated. The results are applied to measurements from Mariner 5, Mariner 10, and Pioneer/Venus Radio Occultation experiments, to determine abundancies of gaseous sulfuric acid in the Venus atmosphere. The microwave properties of the vapors accompanying liquid H2SO4 are studied to estimate the vapor pressure in an atmospheric model.

Steffes, P. G.↗

Laboratory evaluation and application of microwave absorption properties under simulated conditions for planetary atmospheres

Laboratory measurements of microwave and millimeter wave properties of the simulated atmosphere of the outer planets and their satellites has continued. One of the focuses is on the development of a radiative transfer model of the Jovian atmosphere at wavelengths from 1 mm to 10 cm. This modeling effort led to laboratory measurements of the millimeter wave opacity of hydrogen sulfide (H2S) under simulated Jovian conditions. Descriptions of the modeling effort, the Laboratory experiment, and the observations are presented. Correlative studies of measurements with Pioneer-Venus radio occultation measurements with longer wavelength emission measurements have provided new ways for characterizing temporal and spatial variations in the abundance of both gases H2SO4 and SO2, and for modeling their roles in the subcloud atmosphere. Laboratory measurements were conducted on 1.35 cm (and 13 cm) opacity of gaseous SO2 and absorptivity of gaseous SO2 at the 3.2 mm wavelength under simulated Venus conditions. Laboratory measurements were completed on millimeter wave dielectric properties of liquid H2SO4, in order to model the effects of the opacity of the clouds of Venus onto millimeter wave emission spectrum.

Steffes, Paul G.↗

Laboratory measurements of microwave absorption from gaseous atmospheric constituents under conditions for the outer planets

Quite often the interpretive work on the microwave and millimeter-wave absorption profiles, which are inferred from radio occultation measurements or radio astronomical observations of the outer planets, employs theoretically-derived absorption coefficients to account for contributions to the observed opacity from gaseous constituents. Variations of the actual absorption coefficients from those which are theoretically derived, especially under the environmental conditions characteristic of the outer planets, can result in significant errors in the inferred abundances of the absorbing constituents. The recognition of the need to make laboratory measurements of the absorptivity of gases such as NH3, CH4, and H2O in a predominantly H2 atmosphere, under temperature and pressure conditions simulating the outer planets' atmospheres, and at wavelengths corresponding to both radio occultation and radio astronomical observations, has led to the development of a facility capable of making such measurements at Georgia Tech. The laboratory measurement system, the measurement techniques, and the proposed experimental regimen for Winter 1985 are described.

Steffes, Paul G.↗

Laboratory evaluation and application of microwave absorption properties under simulated conditions for planetary atmospheres

Laboratory measurements were conducted to evaluate properties of atmospheric gases under simulated conditions for the outer planets. A significant addition to this effort was the capability to make such measurements at millimeter wavelengths. Measurements should soon be completed on the millimeter wave absorption from ammonia under Jovian conditions. Also studied will be the feasibility of measuring the microwave and millimeter wave properties of phosphine (PH3) under simulated Jovian conditions. Further analysis and application of the laboratory results to microwave and millimeter wave absorption data for the outer planet, such as Voyager Radio Occultation experiments, will be pursued.

Steffes, Paul G.↗