Search NASA⌕ Search

SEARCH · Search NASA

Results for “Modal Test and Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Modal Survey of ETM-3, A 5-Segment Derivative of the Space Shuttle Solid Rocket Booster

The complex interactions between internal motor generated pressure oscillations and motor structural vibration modes associated with the static test configuration of a Reusable Solid Rocket Motor have potential to generate significant dynamic thrust loads in the 5-segment configuration (Engineering Test Motor 3). Finite element model load predictions for worst-case conditions were generated based on extrapolation of a previously correlated 4-segment motor model. A modal survey was performed on the largest rocket motor to date, Engineering Test Motor #3 (ETM-3), to provide data for finite element model correlation and validation of model generated design loads. The modal survey preparation included pretest analyses to determine an efficient analysis set selection using the Effective Independence Method and test simulations to assure critical test stand component loads did not exceed design limits. Historical Reusable Solid Rocket Motor modal testing, ETM-3 test analysis model development and pre-test loads analyses, as well as test execution, and a comparison of results to pre-test predictions are discussed.

Nielsen, D.↗

International Space Station Modal Correction Analysis

This paper summarizes the on-orbit modal test and the related modal analysis, model validation and correlation performed for the ISS Stage ULF4, DTF S4-1A, October 11,2010, GMT 284/06:13:00.00. The objective of this analysis is to validate and correlate analytical models with the intent to verify the ISS critical interface dynamic loads and improve fatigue life prediction. For the ISS configurations under consideration, on-orbit dynamic responses were collected with Russian vehicles attached and without the Orbiter attached to the ISS. ISS instrumentation systems that were used to collect the dynamic responses during the DTF S4-1A included the Internal Wireless Instrumentation System (IWIS), External Wireless Instrumentation System (EWIS), Structural Dynamic Measurement System (SDMS), Space Acceleration Measurement System (SAMS), Inertial Measurement Unit (IMU) and ISS External Cameras. Experimental modal analyses were performed on the measured data to extract modal parameters including frequency, damping and mode shape information. Correlation and comparisons between test and analytical modal parameters were performed to assess the accuracy of models for the ISS configuration under consideration. Based on the frequency comparisons, the accuracy of the mathematical models is assessed and model refinement recommendations are given. Section 2.0 of this report presents the math model used in the analysis. This section also describes the ISS configuration under consideration and summarizes the associated primary modes of interest along with the fundamental appendage modes. Section 3.0 discusses the details of the ISS Stage ULF4 DTF S4-1A test. Section 4.0 discusses the on-orbit instrumentation systems that were used in the collection of the data analyzed in this paper. The modal analysis approach and results used in the analysis of the collected data are summarized in Section 5.0. The model correlation and validation effort is reported in Section 6.0. Conclusions and recommendations drawn from this analysis are included in Section 7.0.

Fotz[atrocl. Lrostom↗

Operational Modal Analysis of the Artemis I Dynamic Rollout Test and Wet Dress Rehearsal

NASA has developed an expendable heavy lift launch vehicle capability, the Space Launch System (SLS), to support lunar and deep space exploration. The uncrewed Artemis I was the first flight of this new launch vehicle and tested critical systems for the upcoming crewed Artemis II flight to the moon. Accelerations were recorded at a multitude of locations on Artemis, the Mobile Launcher (ML), and the Crawler Transporter (CT)during the rollout of Artemis I from the Vehicle Assembly Building (VAB) to Launch Pad 39B March 2022 and is referred to as the Artemis I Dynamic Rollout Test (DRT). While Artemis I was at Launch Pad 39B, the Wet Dress Rehearsal (WDR) was performed to demonstrate launch readiness and acceleration measurements were also recorded. Finally, Artemis I rolled back from Launch Pad 39B to the VAB in April 2022, where acceleration measurements were also recorded and is referred to as the rollback portion of DRT. Because the forces during rollout and at the launch pad acting on Artemis I, the ML, and the CT are not directly measurable, Operational Modal Analysis (OMA) techniques, instead of traditional Experimental Modal Analysis (EMA) techniques, were used to identify modal characteristics. The OMA analysis of DRT and WDR directly builds upon the lessons learned from the OMA analysis of an earlier rollout of the ML from the VAB. DRT and WDR dynamic characteristics will be used to support SLS Integrated Modal Test finite element model correlation efforts and Exploration Ground System ML and CT finite element model verification and validation, which are part of the Building Block approach the Space Launch System program has implemented. The dynamic characteristics extracted from DRT as well as the rollout acceleration time histories themselves will be used in the development of generic rollout forcing functions that will provide refined estimates of the Artemis IV rollout forces, which will have the heavier and larger SLS Block 1B launch vehicle and Mobile Launcher 2 (ML-2). This paper briefly describes Artemis I, the ML, and the CT physical characteristics, DRT rollout/rollback and WDR data collection, the challenges in implementing OMA techniques due in part to the CT harmonics, and how these challenges were overcome to obtain the Artemis I DRT configuration and WDR configuration modal characteristics.

Apollo↗

Operational Modal Analysis of the Artemis I Dynamic Rollout Test and Wet Dress Rehearsal

NASA has developed an expendable heavy lift launch vehicle capability, the Space Launch System (SLS), to support lunar and deep space exploration. The uncrewed Artemis I was the first flight of this new launch vehicle and tested critical systems for the upcoming crewed Artemis II flight to the moon. Accelerations were recorded at a multitude of locations on Artemis, the Mobile Launcher (ML), and the Crawler Transporter (CT)during the rollout of Artemis I from the Vehicle Assembly Building (VAB) to Launch Pad 39B March 2022 and is referred to as the Artemis I Dynamic Rollout Test (DRT). While Artemis I was at Launch Pad 39B, the Wet Dress Rehearsal (WDR) was performed to demonstrate launch readiness and acceleration measurements were also recorded. Finally, Artemis I rolled back from Launch Pad 39B to the VAB in April 2022, where acceleration measurements were also recorded and is referred to as the rollback portion of DRT. Because the forces during rollout and at the launch pad acting on Artemis I, the ML, and the CT are not directly measurable, Operational Modal Analysis (OMA) techniques, instead of traditional Experimental Modal Analysis (EMA) techniques, were used to identify modal characteristics. The OMA analysis of DRT and WDR directly builds upon the lessons learned from the OMA analysis of an earlier rollout of the ML from the VAB. DRT and WDR dynamic characteristics will be used to support SLS Integrated Modal Test finite element model correlation efforts and Exploration Ground System ML and CT finite element model verification and validation, which are part of the Building Block approach the Space Launch System program has implemented. The dynamic characteristics extracted from DRT as well as the rollout acceleration time histories themselves will be used in the development of generic rollout forcing functions that will provide refined estimates of the Artemis IV rollout forces, which will have the heavier and larger SLS Block 1B launch vehicle and Mobile Launcher 2 (ML-2). This paper briefly describes Artemis I, the ML, and the CT physical characteristics, DRT rollout/rollback and WDR data collection, the challenges in implementing OMA techniques due in part to the CT harmonics, and how these challenges were overcome to obtain the Artemis I DRT configuration and WDR configuration modal characteristics.

Apollo↗

Independent Analysis of the Space Station Node Modal Test Data

With complex structures, comparison of independently derived sets of experimental modal parameters is an excellent way to increase confidence in the results. This paper presents modal identification results using the Eigensystem Realization Algorithm (ERA) on frequency response functions from the modal test of the Space Station Resource Node. The Resource Node is the first U.S.-built structure for the International Space Station. The modal test was conducted by the NASA Marshall Space Flight Center (MSFC) in January 1997 for the Boeing Company, who designed and built the Node. The ERA-calculated parameters are compared with independent results obtained by the MSFC test team using commercial software. There was excellent correlation of mode shapes between the two sets of results for the first 21 vibration modes of the structure up to 35 Hz. From 35 to 50 Hz, about 60 percent of 25 additional modes had excellent correlation. Natural frequencies and damping factors of most modes agreed within 0.1 Hz and 0.2 percent, respectively.

Pappa, Richard S.↗

Ground Vibration Test Planning and Pre-Test Analysis for the X-33 Vehicle

This paper describes the results of the modal test planning and the pre-test analysis for the X-33 vehicle. The pre-test analysis included the selection of the target modes, selection of the sensor and shaker locations and the development of an accurate Test Analysis Model (TAM). For target mode selection, four techniques were considered, one based on the Modal Cost technique, one based on Balanced Singular Value technique, a technique known as the Root Sum Squared (RSS) method, and a Modal Kinetic Energy (MKE) approach. For selecting sensor locations, four techniques were also considered; one based on the Weighted Average Kinetic Energy (WAKE), one based on Guyan Reduction (GR), one emphasizing engineering judgment, and one based on an optimum sensor selection technique using Genetic Algorithm (GA) search technique combined with a criteria based on Hankel Singular Values (HSV's). For selecting shaker locations, four techniques were also considered; one based on the Weighted Average Driving Point Residue (WADPR), one based on engineering judgment and accessibility considerations, a frequency response method, and an optimum shaker location selection based on a GA search technique combined with a criteria based on HSV's. To evaluate the effectiveness of the proposed sensor and shaker locations for exciting the target modes, extensive numerical simulations were performed. Multivariate Mode Indicator Function (MMIF) was used to evaluate the effectiveness of each sensor & shaker set with respect to modal parameter identification. Several TAM reduction techniques were considered including, Guyan, IRS, Modal, and Hybrid. Based on a pre-test cross-orthogonality checks using various reduction techniques, a Hybrid TAM reduction technique was selected and was used for all three vehicle fuel level configurations.

Bedrossian, Herand↗

SLS Integrated Modal Test Uncertainty Quantification using the Hybrid Parametric Variation Method

Uncertainty in structural loading during launch is a significant concern in the development of spacecraft and launch vehicles. Small variations in launch vehicle and payload mode shapes and their interaction can result in significant variation in system loads. In many cases involving large aerospace systems it is difficult, not economical, or impossible to perform a system modal test. However, it is still vital to obtain test results that can be compared with analytical predictions to validate models. Instead, the “Building Block Approach” is used in which system components are tested individually. Component models are correlated and updated to agree as best they can with test results. The Space Launch System consists of a number of components that are assembled into a launch vehicle. Finite element models of the components are developed, reduced to Hurty/Craig-Bampton models and assembled to represent different phases of flight. The only opportunity to obtain modal test data from an assembled Space Launch System will be during the Integrated Modal Test. There is always uncertainty in every model, which flows into uncertainty in predicted system results. Uncertainty Quantification is used to determine statistical bounds on prediction accuracy based on model uncertainty. For the Space Launch System, model uncertainty is at the Hurty/Craig-Bampton component level. Uncertainty in the Hurty/Craig-Bampton components is quantified using the hybrid parametric variation approach that combines parametric and nonparametric uncertainty. Uncertainty in model form is one of the biggest contributors to uncertainty in complex built-up structures. This type of uncertainty cannot be represented by variations infinite element model input parameters and thus cannot be included in a parametric approach. However, model-form uncertainty can be modeled using a nonparametric approach based on random matrix theory. The hybrid parametric variation method requires the selection of dispersion values for the Hurty/Craig-Bampton fixed-interface eigenvalues, and the Hurty/Craig-Bampton stiffness matrices. Component test/analysis frequency error is used to identify the fixed-interface eigenvalue dispersions, while test/analysis cross-orthogonality is used to identify stiffness dispersion values. The hybrid parametric variation uncertainty quantification approach is applied to the Space Launch System Integrated Modal Test configuration. Monte Carlo analysis is performed, and statistics are determined for modal correlation metrics, frequency response from Integrated Modal Test shakers to selected accelerometers, as well as other metrics for determining how well target modes are excited and identified. If the predicted uncertainty envelopes future Integrated Modal Test results, then there will be increased confidence in the utility of the component-based hybrid parametric variation uncertainty quantification approach.

Uncertainty Quantification↗

Illustration of the use of modal assurance criterion to detect structural changes in an Orbiter test specimen

The analysis of empirical modal models of structural components using techniques based on the modal assurance criterion (MAC) defined by Ewins (1984) is discussed and demonstrated for the case of the Space Shuttle Orbiter aft bulkhead. Modal models of the bulkhead are constructed before and after environmental acoustic tests equivalent to 30 or 100 missions and compared (by computing their MACs) to detect significant structural changes; subdivision of the modal vector followed by computation of the MAC for each part is used to localize the changes. Numerical data demonstrating the usefulness of the MAC approach are presented in tables and diagrams.

West, Walter M.↗

Experimental and analytical generic space station dynamic models

A dynamic model used for verification of analytical and experimental methods is documented. The model consists of five substructures to simulate the multibody, low frequency nature of large space structures. Design considerations which led to a fundamental vibration frequency of less than one Hz are described. Finite element analysis used to predict the vibration modes and frequencies of the experimental model is presented. In addition, modeling of cable suspension effects using prestressed vibration analysis is described. Details of the expermental and analytical models are included to permit replication of the study. Results of the modal vibration tests and analysis are presented in a separate document.

Belvin, W. K.↗

MODAL FREQUENCY TRACKING: Performance Analysis on Noisy Experimental Ground Test Data

Mechanical devices operating in an environment contaminated by noise, uncertainties, and extraneous disturbances lead to low signal-to-noise-ratios creating an extremely challenging signal processing problem—especially for on-line, realtime, in-flight application. In this report, we discuss a model-based approach to incorporate physical device features into a dynamic structure that can be used to perform on-line tracking of modal frequencies. The approach we take, after pre-processing the raw measurement data, is to obtain a representation of the structural device under test that captures its underlying response to a suite of excitations and operating conditions. One approach is to apply modern system identification techniques based on stochastic subspace methods capable of both: (1) identifying the underlying black-box structure enabling the extraction of structural modes that can be used for analysis; and (2) modal tracking under continued vibrational excitation as in a real-time, in-flight like environment. The vibrational signature of the structural device is measured directly using a suite of tri-axial accelerometers characterizing a multiple input/multiple output (MIMO) dynamic system. In this analysis, we have 15 tri-axial accelerometer measurements or 45 total output channels along with a single excitation also measured with a tri-axial accelerometer providing a 3-input system for processing. We initially describe the experiment and then briefly develop the necessary background in stochastic subspace realization, discuss the algorithm and apply it to the isolated structural device, first, characterized by the set of noisy MIMO accelerometer measurements extracting the modal model from the data (subspace identification), extract the unique modal frequencies (modal coordinate transformation), track their evolution (real-time tracker) to evaluate the overall performance of the processor. Next we evaluate processor performance when the structural device is incorporated into a flight vehicle for further performance analysis. We summarize the results and predict performance.

42 ENGINEERING↗

Application of Quasi-Static Modal Analysis to an Orion Multi-Purpose Crew Vehicle Test

Bolted structural joints often exhibit load-dependent stiffness and energy dissipation that leads to nonlinear, amplitude dependent frequency and damping in the structure. As an alternative to direct integration of the nonlinear equations of motion, quasi-static modal analysis (QSMA) determines the dependence of frequency and damping on response amplitude using loading behavior from nonlinear static analyses. QSMA has previously been demonstrated to substantially reduce computational cost and maintain accuracy relative to full nonlinear dynamic simulation. This work explores the applicability of QSMA to a complex, large-scale aerospace structure. QSMA is employed to analyze a nonlinear model of test hardware developed to support the Orion Multi-Purpose Crew Vehicle program, which exhibited nonlinear behavior during dynamic testing at flight-like load levels. In addition to the extraction of amplitude-dependent frequency and damping curves, a Bouc-Wen hysteresis model was used in conjunction with the quasi-static results to develop nonlinear, uncoupled, time-domain modal equations of motion for the structure. Excellent agreement was observed between the reduced and full-order nonlinear models, encouraging future employment of QSMA to support accurate and efficient model reduction of structures with bolted joint nonlinearities.

QSMA↗

Stability, Visibility, and Histologic Analysis of a New Implanted Fiducial for Use as a Kilovoltage Radiographic or Radioactive Marker for Patient Positioning and Monitoring in Radiotherapy

Purpose: To analyze the stability, visibility, and histology of a novel implantable soft-tissue marker (nonradioactive and radioactive) implanted in dog prostate and rabbit liver. Methods and Materials: A total of 34 nonradioactive and 35 radioactive markers were implanted in 1 dog and 16 rabbits. Stability was assessed by measuring intermarker distance (IMD) variation relative to IMDs at implantation. The IMDs were measured weekly for 4 months in the dog and biweekly for 2-4 weeks in the rabbits. Ultrasound and X-ray imaging were performed on all subjects. Computed tomography and MRI were performed on the dog. Histologic analysis was performed on the rabbits after 2 or 4 months. Results: A total of 139 measurements had a mean ({+-} SD) absolute IMD variation of 1.1 {+-} 1.1 mm. These IMD variations are consistent with those reported in the literature as due to random organ deformation. The markers were visible, identifiable, and induced minimal or no image artifacts in all tested imaging modalities. Histologic analysis revealed that all pathologic changes were highly localized and not expected to be clinically significant. Conclusions: The markers were stable from the time of implantation. The markers were found to be compatible with all common medical imaging modalities. The markers caused no significant histologic effects. With respect to marker stability, visibility, and histologic analysis these implanted fiducials are appropriate for soft-tissue target positioning in radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical challenges involved in supporting the Lambda Point Experiment

The Lambda Point Experiment (LPE) is one of the instruments included in the U.S. Microgravity Payload Mission 1 planned for one of the Space Shuttle flights in 1992. The objective of the experiment is to measure the heat capacity of liquid helium within a narrow interval around the transition between superfluid and normal helium (the lambda point) with an unprecedented temperature resolution of about 10 to the -10th. Multiple technical challenges are presented in the areas of structural support, safety analysis, and modal frequency tests. This paper describes the technical challenges of JPL's multidisciplinary involvement in support of these experiments in microgravity.

Petrac, D.↗

A hybrid approach to test-analysis-model development for large space structures

The present FEM reduction method for the generation of test-analysis-models (TAMs) in test-analysis correlation addresses contentions that the current modal TAM is hypersensitive to differences between test model shapes and analysis mode shapes, thereby generating large off-diagonal terms within the orthogonality and cross-orthogonality matrices employed in test-analysis mode-shape correlation. A hybrid TAM methodology is accordingly developed which combines the exact representation of the FEM target modes from the modal TAM with the more accurate TAM representation of the residual modes; the superior residual dynamics representation of the hybrid TAM is demonstrated for a detailed representation of a large space structure.

Kammer, D. C.↗

Simulated Bladed MMC Disk LCF Validation

The goal of this program was to evaluate the low cycle fatigue behavior of an SCS-6/Ti-6Al-4V sub-component under bi-axial loading conditions at 316 C(600 F). A simulated bladed TMC disk was designed having thirty four blades representing the number that would be used in Allied Signal's JTAGG II impeller. The outer diameter of the bladed ring was 254 mm (10.0 inch) and the inner diameter 114.3 mm (4.50 inch). The outer and inner diameter of the composite zone was 177.8 mm (7.00 inch) and 127.O mm(5.00 inch) respectively. Stress analysis showed that the fatigue life of the bladed composite ring would be about 12000 cycles for the test conditions applied. A modal analysis was conducted which showed that the blades would have sufficient life margin from dynamic excitation. The arbor design was the same as that employed in the spin-to burst test of NAS3-27027. A systematic stress analysis of each part making up the arbor was undertaken to assure the design would meet the low cycle fatigue requirements of the program. The Textron Systems grooved foil-fiber process was chosen to make the SCS-6/Ti-6Al-4V core ring based on the success they had in contract NAS3-27027. Fiber buckling, however, was observed at several locations in the first ring made which rendered it unsuitable for spin testing. The fiber buckling was attributed to cracking of the graphite tooling during the consolidation process. On this basis a second ring was made but it too contained fiber buckling defects. Analysis by Textron indicated that the fiber buckling was most likely due to poor placement of the SCS-6 fiber in the etched grooves of the Ti-6Al-4V foil. This was also a contributor to the defects in the first ring. Since there was little indication of control in the process to manufacture a quality ring a third attempt at making a ring was not undertaken.

Merrick, H. F.↗

Design, Instrumentation, and Data Analysis for the SLS Core Stage Green Run Test Series

The Space Launch System (SLS) Core Stage (CS) Thrust Vector Control (TVC) system is comprised of eight mechanical feedback Shuttle heritage Type III TVC actuators and four RS-25 engines, each attached to a Shuttle heritage gimbal block/bearing. The actuators are powered by a Shuttle-derived hydraulic Core Auxiliary Power Unit (CAPU), and integrated with an all-new Core Stage thrust structure. The actuators are interfaced to the SLS Vehicle Management (VM) software via an all-new TVC Actuator Control (TAC) avionics subsystem. Despite the significant test and flight experience of the Shuttle hardware, the SLS Green Run ambient and hot fire test activities revealed a number of new findings associated with the dynamic response of the TVC integrated system. Test responses suggested that the TVC system did not meet its performance specifications and its step and frequency responses exhibited unexpected departures from prior lab tests and modeled behavior. This paper is the fifth installment in a seven-paper series surveying the design, engineering, test validation, and flight performance of the Core Stage Thrust Vector Control system. In this paper, the design of the TVC analyses conducted during the Core Stage Green Run test series are discussed in detail. Throughout the course of the test activities, the SLS flight control team worked diligently with the Core Stage contractor to revise test command profiles and ensure sufficient instrumentation was available to collect data. Post-test analysis combined the Green Run modal, ambient, and hot fire test data, MSFC 2- axis Core Stage TVC Inertial Load Simulator (ILS) data, Hardware-In-the-Loop (HWIL) Systems Integration Lab (SIL) results, and actuator Acceptance Testing Procedure (ATP) responses. These data were used to characterize the response, validate critical math models of the TVC subsystem, and isolate the probable cause of the unexpected responses. Through comprehensive analysis of the available test data sources, the integrated team identified the dominant contributors to the observed response and developed test-correlated rationale for vehicle flight control system performance, ultimately leading to a confident posture for the Artemis I mission.

John H. Wall↗