Search NASA⌕ Search

SEARCH · Search NASA

Results for “NEUTRON ABSORBER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Neutron monitoring and electrode calorimetry experiments in the HIP-1 Hot Ion Plasma

Results are presented for two diagnostic procedures on HIP-1: neutron diagnostics to determine where neutrons originated within the plasma discharge chamber and electrode calorimetry to measure the steady-state power absorbed by the two anodes and cathodes. Results are also reported for a hot-ion plasma formed with a continuous-cathode rod, one that spans the full length of the test section, in place of the two hollow cathodes. The outboard neutron source strength increased relative to that at the midplane when (1) the cathode tips were moved farther outboard, (2) the anode diameters were increased, and (3) one of the anodes was removed. The distribution of neutron sources within the plasma discharge chamber was insensitive to the division of current between the two cathodes. For the continuous cathode, increasing the discharge current increased the midplane neutron source strength relative to the outboard source strength. Each cathode absorbed from 12 to 15 percent of the input power regardless of the division of current between the cathodes. The anodes absorbed from 20 to 40 percent of the input power. The division of power absorption between the anodes varied with plasma operating conditions and electrode placement.

Reinmann, J. J.↗

NTD-GE Based Microcalorimeter Performance

Our group has been developing x-ray microcalorimeters consisting of neutron transmutation doped (NTD) germanium thermistors attached to superconducting tin absorbers. We discuss the performance of single pixel x-ray detectors, and describe an array technology. In this paper we describe the read-out circuit that allows us to measure fast signals in our detectors as this will be important in understanding the primary cause of resolution broadening. We describe briefly a multiplexing scheme that allows a number of different calorimeters to be read out using a single JFET. We list the possible causes of broadening and give a description of the experiment which best demonstrates the cause of the primary broadening source. We mention our strategy for finding a suitable solution to this problem and describe briefly a technology for building arrays of these calorimeters.

Bandler, Simon↗

Preliminary total dose measurements on LDEF

After spending nearly six years in Earth's orbit twenty stacks consisting of radiation detectors and biological objects are now back on Earth. These Free Flyer Biostack experiments are part of the Long Duration Exposure Facility (LDEF). The major objective of the experiments are to investigate the biological effectiveness of single heavy ions of the cosmic radiation in various biological systems and to provide information about the spectral composition of the radiation field and the total dose received in the LDEF orbit. The preliminary analysis of the thermoluminescence dosimeters (TLD) yields maximum absorbed dose rates of 2.24 mGy day(exp -1) behind 0.7 g cm(exp -2) shielding and 1.17 mGy day(exp -1) behind 12 g cm(exp -2) shielding. A thermal neutron fluence of 1.7 n cm(exp -2)s(exp -1) is determined from the differences in absorbed dose for different isotopic mixtures of lithium. The results of this experiment on LDEF are especially valuable since LDEF stayed for almost six years in the prospected orbit of the Space Station Freedom.

Reitz, G.↗

Ionizing radiation measurements on LDEF: A0015 Free flyer biostack experiment

This report covers the analysis of passive radiation detectors flown as part of the A0015 Free Flyer Biostack on LDEF (Long Duration Exposure Facility). LET (linear energy transfer) spectra and track density measurements were made with CR-39 and Polycarbonate plastic nuclear track detectors. Measurements of total absorbed dose were carried out using Thermoluminescent Detectors. Thermal and resonance neutron dose equivalents were measured with LiF/CR-39 detectors. High energy neutron and proton dose equivalents were measured with fission foil/CR-39 detectors.

Benton, E. V.↗

In-Situ Spectrometry of Neutrons

High energy charged particles of extra-galactic, galactic and solar origin collide with spacecraft structures in Earth orbit outside the atmosphere and in interplanetary travel beyond the Earth's magnetosphere. These primaries create a number of secondary particles inside the structures that can produce a significant ionizing radiation environment. This radiation is a threat to long term inhabitants or travelers for space missions and produces an increased risk of cancer and DNA damage. The primary high energy cosmic rays and trapped protons collide with common spacecraft materials such as aluminum and silicon and create secondary particles inside structures that are mostly protons and neutrons. Charged protons are readily detected and instruments are already in existence for this task. Neutrons are electrically neutral and therefore much more difficult to measure and detect. These neutrons are reported to contribute 30-60% of the dose inside space structures and cannot be ignored. Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary surfaces where astronauts will live and work. We propose to design and build a portable, low power and robust neutron spectrometer that will measure the neutron spectrum from 10 KeV to 500 MeV with at least 10% energy resolution in the various energy intervals. This instrument will monitor the existing neutron environment both inside spacecraft structures and on planetary surfaces to determine the safest living areas, warn of high fluxes associated with solar storms and assist the NSBRI Radiation Effects Team in making an accurate assessment of increased cancer risk and DNA damage to astronauts. The instrument uses a highly efficient proportional counter Helium 3 tube at the lowest energy intervals where .equivalent damage factors for tissue are the highest (10 KeV-2 MeV). The Helium 3 tube may be shielded with a cadmium absorber to eliminate the much less damaging, but more prevalent, thermal and epithermal neutrons and to make the structure of the spectrum more accurate in the 20 KeV-2 MeV range; or a pair of tubes, one shielded and one unshielded, can be combined so that the difference in their counts yields the thermal neutron contribution. The spectrometer also uses a 5mm lithium drifted bulk silicon solid state detector in the medium energy range of 2-20 Mev and two standard silicon surface barrier detectors separated by tens of millimeters behind a I cm thick polyethylene moderator in a stack or telescope arrangement for the high energy neutrons (>20 MeV). In the medium and high energy regions equivalent damage factors are lower but hits from one or a small number of neutrons may prove to be important. The silicon detector systems for medium and high energy neutrons will discriminate against charged particles by using a plastic cesium iodide scintillator of an appropriate geometry monitored by a silicon PIN photodiode.

Maurer, Richard H.↗

A study of the radiation environment on board the space shuttle flight STS-57

A joint NASA-Russian study of the radiation environment inside a SPACEHAB 2 locker on space shuttle flight STS-57 was conducted. The shuttle flew in a nearly circular orbit of 28.5 deg inclination and 462 km altitude. The locker carried a charged particle spectrometer, a tissue equivalent proportional counter (TEPC), and two area passive detectors consisting of combined NASA plastic nuclear track detectors (PNTD's) and thermoluminescent detectors (TLD's), and Russian nuclear emulsions, PNTD's, and TLD's. All the detector systems were shielded by the same shuttle mass distribution. This makes possible a direct comparison of the various dose measurement techniques. In addition, measurements of the neutron energy spectrum were made using the proton recoil technique. The results show good agreement between the integral LET spectrum of the combined galactic and trapped particles using the tissue equivalent proportional counter and track detectors between about 15 keV/micron and 200 keV/micron. The LET spectrum determined from nuclear emulsions was systematically lower by about 50%, possibly due to emulsion fading. The results show that the TEPC measured an absorbed dose 20% higher than TLD's, due primarily to an increased TEPC response to neutrons and a low sensitivity of TLD's to high LET particles under normal processing techniques. There is a significant flux of high energy neutrons that is currently not taken into consideration in dose equivalent calculations. The results of the analysis of the spectrometer data will be reported separately.

Badhwar, G. D.↗

Swift, INTEGRAL, RXTE, and Spitzer Reveal IGR J16283-4838

We present the first combined study of the recently discovered source IGR J16283-4838 with Swift, INTEGRAL, and RXTE. The source, discovered by INTEGRAL on April 7, 2005, shows a highly absorbed (variable N(sub H) = 0.4-1.7 x 10(exp 23) /sq cm) and flat (Gamma approx. 1) spectrum in the Swift/XRT and RXTE/PCA data. No optical counterpart is detectable (V > 20 mag), but a possible infrared counterpart within the Swift/XRT error radius is detected in the 2MASS and Spitzer/GLIMPSE survey. The observations suggest that IGR J16283-4838 is a high mass X-ray binary containing a neutron star embedded in Compton thick material. This makes IGR J16283-4838 a member of the class of highly absorbed HMXBs, discovered by INTEGRAL.

Beckmann, V.↗

Radiation Measurements on the Russian MIR Orbital Station

The Russian Mir orbital station was launched into an orbit with a 51.65 deg inclination in March 1986. It has operated continuously in the altitude range of 380 to 460 km. Almost immediately, cosmonauts began to carry out missions to the station. To date, there have been some 25 Russian missions. As part of the NASA Mir Program, a comprehensive set of radiation measurements were made to map the radiation in all of the Mir module. Numerous radiation measurements have been made on the Mir station throughout its lifetime. However, the comparison of these measurements have been difficult because of different sensitivities of detectors, some active and some passive, differing self shielding and in most cases unknown location shielding. In spite of these complications, very significant progress in the knowledge of the radiation environment onboard the Mir station has been made. These results are directly applicable to expected radiation environment on the International Space Station. In this paper, we describe the combined results from all seven NASA Mir missions. We show: (1) the absorbed dose rate from trapped particles is well correlated with the atmospheric density computed nearly 400 days earlier than the time of observation, (2) developed a relationship between the absorbed dose rate from galactic cosmic rays to the deceleration potential derived using the Climax neutron monitor rate, giving a tool to predict GCR dose rates to +/- 15% nearly 90 days prior to observations, (3) describe the drift of the South Atlantic Anomaly (SAA) with time, (4) compare the predictions of the dose rates as a function of time from the November 6-8, 1998 solar particle event with observations, (5) compare measurements made with NASA Tissue Equivalent Proportional Counter (TEPC) with the ESA DOSTEL device, the Hungarian Pille system, and the Russian R-16 dosimeter. Implications of these measurements for the ISS will be discussed.

Badhwar, Gautam D.↗

Staring at 4U 1909+07 with Suzaku (Research Note)

We present an analysis of the neutron star High Mass X-ray Binary (HMXB) 4U 1909+07 mainly based on Suzaku data. We extend the pulse period evolution, which behaves in a random-walk like manner, indicative of direct wind accretion. Studying the spectral properties of 4U 1909+07 between 0.5 to 90keV we find that a power-law with an exponential cutoff can describe the data well, when additionally allowing for a blackbody or a partially covering absorber at low energies. We find no evidence for a cyclotron resonant scattering feature (CRSF), a feature seen in many other neutron star HMXBs sources. By performing pulse phase resolved spectroscopy we investigate the origin of the strong energy dependence of the pulse profile, which evolves from a broad two-peak profile at low energies to a profile with a single, narrow peak at energies above 20keV. Our data show that it is very likely that a higher folding energy in the high energy peak is responsible for this behavior. This in turn leads to the assumption that we observe the two magnetic poles and their respective accretion columns at different phases, and that these accretions column have slightly different physical conditions.

Fuerst, F.↗

An opaque shell around Hercules X-1

It is suggested that the observed soft X-rays from Her X-1 are the result of an opaque gas shell which surrounds the neutron star at a radius where centrifugal force and the magnetic field impede the gravitational infall of the gas and which absorbs a substantial fraction of the hard X-ray flux, reradiating it as soft X-rays. Two highly idealized models for the shell are constructed in which the radius and temperature are 7000 km and 550,000 K or 1300 km and 1.5 million K, respectively. These models are intended to show that a gas shell with interesting spectral characteristics is likely to occur at a radius of 2000 to 7000 km from the neutron star if the magnetic field impedes the gas infall at this radius and that such a shell is indicated by the soft X-ray observations. A possible geometry is considered wherein the shell is a wide opaque ring at the magnetic equator, becomes transparent at high latitudes, and becomes opaque again at the magnetic poles.

Mccray, R.↗

Martian Radiation Environment Experiment (MARIE)

Space radiation presents a very serious hazard to crews of interplanetary human missions. The two sources of this radiation are the galactic cosmic rays (GCR) and solar energetic particle (SEP) events. The GCR provides a steady source of low dose rate radiation that is primarily responsible for stochastic effects, such as cancer, and can effect the response of the central nervous system. Nuclear interactions of these components with the Martian atmosphere produces substantial flux of neutrons with high Radio Biological Effectiveness. The uncertainty in the knowledge of many fragmentation cross sections and their energy dependence required by radiation transport codes, uncertainties in the ambient radiation environment, and knowledge of the Martian atmosphere, lead to large enough uncertainties in the knowledge of calculated radiation dose in both free space (cruise phase), in Martian orbit, and on Martian surface. Direct measurements of radiation levels, the relative contributions of protons, neutrons, and heavy ions, and Martian atmospheric characteristics is thus a prerequisite for any human mission. An integrated suite of two spectrometers to provide these data will be described. The Orbiter spectrometer will measure the energy spectrum of SEP events from 15 to 500 MeV/n, and when combined with data from other space based instruments, such as the Advanced Composition Explorer (ACE), would provide accurate GCR spectra also. The Lander spectrometer would measure the absorbed dose rate, dose equivalent dose rate, and the linear energy transfer (LET) spectra and is capable of separating the relative contribution of these quantities from protons, neutrons, and high Z particles. There are two separate flight instruments, one for the Orbiter and one for the Lander, based on a common design of the backplane, the central processing unit (CPU), power supply, and onboard data storage. The Orbiter instrument consists of an energetic particle spectrometer that can measure the elemental energy spectra of charged particles over energy range of 15-500 MeV/n. The spectrometer will be mounted on the science deck and has an angular acceptance of 50 degrees. As the spacecraft orbits Mars, the axis of this field of view sweeps a cone of directions on the sky. During each orbit, the angle between the axis of the spectrometer's field of view and the mean interplanetary field direction varies from 90 degrees to 180 degrees. The Lander instrument is designed: (1) to measure the accumulated absorbed dose and dose rate in tissue as a function of time, (2) to determine the radiation quality factor, (3) to determine the energy deposition spectrum from 0.1 keV/micron to 1500 keV/micron, and (4) to separate the contribution of protons, neutrons, and HZE particles to these quantities.

Badhwar, Gautam D.↗

Infrared bolometers with silicon nitride micromesh absorbers

Sensitive far infrared and millimeter wave bolometers fabricated from a freestanding membrane of low stress silicon nitride are reported. The absorber, consisting of a metallized silicon nitride micromesh thermally isolated by radial legs of silicon nitride, is placed in an integrating cavity to efficiently couple to single mode or multiple mode infrared radiation. This structure provides low heat capacity, low thermal conduction and minimal cross section to energetic particles. A neutron transmutation doped Ge thermister is bump bonded to the center of the device and read out with evaporated Cr-Au leads. The limiting performance of the micromesh absorber is discussed and the recent results obtained from a 300 mK cold stage are summarized.

Bock, J. J.↗

An Evolving Broad Iron Line from the First Galactic Ultraluminous X-Ray Pulsar Swift J0243.6+6124

We present a spectral study of the ultraluminous Be/X-ray transient pulsar Swift J0243.6+6124 using Neutron Star Interior Composition Explorer (NICER) observations during the system's 2017–2018 giant outburst. The 1.2–10 keV energy spectrum of the source can be approximated with an absorbed cutoff power-law model. We detect strong, luminosity-dependent emission lines in the 6–7 keV energy range. A narrow 6.42 keV line, observed in the sub-Eddington regime, is seen to evolve into a broad Fe-line profile in the super-Eddington regime. Other features are found at 6.67 and 6.97 keV in the Fe-line complex. An asymmetric broad-line profile, peaking at 6.67 keV, is possibly due to Doppler effects and gravitational redshift. The 1.2–79 keV broadband spectrum from Nuclear Spectroscopic Telescope Array (NuSTAR) and NICER observations at the outburst peak is well described by an absorbed cutoff power law plus multiple Gaussian lines and a blackbody component. Physical reflection models are also tested to probe the broad iron-line feature. Depending on the mass accretion rate, we found emission sites that are evolving from ~5000 km to a range closer to the surface of the neutron star. Our findings are discussed in the framework of the accretion disk and its implication on the magnetic field, the presence of optically thick accretion curtain in the magnetosphere, jet emission, and the massive, ultrafast outflow expected at super-Eddington accretion rates. We do not detect any signatures of a cyclotron absorption line in the NICER or NuSTAR data.

Gaurava K. Jaisawal↗

X-ray suppression in gamma-ray bursts through resonant Compton scattering

An X-ray that scatters with an electron in the first Landau level of a strong magnetic field is converted into a gamma ray. This process has a resonant cross section at X-ray energies and is therefore highly likely to occur even when the first Landau level is sparsely populated. Converted X-rays are cyclotron absorbed, maintaining the equilibrium between the cyclotron photon density and the population of the first Landau level. By suppressing a neutron star's black body emission, this mechanism can produce a gamma-ray burst with a low X-ray flux.

Brainerd, J. J.↗

Status of LDEF ionizing radiation measurements and analysis

At this symposium significant new data and analyses were reported in cosmic ray research, radiation dosimetry, induced radioactivity, and radiation environment modeling. Measurements of induced radioactivity and absorbed dose are nearly complete, but much analysis and modeling remains. Measurements and analyses of passive nuclear track detectors (PNTD), used to derive the cosmic ray composition and spectra, and linear energy transfer (LET) spectra, are only a few percent complete, but important results have already emerged. As one might expect at this stage of the research, some of the new information has produced questions rather than answers. Low-energy heavy nuclei detected by two experiments are not compatible with known solar or cosmic components. Various data sets on absorbed dose are not consistent, and a new trapped proton environment model does not match the absorbed dose data. A search for cosmogenic nuclei other than Be-7 on Long Duration Exposure Facility (LDEF) surfaces has produced an unexpected result, and some activation data relating to neutrons is not yet understood. Most of these issues will be resolved by the analysis of further experiment data, calibrations, or the application of the large LDEF data set that offers alternate data or analysis techniques bearing on the same problem. The scope of the papers at this symposium defy a compact technical summary. I have attempted to group the new information that I noted into the following groups: induced radioactivity; absorbed dose measurements; LET spectra and heavy ion dosimetry; environment modeling and three dimensional shielding effects; cosmogenic nuclei; and cosmic rays and other heavy ions. The papers generally are expository and have excellent illustrations, and I refer to their figures rather than reproduce them here. The general program and objectives of ionizing radiation measurements and analyses on LDEF has been described previously.

Parnell, Thomas A.↗

Characteristics of the persistent emission of SGR 1806-20

Earlier, using the X-ray satellite ASCA, we had identified the soft gamma-ray burst repeater (SGR) 1806-20 with a persistent X-ray source, AX 1805.7-2025 which is located close to the center of the radio supernova remnant G10.0-0.3. A burst seen by Burst and Transient Source Experiment (BATSE) was shown to be centered on G10.0-0.3. Here we report detailed temporal and spectral analysis of the persistent source. We find that AX 1805.7-2025 is a very compact source, size less than 30 sec in diameter, with a power-law spectrum. The count rate from AX 1805.7-2025 is steady on timescales of minutes, days, and 1 week. Most supernova remnants have extended X-ray emission ascribed to shocked gas. We set an upper limit to an extended X-ray emission both in continuum and line emission. We conclude that an isolated neutron star, most likely a pulsar, powers the radio remnant G10.0-0.3. Finally, we note that the persistent spectrum appears to be less absorbed than the burst spectrum.

Sonobe, T.↗