Search NASA⌕ Search

SEARCH · Search NASA

Results for “Necking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Direct Feed High-Level Waste APPS Model Glass Testing (DFHLW APPS) Matrix, Phase 2

This report summarizes the data collected during the batching and melting of a second matrix of Direct Feed High-Level Waste (DFHLW) glasses generated using the preliminary enhanced waste glass models (EWG2.5) and the Britton and Anderson (2024) preliminary DFHLW feed vector. The purpose of these glasses is two-fold: 1. Validate EWG2.5 glass calculations being used in the Aspen Process Performance Simulation (APPS) model. 2. Evaluate and ultimately improve the glass property models and formulation methods used for design of DFHLW glasses as part of an iterative process of data collection and model refinement. Some of the 16 APPS2 glasses tested did not satisfy all target property constraints due to the limited data on DFHLW glass supporting the EWG2.5 models. • One glass, APPS2-10, formed nepheline on canister centerline cooling (CCC) heat-treatment and failed the product consistency test (PCT) response limits. This glass also had high B and Cr release rates for the toxicity characteristic leaching procedure (TCLP). All other glasses were found to satisfy the PCT and TCLP constraints for both quenched and CCC samples. • One glass, APPS2-08, had higher than acceptable viscosity due to magnetite crystallization. • One glass, APPS2-09, formed greater than 2 vol% crystals at 950 °C. As the glass design criterion was that the temperature at 2 vol% crystal (T 2% ) be less than 950 °C, only one glass failed the criteria. However, this criterion is being reevaluated. Four additional glasses formed crystal fractions between 1 and 2 vol% at 950 °C (APPS2-03, -08, -12, and -14). • Four glasses – APPS2-01, -02, -04, and -16 – failed the Monofrax K-3 refractory neck corrosion (k neck ) design limit of 0.04 in. at 1208 °C for 6 d. This is another criterion being reevaluated. Four additional glasses (APPS2-05, -06, -11, and -13) exhibited 0.025 = k neck = 0.04 in. • All 16 glasses passed the sulfur solubility and TCLP constraints. The measured property values were compared to predicted values using EWG2.5 and a selection of other existing models. A few models (e.g., electrical conductivity, TCLP) were found to be adequate for designing DFHLW glasses in the near future, while others require refits or offsets. It is recommended that new property models be developed for EWG3.0, as a large amount of DFHLW glass property data (> 14 × existing data) is expected to be collected in the compositional spaces where no data was previously available. To enable near-term calculations and formulations for designing DFHLW glasses and processing rate estimations, a formulation algorithm with minor modifications will be developed, EWG2.6.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Insert system for an airfoil and method of installing same

An insert system for an airfoil is provided. The airfoil includes a plenum that extends into an aft portion of the airfoil. The plenum includes a plenum inlet and an entirety of the plenum inlet is defined axially forward of the aft portion. The insert system includes a first and second insert. The first insert and the second insert include a plurality of impingement openings defined therein. The first insert includes a first neck portion. The first insert is sized for insertion into the plenum radially through the plenum inlet and the first insert is movable aftward within the plenum into an installed position such that the first neck portion is positioned aftward in the plenum inlet. The second insert is sized for insertion into the plenum radially through the plenum inlet forward of the first neck portion in the installed position.

42 ENGINEERING↗

Insert system for an airfoil and method of installing same

An insert system for an airfoil plenum includes a first insert and a second insert that include a plurality of impingement openings defined therein. The first insert includes a forward-facing inlet opening. The second insert includes a neck portion having a radial-facing inlet opening, an aft opening, and a cavity in flow communication between the radial-facing inlet opening and the aft opening. The second insert is sized for insertion into the plenum radially through a plenum inlet such that the neck portion is positioned in the plenum inlet. The first insert is sized for insertion into the second insert radially through the radial-facing inlet opening. When the neck portion is positioned in the plenum inlet, the first insert is moveable aftward through the aft opening into an installed position such that the forward-facing inlet opening opens into the cavity.

Berry, Jonathan Dwight↗

Shape-memory polymer foam device for treating aneurysms

A system for treating an aneurysm in a blood vessel or vein, wherein the aneurysm has a dome, an interior, and a neck. The system includes a shape memory polymer foam in the interior of the aneurysm between the dome and the neck. The shape memory polymer foam has pores that include a first multiplicity of pores having a first pore size and a second multiplicity of pores having a second pore size. The second pore size is larger than said first pore size. The first multiplicity of pores are located in the neck of the aneurysm. The second multiplicity of pores are located in the dome of the aneurysm.

Ortega, Jason M.↗

Screening and Validation of Molecular Targeted Radiosensitizers

The development of molecular targeted drugs with radiation and chemotherapy is critically important for improving the outcomes of patients with hard-to-treat, potentially curable cancers. However, too many preclinical studies have not translated into successful radiation oncology trials. Major contributing factors to this insufficiency include poor reproducibility of preclinical data, inadequate preclinical modeling of intertumoral genomic heterogeneity that influences treatment sensitivity in the clinic, and a reliance on tumor growth delay instead of local control (TCD50) endpoints. There exists an urgent need to overcome these barriers to facilitate successful clinical translation of targeted radiosensitizers. To this end, we have used 3-dimensional (3D) cell culture assays to better model tumor behavior in vivo. Examples of successful prediction of in vivo effects with these 3D assays include radiosensitization of head and neck cancers by inhibiting epidermal growth factor receptor or focal adhesion kinase signaling, and radioresistance associated with oncogenic mutation of KRAS. To address the issue of tumor heterogeneity, we leveraged institutional resources that allow high-throughput 3D screening of radiation combinations with small-molecule inhibitors across genomically characterized cell lines from lung, head and neck, and pancreatic cancers. This high-throughput screen is expected to uncover genomic biomarkers that will inform the successful clinical translation of targeted agents from the National Cancer Institute Cancer Therapy Evaluation Program portfolio and other sources. Screening “hits” need to be subjected to refinement studies that include clonogenic assays, addition of disease-specific chemotherapeutics, target/biomarker validation, and integration of patient-derived tumor models. The chemoradiosensitizing activities of the most promising drugs should be confirmed in TCD50 assays in xenograft models with or without relevant biomarker and using clinically relevant radiation fractionation. We predict that appropriately validated and biomarker-directed targeted therapies will have a higher likelihood than past efforts of being successfully incorporated into the standard management of hard-to-treat tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of the Formability of High-Purity Polycrystalline Niobium Sheets for Superconducting Radiofrequency Applications

The forming limit diagram (FLD) of high-purity niobium sheets used for the manufacturing of superconducting radiofrequency (SRF) cavities is presented. The Marciniak (in-plane) test was used with niobium blanks with a thickness of 1 mm and blank carriers of annealed oxygen-free electronic (OFE) copper. A high formability was measured, with an approximate true major strain at necking for plane strain of 0.44. The high formability of high-purity niobium is likely caused by its high strain rate sensitivity of 0.112. Plastic strain anisotropies (r-values) of 1.66, 1.00, and 2.30 were measured in the 0 deg, 45 deg, and 90 deg directions. However, stress–strain curves at a nominal strain rate of ~10 –3 s –1 showed similar mechanical properties in the three directions. Theoretical calculations of the forming limit curves (FLCs) were conducted using an analytical two-zone model. The obtained results indicate that the anisotropy and strain rate sensitivity of niobium affect its formability. The model was used to investigate the influence of strain rate on strains at necking. The obtained results suggest that the use of high-speed sheet forming should further increase the formability of niobium.

mechanical behavior↗

Predicting fracture behavior in single crystal nickel using a coupled crystal plasticity phase field damage approach

Understanding the fracture behavior of single crystal metals is critical for predicting material performance under mechanical loading. Here, in this study, we investigate the fracture characteristics of single crystal nickel tensile bars using a crystal plasticity coupled phase field damage (CP-PFD) model. Experimental tensile tests were conducted on 15 specimens spanning five crystallographic orientations and three thickness variants per orientation. The results revealed two distinct fracture modes: brittle fractures with 45-degree angled surfaces and ductile fractures characterized by significant necking. The CP-PFD model successfully replicated these fracture behaviors, demonstrating strong agreement with experimental observations. The model effectively predicted the strain at which necking and fracture occurred, as well as the orientation-dependent fracture mechanisms. By comparing experimental and simulated fracture surfaces, we establish the CP-PFD model as a robust tool for predicting single crystal behavior and damage evolution. This work provides insight into the microstructural dependence of fracture behavior and establishes a predictive framework for modeling orientation-dependent damage evolution in single-crystal nickel.

Crystal plasticity↗

Optimization of overhang printing in ceramic binder jetting additive manufacturing

Cylindrical-shaped horizontally-hanging overhangs with different heights on a solid cubic body were printed via binder jetting additive manufacturing with sililcon carbide powder feedstock. Cracking on the overhang neck and sagging on the overhang body were observed both pre- and post-curing, especially on printed design with a smaller particle size of 10 μm. Here, it was found that the width of cracking and depth of sagging were dependent on the height relative to the solid body in the powder bed, and elevated position of overhang with large volume of underneath loose powder led to increased extend of cracking and sagging. Overhang diameter and weight were varied, which were found with no apparent effects on its deformation extend. To mitigate cracking and sagging, contactless support was designed and tested, which could significantly improve the overhang stability and avoid any overhang deformations. Support gap and support distance were studied for their effects on support capability. The printing processes with and without contactless support were simulated by a finite element modeling approach to understand the stress distribution and evolution of the overhang structures, which revealed stress concentrations on the upper neck point of the designed overhang.

Binder jetting↗

Bicontinuous nanoporous design induced homogenization of strain localization in metallic glasses

Bicontinuous nanoporous metallic glasses (MG) synergize the outstanding properties of MGs and open-cell nanoporous materials. The low-density and high-specific-surface-area of bicontinuous nanoporous structures have the potential to enhance the applicability of MGs in catalysis, sensors, and lightweight structural designs. In this work, we report molecular dynamics simulations of tensile loading deformation and failure of bicontinuous nanoporous Cu 64 Zr 36 MG with 55% porosity and 4.4 nm ligament size. Results indicate an anomalous mechanical behavior featuring delocalized plastic deformation preceding ductile failure. The deformation follows two mechanisms: i) Necking of ligaments aligned with the loading direction and ii) progressive alignment of randomly oriented ligaments. Failure occurs at 0.16 strain, following massive rupture of ligaments. This work indicates that a bicontinuous nanoporous design is able to effectively delocalize strain localization in a MG due to a combination of size effect on the ductility of MGs resulting in nano ligaments necking and progressive asynchronous alignment of ligaments.

36 MATERIALS SCIENCE↗

The Effect of Monomer Size on Fusion and Coupling in Colloidal Quantum Dot Molecules

The fusion step in the formation of colloidal quantum dot molecules, constructed from two core/shell quantum dots, dictates the coupling strength and hence their properties and enriched functionalities compared to monomers. Herein, studying the monomer size effect on fusion and coupling, we observe a linear relation of the fusion temperature with the inverse nanocrystal radius. This trend, similar to that in nanocrystal melting, emphasizes the role of the surface energy. The suggested fusion mechanism involves intraparticle ripening where atoms diffuse to the reactive connecting neck region. Moreover, the effect of monomer size and neck filling on the degree of electronic coupling is studied by combined atomistic-pseudopotential calculations and optical measurements, uncovering strong coupling effects in small QD dimers, leading to significant optical changes. Understanding and controlling the fusion and hence coupling effect allows tailoring the optical properties of these nanoscale structures, with potential applications in photonic and quantum technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Role of Superlattice Phonons in Charge Localization Across Quantum Dot Arrays

Understanding charge transport in semiconductor quantum dot (QD) assemblies is important for developing the next generation of solar cells and light-harvesting devices based on QD technology. One of the key factors that governs the transport in such systems is related to the hybridization between the QDs. Recent experiments have successfully synthesized QD molecules, arrays, and assemblies by directly fusing the QDs, with enhanced hybridization leading to high carrier mobilities and coherent band-like electronic transport. Here, in this work, we theoretically investigate the electron transfer dynamics across a finite CdSe-CdS core-shell QD array, considering up to seven interconnected QDs in one dimension. We find that, even in the absence of structural and size disorder, electron transfer can become localized by the emergent low-frequency superlattice vibrational modes when the connecting neck between QDs is narrow. On the other hand, we also identify a regime where the same vibrational modes facilitate coherent electron transport when the connecting necks are wide. Overall, we elucidate the crucial effects of electronic and superlattice symmetries and their couplings when designing high-mobility devices based on QD superlattices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microscopic evidence for scission neutrons

We discuss the neck rupture stage of fission and the emission of particles afterwards, two extremely rapid and highly non-equilibrium processes. Currently, the neck rupture cannot be directly probed by experiment, highlighting the importance of reliable theoretical predictions for this stage of fission. Time-dependent density functional theory (TDDFT) is used to simulate the spontaneous fission of 252 Cf. In conjunction with statistical models, inputs from microscopic calculations can be used to make predictions for prompt neutron and gamma emission spectra, quantities which can be experimentally measured. Here we characterize the scission mechanism within TDDFT and estimate the number of scission neutrons and their kinetic energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Subdomain cryo-EM structure of nodaviral replication protein A crown complex provides mechanistic insights into RNA genome replication

For positive-strand RNA [(+)RNA] viruses, the major target for antiviral therapies is genomic RNA replication, which occurs at poorly understood membrane-bound viral RNA replication complexes. Recent cryoelectron microscopy (cryo-EM) of nodavirus RNA replication complexes revealed that the viral double-stranded RNA replication template is coiled inside a 30- to 90-nm invagination of the outer mitochondrial membrane, whose necked aperture to the cytoplasm is gated by a 12-fold symmetric, 35-nm diameter “crown” complex that contains multifunctional viral RNA replication protein A. Here we report optimizing cryo-EM tomography and image processing to improve crown resolution from 33 to 8.5 Å. This resolves the crown into 12 distinct vertical segments, each with 3 major subdomains: A membrane-connected basal lobe and an apical lobe that together comprise the ~19-nm-diameter central turret, and a leg emerging from the basal lobe that connects to the membrane at ~35-nm diameter. Despite widely varying replication vesicle diameters, the resulting two rings of membrane interaction sites constrain the vesicle neck to a highly uniform shape. Labeling protein A with a His-tag that binds 5-nm Ni-nanogold allowed cryo-EM tomography mapping of the C terminus of protein A to the apical lobe, which correlates well with the predicted structure of the C-proximal polymerase domain of protein A. These and other results indicate that the crown contains 12 copies of protein A arranged basally to apically in an N-to-C orientation. Moreover, the apical polymerase localization has significant mechanistic implications for template RNA recruitment and (-) and (+)RNA synthesis.

59 BASIC BIOLOGICAL SCIENCES↗

Swab Tensile Testing Results [Slides]

HP PA11 material swabs predominantly broke at the joint between the head and the neck, although there was significant variation in the break locations. HP PA12, Injection Molded, and FormLabs (Surgical Guide V1 Resin) material swabs predominately broke in the neck region.

36 MATERIALS SCIENCE↗

Report on partially complete post-irradiation-examination of the INL samples

Ferritic-martensitic steels (NF616 and T91), and austenitic stainless steel 800H and its Grain Boundary Engineering (GBE)-treated version 800H-TMP (ThermoMechanical Processing) were irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) and their microstructures and mechanical properties were characterized. Ferritic-martensitic steels were irradiated up to 8.16 dpa in the irradiation temperatures ranging from 241 °C to 447.5 °C. Selected 800H and 800H-TMP samples were also irradiated up to 9.12 dpa at 359°C to 431°C. Vickers hardness measurement, fractography, and microstructural characterization were performed on the selected samples in the LAMDA lab. Radiation-induced hardening of NF616 and T91 was observed in the hardness measurements which show ~37% to ~65% increases, depending on irradiation dose and irradiation temperature. Within the irradiation conditions studied in this work, samples with a higher dose had a higher hardness. All the tested alloy 800H and 800H-TMP in this work showed irradiation-hardening by ~96±7% to ~152±10%. Alloy 800HTMP tended to have slightly smaller irradiation-hardening than alloy 800H. The fractography of NF616 samples D2 (2.96 dpa at 291.5°C), D4 (5.91 dpa at 359°C), and D6 (8.16 dpa at 431°C) indicated loss of ductility with negligible necking for the sample D2, yet obvious ductile failure for samples D4 and D6. Fractography of alloy 800H samples N4 (7.27 dpa at 359°C), N5 (3.9 dpa at 451.5°C), and N6 (9.01 dpa at 431°C), and alloy 800H-TMP samples P4 (7.36 dpa at 359°C), P5 (3.95 dpa at 451.5°C), and P6 (9.12 dpa at 431°C) indicated that all samples failed in a ductile mode, with obvious necking. Dimples were observed where large Ti-containing particles were observed for the samples. TEM characterization was performed on alloy 800H (N4, N5, N6) and 800H-TMP (P4, P5 and P6). Accumulation of M23C6 precipitates at grain boundaries was observed in all samples, and the presence of Ti(C,N) precipitates at grain boundaries and in the matrix was observed in alloy 800H-TMP. M23C6 precipitates were found to have the cube-on-cube orientation relationship with the matrix. In addition, nanoscale Si-rich clusters were observed in the matrix of all samples. Atom probe tomography was conducted on the same samples, and their results are being analyzed to be integrated with the TEM results for a confident description of the clustering behavior. Due to the low irradiation temperature (up to 451.5°C), dislocation loops formed in all samples, with the density and the average size of dislocation loops in the order of 1022 – 1023 m-3 and 11.7 – 15.9 nm, respectively. The loop densities in alloy 800H were higher than that in alloy 800H-TMP under the same irradiation conditions. Further systematic data analyses, together with some complementary experiments, will be pursued for these samples to foster peer-reviewed journal article publications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Microscopic Evidence for Scission Neutrons

We discuss the neck rupture stage of fission and the emission of particles afterwards, two extremely rapid and highly non-equilibrium processes. Currently, the neck rupture cannot be directly probed by experiment, highlighting the importance of reliable theoretical predictions for this stage of fission. Time-dependent density functional theory (TDDFT) is used to simulate the spontaneous fission of 252 Cf. In conjunction with statistical models, inputs from microscopic calculations can be used to make predictions for prompt neutron and gamma emission spectra, quantities which can be experimentally measured. Here we characterize the scission mechanism within TDDFT and estimate the number of scission neutrons and their kinetic energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In Situ Investigation of Upper Airway Occlusion in Sleep Disordered Breathing Using Ultrasonic Transducer Arrays

This work presents a novel application of ultrasound for the real-time, non-invasive investigation of occlusion of the upper airway during events of obstructive sleep apnea/hypopnea syndrome. It is hypothesized that ultrasonic pulses applied to the neck during apneic events produce spectral and temporal features that can detect apnea occurrence. Theoretical models of ultrasound propagation and an in vitro test were conducted to test this hypothesis in both transmission and reflection modes. Complete specifications and technical details of the system design and fabrication, which is mounted on each subject’s neck, are presented, including the methodology. Nine patients (seven male and two female, mean age of 42 years, with a range of 25 to 56 years, and body mass index 37.6 ± 6.6 kg/m2) were recruited for a full night study, which included simultaneous nocturnal polysomnography for the validation of the results. Nine temporal features and four spectral features were extracted from the envelope of the received pulse waveform. These were used to compute 26 metrics to quantify the changes in the ultrasonic waveforms between normal breathing and apneic events. The statistical analysis of the collected ultrasonic data showed that at least two or more of the proposed features could detect apneic events in all subjects. The findings establish the feasibility of the proposed method as a cost-effective and non-invasive OSAHS screening tool.

60 APPLIED LIFE SCIENCES↗

Comparison of Motion Analysis Systems in Tracking Upper Body Movement of Myoelectric Bypass Prosthesis Users

Current literature lacks a comparative analysis of different motion capture systems for tracking upper limb (UL) movement as individuals perform standard tasks. To better understand the performance of various motion capture systems in quantifying UL movement in the prosthesis user population, this study compares joint angles derived from three systems that vary in cost and motion capture mechanisms: a marker-based system (Vicon), an inertial measurement unit system (Xsens), and a markerless system (Kinect). Ten healthy participants (5F/5M; 29.6 ± 7.1 years) were trained with a TouchBionic i-Limb Ultra myoelectric terminal device mounted on a bypass prosthetic device. Participants were simultaneously recorded with all systems as they performed standardized tasks. Root mean square error and bias values for degrees of freedom in the right elbow, shoulder, neck, and torso were calculated. The IMU system yielded more accurate kinematics for shoulder, neck, and torso angles while the markerless system performed better for the elbow angles. By evaluating the ability of each system to capture kinematic changes of simulated upper limb prosthesis users during a variety of standardized tasks, this study provides insight into the advantages and limitations of using different motion capture technologies for upper limb functional assessment.

42 ENGINEERING↗