Search NASA⌕ Search

SEARCH · Search NASA

Results for “Navigation system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The First Human Trial of Transoral Robotic Surgery Using a Single-Port Robotic System in the Treatment of Laryngo-Pharyngeal Cancer

Background: This study aimed to evaluate the feasibility and safety of the DaVinci SP system for performing transoral robotic surgery (TORS) in patients with head and neck cancer. Methods: From October 2018 to April 2019, the medical records of 41 patients who underwent TORS using the DaVinci SP system were retrospectively reviewed. Results: During TORS, three robotic arms could be used to perform a geometric resection of the lesion in a narrow working space. The mean total operation time was 60 min, and the average time required to set up the robotic system was 10 min or less. All patients successfully underwent TORS. All robotic arms were inserted through a single port, which widened the working space around the patient’s head and allowed the operative assistant an easy approach to the patient during the operation. The joggle joint of the robotic arms aided easy manipulation within the confined working space. The joggle joints of the endoscopic arm were controlled through the navigation system, which was very helpful in securing superior visualization of the surgical site, especially in the area of the larynx and the hypopharynx. Conclusion: The study confirmed that the DaVinci SP system provided technical advantages above the Si and Xi systems for performing TORS. It was especially helpful in ensuring proper visualization of the surgical field and in performing precise surgery during surgery to the tongue base or the hypopharyngeal lesion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Waste Information Management System-2012 - 12114

The Waste Information Management System (WIMS) -2012 was updated to support the Department of Energy (DOE) accelerated cleanup program. The schedule compression required close coordination and a comprehensive review and prioritization of the barriers that impeded treatment and disposition of the waste streams at each site. Many issues related to waste treatment and disposal were potential critical path issues under the accelerated schedule. In order to facilitate accelerated cleanup initiatives, waste managers at DOE field sites and at DOE Headquarters in Washington, D.C., needed timely waste forecast and transportation information regarding the volumes and types of radioactive waste that would be generated by DOE sites over the next 40 years. Each local DOE site historically collected, organized, and displayed waste forecast information in separate and unique systems. In order for interested parties to understand and view the complete DOE complex-wide picture, the radioactive waste and shipment information of each DOE site needed to be entered into a common application. The WIMS application was therefore created to serve as a common application to improve stakeholder comprehension and improve DOE radioactive waste treatment and disposal planning and scheduling. WIMS allows identification of total forecasted waste volumes, material classes, disposition sites, choke points, technological or regulatory barriers to treatment and disposal, along with forecasted waste transportation information by rail, truck and inter-modal shipments. The Applied Research Center (ARC) at Florida International University (FIU) in Miami, Florida, developed and deployed the web-based forecast and transportation system and is responsible for updating the radioactive waste forecast and transportation data on a regular basis to ensure the long-term viability and value of this system. WIMS continues to successfully accomplish the goals and objectives set forth by DOE for this project. It has replaced the historic process of each DOE site gathering, organizing, and reporting their waste forecast information utilizing different databases and display technologies. In addition, WIMS meets DOE's objective to have the complex-wide waste forecast and transportation information available to all stakeholders and the public in one easy-to-navigate system. The enhancements to WIMS made since its initial deployment include the addition of new DOE sites and facilities, an updated waste and transportation information, and the ability to easily display and print customized waste forecast, the disposition maps, GIS maps and transportation information. The system also allows users to customize and generate reports over the web. These reports can be exported to various formats, such as Adobe{sup R} PDF, Microsoft Excel{sup R}, and Microsoft Word{sup R} and downloaded to the user's computer. Future enhancements will include database/application migration to the next level. A new data import interface will be developed to integrate 2012-13 forecast waste streams. In addition, the application is updated on a continuous basis based on DOE feedback. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Entanglement-enhanced atomic gyroscope

The advent of increasingly precise gyroscopes has played a key role in the technological development of navigation systems. Ring-laser and fiber-optic gyroscopes, for example, are widely used in modern inertial guidance systems and rely on the interference of unentangled photons to measure mechanical rotation. The sensitivity of these devices scales with the number of particles used as 1/{radical}(N). Here we demonstrate how, by using sources of entangled particles, it is possible to do better and even achieve the ultimate limit allowed by quantum mechanics where the precision scales as 1/N. We propose a gyroscope scheme that uses ultracold atoms trapped in an optical ring potential.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Underwater Mapping Results for Seabotix vLBV300 Vehicle with Tritech Gemini 720i Imaging Sonar near Newport, OR

This document presents results from tests to demonstrate underwater mapping capabilities of an underwater vehicle in conditions typically found in marine renewable energy arrays. These tests were performed with a tethered Seabotix vLBV300 underwater vehicle. The vehicle is equipped with an inertial navigation system (INS) based on a Gladiator Landmark 40 IMU and Teledyne Explorer Doppler Velocity Log, as well as a Gemini 720i scanning sonar acquired from Tritech. The results presented include both indoor pool and offshore deployments. The indoor pool deployments were performed on October 7, 2016 and February 3, 2017 in Corvallis, OR. The offshore deployment was performed on April 20, 2016 off the coast of Newport, OR (44.678 degrees N, 124.109 degrees W). During the mission period, the sea state varied between 3 and 4, with an average significant wave height of 1.6 m. Data was recorded from both the INS and the sonar.

16 TIDAL AND WAVE POWER↗

Flat-Panel Cone-Beam Ct-Guided Radiofrequency Ablation of Very Small (≤1.5 cm) Liver Tumors: Technical Note on a Preliminary Experience

PurposeThe aim of the present study was to investigate the technical feasibility of flat-panel cone-beam CT (CBCT)-guided radiofrequency ablation (RFA) of very small (<1.5 cm) liver tumors.Materials and MethodsPatients included were candidates for hepatic percutaneous RFA as they had single biopsy-proven hepatic tumors sized ≤1.5 cm and poorly defined on ultrasonography. Following apnea induction, unenhanced CBCT scans were acquired and used to deploy the RF electrode with the aid of a virtual navigation system. If the tumor was not clearly identified on the unenhanced CBCT scan, a right retrograde arterial femoral access was established to carry out hepatic angiography and localize the tumor. Patients’ lesions and procedural variables were recorded and analyzed.ResultsThree patients (2 male and 1 female), aged 68, 76, and 87 years were included; 3 lesions (2 hepato-cellular carcinoma and 1 metastasis from colorectal cancer) were treated. One patient required hepatic angiography. Cycles of apnea used to acquire CBCT images and to deploy the electrode lasted <120 s. Mean fluoroscopic time needed to deploy the electrode was 36.6 ± 5.7 min. Mean overall procedural time was 66.0 ± 22.9 min. No peri- or post-procedural complications were noted. No cases of incomplete ablation were noted at 1-month follow-up.ConclusionPercutaneous CBCT-guided liver RFA with or without arterial hepatic angiography is technically feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance

Purpose: A flat-panel detector based mobile isocentric C-arm for cone-beam CT (CBCT) has been developed to allow intraoperative 3D imaging with sub-millimeter spatial resolution and soft-tissue visibility. Image quality and radiation dose were evaluated in spinal surgery, commonly relying on lower-performance image intensifier based mobile C-arms. Scan protocols were developed for task-specific imaging at minimum dose, in-room exposure was evaluated, and integration of the imaging system with a surgical guidance system was demonstrated in preclinical studies of minimally invasive spine surgery. Methods: Radiation dose was assessed as a function of kilovolt (peak) (80-120 kVp) and milliampere second using thoracic and lumbar spine dosimetry phantoms. In-room radiation exposure was measured throughout the operating room for various CBCT scan protocols. Image quality was assessed using tissue-equivalent inserts in chest and abdomen phantoms to evaluate bone and soft-tissue contrast-to-noise ratio as a function of dose, and task-specific protocols (i.e., visualization of bone or soft-tissues) were defined. Results were applied in preclinical studies using a cadaveric torso simulating minimally invasive, transpedicular surgery. Results: Task-specific CBCT protocols identified include: thoracic bone visualization (100 kVp; 60 mAs; 1.8 mGy); lumbar bone visualization (100 kVp; 130 mAs; 3.2 mGy); thoracic soft-tissue visualization (100 kVp; 230 mAs; 4.3 mGy); and lumbar soft-tissue visualization (120 kVp; 460 mAs; 10.6 mGy) - each at (0.3 x 0.3 x 0.9 mm{sup 3}) voxel size. Alternative lower-dose, lower-resolution soft-tissue visualization protocols were identified (100 kVp; 230 mAs; 5.1 mGy) for the lumbar region at (0.3 x 0.3 x 1.5 mm{sup 3}) voxel size. Half-scan orbit of the C-arm (x-ray tube traversing under the table) was dosimetrically advantageous (prepatient attenuation) with a nonuniform dose distribution ({approx}2 x higher at the entrance side than at isocenter, and {approx}3-4 lower at the exit side). The in-room dose (microsievert) per unit scan dose (milligray) ranged from {approx}21 {mu}Sv/mGy on average at tableside to {approx}0.1 {mu}Sv/mGy at 2.0 m distance to isocenter. All protocols involve surgical staff stepping behind a shield wall for each CBCT scan, therefore imparting {approx}zero dose to staff. Protocol implementation in preclinical cadaveric studies demonstrate integration of the C-arm with a navigation system for spine surgery guidance-specifically, minimally invasive vertebroplasty in which the system provided accurate guidance and visualization of needle placement and bone cement distribution. Cumulative dose including multiple intraoperative scans was {approx}11.5 mGy for CBCT-guided thoracic vertebroplasty and {approx}23.2 mGy for lumbar vertebroplasty, with dose to staff at tableside reduced to {approx}1 min of fluoroscopy time ({approx}40-60 {mu}Sv), compared to 5-11 min for the conventional approach. Conclusions: Intraoperative CBCT using a high-performance mobile C-arm prototype demonstrates image quality suitable to guidance of spine surgery, with task-specific protocols providing an important basis for minimizing radiation dose, while maintaining image quality sufficient for surgical guidance. Images demonstrate a significant advance in spatial resolution and soft-tissue visibility, and CBCT guidance offers the potential to reduce fluoroscopy reliance, reducing cumulative dose to patient and staff. Integration with a surgical guidance system demonstrates precise tracking and visualization in up-to-date images (alleviating reliance on preoperative images only), including detection of errors or suboptimal surgical outcomes in the operating room.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high‐order discontinuous Galerkin approach for physics‐based thermospheric modeling

Abstract The accurate prediction of aerodynamic drag on satellites orbiting in the upper atmosphere is critical to the operational success of modern space technologies, such as satellite‐based communication or navigation systems, which have become increasingly popular in the last few years due to the deployment of constellations of satellites in low‐Earth orbit. As a result, physics‐based models of the ionosphere and thermosphere have emerged as a necessary tool for the prediction of atmospheric outputs under highly variable space weather conditions. This paper proposes a high‐fidelity approach for physics‐based space weather modeling based on the solution of the Navier–Stokes equations using a high‐order discontinuous Galerkin method, combined with a matrix‐free strategy suitable for high‐performance computing on GPU architectures. The approach consists of a thermospheric model that describes a chemically frozen neutral atmosphere in nonhydrostatic equilibrium driven by the external excitation of the Sun. A novel set of variables is considered to treat the low densities present in the upper atmosphere and to accommodate the wide range of scales present in the problem. At the same time, and unlike most existing approaches, radial and angular directions are treated in a nonsegregated approach. The study presents a set of numerical examples that demonstrate the accuracy of the approximation and validate the current approach against observational data along a satellite orbit, including estimates of established empirical and physics‐based models of the ionosphere‐thermosphere system. Finally, a one‐dimensional radial derivation of the physics‐based model is presented and utilized for conducting a parametric study of the main thermal quantities under various solar conditions.

Engineering↗

Performance of a Robotic Assistance Device in Computed Tomography-Guided Percutaneous Diagnostic and Therapeutic Procedures

PurposeTo evaluate a commercially available robotic assistance device for computed tomography-guided diagnostic and therapeutic interventions, compared to regular, manually performed CT scan-guided interventions in terms of precision, exposure to radiation to the patient and intervention time.Materials and MethodsOver a period of 6 months, 55 consecutive patients were recruited and treated using robotic assistance and compared to a control group of 101 patients previously treated with a regular CT scan-guided, manual approach. Evaluated parameters were precision (deviation from planned target and number of needle replacements), radiation exposure to the patient and intervention time. Evaluations were performed with regard to complexity (in-plane vs out-of-plane interventions) and type of anesthesia (general vs local).ResultsParameters related to precision were in general significantly better in the robotic assistance group (p < 0.01) with a mean deviation of 1.2 mm (± 1.6 mm) compared to 2.6 mm (± 1.1 mm) in the comparison group. Compared to manual procedure, the mean intervention time was reduced by 15 min (± 5.4 min) on average for an out-of-plane needle placement in the robotic group. There was no increase of exposure to radiation to the patient while radiation exposure for the physician was reduced to zero when the navigation system was used.ConclusionCompared to manual placement, the use of a robotic assistance device in out-of-plane CT-guided interventions under general anesthesia allows for probe placement with high precision. Intervention time is reduced with no increase of exposure to radiation to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-frequency, self-sustained oscillations in inductively coupled plasmas used for optical pumping

We have investigated very low frequency, on the order of one hertz, self-pulsing in alkali-metal inductively-coupled plasmas (i.e., rf-discharge lamps). This self-pulsing has the potential to significantly vary signal-to-noise ratios and (via the ac-Stark shift) resonant frequencies in optically pumped atomic clocks and magnetometers (e.g., the atomic clocks now flying on GPS and Galileo global navigation system satellites). The phenomenon arises from a nonlinear interaction between the atomic physics of radiation trapping and the plasma's electrical nature. To explain the effect, we have developed an evaporation/condensation theory (EC theory) of the self-pulsing phenomenon.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nonlinear plasma experiments in geospace with gigawatts of RF power at HAARP

The ionosphere is the ionized uppermost layer of our atmosphere (from 70 – 500 km altitude) where free electron densities yield peak critical frequencies in the HF (3 – 30 MHz) range. The ionosphere thus provides a quiescent plasma target, stable on timescales of minutes, for a whole host of active plasma experiments. High power RF experiments on ionospheric plasma conducted in the U.S. have been reported since 1970. The largest HF transmitter built to date is the HAARP phased-array HF transmitter near Gakona, Alaska which can deliver up to 3.6 Gigawatts (ERP) of CW RF power in the range of 2.8 – 10 MHz to the ionosphere with microsecond pointing, power modulation, and frequency agility. With an ionospheric background thermal energy in the range of only 0.1 eV, this amount of power gives access to the highest regimes of the nonlinearity (RF intensity to thermal pressure) ratio. HAARP’s unique features have enabled the conduct of a number of unique nonlinear plasma experiments in the interaction region of overdense ionospheric plasma including generation of artificial aurorae, artificial ionization layers, VLF wave-particle interactions in the magnetosphere, parametric instabilities, stimulated electromagnetic emissions (SEE), strong Langmuir turbulence (SLT) and suprathermal electron acceleration. Diagnostics include the Modular UHF Ionospheric Radar (MUIR) sited at HAARP, the SuperDARN-Kodiak HF radar, spacecraft radio beacons, HF receivers to record stimulated electromagnetic emissions (SEE) and telescopes and cameras for optical emissions. We report on short timescale ponderomotive overshoot effects, artificial field-aligned irregularities (AFAI), the aspect angle dependence of the intensity of the HF-enhanced plasma line, and production of suprathermal electrons. One of the primary missions of HAARP, has been the generation of ELF (300 – 3000 Hz) and VLF (3 – 30 kHz) radio waves which are guided to global distances in the Earth-ionosphere waveguide. We review recent efforts to improve the efficiency of the generation ELF/VLF and develop alternative mechanisms that do not require a natural ionospheric current. Applications include the controlled study of ionospheric irregularities affecting spacecraft communication and navigation systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modelling of rotation-induced frequency shifts in whispering gallery modes

We study the angular velocity sensors based on whispering gallery mode resonators. Rotation of such resonators gives rise to various effects that can cause a spectral shift of their modes. Optical methods allow this shift to be determined with high precision, which can be used practically to measure the angular velocity in inertial orientation and navigation systems. The basic principles of constructing the angular velocity sensors utilising these effects are considered, their advantages and drawbacks are indicated. We also study the interrelation between the effects and the possibility of their mutual influence on each other. Based on the analytical studies of the effects, we consider the possibility of their combined application for angular velocity measurements. (review)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Miniature quantum frequency standard based on the phenomenon of coherent population trapping in vapours of {sup 87}Rb atoms

We report the results of the development and production of a quantum frequency standard (QFS) based on the coherent population trapping (CPT) resonance observed on the D{sub 1} absorption line of {sup 87}Rb atoms. The effect of various physical factors on the QFS frequency is studied, and the optimal physical parameters of the device to attain the best frequency stability are determined. The measured relative frequency instability (Allan deviation) is ∼9 × 10{sup −12} for the averaging time of 1 s, 3 ×10{sup −13} for 1000 s, and 1.5 ×10{sup −12} for 24 hours. For a volume of 60 cm{sup 3}, the power consumption of the entire device is 300 mW. The designed QFS can be used in a new-generation satellite navigation systems with increased accuracy and reliability, as well as for solving a number of other problems of science and technology. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Robot for Investigations and Assessments of Nuclear Areas

RIANA is a remote controlled Robot dedicated for Investigations and Assessments of Nuclear Areas. The development of RIANA is motivated by the need to have at disposal a proven robot, tested in hot cells; a robot capable of remotely investigate and characterise the inside of nuclear facilities in order to collect efficiently all the required data in the shortest possible time. It is based on a wireless medium sized remote carrier that may carry a wide variety of interchangeable modules, sensors and tools. It is easily customised to match specific requirements and quickly configured depending on the mission and the operator's preferences. RIANA integrates localisation and navigation systems. The robot will be able to generate / update a 2D map of its surrounding and exploring areas. The position of the robot is given accurately on the map. Furthermore, the robot will be able to autonomously calculate, define and follow a trajectory between 2 points taking into account its environment and obstacles. The robot is configurable to manage obstacles and restrict access to forbidden areas. RIANA allows an advanced control of modules, sensors and tools; all collected data (radiological and measured data) are displayed in real time in different format (chart, on the generated map...) and stored in a single place so that may be exported in a convenient format for data processing. This modular design gives RIANA the flexibility to perform multiple investigation missions where humans cannot work such as: visual inspections, dynamic localization and 2D mapping, characterizations and nuclear measurements of floor and walls, non destructive testing, samples collection: solid and liquid. The benefits of using RIANA are: - reducing the personnel exposures by limiting the manual intervention time, - minimizing the time and reducing the cost of investigation operations, - providing critical inputs to set up and optimize cleanup and dismantling operations. (authors)

42 ENGINEERING↗

SU-C-BRA-07: Virtual Bronchoscopy-Guided IMRT Planning for Mapping and Avoiding Radiation Injury to the Airway Tree in Lung SAbR

Purpose: Post-treatment radiation injury to central and peripheral airways is a potentially important, yet under-investigated determinant of toxicity in lung stereotactic ablative radiotherapy (SAbR). We integrate virtual bronchoscopy technology into the radiotherapy planning process to spatially map and quantify the radiosensitivity of bronchial segments, and propose novel IMRT planning that limits airway dose through non-isotropic intermediate- and low-dose spillage. Methods: Pre- and ∼8.5 months post-SAbR diagnostic-quality CT scans were retrospectively collected from six NSCLC patients (50–60Gy in 3–5 fractions). From each scan, ∼5 branching levels of the bronchial tree were segmented using LungPoint, a virtual bronchoscopic navigation system. The pre-SAbR CT and the segmented bronchial tree were imported into the Eclipse treatment planning system and deformably registered to the planning CT. The five-fraction equivalent dose from the clinically-delivered plan was calculated for each segment using the Universal Survival Curve model. The pre- and post-SAbR CTs were used to evaluate radiation-induced segmental collapse. Two of six patients exhibited significant segmental collapse with associated atelectasis and fibrosis, and were re-planned using IMRT. Results: Multivariate stepwise logistic regression over six patients (81 segments) showed that D0.01cc (minimum point dose within the 0.01cc receiving highest dose) was a significant independent factor associated with collapse (odds-ratio=1.17, p=0.010). The D0.01cc threshold for collapse was 57Gy, above which, collapse rate was 45%. In the two patients exhibiting segmental collapse, 22 out of 32 segments showed D0.01cc >57Gy. IMRT re-planning reduced D0.01cc below 57Gy in 15 of the 22 segments (68%) while simultaneously achieving the original clinical plan objectives for PTV coverage and OAR-sparing. Conclusion: Our results indicate that the administration of lung SAbR can Result in significant injury to bronchial segments, potentially impairing post-SAbR lung function. To our knowledge, this is the first investigation of functional avoidance based on mapping and minimizing dose to individual bronchial segments. The presenting author receives research funding from Varian Medical Systems, Elekta, and VisionRT.

60 APPLIED LIFE SCIENCES↗

SU-E-J-111: Finite Element-Based Deformable Image Registration of Pleural Cavity for Photodynamic Therapy

Purpose: The pleural volumes will deform during surgery portion of the pleural photodynamic therapy (PDT) of lung cancer when the pleural cavity is opened. This impact the delivered dose when using highly conformal treatment techniques. In this study, a finite element-based (FEM) deformable image registration is used to quantify the anatomical variation between the contours for the pleural cavities obtained in the operating room and those determined from pre-surgery computed tomography (CT) scans. Methods: An infrared camera-based navigation system (NDI) is used during PDT to track the anatomical changes and contour the lung and chest cavity. A series of CTs of the lungs, in the same patient, are also acquired before the surgery. The structure contour of lung and the CTs are processed and contoured in Matlab and MeshLab. Then, the contours are imported into COMSOL Multiphysics 5.0, where the FEM-based deformable image registration is obtained using the deformed mesh - moving mesh (ALE) model. The NDI acquired lung contour is considered as the reference contour, and the CT contour is used as the target one, which will be deformed. Results: The reconstructed three-dimensional contours from both NDI and CT can be converted to COMSOL so that a three-dimensional ALE model can be developed. The contours can be registered using COMSOL ALE moving mesh model, which takes into account the deformation along x, y and z-axes. The deformed contour has good matches to the reference contour after the dynamic matching process. The resulting 3D deformation map can be used to obtain the locations of other critical anatomic structures, e.g., heart, during surgery. Conclusion: Deformable image registration can fuse images acquired by different modalities. It provides insights into the development of phenomenon and variation in normal anatomical structures over time. The initial assessments of three-dimensional registration show good agreement.

60 APPLIED LIFE SCIENCES↗

3D localization of electrophysiology catheters from a single x-ray cone-beam projection

Purpose: X-ray images allow the visualization of percutaneous devices such as catheters in real time but inherently lack depth information. The provision of 3D localization of these devices from cone beam x-ray projections would be advantageous for interventions such as electrophysiology (EP), whereby the operator needs to return a device to the same anatomical locations during the procedure. A method to achieve real-time 3D single view localization (SVL) of an object of known geometry from a single x-ray image is presented. SVL exploits the change in the magnification of an object as its distance from the x-ray source is varied. The x-ray projection of an object of interest is compared to a synthetic x-ray projection of a model of said object as its pose is varied. Methods: SVL was tested with a 3 mm spherical marker and an electrophysiology catheter. The effect of x-ray acquisition parameters on SVL was investigated. An independent reference localization method was developed to compare results when imaging a catheter translated via a computer controlled three-axes stage. SVL was also performed on clinical fluoroscopy image sequences. A commercial navigation system was used in some clinical image sequences for comparison. Results: SVL estimates exhibited little change as x-ray acquisition parameters were varied. The reproducibility of catheter position estimates in phantoms denoted by the standard deviations, (σ{sub x}, σ{sub y}, σ{sub z}) = (0.099 mm, 0.093 mm, 2.2 mm), where x and y are parallel to the detector plane and z is the distance from the x-ray source. Position estimates (x, y, z) exhibited a 4% systematic error (underestimation) when compared to the reference method. The authors demonstrated that EP catheters can be tracked in clinical fluoroscopic images. Conclusions: It has been shown that EP catheters can be localized in real time in phantoms and clinical images at fluoroscopic exposure rates. Further work is required to characterize performance in clinical images as well as the sensitivity to clinical image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-I-50: Finite Element-Based Deformable Image Registration of Lung and Heart

Purpose: Photodynamic therapy (PDT) is used after surgical resection to treat the microscopic disease for malignant pleural mesothelioma and to increase survival rates. Although accurate light delivery is imperative to PDT efficacy, the deformation of the pleural volume during the surgery impacts the delivered light dose. To facilitate treatment planning, we use a finite-element-based (FEM) deformable image registration to quantify the anatomical variation of lung and heart volumes between CT pre-(or post-) surgery and surface contours obtained during PDT using an infrared camera-based navigation system (NDI). Methods: NDI is used during PDT to obtain the information of the cumulative light fluence on every cavity surface point that is being treated. A wand, comprised of a modified endotrachial tube filled with Intralipid and an optical fiber inside the tube, is used to deliver the light during PDT. The position of the treatment is tracked using an attachment with nine reflective passive markers that are seen by the NDI system. Then, the position points are plotted as three-dimensional volume of the pleural cavity using Matlab and Meshlab. A series of computed tomography (CT) scans of the lungs and heart, in the same patient, are also acquired before and after the surgery. The NDI and CT contours are imported into COMSOL Multiphysics, where the FEM-based deformable image registration is obtained. The NDI and CT contours acquired during and post-PDT are considered as the reference, and the Pre-PDT CT contours are used as the target, which will be deformed. Results: Anatomical variation of the lung and heart volumes, taken at different times from different imaging devices, was determined by using our model. The resulting three-dimensional deformation map along x, y and z-axes was obtained. Conclusion: Our model fuses images acquired by different modalities and provides insights into the variation in anatomical structures over time.

60 APPLIED LIFE SCIENCES↗

Drones for Decommissioning

The U.S. Nuclear Regulatory Commission has responsibility for regulating the safe decommissioning of facilities and sites to meet the License Termination Rule in 10 Code of Federal Regulations (CFR) Part 20, Standards for Protection Against Radiation, Subpart E “Radiological Criteria for License Termination.” Decommissioning is performed in accordance with 10 CFR Part 50, Domestic Licensing of Production and Utilization Facilities, as part of license termination (§50.82) and release of the facility or site for unrestricted use (§50.83). The guidance currently demonstrates the minimum requirements and necessary conditions for conducting radiological surveys by a person carrying a radiation detector(s). The Pacific Northwest National Laboratory (PNNL) evaluated the use of an unoccupied aerial vehicle (UAV) to conduct radiological surveys that could be used in decommissioning to potentially reduce time, cost, and worker safety compared to current survey methods. The objective of this project was to evaluate the performance and limitations of a UAV to support a decommissioning radiological survey and compare it to a radiological survey conducted by a human. The primary research questions of interest evaluated were: 1. Did observed UAV paths differ from human paths and, if so, how much? 2. Did survey path deviation affect survey results and, if so, how? 3. Were radiological measurements from human and UAV surveys significantly different? To answer these research questions, an experimental field was set up at PNNL’s 3440 test track, and it included radiological sources commonly surveyed during decommissioning: cobalt-60 (Co-60), cesium-137 (Cs-137), and americium-241 (Am-241). Nine check sources (three each of Am-241, Cs-137, and Co-60) with activities ranging from 3.54 µCi to 39.34 µCi were set over a path that also included an area for measuring background radiation. An Aurelia X6 UAV coupled with a GPS and lidar unit was used to conduct the radiological surveys. UAV and human surveys were conducted using two different NaI(Tl) scintillation radiation detectors (2 in. × 2 in. Ludlum, Inc. and 2 in. × 0.04 in. Alpha Spectra, Inc.) at a travel velocity of approximately 0.2 m/s at a low (15–40 cm median altitude) or high (87–105 cm median altitude) survey altitude. Since the survey velocity and altitude parameters were atypical for normal UAV operations, testing was done prior to conducting the radiological surveys to establish airworthiness, evaluate the navigation system, and establish flight control. Human and UAV surveys were paired according to the detector type and altitude regime to compare the survey data. The results of this proof-of-concept research determined that the UAV and human surveys followed similar survey paths and detected the radiological sources with no significant statistical difference (in 33 out of 36 surveys). However, further research is needed prior to deploying UAVs for decommissioning surveys.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗