Search NASA⌕ Search

SEARCH · Search NASA

Results for “NOISE REDUCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A three-dimensional laser ray-tracing methodology for radiation-hydrodynamics simulations

We report on a methodology for performing laser ray-tracing in three spatial dimensions for radiation-hydrodynamics simulation codes. Our method, which is an extension of that developed in Haines et al., Comput. Fluids 201, 104478 (2020), utilizes an automatically generated separate mesh for the laser ray-tracing from the radiation-hydrodynamics mesh. This enables the laser mesh to be tailored to minimize ray noise with significantly fewer rays than would be required when the ray-tracing is performed on the radiation-hydrodynamics mesh, primarily by allowing the use of high-aspect-ratio cells that are not suitable for hydrodynamics solvers. For a planar target, we show that our method provides a ≈ 100× reduction in computational expense to achieve a fixed level of ray noise relative to ray-tracing directly on the radiation-hydrodynamics mesh. The relatively low ray requirement also enables efficient computation of cross-beam energy transfer. Each cell in the logically cubic laser mesh is a non-convex dodecahedron with triangular sides, and numerical integration of the ray trajectories and inverse bremsstrahlung is performed by mapping each cell to the unit cube. We will describe our methodology in detail as well as its implementation in the xRAGE radiation-hydrodynamics code, discuss performance, and present the results from applying the methodology to test problems with analytic solutions for laser ray-tracing through a quadratic density gradient with an analytic solution as well as for a laser-driven heat front. In 3D radiation-hydrodynamics simulations of laser-driven experiments performed on the National Ignition Facility, laser ray-tracing with our methodology uses less than 1% of total computational time while introducing acceptably low levels of ray noise.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of foreground moment deprojection for semi-blind CMB polarization reconstruction

Abstract Upcoming Cosmic Microwave Background (CMB) experiments, aimed at measuring primordial CMB polarization B-modes, require exquisite control of instrumental systematics and Galactic foreground contamination. Blind minimum-variance techniques, like the Needlet Internal Linear Combination (NILC), have proven effective in reconstructing the CMB polarization signal and mitigating foregrounds and systematics across diverse sky models without suffering from foreground mismodelling errors. Still, residual foreground contamination from NILC may bias the recovered CMB polarization at large angular scales when confronted with the most complex foreground scenarios.By adding constraints to NILC to deproject statistical moments of the Galactic emission, the Constrained Moment ILC (cMILC) method has been demonstrated to further enhance foreground subtraction, albeit with an associated increase in overall noise variance. Faced with this trade-off between foreground bias reduction and overall variance minimization, there is still no recipe on which moments to deproject and which are better suited for blind variance minimization. To address this, we introduce the optimized cMILC (ocMILC) pipeline, which performs full automated optimization of the required number and set of foreground moments to deproject, pivot parameter values, and deprojection coefficients across the sky and angular scales, depending on the actual sky complexity, available frequency coverage, and experiment sensitivity. The optimal number of moments for deprojection, before paying significant noise penalty, is determined through a data diagnosis inspired by the Generalized NILC (GNILC) method.Validated on B-mode simulations of thePICOspace mission concept with four challenging foreground models, ocMILC exhibits lower Galactic foreground contamination compared to NILC and cMILC at all angular scales, with limited noise penalty. This multi-layer optimization enables the ocMILC pipeline to achieve unbiased posteriors of the tensor-to-scalar ratio, regardless of foreground complexity.

Astronomy & Astrophysics↗

Big Data Meets Geothermal Exploration (CRADA Final Report)

As part of the Cyclotron Road program, Zanskar Geothermal & Minerals, Inc. investigated the application of micro-earthquake and ambient noise seismology methods to imaging and characterizing the structural characteristics and hydrothermal flux of subsurface faults. Significant advances in what could be resolved were enabled by two major developments in seismology: 1) the availability of large-n arrays of low-cost seismometers, and 2) the availability of increased computational power and semi-automated data reduction algorithms. In tandem, these advances may improve the signal-to-noise ratio and spatial precision of the data collected and enable higher-resolution characterization of subsurface fracture systems and their spatio-temporal evolution. These tools supported efforts to reduce dry-hole risk and to improve wellfield productivity for geothermal resource development. In particular, two applications of these advances were evaluated: 1) fracture-seismic imaging, which was used to detect ambient emissions from fluid-filled fractures, and 2) reservoir tomography, which used information about travel paths, source locations, and source parameters of micro-earthquakes to identify areas of enhanced permeability. Integration of these methods provided guidance for siting wells and served as prior constraints for reservoir models, informing forecasts of power potential and production and injection strategies aimed at minimizing temperature decline and improving overall resource productivity.

15 GEOTHERMAL ENERGY↗

Identifying Vehicle Signals in Continuous Seismic Data Using Unsupervised Machine-Learning Techniques

Seismic sensors deployed near roadways effectively capture ground vibrations generated by passing vehicles. Although both traditional and machine‐learning algorithms have been utilized for analyzing such signals, independent validation of detected vehicle events remains limited. We applied two unsupervised machine‐learning algorithms, uniform manifold approximation and projection for dimension reduction, and hierarchical density‐based spatial clustering of applications with noise, to continuous seismic data collected along a road on the main campus of Oak Ridge National Laboratory. The algorithms identified seven distinct cluster labels across the entire dataset. By comparing these cluster labels with precipitation records from a nearby weather station and image‐derived labels from a local camera system, we identified one cluster associated with rainfall and another with vehicle activity. Our algorithms identified a greater number of vehicle‐related labels compared to the camera‐derived labels because seismic data are unaffected by poor lighting conditions. The arrival times of the newly detected vehicle signals corresponded well with the road’s speed limit, supporting our findings. Our algorithm outperformed the short‐term average/long‐term average method and k‐means clustering. Our results suggest that seismic data, when analyzed with machine‐learning algorithms, can complement existing vehicle monitoring systems, particularly under challenging environmental conditions.

Chai, Chengping [Oak Ridge National Laboratory (OR↗

Personalized and uncertainty-aware coronary hemodynamics simulations: From Bayesian estimation to improved multi-fidelity uncertainty quantification

Non-invasive simulations of coronary hemodynamics have improved clinical risk stratification and treatment outcomes for coronary artery disease, compared to relying on anatomical imaging alone. However, simulations typically use empirical approaches to distribute total coronary flow amongst the arteries in the coronary tree, which ignores patient variability, the presence of disease, and other clinical factors. Further, uncertainty in the clinical data often remains unaccounted for in the modeling pipeline. We present an end-to-end uncertainty-aware pipeline to (1) personalize coronary flow simulations by incorporating vessel-specific coronary flows as well as cardiac function; and (2) predict clinical and biomechanical quantities of interest with improved precision, while accounting for uncertainty in the clinical data. We assimilate patient-specific measurements of myocardial blood flow from clinical CT myocardial perfusion imaging to estimate branch-specific coronary artery flows. Simulated noise in the clinical data is used to estimate the joint posterior distributions of the model parameters using adaptive Markov Chain Monte Carlo sampling. Additionally, the posterior predictive distribution for the relevant quantities of interest is determined using a new approach combining multi-fidelity Monte Carlo estimation with non-linear, data-driven dimensionality reduction. This leads to improved correlations between high- and low-fidelity model outputs. Our framework accurately recapitulates clinically measured cardiac function as well as branch-specific coronary flows under measurement noise uncertainty. We observe substantial reductions in confidence intervals for estimated quantities of interest compared to single-fidelity Monte Carlo estimation and state-of-the-art multi-fidelity Monte Carlo methods. This holds especially true for quantities of interest that showed limited correlation between the low- and high-fidelity model predictions. In addition, the proposed multi-fidelity Monte Carlo estimators are significantly cheaper to compute than traditional estimators, under a specified confidence level or variance. The proposed pipeline for personalized and uncertainty-aware predictions of coronary hemodynamics is based on routine clinical measurements and recently developed techniques for CT myocardial perfusion imaging. The proposed pipeline offers significant improvements in precision and reduction in computational cost.

Bayesian parameter estimation↗

Robustness of the smartpixels classifier for different simulated sensor geometries and non-ideal detector conditions

Pixel tracking detectors at upcoming collider experiments will see unprecedented charged-particle densities. Real-time data reduction on the detector will enable higher granularity and faster readout, possibly enabling the use of the pixel detector in high-rate online event selection, such as the ATLAS or CMS first-level trigger systems. This data reduction can be accomplished with a neural network (NN) in the readout chip bonded with the sensor that recognizes and rejects tracks with low transverse momentum (p T ) based on the geometrical shape of the charge deposition (“cluster”). To design viable detectors for deployment, the dependence of the NN as a function of the sensor geometry, external magnetic field, irradiation, and noise must be understood. In this paper, we present first studies of the efficiency and data reduction for planar pixel sensors exploring these parameters. For the CMS HL-LHC sensor geometry, we obtain a signal efficiency of (91.9 ± 0.7)% and a data reduction of (29.7 ± 1.0)%. A smaller sensor pitch in the bending direction improves the p T discrimination, but a larger pitch can be partially compensated with detector thickness. Any accumulated radiation damage also changes the cluster shape, reducing the signal efficiency compared to the baseline by approximately 30–60% in absolute terms, but nearly all of the performance can be recovered through retraining of the network and updating the weights. Finally, the impact of noise was investigated, and retraining the network on noise-injected datasets was found to maintain performance within 6% of the baseline network trained and evaluated on noiseless data. •ASIC-compatible track-momentum classifier is robust in realistic detector conditions.•About 90% signal efficiency and 30% data reduction per layer for CMS HL-LHC geometry.•Single-layer signal efficiency increases for smaller pixel pitch or thicker sensors.•Performance with noise or after radiation damage mostly recovered by retraining.

Shekar, Danush [Illinois U., Chicago] (ORCID:00000↗

Topology-Dependent Performance of Free-Space Photonic Quantum Networks Under Noise

Photonic quantum communication enables secure and high-fidelity information transfer beyond classical limits, with direct relevance to emerging quantum networks operating in free-space environments. While physical-layer models of depolarizing noise, Gamma–Gamma turbulence statistics, entanglement swapping, and decoy-state QKD security bounds are individually well established, prior work typically treats these components in isolation or under fixed network assumptions. In this work, we develop a unified topology-aware analytical framework that simultaneously integrates free-space optical link budgets, turbulence-induced visibility degradation, depolarizing qubit noise, multi-hop entanglement cascade dynamics, teleportation fidelity thresholds, CHSH nonlocality certification, and asymptotic decoy-state secret key rate bounds across star, mesh, and ring graph structures. Rather than introducing new physical channel models, we demonstrate that identical physical links exhibit fundamentally different end-to-end performance once embedded within different network topologies. Mesh architectures minimize visibility cascade through hop-count reduction but incur quadratic hardware scaling. Star topologies minimize link count but concentrate noise and synchronization overhead at the hub. Ring configurations offer linear hardware scaling with multiplicative fidelity degradation. The results establish topology as a first-order design parameter in near-term free-space quantum networks operating without full quantum repeater infrastructures. While motivated by distributed multi-agent architectures, the framework applies broadly to terrestrial, airborne, and satellite-assisted photonic quantum communication systems.

QKD↗

Simulation study for particle identification with the dRICH of the ePIC experiment at the EIC

The dual-radiator Imaging Cherenkov detector (dRICH), employing an aerogel and a gas radiator, is a key component of the forward particle identification system for the ePIC experiment at the Electron-Ion Collider (EIC). This study evaluates the dRICH performance using Geant4 simulations in the context of the global ePIC simulation stack, focusing on the optimization of the aerogel radiator and the impact of sensor noise. We compare two aerogel configurations: the initial design (n = 1.019) and the current default (n = 1.026). The latter, characterized by improved optical properties and a higher refractive index, demonstrates enhanced π/K separation at high momenta, effectively extending the operational overlap with the C 2 F 6 gas radiator (n = 1.00076 at 25 °C, as implemented in the simulation software). Additionally, the study investigates the impact of Silicon Photomultiplier (SiPM) dark noise, showing that a 300 kHz noise rate per 3mm x 3mm channel leads to a moderate reduction (approximately 1.5 GeV/c) in the 3σ separation threshold. These results validate the current dRICH design and quantify the purity levels achievable for both radiators under expected experimental conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Estimating Eigenenergies from Quantum Dynamics: A Unified Noise-Resilient Measurement-Driven Approach

Ground state energy estimation in physical, chemical, and materials sciences is one of the most promising applications of quantum computing. In this work, we introduce a new hybrid approach that finds the eigenenergies by collecting real-time measurements and post-processing them using the machinery of dynamic mode decomposition (DMD). From the perspective of quantum dynamics, we establish that our approach can be formally understood as a stable variational method on the function space of observables available from a quantum many-body system. We also provide strong theoretical and numerical evidence that our method converges rapidly even in the presence of a large degree of perturbative noise, and show that the method bears an isomorphism to robust matrix factorization methods developed independently across various scientific communities. Our numerical benchmarks on spin and molecular systems demonstrate an accelerated convergence and a favorable resource reduction over state-of-the-art algorithms. The DMD-centric strategy can systematically mitigate noise and stands out as a leading hybrid quantum-classical eigensolver.

Shen, Yizhi↗

Performance of an X-γ ray detection system based on a thick silicon LGAD

We present the performance of a X-γ ray detection systems based on a 300 µm thick silicon low-gain avalanche diode (LGAD) and of an equivalent Diode structure without the gain layer, read-out by a custom-made low-noise charge amplifier. For the LGAD structure, the multiplication gains M s from 10.2 to 19.3 are measured, and the Equivalent Noise Charge (ENC) components have been studied in detail. As expected, a significant reduction of the white and 1/f voltage series and dielectric ENC components is observed with increasing gain, shortening the optimum peaking time to τ = 0.4÷8 μs depending on the gain value, with respect to the standard diode, while the parallel ENC component increases proportionally to the gain up to M s = 15. Setting the gain M s = 12.7, a minimum ENC = 34.5 electrons r.m.s. (298 eV FWHM) at τ = 1 μs is found. However, the electronic noise, evaluated on the pulser FWHM, is found to only marginally contribute to the width of the spectral lines of a radioactive source, which are dominated instead by the statistical noise of the charge multiplication within the LGAD structure. The spectral lines' excess width is found to be proportional to the signal multiplication gain M s and increases with the energy of the photons. A minimum line width of 850 eV FWHM at 13.9 keV is measured at room temperature, τ = 2 μs and a gain M s = 10.2.

47 OTHER INSTRUMENTATION↗

Gate-Tunable Short-Wave Infrared Polycrystalline GeSn Phototransistors on Noncrystalline Substrates

GeSn is a group-IV alloy with immense potential to advance microelectronics technology due to its intrinsic compatibility with existing Si CMOS processes. With a sufficiently high Sn composition, GeSn is classified as a direct bandgap semiconductor. Polycrystalline GeSn holds several additional advantages, including its significantly lower synthesis cost compared to its epitaxial counterpart, as well as the versatility to grow these films on a variety of substrates. Here, in this work, we present a polycrystalline thin-film GeSn phototransistor on a fused silica substrate with a Sn composition of ~10%, showing a photoresponse in the short-wave infrared wavelength range, critical for emerging sensing applications. This device shows a gate-tunable response, with responsivities approaching up to 1.7 mA/W with only a 30 nm-thick GeSn layer. Furthermore, phototransistors offer additional adaptability through gating, which allows for the reduction of dark current. This not only enhances the signal-to-noise ratio but also offers more flexible integration with various image sensor readout implementations using different substrates. The specific detectivity of this phototransistor is within an order of magnitude of those of previously reported GeSn photodetectors grown by molecular beam epitaxy and chemical vapor deposition, even though the absorber is 3 to 20× thinner while the electrode spacing for photocarrier transport is approximately 15× longer than the carrier diffusion length in this work, showing great potential benefits of extending similar device structures to epitaxial GeSn layers. As these GeSn phototransistors utilize a noncrystalline substrate, our work establishes a fundamentally more versatile path toward monolithically integrated GeSn-based photodetectors for next-generation multimodal sensors.

36 MATERIALS SCIENCE↗

A quantum eigenvalue solver based on tensor networks

Electronic ground states are of central importance in chemical simulations, but have remained beyond the reach of efficient classical algorithms except in cases of weak electron correlation or one-dimensional spatial geometry. We introduce a hybrid quantum-classical eigenvalue solver that constructs a wavefunction ansatz from a linear combination of matrix product states in rotated orbital bases, enabling the characterization of strongly correlated ground states with arbitrary spatial geometry. The energy is converged via a gradient-free generalized sweep algorithm based on quantum subspace diagonalization, with a potentially exponential speedup in the off-diagonal matrix element contractions upon translation into compact quantum circuits of linear depth in the number of qubits. Chemical accuracy is attained in numerical experiments for both a stretched water molecule and an octahedral arrangement of hydrogen atoms, achieving substantially better correlation energies compared to a unitary coupled-cluster benchmark, with orders of magnitude reductions in quantum resource estimates and a surprisingly high tolerance to shot noise. This proof-of-concept study suggests a promising new avenue for scaling up simulations of strongly correlated chemical systems on near-term quantum hardware.

chemistry↗

Jensen–Shannon divergence based novel loss functions for Bayesian neural networks

Bayesian neural networks (BNNs) are state-of-the-art machine learning methods that can naturally regularize and systematically quantify uncertainties using their stochastic parameters. Kullback–Leibler (KL) divergence-based variational inference used in BNNs suffer from unstable optimization and challenges in approximating light-tailed posteriors due to the unbounded nature of the KL divergence. To resolve these issues, we formulate a novel loss function for BNNs based on a new modification to the generalized Jensen–Shannon (JS) divergence, which is bounded. In addition, we propose a Geometric JS divergence-based loss, which is computationally efficient since it can be evaluated analytically. We found that the JS divergence-based variational inference is intractable, and hence employed a constrained optimization framework to formulate these losses. Our theoretical analysis and empirical experiments on multiple regression and classification data sets suggest that the proposed losses perform better than the KL divergence-based loss, especially when the data sets are noisy or biased. Specifically, there are approximately 5% and 8% improvements in accuracy for a noise-added CIFAR-10 dataset and a regression dataset, respectively. There is about 13% reduction in false negative predictions of a biased histopathology dataset. Additionally, we quantify and compare the uncertainty metrics for the regression and classification tasks.

97 MATHEMATICS AND COMPUTING↗

Adaptive Client Selection in Federated Learning: A Network Anomaly Detection Use Case

Federated Learning (FL) has become a ubiquitous approach for training machine learning models on decentralized data, addressing the myriad privacy concerns inherent in traditional centralized methods. However, the efficiency of FL depends on effective client selection and robust privacy preservation mechanisms. Inadequate client selection may lead to suboptimal model performance, while insufficient privacy measures risk exposing sensitive data. This paper proposes a client selection framework for FL that integrates differential privacy and fault tolerance. Our adaptive approach dynamically adjusts the number of selected clients based on model performance and system constraints, ensuring privacy through calibrated noise addition. We evaluate our method on a network anomaly detection use case using the UNSW-NB15 and ROAD datasets. Results show up to a 7% increase in accuracy and a 25% reduction in training time compared to FedL2P. Moreover, we highlight the trade-offs between privacy budgets and model performance, with higher privacy budgets reducing noise and improving accuracy. Our fault tolerance mechanism, while causing a slight performance drop, enhances robustness to client failures. Statistical validation using Mann-Whitney U tests confirms the significance of these improvements (p < 0.05).

Marfo, William [University of Texas at El Paso,Dep↗

Engineering spin coherence in core-shell diamond nanocrystals

Fluorescent diamond nanocrystals can host spin qubit sensors capable of probing the physical properties of biological systems with nanoscale spatial resolution. Sub-100 nm diamond nanosensors can readily be delivered into intact cells and even living organisms. However, applications beyond current proof-of-principle experiments require a substantial increase in sensitivity, which is limited by surface induced charge instability and electron-spin dephasing. In this work, we utilize engineered core-shell structures to achieve a drastic increase in qubit coherence times (T 2 ) from 1.1 to 35 μs in bare nanodiamonds to upward of 52 to 87 μs. We use electron-paramagnetic-resonance results to present a band bending model and connect silica encapsulation to the removal of deleterious mid-gap surface states that are negatively affecting the qubit’s spin properties. Combined with a 1.9-fold increase in particle luminescence these advances correspond to up to two-order-of-magnitude reduction in integration time. Probing qubit dynamics at a single particle level further reveals that the noise characteristics fundamentally change from a bath with spins that rearrange their spatial configuration during the course of an experiment to a more dilute static bath. The observed results shed light on the underlying mechanisms governing fluorescence and spin properties in diamond nanocrystals and offer an effective noise mitigation strategy based on engineered core-shell structures.

core-shell↗

Mechanical Actuation Mechanism Design for Cryogenic Microwave Cavities in Axion Dark Matter Searches

Resonant Microwave Cavities are placed in a strong magnetic field at cryogenic temperatures (~.1K) in order to try to convert axions into detectable photons. A major challenge is to tune the cavity to allow no interference with the desired environment used for the experiment, which enables the system to operate near absolute zero and maintain superconductivity, thereby reducing noise as much as possible. My project focuses on developing and testing a low-thermal-conductivity gear reduction system with a 1000:1 ratio for cavity tuning. This gear system could significantly improve the thermal and electromagnetic interference of the tuning mechanism, helping ADMX scan for axions more accurately.

Ortega, Giancarlo [Marquette U.; Fermilab]↗

Weak-Form Latent Space Dynamics Identification

This software showcases the enhanced capabilities of the Latent Space Dynamics Identification (LaSDI) algorithm through the application of the weak form, resulting in WLaSDI. WLaSDI first compresses the data, then projects it onto test functions, and subsequently learns the local latent space models. Notably, WLaSDI demonstrates significantly improved robustness to noise. Using weak-form equation learning techniques, WLaSDI achieves local latent space modeling. Compared to the standard sparse identification of nonlinear dynamics (SINDy) used in LaSDI, the variance reduction of the weak form ensures robust and precise latent space recovery, enabling fast, robust, and accurate simulations. We demonstrate the efficacy of WLaSDI against LaSDI using several common benchmark examples, including viscid and inviscid Burgers', radial advection, and heat conduction. For instance, in 1D inviscid Burgers' simulations with up to 100% Gaussian white noise, WLaSDI maintains relative errors consistently below 6%, whereas LaSDI errors can exceed 10,000%. Similarly, in radial advection simulations, WLaSDI keeps relative errors below 16%, compared to potential errors of up to 10,000% with LaSDI. Additionally, WLaSDI achieves significant speedups, such as a 140X speedup in 1D Burgers' simulations compared to the corresponding full order model.

Choi, Youngsoo↗

Super-Resolution Ptychography with Small Segmented Detectors

To overcome the spatial resolution limit set by aperture-limited diffraction in traditional scanning transmission electron microscopy, microscopists have developed ptychography enabled by iterative phase retrieval algorithms and high-dynamic-range pixel array detectors. Current detector designs are limited by the data rate off chip, so a high-pixel-count detector has a proportionally lower frame rate than the few-segment detectors used for differential phase contrast (DPC) imaging. This slower acquisition speed leads to heightened vulnerability to scan noise, drift, and potential sample damage. This creates opportunities for repurposing fast segmented detectors for ptychography by trading a reduction in reciprocal space pixels for an increase in real space pixels. Here, we explore a strategy of oversampling in real space and instead apply detector pixel upsampling during the reconstruction process. Further, we demonstrate the viability of achieving super-resolution ptychography on thin objects using only 2 × 2 detector pixels, surpassing the resolution of integrated DPC (iDPC) imaging. With optimization using simulated datasets and experiments on MoTe 2 /WSe 2 bilayer moiré superlattices, we achieved super-resolution ptychography reconstructions under rapid acquisition conditions (37.5 pA, 1 μs dwell time), yielding over 50% improvements in contrast and information limit compared to annular dark field and iDPC imaging on the same detectors.

2D materials↗