Search NASA⌕ Search

SEARCH · Search NASA

Results for “Motion Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Relationship Between Vortex Meander and Ambient Turbulence

Efforts are currently underway to increase the capacity of airports by use of closely-spaced parallel runways. If such an objective is to be achieved safely and efficiently during both visual and instrument flight conditions, it will be necessary to develop more precise methods for the prediction of the motion and spread of the hazard posed by the lift-generated vortex-wakes of aircraft, and their uncertainties. The purpose of the present study is to relate the motion induced in vortex filaments by turbulence in the ambient flow field to the measured turbulence in the flow field. The problem came about when observations made in the two largest NASA wind tunnels indicated that extended exposure of vortex wakes to the turbulence in the wind tunnel air stream causes the centers of the vortices to meander about with time at a given downstream station where wake measurements are being made. Although such a behavior was expected, the turbulence level based on the maximum amplitude of meander was much less than the root-mean-squared value measured in the free-stream of the wind tunnel by use of hot-film anemometers. An analysis of the time-dependent motion of segments of vortex filaments as they interact with an eddy, indicates that the inertia of the filaments retards their motion enough in the early part of their travel to account for a large part of the difference in the two determinations of turbulence level. Migration of vortex filaments from one turbulent eddy to another (probably with a different orientation), is believed to account for the remainder of the difference. Methods that may possibly be developed for use in the measurement of the magnitude of the more intense eddies in turbulent flow fields and how they should be adjusted to predict vortex meander are then discussed.

Rossow, Vernon J.↗

Fluctuation suppression in microgels by polymer electrolytes

Structural details of thermoresponsive, cationically poly(N-iso-propylacrylamide-co-methacrylamido propyl trimethyl ammonium chloride) microgels and the influence of the anionic electrolyte polystyrene sulfonate (PSS) on the internal structure and dynamics of the cationic microgels have been studied with a combination of small angle neutron scattering (SANS) and neutron spin echo (NSE) spectroscopy. While SANS can yield information on the overall size of the particles and on the typical correlation length inside the particles, studying the segmental polymer dynamics with NSE gives access to more internal details, which only appear due to their effect on the polymer motion. The segmental dynamics of the microgels studied in this paper is to a large extent suppressed by the PSS additive. Possible scenarios of the influence of the polyanions on the microgel structure and dynamics are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wavefront Compensation Segmented Mirror Sensing and Control

The primary mirror of very large submillimeter-wave telescopes will necessarily be segmented into many separate mirror panels. These panels must be continuously co-phased to keep the telescope wavefront error less than a small fraction of a wavelength, to ten microns RMS (root mean square) or less. This performance must be maintained continuously across the full aperture of the telescope, in all pointing conditions, and in a variable thermal environment. A wavefront compensation segmented mirror sensing and control system, consisting of optical edge sensors, Wavefront Compensation Estimator/Controller Soft ware, and segment position actuators is proposed. Optical edge sensors are placed two per each segment-to-segment edge to continuously measure changes in segment state. Segment position actuators (three per segment) are used to move the panels. A computer control system uses the edge sensor measurements to estimate the state of all of the segments and to predict the wavefront error; segment actuator commands are computed that minimize the wavefront error. Translational or rotational motions of one segment relative to the other cause lateral displacement of the light beam, which is measured by the imaging sensor. For high accuracy, the collimator uses a shaped mask, such as one or more slits, so that the light beam forms a pattern on the sensor that permits sensing accuracy of better than 0.1 micron in two axes: in the z or local surface normal direction, and in the y direction parallel to the mirror surface and perpendicular to the beam direction. Using a co-aligned pair of sensors, with the location of the detector and collimated light source interchanged, four degrees of freedom can be sensed: transverse x and y displacements, as well as two bending angles (pitch and yaw). In this approach, each optical edge sensor head has a collimator and an imager, placing one sensor head on each side of a segment gap, with two parallel light beams crossing the gap. Two sets of optical edge sensors are used per segment-to-segment edge, separated by a finite distance along the segment edge, for four optical heads, each with an imager and a collimator. By orienting the beam direction of one edge sensor pair to be +45 away from the segment edge direction, and the other sensor pair to be oriented -45 away from the segment edge direction, all six degrees of freedom of relative motion between the segments can be measured with some redundancy. The software resides in a computer that receives each of the optical edge sensor signals, as well as telescope pointing commands. It feeds back the edge sensor signals to keep the primary mirror figure within specification. It uses a feed-forward control to compensate for global effects such as decollimation of the primary and secondary mirrors due to gravity sag as the telescope pointing changes to track science objects. Three segment position actuators will be provided per segment to enable controlled motions in the piston, tip, and tilt degrees of freedom. These actuators are driven by the software, providing the optical changes needed to keep the telescope phased.

Redding, David C.↗

WE-B-BRD-00: MRI for Radiation Oncology

The use of MRI in radiation therapy is rapidly increasing. Applications vary from the MRI simulator, to the MRI fused with CT, and to the integrated MRI+RT system. Compared with the standard MRI QA, a broader scope of QA features has to be defined in order to maximize the benefits of using MRI in radiation therapy. These QA features include geometric fidelity, image registration, motion management, cross-system alignment, and hardware interference. Advanced MRI techniques require a specific type of QA, as they are being widely used in radiation therapy planning, dose calculations, post-implant dosimetry, and prognoses. A vigorous and adaptive QA program is crucial to defining the responsibility of the entire radiation therapy group and detecting deviations from the performance of high-quality treatment. As a drastic departure from CT simulation, MRI simulation requires changes in the work flow of treatment planning and image guidance. MRI guided radiotherapy platforms are being developed and commercialized to take the advantage of the advance in knowledge, technology and clinical experience. This symposium will from an educational perspective discuss the scope and specific issues related to MRI guided radiotherapy. Learning Objectives: Understand the difference between a standard and a radiotherapy-specific MRI QA program. Understand the effects of MRI artifacts (geometric distortion and motion) on radiotherapy. Understand advanced MRI techniques (ultrashort echo, fast MRI including dynamic MRI and 4DMRI, diffusion, perfusion, and MRS) and related QA. Understand the methods to prepare MRI for treatment planning (electron density assignment, multimodality image registration, segmentation and motion management). Current status of MRI guided treatment platforms. Dr. Jihong Wang has a research grant with Elekta-MRL project. Dr. Ke Sheng receives research grants from Varian Medical systems.

60 APPLIED LIFE SCIENCES↗

WE-B-BRD-01: MR-LINAC

The use of MRI in radiation therapy is rapidly increasing. Applications vary from the MRI simulator, to the MRI fused with CT, and to the integrated MRI+RT system. Compared with the standard MRI QA, a broader scope of QA features has to be defined in order to maximize the benefits of using MRI in radiation therapy. These QA features include geometric fidelity, image registration, motion management, cross-system alignment, and hardware interference. Advanced MRI techniques require a specific type of QA, as they are being widely used in radiation therapy planning, dose calculations, post-implant dosimetry, and prognoses. A vigorous and adaptive QA program is crucial to defining the responsibility of the entire radiation therapy group and detecting deviations from the performance of high-quality treatment. As a drastic departure from CT simulation, MRI simulation requires changes in the work flow of treatment planning and image guidance. MRI guided radiotherapy platforms are being developed and commercialized to take the advantage of the advance in knowledge, technology and clinical experience. This symposium will from an educational perspective discuss the scope and specific issues related to MRI guided radiotherapy. Learning Objectives: Understand the difference between a standard and a radiotherapy-specific MRI QA program. Understand the effects of MRI artifacts (geometric distortion and motion) on radiotherapy. Understand advanced MRI techniques (ultrashort echo, fast MRI including dynamic MRI and 4DMRI, diffusion, perfusion, and MRS) and related QA. Understand the methods to prepare MRI for treatment planning (electron density assignment, multimodality image registration, segmentation and motion management). Current status of MRI guided treatment platforms. Dr. Jihong Wang has a research grant with Elekta-MRL project. Dr. Ke Sheng receives research grants from Varian Medical systems.

60 APPLIED LIFE SCIENCES↗

WE-B-BRD-02: MR Simulation for Radiation Therapy

The use of MRI in radiation therapy is rapidly increasing. Applications vary from the MRI simulator, to the MRI fused with CT, and to the integrated MRI+RT system. Compared with the standard MRI QA, a broader scope of QA features has to be defined in order to maximize the benefits of using MRI in radiation therapy. These QA features include geometric fidelity, image registration, motion management, cross-system alignment, and hardware interference. Advanced MRI techniques require a specific type of QA, as they are being widely used in radiation therapy planning, dose calculations, post-implant dosimetry, and prognoses. A vigorous and adaptive QA program is crucial to defining the responsibility of the entire radiation therapy group and detecting deviations from the performance of high-quality treatment. As a drastic departure from CT simulation, MRI simulation requires changes in the work flow of treatment planning and image guidance. MRI guided radiotherapy platforms are being developed and commercialized to take the advantage of the advance in knowledge, technology and clinical experience. This symposium will from an educational perspective discuss the scope and specific issues related to MRI guided radiotherapy. Learning Objectives: Understand the difference between a standard and a radiotherapy-specific MRI QA program. Understand the effects of MRI artifacts (geometric distortion and motion) on radiotherapy. Understand advanced MRI techniques (ultrashort echo, fast MRI including dynamic MRI and 4DMRI, diffusion, perfusion, and MRS) and related QA. Understand the methods to prepare MRI for treatment planning (electron density assignment, multimodality image registration, segmentation and motion management). Current status of MRI guided treatment platforms. Dr. Jihong Wang has a research grant with Elekta-MRL project. Dr. Ke Sheng receives research grants from Varian Medical systems.

60 APPLIED LIFE SCIENCES↗

WE-B-BRD-03: MR QA/QC for MRgRT

The use of MRI in radiation therapy is rapidly increasing. Applications vary from the MRI simulator, to the MRI fused with CT, and to the integrated MRI+RT system. Compared with the standard MRI QA, a broader scope of QA features has to be defined in order to maximize the benefits of using MRI in radiation therapy. These QA features include geometric fidelity, image registration, motion management, cross-system alignment, and hardware interference. Advanced MRI techniques require a specific type of QA, as they are being widely used in radiation therapy planning, dose calculations, post-implant dosimetry, and prognoses. A vigorous and adaptive QA program is crucial to defining the responsibility of the entire radiation therapy group and detecting deviations from the performance of high-quality treatment. As a drastic departure from CT simulation, MRI simulation requires changes in the work flow of treatment planning and image guidance. MRI guided radiotherapy platforms are being developed and commercialized to take the advantage of the advance in knowledge, technology and clinical experience. This symposium will from an educational perspective discuss the scope and specific issues related to MRI guided radiotherapy. Learning Objectives: Understand the difference between a standard and a radiotherapy-specific MRI QA program. Understand the effects of MRI artifacts (geometric distortion and motion) on radiotherapy. Understand advanced MRI techniques (ultrashort echo, fast MRI including dynamic MRI and 4DMRI, diffusion, perfusion, and MRS) and related QA. Understand the methods to prepare MRI for treatment planning (electron density assignment, multimodality image registration, segmentation and motion management). Current status of MRI guided treatment platforms. Dr. Jihong Wang has a research grant with Elekta-MRL project. Dr. Ke Sheng receives research grants from Varian Medical systems.

60 APPLIED LIFE SCIENCES↗

Spatial orientation and balance control changes induced by altered gravitoinertial force vectors

To better understand the mechanisms of human adaptation to rotating environments, we exposed 19 healthy subjects and 8 vestibular-deficient subjects ("abnormal"; four bilateral and four unilateral lesions) to an interaural centripetal acceleration of 1 g (resultant 45 degrees roll-tilt of 1.4 g) on a 0.8-m-radius centrifuge for periods of 90 min. The subjects sat upright (body z-axis parallel to centrifuge rotation axis) in the dark with head stationary, except during 4 min of every 10 min, when they performed head saccades toward visual targets switched on at 3- to 5-s intervals at random locations (within +/- 30 degrees) in the earth-horizontal plane. Eight of the normal subjects also performed the head saccade protocol in a stationary chair adjusted to a static roll-tilt angle of 45 degrees for 90 min (reproducing the change in orientation but not the magnitude of the gravitoinertial force on the centrifuge). Eye movements, including voluntary saccades directed along perceived earth- and head-referenced planes, were recorded before, during, and immediately after centrifugation. Postural center of pressure (COP) and multisegment body kinematics were also gathered before and within 10 min after centrifugation. Normal subjects overestimated roll-tilt during centrifugation and revealed errors in perception of head-vertical provided by directed saccades. Errors in this perceptual response tended to increase with time and became significant after approximately 30 min. Motion-sickness symptoms caused approximately 25% of normal subjects to limit their head movements during centrifugation and led three normal subjects to stop the test early. Immediately after centrifugation, subjects reported feeling tilted 10 degrees in the opposite direction, which was in agreement with the direction of their earth-referenced directed saccades. Postural COP, segmental body motion amplitude, and hip-sway frequency increased significantly after centrifugation. These postural effects were short-lived, however, with a recovery time of several postural test trials (minutes). There were also asymmetries in the direction of postcentrifugation COP and head tilt which depended on the subject's orientation during the centrifugation adaptation period (left ear or right ear out). The amount of total head movements during centrifugation correlated poorly or inversely with postcentrifugation postural stability, and the most unstable subject made no head movements. There was no decrease in postural stability after static tilt, although these subjects also reported a perceived tilt briefly after return to upright, and they also had COP asymmetries. Abnormal subjects underestimated roll-tilt during centrifugation, and their directed saccades revealed permanent spatial distortions. Bilateral abnormal subjects started out with poor postural control, but showed no postural decrements after centrifugation, while unilateral abnormal subjects had varying degrees of postural decrement, both in their everyday function and as a result of experiencing the centrifugation. In addition, three unilateral, abnormal subjects, who rode twice in opposite orientations, revealed a consistent orthogonal pattern of COP offsets after centrifugation. These results suggest that both orientation and magnitude of the gravitoinertial vector are used by the central nervous system for calibration of multiple orientation systems. A change in the background gravitoinertial force (otolith input) can rapidly initiate postural and perceptual adaptation in several sensorimotor systems, independent of a structured visual surround.

Clinical Trial↗

Thermally Rearranged Polymer Membranes Containing Tröger's Base Units Have Exceptional Performance for Air Separations

Abstract The influence of segmental chain motion on the gas separation performance of thermally rearranged (TR) polymer membranes is established for TR polybenzoxazoles featuring Tröger's base (TB) monomer subunits as exceptionally rigid sites of contortion along the polymer backbone. These polymers are accessed from solution‐processable ortho‐acetate functionalized polyimides, which are readily synthesized as high‐molecular‐weight polymers for membrane casting. We find that thermal rearrangement leads to a small increase in d‐spacing between polymer chains and a dramatic pore‐network reconfiguration that increases both membrane permeability and O 2 /N 2 selectivity, putting its performance above the 2015 upper bound.

Meckler, Stephen M.↗

Thermally Rearranged Polymer Membranes Containing Tröger's Base Units Have Exceptional Performance for Air Separations

The influence of segmental chain motion on the gas separation performance of thermally rearranged (TR) polymer membranes is established for TR polybenzoxazoles featuring Tröger's base (TB) monomer subunits as exceptionally rigid sites of contortion along the polymer backbone. These polymers are accessed from solution-processable ortho-acetate functionalized polyimides, which are readily synthesized as high-molecular-weight polymers for membrane casting. We discover that thermal rearrangement leads to a small increase in d-spacing between polymer chains and a dramatic pore-network reconfiguration that increases both membrane permeability and O 2 /N 2 selectivity, enabling its performance above the 2015 upper bound.

36 MATERIALS SCIENCE↗

Glassy polymers: Historical findings, membrane applications, and unresolved questions regarding physical aging

Polymers below their glass transition temperature (Tg) are non-equilibrium glasses because excess free volume “frozen” between kinetically-restricted polymer chains slowly relaxes over time towards equilibrium via local, segmental chain motion. This process, known as physical aging, is observed through time-dependent decreases in a polymer's specific volume, enthalpy, etc. This article focuses on the history of glassy polymers in membrane separation applications. Open questions regarding the influence of thickness (e.g., membrane geometry) and temperature on physical aging in glassy polymers are highlighted.

36 MATERIALS SCIENCE↗

Structure and Dynamics of Ionic Block Copolymer Melts: Computational Study

Structure and dynamics of melts of copolymers with an ABCBA topology, where C is an ionizable block, have been studied by fully atomistic molecular dynamics (MD) simulations. Introducing an ionizable block for functionality adds a significant element to the coupled set of interactions that determine the structure and dynamics of the macromolecule. The polymer consists of a randomly sulfonated polystyrene C block tethered to a flexible poly(ethylene-r-propylene) bridge B and end-capped with poly(tert-butylstyrene) A. The chemical structure and topology of these polymers constitute a model for incorporation of ionic blocks within a framework that provides tactility and mechanical stability. Here in this paper we resolve the structure and dynamics of a structured polymer on the nanoscale constrained by ionic clusters. We find that the melts form intertwined networks of the A and C blocks independent of the degree of sulfonation of the C block with no long-range order. The cluster cohesiveness and morphology affect both macroscopic translational motion and segmental dynamics of all the blocks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The diffusion and conduction of lithium in poly(ethylene oxide)-based sulfonate ionomers

Pulsed field gradient nuclear magnetic resonance spectroscopy and dielectric relaxation spectroscopy have been utilized to investigate lithium dynamics within poly(ethylene oxide) (PEO)-based lithium sulfonate ionomers of varying ion content. The ion content is set by the fraction of sulfonated phthalates and the molecular weight of the PEO spacer, both of which can be varied independently. The molecular level dynamics of the ionomers are dominated by either Vogel-Fulcher-Tammann or Arrhenius behavior depending on ion content, spacer length, temperature, and degree of ionic aggregation. In these ionomers the main determinants of the self-diffusion of lithium and the observed conductivities are the ion content and ionic states of the lithium ion, which are profoundly affected by the interactions of the lithium ions with the ether oxygens of the polymer. Since many lithium ions move by segmental polymer motion in the ion pair state, their diffusion is significantly larger than that estimated from conductivity using the Nernst-Einstein equation.

LaFemina, Nikki H.↗

Segmented strings and the McMillan map

We present new exact solutions describing motions of closed segmented strings in AdS 3 in terms of elliptic functions. The existence of analytic expressions is due to the integrability of the classical equations of motion, which in our examples reduce to instances of the McMillan map. Here, we also obtain a discrete evolution rule for the motion in AdS 3 of arbitrary bound states of fundamental strings and D1-branes in the test approximation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preliminary Analysis of Effect of Random Segment Errors on Coronagraph Performance

Are we alone in the Universe is probably the most compelling science question of our generation. To answer it requires a large aperture telescope with extreme wavefront stability. To image and characterize Earth-like planets requires the ability to block 10(exp 10) of the host stars light with a 10(exp -11) stability. For an internal coronagraph, this requires correcting wavefront errors and keeping that correction stable to a few picometers rms for the duration of the science observation. This requirement places severe specifications upon the performance of the observatory, telescope and primary mirror. A key task of the AMTD project (initiated in FY12) is to define telescope level specifications traceable to science requirements and flow those specifications to the primary mirror. From a systems perspective, probably the most important question is: What is the telescope wavefront stability specification? Previously, we suggested this specification should be 10 picometers per 10 minutes; considered issues of how this specification relates to architecture, i.e. monolithic or segmented primary mirror; and asked whether it was better to have few or many segmented. This paper reviews the 10 picometers per 10 minutes specification; provides analysis related to the application of this specification to segmented apertures; and suggests that a 3 or 4 ring segmented aperture is more sensitive to segment rigid body motion that an aperture with fewer or more segments.

Stahl, Mark T.↗

Motion coherence affects human perception and pursuit similarly

Pursuit and perception both require accurate information about the motion of objects. Recovering the motion of objects by integrating the motion of their components is a difficult visual task. Successful integration produces coherent global object motion, while a failure to integrate leaves the incoherent local motions of the components unlinked. We compared the ability of perception and pursuit to perform motion integration by measuring direction judgments and the concomitant eye-movement responses to line-figure parallelograms moving behind stationary rectangular apertures. The apertures were constructed such that only the line segments corresponding to the parallelogram's sides were visible; thus, recovering global motion required the integration of the local segment motion. We investigated several potential motion-integration rules by using stimuli with different object, vector-average, and line-segment terminator-motion directions. We used an oculometric decision rule to directly compare direction discrimination for pursuit and perception. For visible apertures, the percept was a coherent object, and both the pursuit and perceptual performance were close to the object-motion prediction. For invisible apertures, the percept was incoherently moving segments, and both the pursuit and perceptual performance were close to the terminator-motion prediction. Furthermore, both psychometric and oculometric direction thresholds were much higher for invisible apertures than for visible apertures. We constructed a model in which both perception and pursuit are driven by a shared motion-processing stage, with perception having an additional input from an independent static-processing stage. Model simulations were consistent with our perceptual and oculomotor data. Based on these results, we propose the use of pursuit as an objective and continuous measure of perceptual coherence. Our results support the view that pursuit and perception share a common motion-integration stage, perhaps within areas MT or MST.

NASA Center ARC↗

Possible breakup of dark terrain on Ganymede by large-scale shear faulting

The questions of relative motions of large segments of Ganymede's lithosphere and of the effect of any motions on grooved terrain formation are reexamined. Resolvable furrows in both hemispheres were mapped in great detail using Voyager 1 and 2 images and U.S. Geological Survey controlled shaded-relief quadrangle maps. Estimates of the Galileo Regio and Marius Regio poles of furrow concentricity indicate a considerable westward offset of the Galileo Regio pole, suggesting the possibility of about 500-km of left-lateral offset of the two areas. There is evidence that shear deformation was concentrated along a major structural lineament which follows a small circle and encloses Galileo Regio, and that a smaller amount of distributed shear occurred across an adjacent 500- to 1500-km-wide band. The results indicate that either widespread shear strain or the shear's driving mechanism may have had a long-term effect on patterns of deformation of Ganymede's lithosphere.

Murchie, Scott L.↗

Dynamics of the lignin glass transition

The dynamics of lignin, a complex and heterogeneous major plant cell-wall macromolecule, is of both fundamental and practical importance. Lignin is typically heated to temperatures above its glass transition to facilitate its industrial processing. Here, we performed molecular dynamics simulations to investigate the segmental (α) relaxation of lignin, the dynamical process that gives rise to the glass transition. It is found that lignin dynamics involves mainly internal motions below T g , while segmental inter-molecular motions are activated above T g . The segments whose mobility is enhanced above T g consist of 3–5 lignin monomeric units. The temperature dependence of the lignin segmental relaxation time changes from Arrhenius below T g to Vogel–Fulcher–Tamman above T g . This change in temperature dependence is determined by the underlying energy landscape being restricted below T g but exhibiting multiple minima above T g . The Q-dependence of the relaxation time is found to obey a power-law up to Q max , indicative of sub-diffusive motion of lignin above T g . Temperature and hydration affect the segmental relaxation similarly. Increasing hydration or temperature leads to: (1) the α process starting earlier, i.e. the beta process becomes shortened, (2) Q max decreasing, i.e. the lengthscale above which subdiffusion is observed increases, and (3) the number of monomers constituting a segment increasing, i.e. the motions that lead to the glass transition become more collective. The above findings provide molecular-level understanding of the technologically important segmental motions of lignin and demonstrate that, despite the heterogeneous and complex structure of lignin, its segmental dynamics can be described by concepts developed for chemically homogeneous polymers.

09 BIOMASS FUELS↗