Search NASA⌕ Search

SEARCH · Search NASA

Results for “NEUTRON COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Operation of the Fast Neutron Coincidence Collar (FNCL) with a DD-Neutron Generator

For more than 30 years, the quantitative assay of the 235 U content of light water reactor fresh fuel assemblies relied on measuring coincidence neutrons from fissions induced by an Am(Li) neutron source using 3 He based detectors. The Fast Neutron Collar (FNCL) developed by the International Atomic Energy Agency (IAEA), replaces traditional 3 He proportional counters with an array of liquid scintillator detectors arranged about the fuel assembly to provide improved measurement precision and reduced sensitivity to gadolinium poison rods. The FNCL relies on Am(Li) neutron sources that are no longer commercially available. This work examines the replacement of Am(Li) sources with a commercial off the-shelf deuterium–deuterium (DD) neutron generator. In addition to mitigating supply concerns, the neutron generator offers advantages in measurement precision and potential automation of sequential passive/active neutron measurements. This report presents the initial performance results for both the integrated DD/FNCL and Am(Li)/FNCL assays of compact depleted uranium, low-enriched uranium, and highly enriched uranium standards along with an estimate of the expected performance for fresh fuel assemblies. A discussion of the design and operation of the “FNCL Analysis and Simulation Software” is also provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Evaluation of a Neutron Time Correlated Interrogation Method for Measurement of Fissile Content in Research Reactor Spent Fuel Assemblies

There are many research reactors worldwide that have been, or are being converted from the use of high enrichment uranium (HEU) to low enrichment uranium (LEU, < 20% enriched). The verification of fissile content and initial enrichment of the spent fuel is needed for the effective safeguards of the fuel. The advanced experimental fuel counter (AEFC) was developed for the measurement of spent fuel rods and assemblies from research reactors for safeguards verification. This measurement system contains components for active neutron interrogation, passive neutron totals counting, neutron coincidence counting, and gross gamma-ray counting. This report presents the first application of the time correlated interrogation technique for the measurement of the 235 U content in research reactor spent fuel assemblies. The technique, called time correlated induced fission (TCIF), uses a 252 Cf neutron source to irradiate the fuel assembly, and the subsequent induced fission events in the fissile material are measured by coincidence counting. The doubles rates are enhanced by having the neutron trigger events from both the 252 Cf source and the induced fission neutrons in the same time gate in the coincidence analysis. The average neutrons per fission of the 252 Cf source is 3.76 and the induced fission neutrons for 235 U is 2.44, so the number of neutrons that are produced is higher than for random neutron interrogation. This high effective neutron number increases the multiplicity counting rates and reduces the statistical error. The background coincidence counts from the 252 Cf are reduced by the water in the sample cavity and the polyethylene surrounding the 3 He detector tubes. This method of active neutron interrogation has been applied to the measurement of spent research reactor (IRT) fuel assemblies. The advanced experimental fuel counter (AEFC) was used to compare the TCIF method with the typically used AmLi neutron interrogation source that emits neutrons that are random in time. The statistical uncertainty for the use of the random neutron source (AmLi) and the time correlated source ( 252 Cf) for spent fuel interrogations was evaluated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Large area position sensitive detector for thermal neutrons

Large area thermal neutron detectors are applied in many fields including industrial imaging, nuclear safeguarding, neutron scattering, and fundamental science. Historically, these detectors were based on 3 He gas proportional counters despite the limitations of 3 He detectors such as high cost, limited supply, non-uniform spatial resolution, and depth of absorption problems. Two alternatives to 3 He detectors are 6 Li-loaded glass scintillators, and powdered ZnS(Ag) scintillators mixed with 6LiF neutron converters. The 6 LiF/ZnS(Ag) scintillator has advantages over 6 Li glass as it is less expensive and can be produced in larger areas, although its self-absorption presents a problem. In this work, we developed a large area thermal neutron detector based on 6 LiF/ZnS(Ag) scintillator coupled with wavelength shifting fibers. The detector uses resistive charge divider-based position encoding. We further modified and improved the method by 2D segmentation of the detector using modular multichannel readout electronics. This segmentation approach allows for a combination of large detector area, improved spatial resolution, and increased count rate. Furthermore, spatial resolution can be variable across the detector area by adjusting the segment size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the 240 Pu(n,f) Prompt Fission Neutron Spectra with Chi-Nu

The DOE Nuclear Criticality Safety Program has funded a multi-year effort to measure the 240 Pu(n,f) Prompt Fission Neutron Spectrum at Chi-Nu. This project is a joint LANL-LLNL effort, involving the preparation of 12 240 Pu foils and construction of a Parallel-Plate Avalanche Counter at LLNL, with subsequent measurements of the 240 Pu(n,f) PFNS at the Chi-Nu beamline at the Los Alamos Neutron Science Center’s Weapons Neutron Research facility (LANSCE/WNR). We expect the PPAC to be ready in time to perform the measurements this run cycle.

240Pu Foils↗

UFCC Calibration Measurements for UO2 Samples

The uranium UF 6 coincidence counter (UFCC) was designed to measure 5A/B cylinders containing UF6 in the passive neutron self-interrogation mode. The purpose of the present report is to extend the UFCC capability to other sample types such as oxides and liquids that might be found during verification activities. A 252 Cf source was introduced into the detector to make the active mode measurements possible, because only the UF 6 samples have adequate neutron emission for self-interrogation. A customized HDPE insert was designed to position the 252 Cf source under the UO 2 sample cans. The sample enrichments varied from depleted to 93% to establish the shape of the calibration curve and the measurement uncertainties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying the chemical, electrochemical heterogeneity and spatial distribution of (poly) sulfide species using Operando SANS

In-situ and operando measurements are done to gain a better understanding of the precipitation mechanisms during charge and discharge in lithium sulfur batteries. A carbon felt networked with microfibers consisting of pores, 2 nm and smaller, is used as a freestanding sulfur host. Three different methods of sulfur infiltration are explored in order to determine the best one to fill most of the pores. It was identified to be a melt infiltration method in a vacuum oven, where the pores including the ultra-micropores, are successfully filled. In-situ electrochemical impedance spectroscopy measurements show a solid product formation occurring at the sulfur cathode, both during the high voltage plateau and at the end of discharge. In a 3-electrode EIS measurement, a similar solid product formation on the Li counter electrode due to its reaction with polysulfides is also observed. Operando small angle neutron scattering measurements show the solid product formation, in the carbon, both near the beginning and at the end of discharge, confirming the precipitation data via contrast changes as a function of charge and discharge. It is shown that Li 2 S precipitates in the pores at the beginning and the end of discharge, whereas S8 precipitates on the surface of the carbon felt. Finally, this lithium sulfur system shows both the quasi-solid-state and the solid-liquid-solid reactions in a typical ethereal electrolyte solution with a two-plateau discharge profile.

25 ENERGY STORAGE↗

UFCC Calibration Measurements for Bulk U 3 O 8 Powder Samples

The uranium UF 6 coincidence counter (UFCC) was designed to measure 5A/B cylinders containing UF 6 in the passive neutron self-interrogation mode. The purpose of the present report is to extend the UFCC capability to other sample types such as oxides and liquids that might be found during verification activities. A 252 Cf source was introduced into the detector to make the active mode measurements possible, because only the UF 6 samples have adequate neutron emission for self-interrogation. The sample enrichments varied from 0.72% to 91% to establish the shape of the calibration curve and the measurement uncertainties. The measurements included the singles, doubles, and triples rates. The time correlations between the 252 Cf source and the induced fission reactions reduced the statistical error in the doubles and triples rates to be small enough for useful measurements in 5-10 minutes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interpenetration and kinetic effects in converging, high-energy plasma jets

In this work, we report on numerical simulations of laser-driven convergent plasma fusion targets. These “inverted corona” fusion targets are useful for the study of counter-streaming and converging rarefied plasma flows, and previous experiments have demonstrated their potential as neutron sources. The scheme consists of a fuel layer lined along the interior surface of a hollow plastic shell that is laser-ablated and expands inward towards the target center. The plasma streams generated in these targets are initially nearly collisionless as they converge, leading to wide interaction length scales and long interaction time scales as the jets interpenetrate. Such kinetic effects impact mixing of constituent ions - a phenomenon not properly captured by single-fluid hydrodynamic simulations. Here we conduct numerical simulations using two different methods: (1) single-fluid simulations in HYDRA, and (2) kinetic-ion, fluid-electron hybrid particle-in-cell (PIC) simulations in the code Chicago. It is shown that the initially nearly collisionless plasma fronts interpenetrate deeply and lead to broader interaction regions in space and time resulting in significant beam-beam fusion. The two approaches make different, testable predictions for the effect of fuel-layer thickness on neutron yield.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of AmLi Sources for Active Well Coincidence Counter

To support the use of the Oak Ridge National Laboratory (ORNL) large-volume active well coincidence counter (LV-AWCC) in material control and accountancy (MC&A) measurements, a set of AmLi neutron sources was acquired from Savannah River National Laboratory (SRNL). These sources were measured to verify their suitability for use in the ORNL LV-AWCC. The sources produce neutrons at a rate that is within 4% of the rate for one set of AmLi sources already in use and 40% higher than the rate for the other set. These measurements indicate that the SRNL sources are suitable for use in the LV-AWCC because their sensitivity and measurement precision will be similar to those of the sets already in use. However, the SRNL sources still need to be evaluated for MC&A use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New segmented target for studies of neutron unbound systems

The study of neutron-unbound systems using invariant mass spectroscopy is often performed using low-intensity radioactive ion beams. Low reaction yields can be countered by using thick targets but at the expense of larger uncertainties in the reconstructed invariant mass. In this work, we present a new segmented target designed to address this trade-off. It is composed of three mm thick passive beryllium targets interleaved between four thick position sensitive silicon detectors. In the first experiment to use this new system the half-life of two-neutron unbound was measured to be (stat) (syst) ps, which agrees with a previous measurement made by the MoNA Collaboration.

47 OTHER INSTRUMENTATION↗

Rossi-alpha measurements of fast plutonium metal assemblies using organic scintillators

The reactivity and the k-effective multiplication factor (k eff ) of a fissionable assembly are quantities of widespread interest. These values can be inferred from Rossi-alpha measurements of the prompt neutron decay constant (or the inverse:α -1 ). It has been shown that 3 He-gas proportional counter-based detection systems are insensitive to α -1 of fast assemblies (much faster than tens of microseconds). Therefore, it is of interest to investigate fast detection systems such as those based on organic scintillation detectors. In this work, an array of 12 cylindrical, 5.08 cm x 5.08 cm diameter trans-stilbene organic scintillators was used to measure five subcritical assemblies. One assembly was a sphere of approximately 4.5 kg of alpha-phase, weapons-grade plutonium (k eff = 0.773, α -1 = 11.84 ns) known as the BeRP ball encased in a thin stainless-steel clad. The other assemblies used the same encased sphere and 7.62 cm of iron, nickel, copper, or tungsten reflectors (k eff = 0.884, 0.916, 0.924, 0.939, respectively and α -1 = 36.60, 41.56, 49.60, 70.32 ns, respectively). Finally, this work (1) validates Rossi-alpha measurements with organic scintillators by demonstrating good agreement between measurements and simulations; and (2), demonstrates that organic scintillator-based systems are sensitive to α -1 on the order of 10–100 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring aerosol collection efficiency for the Bladewerx “New Speclon TM 5” and the older “Speclon TM 5” filter

Bladewerx TM LLC (Rio Rancho, NM) manufactures instrumentation, neutron shielding and activation foils for the radiation protection industry. Specializing in portable alpha/beta air monitors and sample counters, Bladewerx is the source of Speclon TM PTFE filter media that they recommend for high-resolution alpha spectroscopy. Los Alamos National Laboratory (LANL) utilizes Speclon TM filter material in CAM (Continuous Air Monitor) samplers for workplace air monitoring. The LANL Aerosol Engineering Facility received air filter material from Bladewerx, referred to as “New Speclon 5” in this document, in order to distinguish from filter material that was previously received (referred to as “Speclon 5” in this document). In this document, the aerosol collection efficiency and airflow resistance (pressure drop) were measured for the New Speclon 5 filter material.

61 RADIATION PROTECTION AND DOSIMETRY↗

A summary of air sampler filter performance data: Bladewerx Speclon 5(TM) and Millipore FMLW047 5um

Bladewerx™ LLC (Rio Rancho, NM) manufactures instrumentation, neutron shielding and activation foils for the radiation protection industry. Specializing in portable alpha/beta air monitors and sample counters, Bladewerx is the source of Speclon 5™ PTFE filter media that they recommend for high-resolution alpha spectroscopy. Los Alamos National Laboratory (LANL) utilizes Speclon™ filter material in CAM (Continuous Air Monitor) samplers for workplace air monitoring. Millipore FMLW (5μm) filters are also used at Los Alamos, and a comparison of the two filter types has been requested. For filter face air velocities from 0.066 m/s to 1.5 m/s, the aerosol collection efficiency (for 0.3 μm particle diameters) and the filter pressure drops were measured. The FWHM (full width half maximum) of alpha spectroscopy peaks was also determined, using naturally occurring radon progeny at an alpha energy of 6 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

Neutron Spectrum and 10B(n,α) Measurements in ZPPR-15

Neutron spectra were measured at the core center with proton recoil spectrometers in ZPPR15A loading 66, ZPPR-15B loading 90 and ZPPR loading 186. In addition, neutron spectra were measured in the SSNA shield configuration in ZPPR-15B loading 121 and in the BCNA shield configuration in ZPPR-15B loading 126. The ZPPR-15 neutron spectrum measurement and data processing techniques were described and analyzed. Total uncertainties were derived for all five spectrum measurements. A back-to-back proportional counter was used to measure the 10 B(n,α) reaction rate at six locations in the simulated shield, radial reflector and outer core in the ZPPR-15B BCNA shield experiment. The measurements were described and analyzed. A total uncertainty was derived for the 10 B(n,α) reaction rate measurements. The ZPPR-15 experimental records were used to develop detailed as-built Monte Carlo models for the five neutron spectrum measurement configurations and for the six 10 B(n,α) measurement configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LANL/LLNL 240 Pu( n,f ) Prompt Fission Neutron Spectrum Measurement (Q4 FY2022 Progress Report)

The report details the joint LANL/LLNL measurement of the 240 Pu( n,f ) prompt fission neutron spectrum (PFNS) for incident neutron energies from 1–20 MeV. A summary of the experimental setup, including details of the parallel-plate avalanche counter (PPAC) used for this experiment, beam time awarded and received, and adaptations made for specifically for this experiment are described in Sec. II. Some preliminary results obtained with a portion of the total available statistics from the executed experiment are then described in Sec. III with a discussion of potential benefits and losses if more data were collected. Finally, some primary tasks remaining to convert these data to final results are discussed in Sec. IV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiplicity counting using organic scintillators to distinguish neutron sources: An advanced teaching laboratory

In this advanced instructional laboratory, students explore complex detection systems and nondestructive assay techniques used in the field of nuclear physics. After setting up and calibrating a neutron detection system, students carry out timing and energy deposition analyses of radiation signals. Through the timing of prompt fission neutron signals, multiplicity counting is used to carry out a special nuclear material (SNM) nondestructive assay. Our experimental setup is comprised of eight trans-stilbene organic scintillation detectors in a well-counter configuration, and measurements are taken on a spontaneous fission source as well as two (α,n) sources. By comparing each source's measured multiplicity distribution, the resulting measurements of the (α,n) sources can be distinguished from that of the spontaneous fission source. Such comparisons prevent the spoofing, i.e., intentional imitation, of a fission source by an (α,n) neutron source. This instructional laboratory is designed for nuclear engineering and physics students interested in organic scintillators, neutron sources, and nonproliferation radiation measurement techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Universality of Collective Density Fluctuations in Liquids at and away from Equilibrium – An Integrated Neutron Scattering, Theoretical, and Computational Study (Final Technical Report)

Liquids, ubiquitous on earth, are prototypical disordered condensed matter. As the mediate phase between non-structured gases and ordered solids, liquids p ossess intriguing complexities that are absent on either extreme counter phase, especially when they are driven away from equilibrium. Despite decades of studies, the physics of liquids still keeps surprising us and challenges our understanding of condensed matter, emergent phenomena, and complex systems. Among the many interesting properties, the nature of collective dynamics in liquids remains elusive because of both the presence of strong interactions and the absence of translational invariance. This project studied the universal features of collective density fluctuations (or collective modes), which include both phonon-like excitations and collective relaxations, in the Q-dependent generalized hydrodynamic regime in liquids and liquid-like matter both at and away from equilibrium. We performed systematic studies of the fast collective dynamics (including both phonon-like excitations and collective relaxations) of four classes of liquids characterized by different fragilities and interactions using synergistically integrated coherent neutron scattering experiments (Inelastic Neutron Scattering (INS), Quasi-Elastic Neutron Scattering (QENS), and Neutron Spin Echo (NSE)), a ViscoElastic Hydrodynamics theory we have been developing, andMolecular Dynamics (MD) simulations and our analysis package LiquidLib. The transformative knowledge of the collective dynamics in liquids is important to understand and ultimately control the transport of mass, energy, and charge in liquids, both at and away from thermal equilibrium, which may will likely impact a wide range of disciplines.

36 MATERIALS SCIENCE↗