Characterization of NORM in an Urban Environment using HPGe Measurements and MCNP6 Simulations

This work is part of a larger project aimed at producing an operationally relevant, validated simulation environment that can be used as a 'virtual testbed' for counterterrorism and counterproliferation efforts. Examples of such efforts include searches for illicit radiation sources before and during large special events, such as the presidential nominating conventions, inaugurations, and large sporting events. Once validated by laboratory and field measurements, this testbed can be used to test and validate algorithms and detector systems designed for various search missions in an urban environment. The detection of radioactive sources in a city is greatly complicated by natural background radiation, which emanates from various materials common to an urban environment, such as roadways, sidewalks, and building exteriors. The methods and results offered here represent the conclusion of an effort to characterize the concentration of naturally occurring radioactive material (NORM) in various elements in a controlled, but representative, urban environment. Some of the methods discussed in previous work will be briefly reiterated here, but more detail can be found in the preceding work. The location chosen for this effort was a Military Operations on Urban Terrain (MOUT) environment at the Fort Indiantown Gap (FTIG) National Guard training facility in Pennsylvania. This site was chosen because it replicates a small town where traffic and pedestrian access could be easily controlled, as to not interfere with the background measurements. This endeavor involved over 70 measurements using a high-purity germanium (HPGe) detector designed to ascertain the NORM concentrations in the soil, asphalt roads, gravel lots, concrete intersections, sidewalks, foundations, and walls found throughout the site. The NORM concentrations determined from this work will be incorporated into a large-scale simulation that can be used to investigate various search techniques and algorithms, detector types and setups, and to produce representative synthetic data for future work.

07 ISOTOPE AND RADIATION SOURCES↗

Development of a Course in Gamma Ray Spectrometry

The majority of undergraduate and graduate students in nuclear science and engineering take a general course in nuclear instrumentation where one of the topics is typically in gamma ray spectrometry. Rarely are courses offered solely on this subject matter other than intensified workshops conducted by the International Atomic Energy Agency (IAEA) or private companies which can be expensive especially for large groups of students. Currently there are many world-wide projects in routine monitoring and advanced research that employ gamma rays. Some but not an exhaustive list of these topics include neutron activation analysis, naturally occurring radioactivity materials (NORM), nuclear forensics, nuclear security, in-situ gamma ray detection, galactic gamma ray detection, health physics and advanced instrumentation. At the Nuclear Engineering Teaching Laboratory at the University of Texas at Austin, many of our students are involved in an array of research topics that involve gamma ray spectrometry in their Masters of Science theses, PhD dissertations and special topics courses. It was decided to invest the time and effort to develop a course with a strong technical component to complement their research activities. A detailed stand-alone course in gamma ray spectrometry that includes a series lectures in modular form has been developed. As well we have incorporated fourteen advanced animations to better explain some of the fundamental physical processes and experimental set-ups. Six laboratory sessions and multiple homework assignments have also been established. This course is applicable to senior undergraduate students, graduate students, and novice researchers the above mentioned fields in a traditional class/laboratory setting or for intense one to two week workshops. A great deal of effort was undertaken to prepare a stand-alone course in gamma ray spectrometry which includes many of the fundamental aspects as well as the more advanced instrumentation. Animations of gamma ray interactions and experimental set ups were also developed. Six laboratories and six assignments were also conceived. Every topic has its own module thus a 'pick and choose' subset of lectures can be given to different levels of understanding. This course is applicable to senior undergraduate students, graduate students, novice researchers in neutron activation analysis and naturally occurring radioactive material, and for intense one to two week workshops. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, 39Ar, a ß emitter of cosmogenic origin. For large detectors, the atmospheric 39Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of 39Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of 39Ar with respect to AAr by a factor larger than 1400. Assessing the 39Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly ?-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.

Noble liquid detectors, Dark Matter detectors, Cry↗

Immobilization of Radioactive Materials Using Porous Iron Composite Media - 18582

High levels of nitrate (NO{sub 3}) derived from agriculture and naturally occurring radioactive materials (NORM), primarily uranium (U) and natural decay chain products that have been mobilized by the influx of oxygenated, high-alkalinity water, are a threat to shallow groundwater resources in California. Porous Iron Composite (PIC) materials were evaluated as a water treatment option in a series of batch experiments. While the use of Zero Valent Iron (ZVI) to address groundwater contaminated with NO{sub 3} or U has been demonstrated, the ability of PICs to chemically reduce and immobilize U and other associated contaminants in oxygenated alkaline groundwater where soluble uranyl-carbonate species dominate and high NO{sub 3} levels may compete for reductive capacity remain a concern. Additionally, ZVI materials have been used to immobilize other redox sensitive radionuclides (e.g., technetium-99 ({sup 99}Tc)) with limited success. Batch tests were conducted using an artificial groundwater surrogate (i.e., CAGW for California Groundwater) containing ∼ 100 mg L{sup -1} NO{sub 3}{sup -}, 200 mg L{sup -1} alkalinity, 100 μg L{sup -1} U, 100 μg L{sup -1} rhenium (Re) as a non-radioactive surrogate for the nuclear fission product technetium-99 ({sup 99}Tc), 100 μg L{sup -1} stable strontium (Sr) as a surrogate for radium (Ra) and the fission product strontium-90 ({sup 90}Sr), and 50 μg L{sup -1} arsenic (As), a common groundwater contaminant. Five gram samples of the PIC material were reacted with 200 mL of CAGW under two different atmospheric conditions to evaluate the impact of O{sub 2}. Batch tests were also conducted in the presence and absence of another oxidized species, NO{sub 3}. At specific time intervals, a small aliquot was collected from each batch treatment for chemical analysis (i.e., U, Re, As, Fe, NO{sub 3}, etc.) and the pH and ORP of the remaining suspension was measured. The PIC was effective at fully reducing NO{sub 3}{sup -} levels over the extended reaction time, even though the reactor pH quickly increased above 8.0 during equilibration. Soluble levels of U and Re decreased in a similar fashion to NO{sub 3}{sup -} in the presence and absence of O{sub 2}. Soluble As levels decreased more rapidly than other contaminants, but remained at ∼ 1 μg L{sup -1}. Very little nitrite (NO{sub 2}{sup -}) was detected in the batch tests, with NH{sub 4}{sup +} levels consistent with the amount of NO{sub 3}{sup -} reduced. Similar rates of immobilization for U, Re, and As were observed in the presence and absence of NO{sub 3}{sup -}. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New Low-Background Laboratory in the Pyhäsalmi Mine, Finland

A new low-background laboratory has been constructed in the Pyhäsalmi mine in central Finland and was commissioned in the beginning of 2017. The underground experimental hall is located at a depth of 1436 m corresponding to about 4100 m of water equivalent (m.w.e.). We describe the equipment of the laboratory and the backgrounds arising from the natural rock radioactivity and the flux of cosmic ray muons at the experimental hall location. The high-sensitivity experiments operating at the low-background laboratory are briefly described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of MARSSIM and MARSAME Guidance to Footprint Reduction Projects at a DOE Site (LA-UR-15-28730) - 16216

Department of Energy regulations require that potentially contaminated items and materials being released to the public are monitored and that any residual radioactive contamination does not contribute more than 10 μSv/y (1 mrem/y). In footprint reduction and demolition projects, buildings with potential residual contamination must be carefully and systematically surveyed prior to recycling materials or releasing debris for burial in commercial landfills. Multi-agency guidance is available to assure statistically representative sampling of the items and materials, appropriate measurement quality objectives, and valid statistical approaches for release decisions. Additionally, implementing a cost-effective evaluation program for releases requires working closely with regulators and waste generators and developing a technically sound process to account for naturally occurring radioactive material (NORM) in building materials. Los Alamos National Laboratory has successfully implemented the available guidance for footprint reduction projects to help divert clean, recyclable materials from landfills and limit the possibility of mistakenly disposing of NORM as low level waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A record of uranium-series transport at Nopal I, Sierra Pena Blanca, Mexico: Implications for natural uranium deposits and radioactive waste repositories

Studies of uranium-series (U-series) disequilibria within and around ore deposits provide valuable information on the extent and timing of actinide mobility, via mineral-fluid interaction, over a range of spatial and temporal scales. Such information is useful in studies of analogs of high-level nuclear-waste repositories, as well as for mining and mineral extraction sites, locations of previous nuclear weapons testing, and legacy nuclear waste contamination. In this study we present isotope dilution mass spectrometry U-series measurements for fracture-fill materials (hematite, goethite, kaolinite, calcite, dolomite and quartz) from one such analog; the Nopal I uranium ore deposit situated at Peña Blanca in the Chihuahua region of northern Mexico. The ore deposit is located in fractured, unsaturated volcanic tuff and fracture-fill materials from surface fractures as well as fractures in a vertical drill core have been analyzed. High uranium concentrations in the fracture-fill materials (between 12 and 7700 ppm) indicate uranium mobility and transport from the deposit. Furthermore, uranium concentrations generally decrease with horizontal distance away from the deposit but in this deposit there is no trend with depth below the surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Microwave Technology for TENORM Waste Treatment - 17377

The sludge and scales generated by the oil and gas industry usually contain radionuclides of the thorium and uranium decay chains, the so-called technologically enhanced, naturally occurring radioactive materials (TENORM) waste. The handling of this waste must consider both the radiation risks presented by those radionuclides and its chemical toxicity, due to the decomposition of oil residues, which may generate hydrogen sulfide and other hazardous compounds. In the case of Brazil, Public Law 10.308 limits the management options for radioactive waste generated by offshore oil production rigs to drumming and storage; it prohibits disposal of any radioactive waste in sea-waters, seabed or oceanic islands. This paper describes the results of the work to develop a treatment process using a specially designed microwave oven, which removes simultaneously water and hydrocarbons from the sludge, thus reducing the volume, the chemical toxicity and the chemical reactivity of the waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Assessment of a New Gamma Spectroscopy Toolkit: Peak Doctor and the Spectral Nondestructive Assay Platform (SNAP) - 17397

High resolution gamma spectroscopy (HRGS) is a widely used technique for non-destructive characterization of nuclear materials, and assay of radioactive waste. The ability to accurately evaluate raw spectral data is an important step in producing high-quality results. A spectral analysis application known as Peak Doctor has been developed under a Cooperative Research and Development Agreement (CRADA) between LANL and Pajarito Scientific Corporation (PSC). The software has undergone several years of testing and validation by the Radioactive Waste Characterization Team of the LANL Waste Management Services Group (WM-SVS). PeakDoctor is designed to work with the Spectral Nondestructive Assay Platform (SNAP{sup TM}) to provide a complete HRGS analysis engine. SNAP{sup TM} performs model specific corrections for attenuation and geometry. These applications are the major components of a new toolkit designed primarily for portable far-field non-destructive assay. Peak Doctor performs a very accurate peak fit analysis with the goal of improving upon the capabilities of existing commercially available routines. It is designed to be user-configurable and can be customized to any given type of detector and any given type of spectrum. Peak Doctor was developed to resolve many of the inherent complexities in gamma ray spectra including overlapping peaks, complex multiplet regions, large step peaks, backscatter regions and Compton edges. Unlike most spectral analysis platforms, Peak Doctor does not rely on the energy calibration and detector resolution parameters that are saved by the operator in the spectrum file. Instead, key parameters are pre-defined for individual detectors. The software fits a continuum using a series of splines between a series of junctions or 'knots'. Fitting techniques are used to join the splines together to create a near-continuous multi-element curve. Optimizing the location of the knots is one of Peak Doctor's most powerful features. The knots are initially configured using a pre-defined list and are removed or added automatically during the fitting process. Knots are also created when new features are identified such as Step Peaks and Compton Edges. The user can also manually specify knots in order to improve the continuum fit. The initial fit is improved on by removing any outlier regions (which are converted to peaks) and the continuum fitting process is repeated. At this stage, an experienced user can work interactively with the fit by manually converting peak regions to continuum or vice versa. The final step is to fit a series of peaks above the continuum based on detector parameters. Single and multiplet peaks are then processed by either the tailing (piecewise) or non-tailing (Gaussian) Levenberg Marquardt non-linear peak fitting routine depending on the user defined selection. Only a rough knowledge of the detector characteristics (energy calibration and resolution) is required for the fitting process to proceed with good accuracy. Any peaks that are missed can be manually added by the user and will also be fitted. Discontinuities in the peak / continuum fit can be rapidly identified by reviewing the 'residuals scale' plot. For waste streams that are well characterized, it is often the case that routinely encountered spectra will have similar peaks and continuum features. For these cases a handy 'One Step' method is available that proceeds in an automated fashion without user interaction. Peak Doctor has been configured with a set of default spectrum types including plutonium / transuranic waste (including Weapons Grade Pu, Heat Source Pu, Am-241, Am-243 and Np-237), depleted or enriched uranium, nuclear power plant / intermediate level waste (with fission and activation products such as Cs-137 and Co-60) as well as Naturally Occurring Radioactive Materials (NORM). The user can easily add new spectrum types for specific waste streams or other types of radiological / special nuclear materials. The output from PeakDoctor (including net peak area, centroid energy and a list of minimum detectable activity levels at pre-defined regions) is used by SNAP{sup TM} to complete the data analysis process. Isotope activities are calculated using configurable template-driven geometry and attenuation correction methods. The software accounts for matrix and container wall effects, collimator / angular corrections, detector efficiency (based on calibration curves) and stand-off distance. SNAP{sup TM} uses published algorithms incorporating a series of decision points during its operation to allow the analyst to provide logical input to guide the software during the analysis of each unique spectrum. The Peak Doctor / SNAP{sup TM} toolkit has been extensively tested and validated under a variety of conditions using 'benchmark' reference spectra. Test scenarios reported include HPGe-based measurements of well characterized uranium and plutonium standards and radioactive sources with a variety of different geometries and matrix materials including surrogate drums and boxes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recent Regulatory Challenges Associated with Managing NORM and TENORM Waste Streams in the United States - 19609

Recent regulatory changes in several states in the United States (U.S.) have introduced new challenges to industries impacted with naturally occurring radioactive materials (NORM) and/or technologically enhanced NORM (TENORM) requiring innovative solutions. Because NORM and TENORM are specifically exempt from U.S. Nuclear Regulatory Commission (NRC) regulations, the onus falls on the 50 states to regulate their use and disposal. Over the past 10 years, regulations applying to NORM and TENORM have been drafted, passed, or updated in multiple states, including North Dakota, Pennsylvania, Illinois, and West Virginia to name a few. Solutions and lessons learned before and during the recent regulatory changes for a variety of clients, including specialty metals, mining, and oil and gas (O and G), are presented. In addition, the design and implementation of the comprehensive study of NORM/TENORM associated with conventional and unconventional O and G production activities in Pennsylvania on behalf of the Pennsylvania Department of Environmental Protection (PADEP) is presented, and the development of analytical solutions and waste processes designed to minimize the impact of the new regulations while maintaining compliance is discussed. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Overview of IAEA MODARIA II Program Working Group 1 on Assessment and Decision Making of Existing Exposure Situations for NORM and Nuclear Legacy Sites - 18308

The International Atomic Energy Agency (IAEA) launched the Modelling and Data for Radiological Impact Assessments (MODARIA) II Programme in October. As part of the IAEA effort to enhance the capabilities of its Member States in assessing radiological impacts of radionuclides released to the environment from sites that were not operated in accordance with current standards, and to ensure protection of the public and the environment, the MODARIA II Programme aims to: (1) test the performance of models developed for predicting the transfer of radionuclides in the environment and assessing radiological impacts to the public and the environment; (2) develop and improve models for particular environments and, where appropriate, to agree on data sets that are generally applicable for use in testing environmental transfer models; and (3) provide an international forum for the exchange of experiences, ideas and research information. The Programme will run for 3 years from 2016 to 2019. The Programme comprises seven working groups covering a wide range of topics (https://wwwns.iaea.org/projects/modaria/modaria2.asp?s=8 and l=129). MODARIA II Working Group 1 (WG1) is focused on dose assessment and decision making regarding existing exposure situations due to naturally occurring radioactive material (NORM) and nuclear legacy sites. WG1 was formed as a combination of two MODARIA I WGs: WG1 focused on application of decision-aiding tools in remediation; and WG3 focused on risk assessment for NORM and radioactively contaminated legacy sites (https://wwwns.iaea.org/projects/modaria/default.asp?s=8 and l=129). It was recognized that the decision-making needs will inform the scope of risk assessments, and the risk insights and structured decision analyses will aid in informed decision-making. Therefore, MODARIA II WG1 is focused on developing methods and toolsets for risk-informed decision-making for NORM and nuclear legacy sites, including demonstration of decision-making processes and tools through case studies. MODARIA II WG1 has 91 registered participants from 33 Member States and IAEA (as of November 2017), some 30 of whom are actively engaged in various collaborative research and development activities within WG1. Members of WG1 participated in the First Technical Meeting of MODARIA II, which was held in Vienna, Austria from 31 October to 4 November 2016. The group then held its First Interim Meeting in Brussels, Belgium from 26 to 30 June 2017, which included a field trip to the legacy Tessenderlo Chemie (TCH) Phosphate Processing Site. At this meeting, the TCH Site and the Pridneprovsky Chemical Plant (PChP) in Ukraine were selected for case studies. The Los Alamos National Laboratory (LANL) Material Disposal Area B in the USA and the Beaverlodge Uranium Mill and Mill Site in northern Canada were selected as examples for sharing of good practices and lessons learned in risk-informed decision-making for environmental remediation and land conveyance. At the Second Technical Meeting held in Vienna on 30 October to 3 November 2017, an additional NORM site for tin processing in Brazil was added to the case studies, with another NORM site in Yunnan, China included for consideration at the Second Interim Meeting of WG1. The Second Interim Meeting will be held in in early to mid-May, 2018. The group has also decided to prepare an Interim Report by October 2018 to document the WG1 discussions and analyses for the period of 2016-2018, which will be finalized at the conclusion of MODARIA II in October 2019. Initial assignments have been discussed for IM1 participants to collect data, conduct modelling and analyses, and prepare draft sections for the Interim Report. This paper will provide an overview of the work plans for WG1. It will also highlight some near-term activities that the group is currently working on. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Status Update on IAEA MODARIA II Working Group 1 (Assessment and Decision Making) - 19391

During WM2018, the work being done under the International Atomic Energy Agency (IAEA)'s Modelling and Data for Radiological Impact Assessments (MODARIA) II Programme (https://wwwns.iaea.org/projects/modaria/modaria2.asp?s=8 and l=129) was introduced. The Programme comprises seven working groups covering a wide range of topics. Amongst them, Working Group 1 (WG1) is focused on dose assessment and decision aiding tools to address existing exposure situations due to past practices involving naturally occurring radioactive material (NORM) and nuclear legacy sites. Specifically, this covers the development of methods and toolsets for risk-informed decision-making for such complex sites, and includes practical demonstration of decision-making processes and tools through case studies. During 2018 WG1 participants met twice to discuss the status and plans of work being conducted by the WG. The group held its Second Interim Meeting from 7 to 11 May 2018 at the Jozef Stefan Institute (JSI) in Ljubljana, Slovenia. The objectives of the meeting were to: (1) Discuss the status of WG1 work; (2) Start preparation of the interim draft version of the MODARIA II WG1 Report (herein referred to as the 'Interim Report'); (3) Review the progress of planned data analyses, model-model comparisons, and model-data comparisons being conducted through case studies for the Tessenderlo Chemie Site in Belgium, the Zapadnoe Uranium Mill Tailings Site in Ukraine, and a Former Tin Processing Facility Site in Brazil; (4) Discuss calculations conducted for a NORM Site in China for potential addition to the WG1 case studies; (5) Report on progress on topical studies and other assignments performed to support the preparation of several sections of the Interim Report; and (6) Discuss plans for incorporating some preliminary case studies considered by MODARIA I WG1 and MODARIA I WG3. During the meeting in Slovenia, WG1 participants also visited the Zirovski vrh (RZV) Uranium Mine and Mill Tailings Site near Ljubljana. From 22 to 25 October 2018, WG1 members also participated in the MODARIA II Third Technical Meeting in Vienna, Austria. The meeting facilitated analysis of the progress made so far by the seven working groups, as well as exploration of the dissemination of the results of the MODARIA II Programme through publication in scientific journals dealing with the various subject areas covered by the Programme. WG1 participants focused on the preparation of its Interim Report, and engaged in technical exchanges with the IAEA Le Trench Project on characterization, assessment, remediation and management of buried waste at legacy trench sites, as well as the To Enhance uncertainties Reduction and stakeholders Involvement Towards integrated and graded Risk management of humans and wildlife In long-lasting radiological Exposure Situations (TERRITORIES) project (https://territories.eu/). Currently, WG1 is in the process of preparing a draft report to document the results of its various case studies and special topics, and is preparing for the final Interim Meeting in May 2019 and the final Technical Meeting in October 2019, before the conclusion of the MODARIA II Program at the end of 2019. This paper will provide a status update of these activities, along with preliminary information on the WG1 report, including potential recommendations for future activities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Rapid Sequential Separation Method for Determination of Actinides and TENORM in Fracking Wastes - 20223

With recent advances in unconventional drilling technology in the US and around the world, the risks of environmental contamination and exposure due to technologically enhanced naturally occurring radioactive materials (TENORM) from fracking wastes have also surfaced. Although the Permian Basin (southeastern New Mexico, western Texas) has long been a modest producer of oil, the advent of fracking technology a decade ago turned it into hot property for producers. A 2018 assessment of undiscovered, technically recoverable continuous oil and gas resources by the U.S. Geological Survey estimates an average 46.3 billion barrels of oil and 281 trillion cubic feet of gas. This is likely to increase the use of unconventional drilling and TENORM generation. TENORM concentrations in oil and gas exploration and production waste can be several hundred to several thousand times higher than background TENORM concentrations. Both the thorium and uranium decay chains contribute to airborne radionuclides arising from the radon gas escaping the ground and subsequently decaying as airborne particulates. Additionally, radon decay products {sup 210}Pb and {sup 210}Po can build up in scale on the internal surfaces of oil and gas handling pipes and in sludge in refineries, becoming potential inhalation and ingestion hazards for workers. Furthermore, southeastern NM is also home to world's only licensed and operating transuranic nuclear waste repository, the DoE's Waste Isolation Pilot Plant (WIPP). Plutonium isotopes ({sup 239+240}Pu) and {sup 241}Am, are expected to account for more than 99% of the total radioactivity scheduled for disposal in the WIPP repository. Thus, an improved understanding of the environmental fate and transport of TENORM, liberated by unconventional drilling, is essential to assess how best to protect individuals and the environment. In this context, accurate measurement of TENORM and actinides in environmental and biological samples is essential. In this presentation, a new sequential method for the separation and pre-concentration of actinides (Pu, Am, Np) and TENORM (Po, U and Th) derived from oil and gas exploration is proposed. The TEVA method involves a rapid co-precipitation step to remove matrix interferences from the samples, followed by plutonium oxidation state adjustment to Pu (IV) and an incubation period of ∼ 1 hour at 50-60 deg. C to allow the resultant Po (II) to oxidize into Po(IV). The polonium, neptunium, thorium and plutonium are then separated on a TEVA column, while americium and uranium are separated on a TRU column. After separation, the alpha counting source was prepared by micro-precipitation with copper sulfide (CuS) for polonium and neodymium fluoride (NdF{sub 3}) for actinides. The efficiency and reliability of the procedures were tested by analyzing filter, drinking water and frack sand samples. The method is simple, robust and can be performed quickly with excellent removal of interferences, high chemical recovery and very good alpha peak resolution. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Development of a New Clearance Monitor for Exemption of NPP Radioactive Wastes and its Performance Test - 17200

In nuclear power plants, it is common practice to clear radioactive wastes for free release by using clearance monitor with plastic scintillation detectors so as to reduce disposal costs. These monitors are possible in part thanks to the excellent detection levels achievable with high energy and high yield photons emitted from contaminants such as Cs-137 and Co-60. However, it is difficult for the monitors to separate Naturally Occurring Radioactive Materials (NORM) from the radioactive wastes because the plastic scintillation detectors have poor resolution compared to NaI or HPGe detectors. KHNP has developed a new clearance monitor for determining whether or not the radioactivity level of metal scraps satisfies regulatory criteria. The monitor is composed of 12 large area plastic scintillation detectors and 3 NaI scintillation detectors. The measuring chamber is surrounded by a 5 cm-thick lead shield with chamber dimensions of 1.5 m x 1.0 m x 1.0 m. Its algorithm has a function of measuring total gamma activity while analyzing gamma nuclides and identifying 27 hotspots in radioactive wastes. The detection limit of this system, according to the MCNP simulation, was determined to be about 45 Bq for Co-60 and 78 Bq for Cs-137 with the condition of an empty chamber and measuring time of 1 minute. We evaluated the self - shielding effect of waste for background correction factor and waste height (volume in the chamber) correction factor. We also tested its MDA, location determination of hot-spots, temperature compensation function and convenience of operation. In the future, we will plan to install it at a nuclear site for more tests including evaluating its durability. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Retrospective Assessment of Correlation between Occupational and Public Radiation Protection Programs Performance Metrics at a FUSRAP Site - 17546

A retrospective assessment of the occupational and environmental radiation protection programs includes the consideration of performance metrics at the qualitative and quantitative level. When key radiation protection (RP) program metrics are tracked over the course of several years, correlations may present themselves. Strong correlations between variables may be considered when establishing or validating baseline RP Program elements (i.e., controls, monitoring regimes, and additional ALARA measures) for the safe excavation and handling of naturally occurring radioactive materials comingled in soil-like wastes at FUSRAP sites. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

A Comparison of GoldSim, RESRAD-Onsite, and NORMALYSA Modeling Tools at Radioactive Waste Sites - 19480

Radioactive waste disposal and associated decision making is a challenging problem around the world. A strong performance assessment model plays a crucial role in making good management and remediation decisions and in optimizing the performance of a site. The International Atomic Energy Agency (IAEA) MODARIA II Working Group 1 (WG1) is comparing the performance of various modeling platforms used at Naturally Occurring Radioactive Material (NORM) and legacy waste sites to support risk-informed decision making. Neptune and Company, Inc. (Neptune) has developed probabilistic performance assessment models using the GoldSim system modeling software at a variety of radioactive waste sites. This paper presents a comparison between GoldSim and two other tools used to evaluate radiation exposure and their associated risks: the NORM And Legacy Site Assessment (NORMALYSA) tool used to assess risk at the Zapadnoe mill tailings site, and the residual radioactivity (RESRAD-Onsite) computer program used to calculate Authorized Limits at the Los Alamos National Laboratory (LANL). The International Atomic Energy Agency (IAEA) supported development of NORMALYSA based off of Ecolego 6.0, in which the user connects several universal modules, representing various environmental transport and exposure pathways, and enters in site-specific data. Further work with NORMALYSA has continued under the MODARIA II WG 1. A radionuclide transport and dose calculation model of the Zapadnoe uranium mill tailings site at the Pridneprovsky Chemical Plant in the Ukraine has been configured by MODARIA II WG1 to test the capabilities of NORMALYSA. Under this test case, contaminant transport and effective dose calculations were performed for two exposure scenarios. The onsite worker is exposed via external ground irradiation and radon and radioactive dust inhalation. The offsite resident defines a residence established 300 years after institutional control has ended, 800 meters downstream from the site with exposure pathways including: ingestion of garden vegetables irrigated by contaminated ground water, ingestion of fish from the Konoplyanka River and agricultural activities in the contaminated garden. GoldSim modeling software is a dynamic probabilistic modeling platform that evaluates uncertainty in a robust and transparent manner. Although GoldSim provides contaminant and radionuclide transport modules to facilitate integrated modeling of radionuclide migration in the environment, these features are not embedded in an existing modeling framework, except as created by the user. Neptune developed a GoldSim model for the two exposure scenarios of the Zapadnoe test case. Neptune's Generic PA Model was used as a starting point for the Zapadnoe site. Input parameters for the GoldSim model include site-specific parameters from the MODARIA Working Group as well as parameters from the Generic PA Model and other PA models created by Neptune. For the other comparison, Version 7.0 of RESRAD-Onsite, developed by Argonne National Laboratory for the U.S. Department of Energy (DOE), was used to calculate Authorized Limits for LANL. Authorized Limits are concentrations of radionuclides in soil that support the evaluation process to clear land for release under different uses. The RESRAD-Onsite computer code was used to calculate Authorized Limits because this program was specifically designed to derive radionuclide soil guidelines corresponding to a specific dose criterion. The scope of the RESRAD dose or risk evaluation is constrained to the transport and exposure pathways that have been included in the computer code. To assist in illustrating the capability of GoldSim modeling software, a GoldSim model was created to replicate the calculation of LANL's Authorized Limits for soil. The main exposure pathways in this model are inhalation of dust and gas, plant ingestion, soil ingestion, and external ground irradiation. All of the processes and outputs of RESRAD-Onsite and NORMALYSA can be created in a GoldSim model, but the value of GoldSim lies in its flexibility for application to any of a wide variety of environmental modeling problems. GoldSim allows development of site-specific inventory, transport mechanisms and risk assessment scenarios. If all potentially complete release, transport, and exposure pathways are addressed in an existing dose and risk assessment computer code, and if the code's capabilities fulfill the project modeling objectives, then expending resources to create a GoldSim model may not be necessary. Site optimization and good decision making about site management are often best when supported with the flexibility of GoldSim as a modeling tool. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

GPS-Based Gamma Survey for Characterizing and Decommissioning NORM Sites - 20389

Gamma survey techniques are an especially powerful decommissioning tool at naturally occurring radioactive material (NORM) sites due to both the low cost to obtain data over a large spatial scale and the abundance of gamma emitters in the uranium and thorium decay series. Gamma surveys are executed by coupling a detector - most often a sodium iodide crystal - to a global positioning system (GPS), then reporting a location and gross gamma reading coincidentally to a data logger. Systems may be carried by workers or mounted to a car, all-terrain vehicle, or unmanned aerial system (UAS). The resulting data set provides a high-resolution but low precision map of the gamma radiation field over the area surveyed. Frequently this map is also correlated to soil concentrations of NORM radionuclides (most often, Ra-226) and/or exposure rate. Gamma survey parameters such as movement speed, transect spacing, and data logging frequency define the spatial resolution of the resulting surface, and can be optimized depending on the desired survey sensitivity. This paper examines gamma survey as a tool for decommissioning NORM sites and provides an overview of current gamma survey technology designed to improve the efficiency and effectiveness of the decommissioning process. Topics to be discussed in the paper include: - An overview of gamma survey systems, and the utility of different delivery vehicles depending on desired cost, desired spatial resolution, and site topography. - The influence of physical detector characteristics on detection sensitivity and survey planning. - The tradeoff between high-resolution and large spatial extent, but inherently uncertain data, and low-resolution, low spatial extent, but highly certain data, as well as the specific utility of each of these types of data during NORM facility decommissioning. - Confounding variables that may limit the utility of gamma survey at some sites (e.g., radon gas and spatial heterogeneity / hot spots), and methods to plan for and control these conditions. Results show that the confounding variables, such as radon and data output can greatly influence the overall data quality associated with the decommissioning process. In addition, the use of real-time and aerial survey platforms provides a method for ensuring proper spatial extent of the data. When applied thoughtfully, gamma survey is a powerful tool for detecting NORM radionuclides in the environment and a cost-effective technique for identifying areas requiring remediation. However, entities performing or using gamma survey as a decommissioning tool must be aware of both its advantages and its limitations before basing remediation or regulatory action on gamma survey results. (authors)