Search NASA⌕ Search

SEARCH · Search NASA

Results for “NOAA-20”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Uncertainties in CERES Top-of-Atmosphere Fluxes Caused by Changes in Accompanying Imager

The Clouds and the Earth’s Radiant Energy System (CERES) project provides observations of Earth’s radiation budget using measurements from CERES instruments on board the Terra, Aqua, Suomi National Polar-orbiting Partnership (S-NPP), and NOAA-20 satellites. The CERES top-of-atmosphere (TOA) fluxes are produced by converting radiance measurements using empirical angular distribution models, which are functions of cloud properties that are retrieved from imagers flying with the CERES instruments. As the objective is to create a long-term climate data record, not only calibration consistency of the six CERES instruments needs to be maintained for the entire time period, it is also important to maintain the consistency of other input data sets used to produce this climate data record. In this paper, we address aspects that could potentially affect the CERES TOA flux data quality. Discontinuities in imager calibration can affect cloud retrieval which can lead to erroneous flux trends. When imposing an artificial 0.6 per decade decreasing trend to cloud optical depth, which is similar to the trend difference between CERES Edition 2 and Edition 4 cloud retrievals, the decadal SW flux trend changed from −0.3 5 ± 0.18 Wm −2 to 0.61 ± 0.18 Wm −2 . This indicates that a 13% change in cloud optical depth results in about 1% change in the SW flux. Furthermore, different CERES instruments provide valid fluxes at different viewing zenith angle ranges, and including fluxes derived at the most oblique angels unique to S-NPP (>66 ∘ ) can lead to differences of 0.8 Wm −2 and 0.3 Wm −2 in global monthly mean instantaneous SW flux and LW flux. To ensure continuity, the viewing zenith angle ranges common to all CERES instruments (<66 ∘ ) are used to produce the long-term Earth’s radiation budget climate data record. The consistency of cloud properties retrieved from different imagers also needs to be maintained to ensure the TOA flux consistency.

Wenying Su↗

Short Time Scale Stability Monitoring of GOES-16 Visible Channels by Utilizing Daily Inter-Calibration Events with both VIIRS and MODIS Sensors

The CERES project relies on MODIS, VIIRS and geostationary (GEO) imager retrieved cloud properties to compute surface fluxes and convert CERES and GEO radiances into TOA fluxes. The CERES TOA and surface fluxes need to be of climate quality and any anomaly or discontinuity in the calibration of the MODIS, VIIRS, GEO radiances need to be mitigated or avoided. Due to the nature of the CERES instrument calibration, there is a lag time of 3 months before the processing of the CERES product. This allows the CERES team to investigate any unforeseen problems in the input datasets or GEO calibration discontinuities or anomalies before processing. The CERES geostationary imager calibration team is developing a daily monitoring system of GEO, MODIS and VIIRS visible channel radiances in order to detect any day to day discontinuities as part of the CERES/GEO coincident ray-matching calibration efforts. a GEO discontinuity can be detected using two MODIS and 2 VIIRS sensors simultaneously, thus increasing the sampling greatly over a single GEO/LEO radiance pairs. This method is being automated and has already detected three erroneous radiometric calibration events, which were verified with the GOES-16 event log page. One advantage of daily monitoring is that the time period needed to verify calibration drifts is reduced and the confidence to detect even smaller magnitudes of the calibration drift is increased over monthly monitoring. By utilizing Terra and Aqua MODIS and NPP and NOAA20 VIIRS imagers to inter-calibrate GOES-16, the GOES-16 calibration can be referenced to anyone of these imagers. If the CERES project transitions between the Aqua-MODIS imager to the NOAA20 VIIRS imager, the NOAA-20 VIIRS imager can be radiometrically scale to Aqua-MODIS calibration, thus avoiding a GOES-16 calibration discontinuity.

David Robert Doelling↗

CERES Fast Longwave And SHortwave Radiative Flux (FLASHFlux): Research to Operation

The Clouds and Earth’s Radiant Energy System (CERES) project provides satellite-based observations of how Earth’s energy flows are varying in time and space and how clouds and aerosols are affecting the Earth’s radiation budget. Nominally, CERES data products require months of validation and calibration before releasing a climate quality data. The Fast Longwave and Shortwave Radiative Flux (FLASHFlux) data product was developed as to provide key radiative flux data products within a week of observations for scientific, applied science research and educational usage. FLASHFlux achieves this by using simplified calibration process and optimized CERES data fusion production system, an operation meteorology product from Global Modeling and Assimilation Office(GMAO), and surface parameterized radiative flux models. The CERES FLASHFlux provides two data products: 1) an hourly Level 2 Single Scanner Footprint (SSF) data separately for Aqua and Terra observations, and 2) a daily Level 3 Time Interpolated and Spatially Averaged (TISA) 1ox1o gridded data that combines Aqua and Terra observations.The current operational Version 3C is being transitioned to Version4A. We compare the FLASHFlux Version4A fluxes using the specialized calibration to Version3C and to the climate quality CERES Edition4A TOA and surface fluxes over time for Terra and Aqua to determine the uncertainties of the calibration process. In addition, we also compare the impact of the fluxes by using the near real-time GMAO GEOS FP-IT instead of GMAO G5-CERES meteorology data.We also compare both SSF overpass products (for Terra and Aqua) and TISA radiative flux products to a set of surface measurement sites that are globally distributed and assess agreement.Lastly, we introduce the first CERES FF SSF data products from the CERES instrument on board NOAA-20.

P Sawaengphokhai↗

Application of quasi-deep convective clouds method for MODIS and VIIRS TEB calibration assessments

A technique to use deep convective clouds (DCC) and quasi-DCC (qDCC) for the calibration assessment of the thermal emissive bands (TEB) on remote sensing instruments has proven feasible. The Terra and Aqua MODIS and S-NPP and NOAA-20 VIIRS TEB calibration uses a nonlinear algorithm whose nonlinear coefficients rely on on-orbit black body (BB) warm-up and cool-down (WUCD) activities for updates. However, the limited BB temperature range affects the calibration’s uncertainty. The DCC core, one of the coldest Earth scenes, is suitable for MODIS calibration assessments; more specifically, for the evaluation of the offset effect in its TEB quadratic calibration function. Moreover, nighttime qDCC measurements provide the advantage of removing solar reflectance effects, thus enhancing the assessment’s accuracy for the midwave infrared TEB. In this paper, the qDCC method is applied to the Terra MODIS and VIIRS TEB. Their stabilities are assessed using long-term DCC and qDCC trending measurements over the instruments’ entire missions. The measurements from bands with an approximately 11-μm wavelength are used to identify the DCC pixels. MODIS band31 (~ 11m) has demonstrated stable performance and accurate calibration for both instruments throughout their respective missions. MODIS band31 can therefore be used as a reference for the other TEB. Furthermore, it also allows for a Terra and Aqua MODIS TEB cross-comparison. The assessment results, along with the calibration uncertainty and Level 1B product impact modeling, can be quite helpful for calibration improvements.

MODIS↗

SNPP and N20 VIIRS Solar Vector Orientation Knowledge Error Detected by SDSM Sun Views

The Visible Infrared Imaging Radiometer Suite (VIIRS) is a passive scanning Earth observing satellite radiometer. The VIIRS has 22 spectral bands with design center wavelengths from 0.41 to 12.01 μm, providing data to generate more than 20 Earth’s biogeophysical parameters. Fourteen of the 22 VIIRS bands are the reflective solar bands (RSBs), detecting Earth reflected sunlight. To ensure data quality, regular on-orbit radiometric calibrations of the RSBs are performed, mainly through observations of an onboard solar diffuser (SD). The spectral radiance provided by the sunlit SD depends on the SD screen transmittance which is a function of the solar vector orientation. Additionally, on orbit the SD’s bidirectional reflectance distribution function (BRDF) changes its value due to solar bombardment. The BRDF change is derived from the SD stability monitor (SDSM) measurements. The SDSM views the Sun through a screen with through holes (the SDSM screen) and the SD at almost the same time. The time series of the ratio of the signal strengths is a measure of the SD BRDF on-orbit change. Hence the measurements of the on-orbit SD BRDF change depends on the SDSM screen relative transmittance which is also solar vector orientation dependent. In this paper for both the SNPP and the NOAA-20 VIIRS instruments we examine the solar vector orientation knowledge error through matching the SDSM screen relative effective transmittances derived from the calibration data collected on the yaw maneuver and the regular orbits.

SNPP↗

New VIIRS DNB Stray Light Correction Method

The Day/Night Band (DNB) broadband (500-900nm) imager is one of the sensors in the Visible Infrared Imaging Radiometer Suite (VIIRS) on-board the Suomi National Polar-orbiting Partnership (SNPP) and the NOAA-20 satellites, which are polar-orbiting and fly at about 830km above the surface of the Earth. Depending on the satellite location and the sensor viewing geometry, for a short period just before (or after) the satellite enters into (or emerges from) the shadow of the Earth, unwanted stray light, seemingly caused by the reflection of solar beam on the slightly exposed inner side of the leading (or trailing) nadir door, can enter the instrument and impose noticeable impacts to a narrow portion of DNB satellite images in every orbit. The impacted images can be modified to look normal, and the current DNB stray light correction algorithm empirically assigns corrections. There is also an alternative approach using image-processing techniques. Both methods rely mainly on the stray light impacted measurements. To simplify the approach and for better correction results, the new method presented in this paper incorporates the observed asymptotic nature of measurements surrounding the stray light impacted region by fitting to the drop off in sun light from day to night. The new method can be applied to the raw measurements in real-time, and it can help to advance our understanding of this special type of DNB stray light that happens over the polar regions

VIIRS↗

The Dark Target aerosol retrieval algorithm applied to Low Earth Orbit and GEOstationary imagers: progress towards an integrated LEO-GEO view of global aerosol

The relatively simple dark-target (DT) aerosol retrieval algorithm provides products of spectral aerosol optical depth (AOD) from measurements of multi-spectral reflectance in visible, near-infrared and shortwave infrared wavelength bands. Originally developed for Moderate-resolution Imaging Spectroradiometer (MODIS aboard Terra and Aqua) in Low-Earth Orbit (LEO), DT has been ported to Visible Infrared Imaging Suite (VIIRS aboard Suomi-NPP and NOAA-20, also in LEO), to enhanced-MODIS Airborne Simulator (eMAS, on an airborne platform), and now to sensors in GEOstationary orbit (Advanced Himawari Imager - AHI aboard Himawari-8 and Advanced Baseline Imagers – ABI aboard GOES-16 and 17). Together, these new datasets not only extend upon the 20+ year MODIS aerosol record, but also expand the temporal sampling and/or spatial resolution. Between July and October of 2019, NASA participated in two field experiments on opposite sides of the globe. These included FIREX-AQ which focused on fire and smoke in the Western U.S., and then CAMP2EX which targeted aerosol/cloud interactions around the Philippines. We have performed DT aerosol retrievals on all images from all sensors during these three months, validated against ground observations from stationary and mobile sunphotometer sites, and have begun to develop a synergy that represents semi-global observations every half hour. The resulting aerosol products are being used as context and for model assimilation, thus providing the framework for more complete characterization of global aerosol transport and lifecycle. Here, we report on progress, as well as remaining challenges such as data management, computer processing, and accounting for differences between GEO and LEO observation geometry and surface reflectance parameterization.

dark target↗

JPSS-1 ATMS Post-launch Active Geolocation Analysis

A NOAA-20 (N20) ATMS active geolocation test was performed around Jan. 2018 with 24 pre-selected coastline crossing scenes. After comprehensive analysis of ATMS stare data and the corresponding VIIRS data, the ATMS pitch, roll and yaw pointing angle errors are found from the nadir perpendicular, the nadir oblique shallow angle, and the off-nadir perpendicular coastline crossing data, respectively. In this study, we first determine the ATMS radiometric coastline crossing time by using the ATMS radiometric count data. Since the coastline can be located anywhere within one ATMS FOV from the passive (regular scanning) geolocation data, depending on the scan starting time, it is not a valid assumption for the inflection point being the same as the coastline location. Consequently, using the passive geolocation data to validate the sensor’s on-orbit pointing angle performance is limited. After finding the ATMS radiometric coastline crossing time from the ATMS data, we compare it with the VIIRS effective time stamp (see main text). Specifically the VIIRS M3, M4 & M5 (true color) & M15 and M16 bands (thermal) data have a much smaller footprint size. Using the differences of the ATMS and VIIRS (effective) coastlines crossing times, the N20 ATMS pitch, roll and yaw pointing angle errors are found to be -0.09o, -0.24o and 0.28o, respectively. To determine ATMS geolocation properly, these on-orbit pointing errors need to be corrected, adding to the ATMS SDR Processing Coefficient Table, and passed on to the operational geolocation processing code.

Active Geolocation↗

JPSS-2 VIIRS Version 1 spectral characterization and performance assessment

The JPSS-2 VIIRS instrument is set to be the third VIIRS instrument when it launches in 2022 following S-NPP and NOAA-20 VIIRS which launched in October 2011and November 2017, respectively. To date JPSS-2 VIIRS has undergone extensive pre-launch testing at the instrument system level to determine the radiometric, spatial, and spectral performance. Spectral testing was conducted by the instrument vendor, Raytheon Corporation, at their test facility in mid-to-late 2017 with a test configuration that utilized a double monochrometer with illumination provided by tungsten lamp and ceramic glow bar to cover the full spectral range. The purpose of these measurements was to measure the relative spectral response curve and assess the spectral characteristics necessary to determine compliance with the sensor design requirements. In addition to Raytheon team, the spectral measurements were analyzed by an independent government team with members from NASA, the University of Wisconsin, and Aerospace Corporation. Two RSR curves were released by the government team from this data set: a version 0 release which was the verified RSR as calculated by Raytheon, and version 1 which was the RSR assessment from the government team. The results discussed here are those of the government team (version 1) including the independent assessment of sensor compliance and a comparison of the JPSS-2 VIIRS spectral characteristics with the two previous VIIRS instruments. The version 1 RSR was publicly released to the science community in the fall of 2018, and remains available for their use.

VIIRS↗

Modeling Spectral Degradation of MODIS and VIIRS Solar Diffusers

Solar diffusers (SDs) onboard the Moderate Resolution Imaging Spectroradiometer (MODIS) on Terra and Aqua spacecraft and the Visible Infrared Imaging Radiometer Suite (VIIRS) on SNPP and NOAA-20 spacecraft have been used as the primary onboard radiometric calibrator for reflective solar bands and their spectral reflectance is known to degrade on-orbit. All of the solar diffusers on these instrument show faster degradation of reflectance in the 0.4 to 0.6 µm channels than the longer wavelength channels. The spectral degradation of these SDs is due to the surface roughness growth under the exposure to solar UV and energetic particle radiation in space. In this paper, the origin of SD degradation is modeled by the physics-based Surface Roughness-induced Rayleigh Scattering (SRRS) model. The longterm growths of surface roughness of the SD on these instruments are characterized to show the consistency of SD roughness growth rates between Terra/Aqua MODIS and SNPP/NOAA-20 VIIRS. There was coincidental flattening or reverse in the growth trend of the surface roughness for the Terra/Aqua MODIS and SNPP VIIRS SDs, which can be due to the space weather variation. The applicability of the SRRS model is demonstrated with the long term spectral reflectance data from independent spaceborne SDs.

Calibration↗

MODIS and VIIRS Calibration History and Future Outlook

The MODIS is a key instrument for NASA’s EOS program, currently operated onboard the Terra and Aqua spacecraft launched in 1999 and 2002, respectively. The VIIRS is a MODIS follow-on instrument for the JPSS program. Adding to the ones operated onboard the S-NPP and NOAA-20 satellites launched in 2011 and 2017, respectively, three nearly identical VIIRS instruments will also be launched. This will enable the data records from MODIS and VIIRS to be extended beyond 2040. In addition to various applications and scientific studies of the Earth’s system, long-term data records from MODIS and VIIRS observations will greatly benefit the space-based climate observing system. This is attributed to the high-quality measurements and extensive calibration efforts, from pre-launch to post-launch. This paper provides an overview of MODIS and VIIRS calibration history and approaches applied to establish and maintain sensor calibration traceability and accuracy. It illustrates calibration and performance issues through different phases of the mission using examples derived from ground testing equipment, on-board calibrators, and other calibration targets. Moreover, discussed in this paper are outstanding challenges and future efforts to maintain and improve sensor calibration stability and long-term data quality, and to better support the space-based climate observing system.

MODIS↗

Using solar eclipse events to validate VIIRS reflective solar band calibration at multiple radiance levels

The VIIRS instruments aboard the SNPP and NOAA-20 (N20) satellites have 14 reflective solar bands (RSB) covering a spectral range from 412 nm to 2250 nm. The radiance of each VIIRS RSB is calculated from a quadratic function of the background-subtracted digital count, 𝑑𝑛, with the quadratic coefficients determined during pre-launch testing. On orbit, calibration is maintained using observations of a sunlit solar diffuser (SD), which views the Sun every orbit through a fixed attenuation screen. The SD observations, which are at nearly the same radiance level every orbit, provide a time varying overall calibration adjustment factor, the F-factor. But there is no designed on-orbit mechanism for calibration at multiple radiance levels, so the relative strengths of the quadratic coefficients continue to be fixed at the pre-launch values. On a few rare occasions, the VIIRS instruments have passed through a partial solar eclipse during the part of the satellite orbit when the SD is illuminated by the Sun (near the South Pole). As of August 2019, the SNPP and N20 VIIRS SDs have observed five and three partial solar eclipses, respectively. While these events are rare, they offer a unique opportunity to test the RSB calibration using the SD at different radiance levels. In this paper, we compare the reduction in the measured SD signals during an eclipse to the predicted radiance reduction based on the Sun-Moon geometry and a solar radiance model. We find good agreement between the data and model for all events, indicating that the VIIRS RSB gain linearity has remained fairly stable on-orbit. The most significant deviation is for the N20 short-wave infrared bands, which had non-linearity concerns during pre-launch testing. We also investigate the SNPP results using different versions of the prelaunch quadratic gain coefficients.

solar eclipse↗

Validation of Carbon Trace Gas Profile Retrievals from the NOAA-Unique Combined Atmospheric Processing System for the Cross-Track Infrared Sounder

This paper provides an overview of the validation of National Oceanic and Atmospheric Administration (NOAA) operational retrievals of atmospheric carbon trace gas profiles, specifically carbon monoxide (CO), methane (CH4) and carbon dioxide (CO2), from the NOAA-Unique Combined Atmospheric Processing System (NUCAPS), a NOAA enterprise algorithm that retrieves atmospheric profile environmental data records (EDRs) under global non-precipitating (clear to partly cloudy) conditions. Vertical information about atmospheric trace gases is obtained from the Cross-track Infrared Sounder (CrIS), an infrared Fourier transform spectrometer that measures high resolution Earth radiance spectra from NOAA operational low earth orbit (LEO) satellites, including the Suomi National Polar-orbiting Partnership (SNPP) and follow-on Joint Polar Satellite System (JPSS) series beginning with NOAA-20. The NUCAPS CO, CH4, and CO2 profile EDRs are rigorously validated in this paper using well-established independent truth datasets, namely total column data from ground-based Total Carbon Column Observing Network (TCCON) sites, and in situ vertical profile data obtained from aircraft and balloon platforms via the NASA Atmospheric Tomography (ATom) mission and NOAA AirCore sampler, respectively. Statistical analyses using these datasets demonstrate that the NUCAPS carbon gas profile EDRs generally meet JPSS Level 1 global performance requirements, with the absolute accuracy and precision of CO 5% and 15%, respectively, in layers where CrIS has vertical sensitivity; CH4 and CO2 product accuracies are both found to be within ±1%, with precisions of ≈1.5% and ⪅0.5%, respectively, throughout the tropospheric column.

satellite cal/val; error analysis; greenhouse gase↗

Application of Quasi-Deep Convective Clouds Method for VIIRS and MODIS TEB Calibration Assessments

A technique that utilizes quasi-deep convective clouds (qDCC) for the calibration assessment of the thermal emissive bands (TEB) on remote sensing instruments has been proven viable. The Terra and Aqua MODIS and S-NPP and NOAA-20 VIIRS TEB calibration uses a nonlinear algorithm whose nonlinear coefficients rely on on-orbit blackbody (BB) warm-up and cooldown operations for updates. However, a limited BB temperature range affects the calibration’s accuracy particularly for cold scenes. The deep convective clouds (DCC) core, one of the coldest Earth scenes, is suitable for MODIS calibration assessments; more specifically, for the evaluation of the offset term’s effect in its TEB quadratic calibration function. Moreover, nighttime qDCC measurements provide with the advantage of removing solar reflectance effects during daytime, thus enhancing the assessment’s accuracy for the midwave infrared TEB. In this paper, this qDCC method is applied to the Terra MODIS and VIIRS TEB; and their stabilities are assessed using long-term qDCC trending measurements over the instruments’ missions. The measurements from bands with an 11-μm wavelength are used to identify the DCC pixels. The 11-μm bands, MODIS band 31 and VIIRS bands M15 and I5, are stable throughout the MODIS and VIIRS missions and have shown excellent calibration accuracy and noise performance. Hence, using these bands as references, a normalization method is employed to enhance the accuracy of the stability and consistency assessments. The S-NPP VIIRS TEB show stable trends over the instrument’s mission. The S-NPP-to-N20 VIIRS comparison shows their TEB measurements are consistent over qDCC. The Terra MODIS TEB also show stable performance – except for bands 27, 29, and 30. Terra MODIS band 30 shows a large downward trend throughout the mission, while bands 27 and 29 show slight, upward drifts. Lastly, a calibration correction using qDCC assessments is discussed and intended to be used in a future calibration algorithm collection.

MODIS↗

Unscheduled Lunar Observations for Radiometric Characterization of VIIRS Reflective Solar Bands

Regularly scheduled lunar observations are a major component of the on-orbit calibration of the Suomi National Polar-Orbiting Partnership (SNPP) Visible Infrared Imaging Radiometer Suite (VIIRS) reflective solar bands (RSB). With a few exceptions, these scheduled lunar observations have been performed with the same phase angles ranging from -51.5° to -50.5°. In addition to these observations that require a roll maneuver, the VIIRS instruments also view the Moon via its space-view port without a roll maneuver, covering a wide range of phase angles. In this paper, we present techniques used to derive the radiometric gain for the VIIRS RSB using unscheduled lunar observations that are made over a range of phase angles. An empirical correction to account for residual phase angle dependencies is derived from on-orbit SNPP VIIRS unscheduled lunar events and is successfully applied to estimate the radiometric gain that shows good agreement with the gains derived from the scheduled lunar events as well as those derived from the solar diffuser. In addition to the follow-on VIIRS instrument on the NOAA-20 satellite, three more VIIRS instruments are scheduled to be launched in the next decade. The methodologies developed in this work are expected to be applied to unscheduled lunar events from other VIIRS instruments to support their on-orbit RSB calibration.

VIIRS↗

Performance Assessments of the SNPP and N20 VIIRS DNB Using Observations of Bright Stars

The Visible Infrared Imaging Radiometer Suite (VIIRS) on-board the Suomi-NPP (SNPP) and NOAA-20 (N20) spacecrafts is a multi-spectral Earth-observing instrument with spectral channels ranging from the visible to the long-wave infrared. In addition to these spectral channels, the VIIRS instrument features a panchromatic Day/Night band (DNB) with 3 gain stages (low, mid, and high) which allows for Earth-view (EV) radiance retrievals over 7 orders of magnitude. The DNB is able to collect data ranging from dim city lights during nighttime up to reflected sunlight from cloud-tops during daytime. The DNB data collection is divided into 32 aggregation modes, where sub-pixel aggregation is used to maintain a nearly constant pixel footprint on ground during EV data collection throughout each scan. The DNB is also sensitive enough to observe bright stars through the instrument space-view (SV) port. Data from these bright stars can be used to track the temporal stability of the sensor gain and as a method of intercomparison between the two VIIRS instruments. In this work, we will present several sensor performance assessments of the VIIRS DNB using stars. In addition to the sensor gain trending, these assessments will include a comparison of the differences between the daytime and nighttime data due to the effects of stray-light, a comparison of the measured signal as a function of aggregation mode, a comparison between the two high-gain sub-stages, and half-angle mirror side for both the SNPP and N20 VIIRS DNB.

VIIRS↗

On-Orbit Calibration Assessment of NOAA-21 VIIRS Thermal Emissive Bands and Implications for JPSS-4 VIIRS

The Visible Infrared Imaging Radiometer Suite (VIIRS) instrument onboard the NOAA-21 (N21) satellite has been successfully operating for over three years collecting valuable scientific measurements. A large suite of weather forecasting models and scientific research applications are supported with the VIIRS measurements from N21 combined with those acquired from the VIIRS instrument onboard the S-NPP and NOAA-20 spacecraft. Among the 22 VIIRS spectral bands, there are seven thermal emissive bands (TEB) covering the 3.7 to 12.2 µm spectral range at two different spatial resolutions. The VIIRS TEB detectors are calibrated onboard using a blackbody at a controlled temperature and a space view for background signal measurement. In this paper, we discuss the on-orbit performance of the N21 VIIRS TEB using various parameters such as the detector gain, noise, and offset. This on-orbit assessment provides critical insights into instrument behavior and calibration performance that will inform pre-launch testing and post-launch validation strategies for the upcoming JPSS-4 VIIRS mission scheduled for launch in 2027. The methodologies and lessons learned from characterizing the N21 TEB performance will enable more efficient and comprehensive radiometric assessment of the next VIIRS instrument. Specific focus is placed on identifying performance trends and anomaly signatures observed during the N21 commissioning phase that can enhance the JPSS4 instrument checkout procedures and accelerate the transition to routine on-orbit operations. The established performance baselines and uncertainty estimates will serve as an acceptance criterion for the JPSS-4 commissioning activities, ensuring mission readiness and data continuity for operational users.

Amit Angal↗

PRELIMINARY JPSS-3 VIIRS POLARIZATION SENSITIVITY AND COMPARISON WITH S-NPP, JPSS-1 AND -2

The Visible-Infrared Imaging Radiometer Suite (VIIRS) was first launched on-board the Suomi National Polar-orbiting Partnership (S-NPP) spacecraft in October of 2011. There have been three subsequent builds of the VIIRS sensor for the Joint Polar Satellite System (JPSS) program with JPSS-1, -2 and -3 having launch dates of November 2017, March 2022 and 2026 respectively. There is also a JPSS-4 VIIRS, that is in hardware integration during 2020, with a launch date of 2031. VIIRS has 22 bands: 7 thermal emissive bands (TEBs), 14 reflective solar bands (RSBs) and a Day Night Band (DNB). Ocean Color/Chlorophyll (OCC) products use calibrated Science Data Records (SDRs) for bands M1-M7(0.412-0.865μm) to compute their ocean chemistry products. These bands require accurate polarization sensitivity characterization to compensate for polarized upwelling Rayleigh scatter and produce accurate OCC Environment Data Products (EDRs). VIIRS polarization sensitivity requirement failures have driven hardware modifications to the bandpass filters and dichroic beam splitter over the program. This paper will discuss the preliminary JPSS-3 polarization results and how these hardware modifications, as the JPSS program progresses, have affected the sensor performance. Comparisons of the polarization sensitivities between sensor builds will be discussed along with the hardware modifications that contributed to their differences.

VIIRS↗