Search NASA⌕ Search

SEARCH · Search NASA

Results for “NO cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Coating to cool a surface by passive radiative cooling

Disclosed herein in is a radiative cooling formulation including a first component with >55% reflectance in a wavelengths range of 0.3 to 2.5 microns, a second component with a first thermal emissivity peak value greater than 0.85 at a first wavelength in a range of 8 to 13 microns (μm), and a third component to mechanically bind together a mixture of the first component and second component.

Van Overmeere, Quentin↗

Corrigendum to “Cool Rooms for Indoor Heat Resilience: Evaluating Affordable Cooling Strategies in Heat-Stressed California Homes” [Building and Environment 287 (2026) 113877]

The authors regret an error in the acknowledgments section regarding the U.S. Department of Energy Solar Energy Technologies Office award number. The previously listed grant number, 2597–1625, was incorrect. The corrected acknowledgment should read: “This work was supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Building Technologies of the United States Department of Energy (DOE), under Contract No. DE-AC02–05CH11231. This material is based upon work supported by the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE) under the Solar Energy Technologies Office Award Number DE-EE00040384. Any opinions, findings, and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily reflect the views of the Department of Energy.” The authors would like to apologise for any inconvenience caused.

Malik, Jeetika↗

Data Center Immersion Cooling: A Case Study and Summary of High-Performance Computing Cooling Technologies

The future of High Performance Computing (HPC) is carved out for all high-performance facilities. As computer processing increases exponentially, especially with the demand for AI training, more speed will equate to more computing density and ultimately more power draw and resource demand. Sandia National Laboratories has not seen or known of anything that would lead us to think this might change in the next 5 to 10 years.

97 MATHEMATICS AND COMPUTING↗

Revolutionizing Turbine Cooling with Micro-Architectures Enabled by Direct Metal Laser Sintering

The objective of this research effort was to explore innovative cooling architectures enabled by additive manufacturing techniques for improved turbine cooling performance. The ability to create complex internal geometries was leveraged to better distribute coolant as well as to integrate inherently unstable flow devices to enhance internal and external heat transfer. This was accomplished with a multi-faceted approach including analytical, experimental, and computational components. This final report documents progress during the total 4.25 year effort that was extended (at no additional cost) from the original 3-year cooperative agreement. Prior to starting the project, significant effort was invested in investigating innovative cooling designs from the open literature. When the project started, we quickly down-selected to 4 configurations: impingement jet fluidic oscillators (for internal leading edge cooling), reverse film cooling (for pressure surface), sweeping film cooling jets (for suction surface), and trailing edge slot cooling with microchannels. During the 2nd year, the reverse film cooling design was shown to be sub-optimal and work on that topic was halted. The three remaining technologies were integrated into a large scale nozzle guide vane and installed into a low-speed linear cascade facility for further interrogation. Initial results showed the sweeping film cooling jets (on the suction surface) to be the most promising technology compared to a baseline diffusion shaped film hole (777 design). The benefit was particularly evident at high blowing ratios (>1.5) when the 777 coolant film separated from the downstream surface. Benefits were also evident at elevated freestream turbulence levels. The leading edge cooling with unsteady jets was less effective in terms of peak or average cooling – however it was superior to round hole impingement cooling in terms of spatial uniformity. Finally, the trailing edge cooling design with micro-channels was scrapped in favor of a pinned arrangement with centerbody. During the 3rd year, the same three technologies were integrated into a transonic linear cascade for an assessment of compressibility effects. Again, the sweeping film cooling jets proved superior at high blowing ratios while the unsteady leading edge impingement and trailing edge pin-fins with centerbody designs yielded mixed results. Finally, during the 4th and final year, these 3 technologies were integrated into a direct metal laser sintered (DMLS) nozzle guide vane for testing in a high temperature, transonic annular vane cascade. The facility matches the flow temperature, Mach number, and coolant pressure ratios of an actual gas turbine. Before doing this, an additional series of tests were completed to validate a redesigned trailing edge cooling architecture. This final design included a centerbody with triangular pins between the centerbody and the vane external skin. The majority of these triangular pins are fabricated with a 30% gap to the centerbody – reducing their pressure drop considerably while still providing excellent heat transfer augmentation. This additional test campaign required an additional 3-month extension request to complete testing in the high temperature NGV test facility (Turbine Reacting Flow Rig – TuRFR). Testing of the DMLS vane in TuRFR pitted the 3 innovative cooling technologies against more traditional technologies (shaped 777 film hole, round impingement jet, and full pin arrangement in the trailing edge. The sweeping film cooling jets (on the suction surface) showed approximately 15% improvement in overall effectiveness compared to the 777 film hole while the trailing edge showed up to 20% improvement. The leading edge impingement was disappointing with a substantially lower effectiveness than traditional direct impingement. In summary, the study was successful in demonstrating that DMLS-enabled cooling technologies can yield significant gains in cooling performance.

03 NATURAL GAS↗

Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage

The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.

01 COAL, LIGNITE, AND PEAT↗

Life cycle assessment of novel heat exchanger for dry cooling of power plants based on encapsulated phase change materials

Cooling systems in power plants account for approximately 40% of total freshwater withdrawals in the U.S. Due to dwindling access to freshwater resources worldwide, continued operation of wet cooling systems poses a significant engineering challenge. To reduce water consumption, a novel air-cooled heat exchanger has been developed using encapsulated phase change material (EPCM) for dry cooling of power plants. Compared to traditional finned-tube air-cooled condensers, this novel EPCM heat exchanger improves the heat transfer coefficient and power plant efficiency while reducing the pressure drop and cooling system cost. Life cycle assessment (LCA) and techno-economic analysis (TEA) are used to evaluate the environmental and economic performance of EPCM heat exchangers from cradle-to-grave and to compare them to wet cooling and traditional air-cooled condensers. A thermodynamic model is developed to predict the EPCM heat exchanger performance for plant-scale operations. Equipment and construction costs for heat exchangers are estimated based on design parameters obtained from the thermodynamic model. Both process-LCA and economic-input–output LCA are used to simulate and test the sensitivity of EPCM alternatives with commercial wet and dry cooling technologies. We investigate options for EPCM end-of-life management upon retiring the heat exchanger and construct a process-based LCA model to estimate a greenhouse gas (GHG) emissions credit for recycling the EPCM. The life cycle GHG emission of the novel dry cooling technology is 1.16 kg CO 2 eq. /MWh compared with the 1.1–4.3 kg CO 2 eq. /MWh reported for commercial dry cooling technologies and consumes 9.5 L/MWh e of water for cradle-to-gate life cycle, which is significantly lower than that of wet cooling systems. The TEA shows many advantages of EPCM cooling technology over the state-of-art dry cooling solutions. Overall, the EPCM heat exchanger provides a better alternative compared to existing dry cooling and wet cooling technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Turbine Component Cooling Designs Facilitated by Additive Manufacturing and Optimization

This research program involved the development of improved gas turbine cooling by optimizing the combined internal and film cooling configurations used for turbine blades and vanes. Improved cooling of turbine airfoils allows the gas turbines to be operated at higher temperatures which improves efficiency for gas turbine-based power generation. This also facilitates operation with hydrogen-based fuels which inherently generate higher operating temperatures. Designs of the new cooling configurations were based on the added geometric flexibility that is available when using metal additive manufacturing techniques. When making these designs, adjustments were made to account for imperfections occurring in the metal additive manufacturing process. New designs for film cooling holes were developed using computational adjoint gradient optimization techniques which generated a unique film cooling hole with 70% greater film cooling effectiveness compared to conventional shaped film cooling holes. A major factor in improving the film cooling effectiveness were small external protrusions on either side of the new hole which generated vortices that pushed coolant towards the surface and increased the lateral spreading of the coolant. Our studies also included optimization of film cooling holes that can be built with conventional manufacturing techniques and optimizing the internal coolant channels that supply coolant to the film cooling holes. Various internal coolant channel shapes were investigated and designs that maximized the cooling of the airfoil while minimizing pressure losses in the channel flows were identified. Testing and verification of the performance of the final configurations was done with a transonic wind tunnel facility which allowed testing at engine realistic high velocities. Final testing of the combined internal and film cooling configurations was done by incorporating the configurations in Penn State’s National Experimental Turbine (NExT) vane. These tests confirmed the enhanced overall cooling effectiveness provided by the new cooling configuration designs.

03 NATURAL GAS↗

Design And Control of Thermal Storage for Ventilative Cooling in Multifamily Buildings (Final Report)

The concept of natural ventilation is to provide a heat sink for cooling the building during the occupancy periods at night and improve indoor thermal comfort during the daytime without or with minimal need for mechanical cooling. Commonly, natural ventilation through the window or mechanical circulation of the air through the ventilation ducts are two key methods used to achieve night ventilation. Due to the increasing electric need for space heating and cooling, renewable energies combined with energy storage systems are receiving attention worldwide nowadays. When designed and controlled properly, this strategy can reduce energy use for cooling, reduce the size of mechanical cooling equipment, reduce peak electrical demand for cooling, and better enable demand flexibility for mechanical cooling equipment. In some cases, ventilative cooling can eliminate the need for mechanical cooling altogether. For these reasons, California’s Building Energy Efficiency Standards have recently added prescriptive requirements that all new single-family residences (in most California climates) must include ventilative cooling systems (aka: “whole house fans”). However, the current standards do not address multifamily buildings because market-available ventilative cooling products are designed for single-family residences and are physically incompatible with many multifamily building archetypes. The results from the study show that the combination of thermal energy storage on building walls along with nighttime ventilation cooling assisted with nighttime ventilation can save total building energy usage by up to 9% and peak load by 16% in moderate climate zones. The controlled nighttime ventilation cooling (activate ventilation only when outdoor conditions are favorable) can also provide total electricity savings of up to 5% and 7% in hot and cold climates, respectively. In the case of moderate climates, kitchen exhaust-assisted nighttime ventilation cooling can eliminate the need for cooling during overnight hours. This can also significantly assist in reducing carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-Energy Cooling for Electron Ion Collider

Luminosity parameters at the highest hadron energy in the Electron Ion Collider (EIC) require a proton beam with a small vertical emittance. Such a small emittance can be obtained using the technique of electron cooling, by pre-cooling of the proton bunches at an injection energy of 23:8 GeV. After pre-cooling, the proton bunches are accelerated to the maximum energy for collisions. Once at the top energy, such proton bunches can be refilled frequently to maintain a high average luminosity, or, alternatively, cooling at the top energy could be provided with relaxed requirements of just counteracting the emittance growth due to Intra-Beam Scattering (IBS) and thus maintaining the luminosity close to its initial peak value. Presently, several schemes of cooling at the top energy of 275 GeV are being considered with the goal to maintain the initial proton beam parameters, thus relying on pre-cooling at the low energy to obtain such initial parameters of proton bunches. For the lowest proton collision energy of 41 GeV in the EIC, there is a need for an electron cooler which counteracts the beam emittance growth due to IBS. This can be achieved by the same electron cooler which is used for cooling of protons at 23.8 GeV. In this case, we assume the electron cooler rst pre-cools protons at an injection energy of 23.8 GeV and then, after acceleration, cools the 41 GeV protons, counteracting IBS and maintaining the beam emittances. In this report, we summarize a feasibility study of an electron cooler that would be needed to cool protons at 23.8 GeV to obtain a small vertical emittance, as well as to counteract beam growth due to IBS for collisions at 41 GeV. The traditional electron cooling system employed at a typical low-energy cooler is based on an electron beam generated with an electrostatic electron gun in DC operating mode, immersed in a longitudinal magnetic field. To cool protons at 23.8 and 41 GeV, electron beam energies of 13.0 and 22.3MeV, respectively, are required. Due to the technical limitations of static high-voltage acceleration, these beam energies require RF acceleration of a pulsed electron beam. Electron cooling using RF-accelerated electron bunches was recently successfully commissioned in RHIC, allowing us to consider such an approach for EIC low-energy electron cooling.

43 PARTICLE ACCELERATORS↗