Search NASA⌕ Search

SEARCH · Search NASA

Results for “Multi-zone”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Guideline 36 Savings Calculator v0.1

This software package contains a simple calculator that can be used to estimate savings from implementing a retrofit of HVAC controls to ASHRAE Guideline 36 in a multi-zone office building. Implemented in Excel, the calculator has a user-interface front-end to configure parameters of the case study, such as location, building size, and existing control strategies, and a back-end containing results from a large number of pre-run annual energy simulations. The software package also contains the simulation models and associated pre- and post-processing scripts to generate these results.

Blum, David↗

LBC (Learning Building Control)

LBC encompasses the source code and data to reproduce and extend results for a manuscript that compares demand responsive control schemes for multi-zone buildings. It includes examples of model predictive control (MPC), value function approximation via CVXPYLAYERS, and differentiable predictive control (DPC). The goal of the study is to evaluate state-of-the-art controllers and establish the efficacy (if any) of learning-based approaches that leverage deep neural networks in one way or another.

Zhang, Xiangyu↗

Numerical investigation of a fueled pre-chamber spark-ignition natural gas engine

Pre-chamber spark-ignition (PCSI) is a leading advanced ignition concept for internal combustion engines with the potential to enable diesel-like efficiency in medium-duty/heavy-duty (MD/HD) natural gas (NG) engines. By leveraging distributed ignition sources from multiple turbulent jets, the PCSI technology can deliver extremely short combustion duration in ultra-lean mixtures and significantly improve the engine thermal efficiency. However, in the automotive industry there is a lack of adequate science base and predictive simulation tools required for commercial development of PCSI engines. Here, in this study, Reynolds-Average Navier-Stokes simulations are carried out to describe the combustion process in lean-burn NG engines, focusing on the combustion modeling approach. Two combustion models, multi-zone well-stirred reactor (MZ-WSR) and G-equation, are used to simulate the combustion process in an MD NG engine equipped with a fueled-PCSI system for four operating conditions close to the lean operating limit. A skeletal chemical mechanism and a laminar flame speed tabulation are used to compute the combustion accurately. Simulation results are compared with experimental data regarding measured cylinder pressure, heat release rate, and combustion duration. By dividing the PCSI combustion process into four distinct phases, the difference between the two models’ results for each phase is analyzed in detail. The MZ-WSR model overestimates the combustion duration for early flame kernel growth in the pre-chamber due to the lack of a specific formulation to take turbulence-chemistry interaction into account. Despite the prolonged combustion duration and low pressure built-up inside the pre-chamber, the model matches the combustion rate in the main-chamber. In contrast, the G-equation model delivers good agreements for the pre-chamber combustion and turbulent jet-driven combustion processes. However, the model starts to underestimate the combustion rate in the main-chamber, especially under ultra-lean mixture conditions. Finally, improvements are needed for both models to simulate the later combustion stage that occurred in the near-wall regions.

33 ADVANCED PROPULSION SYSTEMS↗

Process Development of a Direct Cast U-6Nb 250 mm Cylinder

Direct Casting is the process of casting a near-net shape part of U-6wt%Nb in a multi-zone VIM furnace for subsequent heat treatment and machining in to a final component. This interim report describes ongoing work to further develop a sound technical basis and best practices for mold design and process parameters for the Direct Casting of U-6Nb components with a cylindrical geometry. Specifically, process parameters and mold design are examined in detail for producing a hollow cylinder 250 mm diameter by 450 mm long which is 10 to 12 mm thick. The goal is to efficiently produce a sound casting with a minimum of microporosity and uniform niobium composition.

36 MATERIALS SCIENCE↗

Smart Building Start (SBS) (CRADA 480)

The idea of Smart Building Start (SBS) is to manage the on/off scheduling of HVAC equipment in buildings in an optimal way in order to achieve comfort conditions at the designated times with the minimal use of energy. This concept is also known as Optimal Start and it has typically been used in buildings to start up equipment based on predictions made for a representative (or average) zone in a building. This means that zones that could have waited longer to receive conditioned air are activated too early leading to unnecessary energy loss. The approach proposed in this project is to develop and implement a distributed version of optimal start that will consider the individual requirements of all treated zones. The developed control strategy will enable smart start of the central plant as well as further localized control over each individual zone by means of setpoint adjustment so that zones are not conditioned too early thereby reducing energy use compared to the current state of the art. This project is a collaboration between PNNL and Verdicity with the goal being to bring the research concept of SBS to commercialization. The SBS algorithm(s) will be implemented and hosted on the PNNL-developed open-platform VOLTTRON which will accelerate bringing the research to practice. It is anticipated that this project will lead to new IP surrounding the algorithm and its decentralized deployment. The project will also further demonstrate the success of VOLTRON as a flexible platform for implementation of innovative algorithms for improving energy efficiency in buildings. Previous studies on smart building start carried out by PNNL have indicated potential energy savings on the order of 10-15% for multi-zone buildings compared to conventional strategies. Verdicity currently has a number of customers who can benefit from the use of this technology. PNNL will work with Verdicity to identify any key gaps in the integrated software and jointly work to enhance and customize it for Verdicity and to integrate it with their existing products for use at their customers’ sites. The proposed work will help previously funded Federal research and development technology investments find their way into a viable commercial market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NuSTAR broad-band X-ray observation campaign of energetic pulsar wind nebulae in synergy with VERITAS, HAWC and Fermi gamma-ray telescopes

We report recent progress on the on-going NuSTAR observation campaign of 8 TeV-detected middle-aged pulsar wind nebulae (PWNe). This campaign constitutes a major part of our NuSTAR study of some of the most energetic TeV sources in our Galaxy detected by VERITAS and HAWC. NuSTAR is the first focusing X-ray telescope operating above 10 keV in space with sub-arcminute angular resolution. Broad-band X-ray imaging and spectroscopy data, obtained by NuSTAR, allow us to probe sub-PeV electron populations through detecting synchrotron X-ray radiation. Our targets include PeVatron candidates detected by HAWC, the Boomerang nebula, PWNe crushed by supernova remnant shocks (or relic PWNe) and G0.9‚0.1 in the Galactic Center. Combined with Fermi-LAT data and available TeV data, we aim to provide a complete, multi-wavelength view of a diverse class of middle-aged (~10–100 kyrs old) PWNe. Our NuSTAR analysis detected hard X-ray emission from the Eel and Boomerang PWNe and characterized their broad-band X-ray spectra most accurately. We plan to apply both time-evolution and multi-zone PWNe models to multi-wavelength spectral energy distribution (SED) data over the radio, X-ray, GeV and TeV bands. In this proceeding, we will review our observation campaign and discuss the preliminary results for some PWNe.

79 ASTRONOMY AND ASTROPHYSICS↗

Incipient Sensor Fault Impacts on Building Performance Through HVAC Controls: A Pilot Study

Sensors are crucial input components for HVAC controls. Studies show faults are common for buidings and HVAC systems. Sensors with faults will compromise the control perfrormance regardless how advanced of the control algorithms. Majority studies assume the sensor fault to be constant the whole year. In reality, the sensor faults might evolve or develop with time, which is essentially the incipient (i.e. evolving) fault. The incipient sensor faults impacts remain a research gap. This study aims to investigate the incipient sensor fault impacts to control sequences of multi-zone VAV boxes and AHU system following the ASHRAE Guideline 36-2018: High-Performance Sequences of Operation.

Li, Yanfei↗

Spallation-altered Accreted Compositions for X-Ray Bursts: Impact on Ignition Conditions and Burst Ashes

Model predictions of X-ray burst ashes and light curves depend on the composition of the material accreted from the companion star, in particular the abundance of CNO elements. It has previously been pointed out that spallation in the atmosphere of the accreting neutron star can destroy heavy elements efficiently. In this work we study this spallation using a realistic reaction network that follows the complete spallation cascade and takes into account not only destruction, but also production of elements by the spallation of heavier species. We find an increased survival probability of heavier elements compared to previous studies, resulting in significantly higher CNO abundances.We provide resulting compositions as a function of accretion rate, and explore their impact on 1D multi-zone X-ray burst models. Finally, we find significant changes in the composition of the burst ashes, which will affect the thermal and compositional structure of accreted neutron star crusts.

79 ASTRONOMY AND ASTROPHYSICS↗

First-principles-integrated Study of Blazar Synchrotron Radiation and Polarization Signatures from Magnetic Turbulence

Blazar emission is dominated by nonthermal radiation processes that are highly variable across the entire electromagnetic spectrum. Turbulence, which can be a major source of nonthermal particle acceleration, can widely exist in the blazar emission region. The Turbulent Extreme Multi-Zone (TEMZ) model has been used to describe turbulent radiation signatures. Recent particle-in-cell (PIC) simulations have also revealed the stochastic nature of the turbulent emission region and particle acceleration therein. However, radiation signatures have not been systematically studied via first-principles-integrated simulations. In this paper, we perform combined PIC and polarized radiative transfer simulations to study synchrotron emission from magnetic turbulence in the blazar emission region. We find that the multiwavelength flux and polarization are generally characterized by stochastic patterns. Specifically, the variability timescale and average polarization degree (PD) are governed by the correlation length of the turbulence. Interestingly, magnetic turbulence can result in polarization angle swings with arbitrary amplitudes and duration, in either direction, that are not associated with changes in flux or PD. Surprisingly, these swings, which are stochastic in nature, can appear either bumpy or smooth, although large-amplitude swings (>180°) are very rare, as expected. Our radiation and polarization signatures from first-principles-integrated simulations are consistent with the TEMZ model, except that in the latter, there is a weak correlation, with zero lag, between flux and degree of polarization.

79 ASTRONOMY AND ASTROPHYSICS↗

Unraveling the Complex Behavior of Mrk 421 with Simultaneous X-Ray and VHE Observations during an Extreme Flaring Activity in 2013 April

Here we report on a multiband variability and correlation study of the TeV blazar Mrk 421 during an exceptional flaring activity observed from 2013 April 11 to 19. The study uses, among others, data from GLAST-AGILE Support Program (GASP) of the Whole Earth Blazar Telescope (WEBT), Swift, Nuclear Spectroscopic Telescope Array (NuSTAR), Fermi Large Area Telescope, Very Energetic Radiation Imaging Telescope Array System (VERITAS), and Major Atmospheric Gamma Imaging Cherenkov (MAGIC). The large blazar activity and the 43 hr of simultaneous NuSTAR and MAGIC/VERITAS observations permitted variability studies on 15 minute time bins over three X-ray bands (3–7 keV, 7–30 keV, and 30–80 keV) and three very-high-energy (VHE; >0.1 TeV) gamma-ray bands (0.2–0.4 TeV, 0.4–0.8 TeV, and >0.8 TeV). We detected substantial flux variations on multi-hour and sub-hour timescales in all of the X-ray and VHE gamma-ray bands. The characteristics of the sub-hour flux variations are essentially energy independent, while the multi-hour flux variations can have a strong dependence on the energy of the X-rays and the VHE gamma-rays. The three VHE bands and the three X-ray bands are positively correlated with no time lag, but the strength and characteristics of the correlation change substantially over time and across energy bands. Our findings favor multi-zone scenarios for explaining the achromatic/chromatic variability of the fast/slow components of the light curves, as well as the changes in the flux–flux correlation on day-long timescales. We interpret these results within a magnetic reconnection scenario, where the multi-hour flux variations are dominated by the combined emission from various plasmoids of different sizes and velocities, while the sub-hour flux variations are dominated by the emission from a single small plasmoid moving across the magnetic reconnection layer.

79 ASTRONOMY AND ASTROPHYSICS↗

Bridging Scales in Black Hole Accretion and Feedback: Magnetized Bondi Accretion in 3D GRMHD

Fueling and feedback couple supermassive black holes (SMBHs) to their host galaxies across many orders of magnitude in spatial and temporal scales, making this problem notoriously challenging to simulate. We use a multi-zone computational method based on the general relativistic magnetohydrodynamic (GRMHD) code KHARMA that allows us to span 7 orders of magnitude in spatial scale, to simulate accretion onto a non-spinning SMBH from an external medium with a Bondi radius of R B ≈ 2 × 10 5 GM•/c 2 , where M• is the SMBH mass. For the classic idealized Bondi problem, spherical gas accretion without magnetic fields, our simulation results agree very well with the general relativistic analytic solution. Meanwhile, when the accreting gas is magnetized, the SMBH magnetosphere becomes saturated with a strong magnetic field. The density profile varies as ~r -1 rather than r -3/2 and the accretion rate $\dot{M}$ is consequently suppressed by over 2 orders of magnitude below the Bondi rate $\dot{M}$ B . Here, we find continuous energy feedback from the accretion flow to the external medium at a level of $\thicksim$ 10 -2 $\dot{M}$c 2 $\thicksim$ 5 X 10 -5 $\dot{M}$ B c 2 . Energy transport across these widely disparate scales occurs via turbulent convection triggered by magnetic field reconnection near the SMBH. Thus, strong magnetic fields that accumulate on horizon scales transform the flow dynamics far from the SMBH and naturally explain observed extremely low accretion rates compared to the Bondi rate, as well as at least part of the energy feedback.

79 ASTRONOMY AND ASTROPHYSICS↗

Three-Dimensional CFD Investigation of Pre-Spark Heat Release in a Boosted SI Engine

Low-temperature heat release (LTHR) in spark-ignited internal combustion engines is a critical step toward the occurrence of auto-ignition, which can lead to an undesirable phenomenon known as engine knock. As such, correct predictions of LTHR are of utmost importance to improve the understanding of knock and enable techniques aimed at controlling it. While LTHR is typically obscured by the deflagration following the spark ignition, extremely late ignition timings can lead to LTHR occurrence prior to the spark, i.e., pre-spark heat release (PSHR). In this research, PSHR in a boosted direct-injection SI engine was numerically investigated using three-dimensional computational fluid dynamics (CFD). A hybrid approach was used, based on the G-equation model for representing the turbulent flame front and the multi-zone well-stirred reactor model for tracking the chemical reactions within the unburnt region. A recently developed best practice was also employed which keeps the well-stirred reactor model active throughout the entire simulation. This allowed for correct predictions of the previous cycle trapped residuals which have a considerable effect on the onset of LTHR. Multi-cycle simulations were conducted using Co-Optima alkylate and E30 fuels. The predicted in-cylinder pressure and heat release rate agreed well with the experimental data and served as validation for the CFD model. Following the initial validation, the dynamics of PSHR was discussed and a series of parameters of interest were assessed. First, the effect of exhaust valve temperature was investigated, qualitatively highlighting the importance of boundary conditions uncertainty. Further analyses were carried out on the effects of fuel properties, including laminar flame speed (LFS) and heat of vaporization (HOV). The results indicate that PSHR phasing is slightly advanced with lower LFS as more trapped unburnt fuel is made available for the next cycle. A similar trend was observed with lower HOV as less intense spray cooling led to higher mixture temperatures, i.e., higher mixture reactivity. Finally, a comparison of Co-Optima alkylate and E30 fuels was made using the pressure-temperature trajectory framework. It was shown that the differences between Co-Optima alkylate and E30 in PSHR tendency are correlated with both HOV and chemical effects.

33 ADVANCED PROPULSION SYSTEMS↗

Evaluation of Combustion Models for CFD Simulation of Pre-Chamber Ignition in a Natural Gas Engine

Natural gas is considered an attractive alternative fossil fuel as it produces 25% less carbon dioxide and emits fewer amounts of toxic pollutants compared to gasoline and diesel. A pre-chamber type ignition device in a natural gas engine is capable of extending the lean operating limit, and hence improving thermal efficiency, by providing spatially distributed ignition with multiple turbulent flame-jets and accelerating the combustion rate. However, the process of ignition in the main chamber triggered by turbulent jets emanating from a pre-chamber is very sensitive to the pre-chamber geometry and fueling strategy, and any effort to optimize these parameters requires fundamental understanding of the underlying physical and thermodynamic phenomena, which can be studied by a multi-dimensional numerical simulation approach. In this study, three turbulent combustion models widely adopted in the multi-dimensional engine modeling community were preliminary evaluated to simulate the combustion process in a natural gas engine with a pre-chamber spark-ignition system. One multi-zone well-stirred reactor model, and two flamelet-based combustion models, G-equation and Extended Coherent Flamelet Model, were employed for this assessment. Under a fuel-lean condition, the three combustion models were used to match experimental data and analyze the differences in terms of in-cylinder pressure and heat release rate.

combustion model evaluation↗

Occupancy-Driven Stochastic Decision Framework for Ranking Commercial Building Loads

For effective integration of building operations into the evolving demand response programs of the power grid, real-time decisions concerning the use of building appliances for grid services must excel on multiple criteria, ranging from the added value to occupants' comfort to the quality of the grid services. In this paper, we present a data-driven stochastic decision-support framework to dynamically rank load control alternatives in a commercial building, addressing the needs of multiple decision criteria (e.g. occupant comfort, grid service quality) under uncertainties in occupancy patterns. We adopt a stochastic multi-criteria decision algorithm recently applied to prioritize residential on/off loads, and extend it to i) consider complex load control decisions (e.g. dimming of lights, changing zone temperature set-points) in a commercial building; and ii) systematically integrate zonal occupancy patterns to better identify short-term (and time-varying) opportunities for grid service participation. We evaluate the performance of the proposed framework for curtailment of air-conditioning, lighting, and plug-loads in a multi-zone commercial office building for a range of design choices. With the help of a prototype system that integrates an interactive \textit{Data Analytics and Visualization} frontend we demonstrate a way for the building operators to monitor and change in real-time the available flexibility in energy consumption and to develop trust in the decision recommendations by interpreting the rationale behind the ranking.

Jain, Milan↗

An Energy Calculator for Simple Commercial Buildings

According to the EIA, simple commercial buildings account for 97% of total commercial building stock. However, most simple commercial buildings for example small- to mid-sized offices, retail, schools and warehouses do not benefit from the data-driven decision-making capabilities of whole-building energy modeling. The high cost of custom modeling limits the use of energy modeling of simple buildings for new construction or retrofit measures. Lack of tools providing helpful information on interactive savings estimates creates difficulties in meeting aggressive decarbonization and energy efficiency goals for simple building designers and utility program managers. This paper reviews a beta phase Simple Building Calculator with the ability to generate relatively accurate and interactive modeling results based on a limited but robust set of inputs. It can evaluate whole-building or single measure savings in new or existing buildings, compare measure package choices, or provide simplified performance modeling for energy codes and utility incentives. The tool combines physical (annual whole building prototype simulation) and statistical modeling techniques to predict annual energy performance. It supports a variety of building characteristics for envelope, HVAC, and lighting with parameters ranging from vintage to max tech configurations, as well as support for single-zone and simple multi-zone HVAC systems. The Simple Building Calculator was designed to provide immediate feedback for otherwise computationally intensive tasks like measure comparison, development of multiple measure package combinations, or verification that measures meet efficiency targets—all with the goal of providing a tool for quick annual energy simulation of simple commercial buildings.

Hart, Reid↗

A Survey of Multizone Airflow Simulation Software

H-Canyon simulates the building and process ventilation to ensure positive contamination control for any modifications as well as evaluating off-normal conditions. Simulations can also be used to identify air quality of personnel occupied areas. The models can be classified into two groups, single and multi-zone models. As the name states, a single zone model assumes that the building can be described by a single, well-mixed zone. Whereas large buildings have structures that must be described as multizone. Multizone airflow models deal with the difficulty of flows in a building by distinguishing the effects of internal flow restrictions. Several models have been developed that take internal partitions into account. CONTAM (currently used) is a multizone airflow program created by NIST to determine airflows including infiltration, exfiltration, wind pressures acting outside the building, buoyancy effects caused by the indoor and outdoor air temperature difference. COMIS is a multizone air infiltration, ventilation, and contaminant transport model that was developed at Lawrence Berkeley National Laboratory. COMIS deals with applied pressure distribution, airflow components, HVAC systems, schedules, and contaminant transport. EnergyPlus is designed by DOE. It supports flexible component level configuration of HVAC models and simulates sub-hourly time steps to control fast dynamic systems. The program features include providing accurate environmental performance data including energy consumption and carbon emissions, and reporting solar gains on surfaces. Heavent is used to model industrial ventilation systems to control airborne contaminants. It's designed based on the American Conference of Governmental Industrial Hygienists (ACGIH) Ventilation manual. DesignBuilder is the most recognized and advanced user interface to EnergyPlus. It gives access to all of the most frequently required simulation capabilities covering building fabric, thermal mass, glazing, shading renewables, and HVAC analysis. The objective of this study is to identify all relevant software available including commercially licensed, freely licensed, and open source, that can be used to simulate large, complex process facility ventilation systems. All discovered software tools are evaluated for salient features and compared to the software tool currently used to simulate the H-Canyon ventilation system. The design criteria of a ventilation system has two basic requirements: Supplying fresh air for the occupants and changing the air in the room sufficiently; therefore, the smells, fumes, and contaminants will be removed. In this study, first, whether the software simulates airflow (infiltration, natural ventilation, and interzonal) or considers them to be inputs is discussed. Second, if indoor contaminant levels are considered; and finally suggestions on how airflow analysis can be more appropriately accounted for when performing airflow simulation of a building. All of the airflow software reviewed for this study can account for constant infiltration and natural ventilation rates that are not affected by changes in indoor and outdoor conditions. Modelling infiltration in EnergyPlus or DesignBuilder are applicable for small buildings and not appropriate for larger buildings like the H-Canyon. The effect of wind on external pressures, infiltration, and natural and mechanical ventilation, can also be calculated using all of these software. These programs have control options to switch between natural to mechanical ventilation modes or both (hybrid). Interzonal airflow can be applied which means one zone can be specified to receive a fixed amount of air from another zone. The following ventilation modeling software is recommended for further testing: CONTAM, COMIS, Heavent. The next step in evaluating the software will consist of creating test facility simulations using evaluation copies of the software.

42 ENGINEERING↗

Evaluating Chemical Kinetics Predictions for Propane Using 3-D and 0-D Models in a Boosted Spark-Ignited Engine

Propane has been shown to be a promising alternative fuel to reduce emissions while simultaneously achieving high efficiencies in medium- and heavy-duty engines. These high-power density applications require boosted engines which, combined with high compression ratio, can lead to auto-ignition and knock. While three-dimensional (3-D) computational fluid dynamics (CFD) models are often used for resolving the complex fluid flow in engines, these models can become computationally expensive when simulating detailed chemical kinetics. Likewise, zero-dimensional (0-D) models are computationally concise enough for kinetics development, but lack any flow-field information which governs the flame propagation processes in spark ignition (SI) engines. This work presents a comprehensive comparison between 3-D and 0-D closed cycle simulations at knocking conditions in a high compression ratio high stroke-to-bore ratio propane engine. In order to initialize the flow-field for the 3-D closed cycle (intake valve closing, (IVC) to exhaust valve opening, (EVO)) simulation, a motored multi-cycle 3-D model was run using Converge to create a map at IVC, reducing the computational time. The map allowed a non-homogeneous 3-D closed cycle simulation to be satisfactorily validated against experiments, while a homogeneous case using only the turbulence field mapping was also simulated, mimicking 0-D modeling. The 3-D simulations were used to prescribe the initial conditions (e.g., IVC thermodynamics, speciation, burn-rate profile) for a 2-zone 0-D SI engine model in Chemkin Pro for both cases. It was found that 2-zone 0-D modeling underpredicted the knock onset timing, likely due to the lack of thermal stratification in the unburned gas region. Future work will carry multi-zone 0-D modeling to capture the fuel auto-ignition in the unburned region.

Douvry-Rabjeau, Julien [Oakland University, Roches↗