Ytterbium laser system for studying parametric amplification of femtosecond pulses with a centre wavelength of ∼2 μm

A laser system is developed with an optical synchronisation of a femtosecond signal with a pump channel. The signal of a driving ytterbium fibre laser with a 60 MHz repetition rate of stretched femtosecond pulses is amplified in energy from several nanojoules to 0.4 mJ at a pulse repetition rate of 3 kHz in a wideband amplifier and then is compressed in time to 250 fs. The obtained radiation is used for generating femtosecond laser pulses with a centre wavelength of ∼2 μm, pulse energy of above 20 μJ, duration of several field oscillations, and phase stabilisation between the electromagnetic field and envelope. The other pulse of the driving fibre laser provides optical synchronisation and a minimal time delay and is directed to a regenerative Yb : YAG disk amplifier for amplification to an energy of 4 mJ at a pulse repetition rate of 3 kHz and duration of 20 ps. A multipass disk amplifier is developed for further increasing the energy of pump chirped pulses to an energy of 70 mJ at a pulse repetition rate of 10 Hz and duration of 400 ps for studying parametric amplification under sub-nanosecond pumping. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-colour digital holographic microscopy based on a Mach – Zender interferometer and a solid-state RGB laser

We have developed a facility for recording colour digital holograms involving a Mach – Zender interferometer and a pulsed solid-state RGB laser, which radiates simultaneously at three wavelengths: 451, 532, and 634 nm. These wavelengths are obtained in the conversion of the radiation of a pulsed Nd{sup 3+} : YAG laser (1064 nm), which operates in the regime of intracavity parametric oscillation at a wavelength of 1570 nm, with the subsequent conversion of its frequencies to the red, green, and blue spectral regions in nonlinear KTP-crystal elements. The combination of this three-wavelength pulsed light source with the Mach – Zender interferometer provides the simultaneous recording of three spectral digital holograms with one matrix RGB radiation detector. Pulsed three-colour digital holography shows promise for the analysis of fast processes and rapidly varying colour phase objects. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technology of thin-rod Yb : YAG amplifiers with a high pulse energy and average power

Technology for producing thin-rod Yb : YAG laser amplifiers is improved, which is aimed at increasing the output pulse energy and includes the development of a new method for mounting active elements into a cooling system and employment of more persistent dielectric coatings of rod ends. An influence of a thermal lens on the beam size in an active element is theoretically studied and the parameters are found, which provide equal beam sizes at input and output rod ends. The output pulse energy of 4 mJ is obtained without optical breakdown of the output end, which substantially exceeds the previously obtained results. The amplifier demonstrates an average power of 60 W and maintains a high beam quality. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Inhomogeneous broadening and splitting of lines in spectra of YAG : Tm

The shape and fine structure of lines due to Tm{sup 3+} f −f electronic transitions in multifunctional Y{sub 3}Al{sub 5}O{sub 12} garnet crystals have been studied by high-resolution spectroscopy. The observed inhomogeneously broadened lines have a Lorentzian shape, suggesting that point defects make a predominant contribution to the inhomogeneous broadening. Moreover, Y{sub Al} antisite defects, which are formed during high-temperature melt growth, produce spectral satellites near the main lines. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transportable lunar-ranging system.

Description of a transportable transmitting unit for measuring distances to retroreflectors on the moon. The unit can be installed at any astronomical observatory where a large telescope is available to detect the received signal. The transmitter consists of a high radiance, frequency-doubled neodymium-glass laser and a coude optical system of moderate size. The measurements may eventually be used to study variations in the length of the earth's day, changes in the geographic location of the pole, and the drifting of the continents.

Lehr, C. G.↗

Stimulated parametric fluorescence induced by picosecond pump pulses.

Stimulated parametric fluorescence emission tunable over the range from 0.96 to 1.16 microns has been obtained using a barium sodium niobate crystal pumped by a frequency-doubled and mode-locked neodymium:glass laser. The pump radiation in the form of a train of picosecond pulses produced infrared parametric fluorescence pulses, less than 10 psec in duration and with average peak powers on the order of 300 W when pumped with a power density of 300 MW/sq cm.

Rabson, T. A.↗

An optical radar for airborne use over natural waters

An optical radar for detecting targets in natural waters was built and tested in the Gulf of Mexico. The transmitter consists of a Q switched neodymium glass laser, with output amplified and doubled in KDP to 0.53 micrometer wavelength. The receiver incorporates a noval optical spatial filter to reduce the dynamic range required of the photodetector to a reasonable value. Detection of targets to a depth of 26 meters (84 feet) was achieved with a considerable sensitivity margin. The sensitivity of the radar is highly dependent on the optical attenuation coefficient. In general, measured returns fell between the values predicted on the basis of monopath and multipath attenuation. By means of simple physical arguments, a radar equation for the system was derived. To validate this theoretical model, measurements of optical attenuation and of water surface behavior were also instrumented, and some of these results are given.

Levis, C. A.↗

Investigations of coherent anti-Stokes Raman spectroscopy /CARS/ for combustion diagnostics

Investigations of coherent anti-Stokes Raman spectroscopy (CARS) in a variety of flames are presented. Thermometry has received the primary emphasis in these studies, but species spectral and sensitivity studies will also be described. CARS is generated by mixing a 10 pps, frequency-doubled neodymium 'pump' laser with a spectrally broadband, laser-pumped, Stokes-shifted dye laser. This approach obviates the requirement to frequency scan the dye laser and generates the entire CARS spectrum with each pulse permitting, in principle, instantaneous measurements of medium properties. CARS spectra of N2, CO, O2, H2O, CO2 and CH4 in flames will be presented. In general these spectra exhibit very good agreement with computer synthesized spectra and permit measurements of temperature and species concentration. To illustrate the applicability of CARS to practical combustion diagnostics, CARS signatures from N2 have been employed to map the temperature field throughout a small, luminous, highly sooting propane diffusion flame

Eckbreth, A. C.↗

Sequential-Impulse Generator Uses Fiber-Optics

Light pulse from a ruby or neodymium-glass laser enters miniature optics of repetitive-detonation apparatus. Traveling along a bundle of optical fibers, light strikes laser-sensitive microdetonator and charge explodes. Apparatus then advances next charge in train into position. Possible applications of sequential-impulse generator are in creating shock waves for aerodynamics research and in generating electrical power by magnetohydrodynamics.

Yang, L. C.↗

CARS system for turbulent flame measurements

Simultaneous nitrogen number density and rotational-vibrational temperatures were measured in a turbulent diffusion flame with a Coherent Anti-Stokes Raman Scattering (CARS) instrument. The fuel jet was diluted with nitrogen (20 percent by volume) to allow temperature measurements across the entire jet mixing region. These measurements were compared with fluid dynamics computations. The CARS system incorporated a neodymium YAG laser, an intensified silicon photodiode array detector, and unique dynamic range enhancement methods. Theoretical calculations were based on a parabolic Navier-Stokes computer code. The comparison of these techniques will aid their development in the study of complex flowfields.

Antcliff, R. R.↗

The Lidar In-Space Technology Experiment (LITE)

A spaceborne lidar system is presently being constructed for flight aboard the U. S. Space Shuttle in early 1991. The experiment, Lidar In Space Technology Experiment (LITE), utilizes a neodymium:YAG laser and 0.85 meter effective diameter Cassegranian-configured telescope receiver for making elastic backscatter measurements. The laser will be frequency doubled and tripled simulataneously producing a 10 Hz rate of 200 mJ at 1064 nm, 400 mJ at 532 nm, and 150 mJ at 355 nm. The technological objectives of LITE are to evaluate lidar system operations in space, lidar techniques in space, and to provide a test bed for new lidar technologies in later flights. The measurement objectives include the determination of cloud top and planetary boundary layer heights, the measurement of tropospheric and stratospheric aerosols, and the measurement of temperature and density between 10 to 40 km altitude. Detailed simulations will be presented showing the errors associated with each of these measurement objectives. In addition, the experiment scenario will be described including measurement times, data flow, processing and archival, and initial plans for validation of the LITE data set with correlative measurements.

Mccormick, M. P.↗

Multispecies coherent anti-Stokes Raman scattering instrument for turbulent combustion

A nonintrusive diagnostic system is described which permits simultaneous measurement of temperature, nitrogen number density, and oxygen number density in hostile combustion environments. This system is pumped by a 10-Hz neodymium YAG laser, and signals are detected with an intensified photodiode array and dual photomultipliers. The system utilizes a folded BOXCARS beam arrangement, two probe dye lasers, dynamic range expansion, polarization rejection of nonresonant background, and multiplexing of the signal beams.

Antcliff, Richard R.↗

Master-Oscillator/Power-Amplifier Laser System

Master-oscillator/power-amplifier (MOPA) laser system operates in continuous-wave mode or in amplitude-modulation (e.g., pulse) mode by modulation of oscillator current. Power amplifier is laser-diode-pumped neodymium:yttrium lithium fluoride (Nd:YLF) laser; oscillator is laser diode. Offers relatively high efficiency and power. Because drive current to oscillator modulated, external electro-optical modulator not needed. Potential uses include free-space optical communications, coded laser ranging, and generation of high-power, mode-locked pulses.

Yu, Anthony W.↗

Optical communication in free space

Two classes of laser communication systems for handling very high data rates across inter-satellite distances are considered that provide for high antenna gains, wide modulation bandwidths, and optical receiver sensitivities. System design considerations are based upon the carbon dioxide laser modulation to accommodate digital or analog information, and the neodymium doped YAG laser pulse for digital modulation.

Plotkin, H. H.↗

GaAs laser diode pumped Nd:YAG laser

A 1.5-mm by 3-cm neodymium-ion doped YAG laser rod has been side pumped using a GaAs laser diode array tuned to the 8680-A absorption line, achieving a multimode average output power of 120 mW for a total input power of 20 W to the final-stage laser diode drivers. The pumped arrangement was designed to take advantage of the high brightness of a conventional GaAs array as a linear source by introducing the pump light through a slit into a close-wrapped gold coated pump cavity. This cavity forms an integrating chamber for the pump light.

Conant, L. C.↗

Thermal effects on cavity stability of chromium- and neodymium-doped gadolinium scandium gallium garnet laser under solar-simulator pumping

Results are presented on testing a Cr- and Nd-codoped Gd-Sc-Ga-garnet (Cr:Nd:GSGG) crystal and a Nd:YAG crystal (both of 3.2 mm diam and 76-mm long) for pulsed and CW laser operations using a flashlamp and solar simulator as pumping sources. Results from experiments with the flashlamp show that, at pulse lengths of 0.11, 0.28, and 0.90 ms, the slope efficiency of the Cd:Nd:GSGG crystal was higher than that of the Nd:YAG crystal and increased with pulse width. With the solar simulator, however, the CW laser operation of the Cr:Nd:GSGG crystal was limited to intensities not greater than 1500 solar constants, while the Nd:YAG laser successfully performed for all pump beam intensities available. It was found that the exposure for several minutes of the Cr:Nd:GSGG crystal to pump beam intensity of 3000 solar constants led to its damage by thermal cracking, indicating that a better solar-pumped CW laser performance may be difficult to realize with rod geometry.