Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mu2e”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The Mu2e undoped CsI crystal calorimeter

We present the Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The choice of the crystals and SiPMs has been finalized after a thorough test campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in Frascati. Lastly, although the readout electronics were not final, results show that the current design is able to meet the timing and energy resolution required by the Mu2e experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and construction status of the Mu2e electromagnetic calorimeter mechanical structures

Abstract The Mu2e experiment at Fermilab will search for the CLFV neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the evidence of physics beyond the Standard Model. Mu2e comprises a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides electron identification, a fast trigger and aids track reconstruction. It is a state-of-the-art crystal calorimeter and employs 1340 pure CsI crystals readout by UV-extended SiPM and fast electronics. The design consists of two identical annular disks positioned at the relative distance of 70 cm downstream the target.The hostile Mu2e conditions (total ionizing dose of 12 krad and a neutron fluence of 5 × 10 10 n/cm 2 @ 1 MeVeq (Si)/y, 1 T magnetic field and vacuum level of 10 −4 Torr) posed tight constraints on the mechanical structures and materials choice. The support structure of the two crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. SiPMs and front-end electronics for each crystal are assembled in one mechanical unit inserted in a machined copper holder. The units are supported by a plate made of vacuum-compatible material. The plate integrates the cooling system made of a network of copper lines flowing a low temperature fluid and placed in thermal contact with the copper holders. The DAQ is hosted in aluminum crates positioned on the lateral surface of the disks. The crates also integrate the DAQ electronics cooling system. We review the constraints on the calorimeter structures design, the development of all the structural components, including the simulations that have determined the materials and technological choices and the specifications of the cooling station, components production and quality assurance tests, the procedures for detector assembly, transportation and installation in the experimental area.

Instruments & Instrumentation↗

Mu2e Solenoid Field Mapping System Design

The Mu2e experiment at Fermilab plans to search for charged-lepton flavor violation by looking for neutrino-less muon to electron conversion in the field of the nucleus. A complex solenoid system and precise knowledge of its magnetic field play a major role in the experimental approach Mu2e has chosen. It is essential to map the solenoid field up to 10 -4 accuracy. This article describes the design of the Field Mapping System Mu2e will use to measure the magnetic field. Two different mechanical mapper systems, a survey based position determination of the in-house calibrated 3D Hall probes, a motion control system, and a data acquisition and readout system are presented.

43 PARTICLE ACCELERATORS↗

Hall Probe Calibration System Design for the Mu2e Solenoid Field Mapping System

The goal of the Mu2e experiment at Fermilab is to search for charged-lepton flavor violation by looking for neutrino-less muon to electron conversion in the field of the nucleus. The Mu2e experimental apparatus utilizes a complex magnetic field in the muon generation and momentum and charge selection process. Precise knowledge of the magnetic field is crucial. It is planned to map the solenoid field with calibrated 3D Hall probes up to 10 -5 accuracy. Here, this article describes a new design of a Hall probe calibration system that will be used to calibrate 3D Hall probes to better than 10 -5 accuracy for the Mu2e Solenoid Field Mapping System.

43 PARTICLE ACCELERATORS↗

Design and Status of the Mu2e Crystal Calorimeter

The Mu2e experiment at Fermilab searches for the charged-lepton flavour violating (CLFV) conversion of a negative muon into an electron in the field of an aluminum nucleus, with a distinctive signature of a mono-energetic electron of energy slightly below the muon rest mass (104.967 MeV). The Mu2e goal is to improve by four orders of magnitude the search sensitivity with respect to the previous experiments. Any observation of a CLFV signal will be a clear indication of new physics. The Mu2e detector is composed of a tracker, an electro- magnetic calorimeter and an external veto for cosmic rays surrounding the solenoid. The calorimeter plays an important role in providing particle identification capabilities, a fast online trigger filter, a seed for track reconstruction while working in vacuum, in the presence of 1 T axial magnetic field and in an harsh radiation environment. The calorimeter requirements are to provide a large acceptance for 100 MeV electrons and reach at these energies: (a) a time resolution better than 0.5 ns; (b) an energy resolution < 10% and (c) a position resolution of 1 cm. The calorimeter design consists of two disks, each one made of 674 undoped CsI crystals read by two large area arrays of UV-extended SiPMs. We report here the construction and test of the Module-0 prototype. The Module-0 has been exposed to an electron beam in the energy range around 100 MeV at the Beam Test Facility in Frascati. Preliminary results of timing and energy resolution at normal incidence are shown. A discussion of the technical aspects of the calorimeter engineering is also reported in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing a data-driven method to constrain the antiproton background in the Mu2e experiment

The Mu2e experiment will search for CLFV neutrinoless coherent muon to electron conversion in the field of an Al nucleus. The expected signal is a 104.97 MeV/c monochromatic $e^-$ (CE). CE-like $e^-$’s could also come from $\bar{p}$’s annihilating in the Stopping Target (ST). The background induced by $\bar{p}$’s is expected to be low but has a large systematic uncertainty. It cannot be suppressed by the time window cut used to reduce the prompt background. However, $p\bar{p}$ annihilation in the ST is the only source of events in the Mu2e detector with multiple tracks coming from the ST, simultaneous in time, each with a momentum in the signal window region. We exploited this unique feature and developed algorithms to identify and reconstruct multi-track events. This paper discusses the status and prospects of this data-driven method to constrain the $\bar{p}$ background at Mu2e.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Searching for muon to electron conversion: The Mu2e experiment at Fermilab

The Mu2e experiment will measure the charged-lepton flavor violating (CLFV) neutrino-less conversion of a negative muon into an electron in the field of a nucleus. Mu2e will improve the previous measurement by four orders of magnitude, reaching a 90% C.L. limit of 8\times10^{-17} 8 × 10 − 17 on the conversion rate. The experiment will reach mass scales of nearly 10^4 10 4 TeV, far beyond the direct reach of colliders. The experiment is sensitive to a wide range of new physics, complementing and extending other CLFV searches. Mu2e is under design and construction at the Muon Campus of Fermilab; we expect to start taking physics data in 2022 with 3 years of running to achieve our target sensitivity.

Bonventre, Richard↗

Assessment of neutron skyshine near unmodified Accumulator Debuncher storage rings under Mu2e operational conditions

Preliminary plans for providing the proton beam needed by the proposed Mu2e experiment at Fermilab will require the transport of 8 GeV protons to the Accumulator/Debuncher where they be processed into an intensity and time structure useful for the experiment. The intensities involved are far greater that those encountered with antiprotons of the same kinetic energy in the same beam enclosures under Tevatron Collider operational conditions, the operating parameters for which the physical facilities of the Antiproton Source were designed. This note explores some important ramifications of the proposed operation for radiation safety and demonstrates the need for extensive modifications of significant portions of the shielding of the Accumulator Debuncher storage rings; notably that underneath the AP Service Buildings AP10, AP30, and AP50. While existing shielding is adequate for the current operating mode of the Accumulator/Debuncher as part of the Antiproton Source used in the Tevatron Collider program, without significant modifications of the shielding configuration in the Accumulator/Debuncher region and/or beam loss control systems far more effective than seen in most applications at Fermilab, the proposed operational mode for Mu2e is not viable for the following reasons: 1. Due to skyshine alone, under normal operational conditions large areas of the Fermilab site would be exposed to unacceptable levels of radiation where most of the Laboratory workforce and some members of the general public who regularly visit Fermilab would receive measurable doses annually, contrary to workforce, public, and DOE expectations concerning the As Low as Reasonably Achievable (ALARA) principle. 2. Under normal operational conditions, a sizeable region of the Fermilab site would also require fencing due to skyshine. The size of the areas involved would likely invite public inquiry about the significant and visible enlargement of Fermilab's posted radiological areas. 3. There would be aesthetics questions about the employment of so much new fencing on the Fermilab site. 4. The assumption of only 1.0% 'normal condition' beam losses over the three locations is regarded as being extremely optimistic. Thus, it is evident that it is necessary to pursue shielding improvements to support viable operation of the Mu2e experiment.

43 PARTICLE ACCELERATORS↗

Research and Development for the Mu2e Extinction Monitor

Mu2e is a planned experiment to search for flavor-violating conversion from a muon to an electron. The experiment will use a pulsed 8 GeV proton beam to produce muons which will then stop in an aluminum target. Mu2e will search for the $\mu^- + Al \rightarrow e^- + Al$ process. For Mu2e, an extinction rate of 10$^{-10}$ is required to reduce the backgrounds to an acceptable level. Extinction is the ratio of the amount of protons striking the production target between beam pulses to the number striking it during the beam pulse. One of the backgrounds, off-target interactions, was simulated using G4beamline and Fermilab's Grid setup to confirm that an extinction rate of 10$^{-10}$ is possible. The extinction level will be measured by the extinction monitor which will include scintillation counters read out by photomultiplier tubes. In order to build a beam time profile, low fake responses (after pulses) are needed in the photomultiplier tubes. This thesis determines the best combination of resistors, voltage, and other components that provide the lowest after pulse rate.

43 PARTICLE ACCELERATORS↗

Searching for Muon to Electron Conversion: The Mu2e Experiment at Fermilab [PowerPoint]

Mu2e at Fermilab will search for neutrinoless conversion of a muon to an electron in a nuclear environment: μ -N → e -N . This would violate charged lepton flavor, something that has never been seen before. Any detection of charged lepton flavor violation would be an unambiguous sign of new physics. The Mu2e goal is a 10 4 improvement. The specifics and schedule for Mu2e are provided.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charged Lepton Flavor Violation Search on Mu2e at Fermilab [PowerPoint]

The Mu2e experiment at Fermilab is described. Areas covered include: Charged Lepton Flavor Violation (CLFV); CLFV measurements; Muon to electron conversion search on Mu2e; The experimental apparatus; Current status; and, Next plan -- Mu2e II.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Mu2e Experiment at Fermilab

The Muon-to-Electron-Conversion (Mu2e) Experiment is a high-precision, intensity-frontier experiment being developed at Fermilab that will search for coherent, neutrino-less muon to electron conversion in the presence of an atomic nucleus. Such a process would exhibit charged lepton flavor violation (CLFV), which has not yet been observed. Continuing the search for CLFV, Mu2e will improve the sensitivity by four orders of magnitude over the present limits. In the search for beyond the standard model (BSM) physics, Mu2e is uniquely sensitive to a wide range of models by indirectly probing mass scales up to the energy scale of 10^4 TeV. While muon-to-electron-conversion is permissible in an extension of the standard model through neutrino oscillations, the rate is extremely low at about one event in 10^52. By design, the background for the experiment will be well-understood and kept at a sub-event level, which will mean the observation of muon-to-electron conversion is a dire ct confirmation of BSM physics. The physics motivation, the design, and the current status of the experiment will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mu2e - Extinction Monitor Research & Development

Current efforts are being conducted at Fermi National Laboratory to study potential violations in accepted theory that would otherwise suggest a restructuring of our fundamental understanding of the universe. Mu2e is one of these frontier projects that studies charged lepton flavor violation (CLFV) which if observed, would suggest physics beyond the Standard Model. Therefore, this note encompasses several projects that contribute to the fruition of Mu2e investigations. Due to the broad range of disciplinary inconsistencies that each project requires, all the work is being presented as a means of justifying contribution to Mu2e. The projects are comprised of a G4Beamline simulation analyzing 8GeV proton beam interaction with a titanium window of Recycler ring extinction rates using three Cherenkov radiation-based detectors and supplemental work for the implementation of a micro–Telecommunications Computing Architecture (MicroTCA) crate to establish a peak finding algorithm to ensure that the out-of-time beam is less than 10^-10 fractional level along with inefficiency analysis on scintillation counters for the Cosmic-Ray Veto (CRV) analysis. Preliminary results have been achieved for extinction rate simulation by achieving coincidence rates for 2/3-fold and 3/3-fold on the detectors in the order of 10^-9 and 10^-10, respectively. Only preliminary results of a triangular counter and four rectangular di-counters for the CRV have been realized but other non-experimental contributions were made to the development of the MicroTCA crate.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and assembling status of the Mu2e electromagnetic calorimeter mechanical structures

The muon-to-electron conversion (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named disks ) positioned at the relative distance of 70 cm, downstream the aluminum target along the muon beamline, satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5 10^{10} n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10−4 Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 674 crystal matrices employs two aluminum hollow rings and parts made of open- cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 674 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal con- tact with the copper holders. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system. In this poster we will review the constraints on the calorimeter mechanical structures, the technological choices, and the status of assembling at Fermilab.

Pasciuto, D.↗

Commissioning of the Mu2e Data AcQuisition System and the Vertical Slice Test of the Straw Tracker

The report discusses the commissioning of the DAQ system of the Mu2e experiment. We studied how the tracker works and especially the tracker readout. We used a generator to send pulses and we tried to understand the output and non-output of the DTC, in order to validate the event and run format and all the failure modes. In section one, we describe Charged Lepton Flavour Violation, the main purpose of Mu2e, in section two we describe Mu2e experiment. Section three presents the tracker description and readout, meanwhile section four the DAQ system and event building. In section five, we start explaining the analysis we have done on events and all the failure modes we discovered. In section six, we have done an analysis of the logger and boardreader rate, we validated the generator frequency in section seven and studied the number of hits in function of the channel number in section eight. To conclude we investigated the channel to channel time differences in section nine and in section ten we explain our Monte Carlo simulation, reproducing ROCs readout.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the gas gain and understanding the gas flow in the Mu2e Tracker

The Mu2e experiment will search for the charged-lepton flavor violating (CLFV) neutrinoless conversion of a negative muon into an electron in the field of an Aluminum nucleus µ − N → e − N. The signature of this process is the emission of a monochromatic electron with an energy of 104.97 MeV. The Mu2e Tracker is a low mass straw tube detector, whose aim is to measure the position and the momentum of the electron. In past measurements, high values of currents were found in some panels of the Tracker in absence of any radioactive sources. In this report new measurements of currents, that were taken with the panel MN084 of the Mu2e Tracker are described. Moreover, the addition of a small amount of water vapour in the gas mixture and the influence of the environmental conditions on the currents of the panel are studied.

47 OTHER INSTRUMENTATION↗

Fermilab 2025 Summer Internship: Repairing Pre-Amplifiers with Mu2e Electronics Installation Team

The author spent nine weeks over summer 2025 working on the tracker electronics installation team for the Mu2e experiment. One of her main responsibilities was repairing high voltage (HV) and calibration (Cal) pre-amplifiers (pre-amps). During installation, the fragile wires connecting the two sockets to the pre-amp board must be bent, often leading to breakage. During production, the sockets and wires were initially soldered to the board at UC Berkely, then the whole pre-amp was coated in parylene before transport to Fermilab. The interns were able to expedite the repairs, and thus whole installation process, by using an alternative method on-site with epoxy. Another task they were responsible for, not included in the original project specifications, was attaching copper clips to specific vias on the Cals to reduce noise. The talk will give listeners insight into the daily problem-solving required by the novel technologies in the Mu2e project. The author would like to acknowledge her fellow Monmouth College undergraduate interns, Lizzie Durfee and Gianna Maughan, advisor and PI of the DOE RENEW Grant Dr. Christopher G. Fasano, and the Mu2e team lead by co-spokesperson Dr. Bob Bernstein and tracker L2 manager Dr. Brendan Kiburg.

de Zwart, Bronte [Monmouth Coll.]↗

Fast Muon Capture Monitoring in Mu2e with the CAPHRI Detector

The Mu2e experiment at Fermilab will search for the charged lepton flavor violating (CLFV) process of a neutrinoless muon-to-electron conversion in the field of an aluminum nucleus. Reaching the experiment’s target sensitivity requires precise normalization of the physics signal through accurate monitoring of the muon capture rate on the stopping target. For this purpose, the Calorimeter Precise High-Resolution Intensity detector (CAPHRI) has been developed. The detector is composed of four LYSO crystals installed in the upstream disk of the Mu2e calorimeter and read out with the standard calorimeter readout. CAPHRI measures the muon capture rate by detecting the characteristic 1.8~MeV gamma emission line of the $^{27}Al(\mu^−, \nu n \gamma) ^{26}Mg$ nuclear reaction. The fast, precise response enables injection-by-injection monitoring of proton beam intensity fluctuations. We report on the commissioning and performance characterization of CAPHRI. The response of each channel is calibrated at two SiPM overvoltages using both the intrinsic self-emission of the LYSO crystals and cosmic ray signals. In parallel, Monte Carlo simulations are used to evaluate the detector acceptance and the expected signal-to-background ratio under realistic running conditions. Preliminary results show a crystal light yield consistent with expectations and a channel inter-calibration at the 2--4% level. Simulation studies indicate that the detector acceptance and background rejection satisfy the requirements for physics operations, with about 1000 detected events per beam injection at a beam power of 1.5~kW. These results demonstrate that CAPHRI is an effective tool for beam monitoring and signal normalization in Mu2e.

Ciccarella, V. [Frascati; U. Rome La Sapienza (mai↗