Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Tungsten thermal neutron dosimeter

Tungsten-185 activity, which is produced by neutron activation of tungsten-184, determines thermal neutron flux. Radiochemical separation methods and counting techniques for irradiated tungsten provide accurate determination of the radiation exposure.

Ball, L. L.↗

Nuclear Science Symposium, 31st and Symposium on Nuclear Power Systems, 16th, Orlando, FL, October 31-November 2, 1984, Proceedings

Topics related to physics instrumentation are discussed, taking into account cryostat and electronic development associated with multidetector spectrometer systems, the influence of materials and counting-rate effects on He-3 neutron spectrometry, a data acquisition system for time-resolved muscle experiments, and a sensitive null detector for precise measurements of integral linearity. Other subjects explored are concerned with space instrumentation, computer applications, detectors, instrumentation for high energy physics, instrumentation for nuclear medicine, environmental monitoring and health physics instrumentation, nuclear safeguards and reactor instrumentation, and a 1984 symposium on nuclear power systems. Attention is given to the application of multiprocessors to scientific problems, a large-scale computer facility for computational aerodynamics, a single-board 32-bit computer for the Fastbus, the integration of detector arrays and readout electronics on a single chip, and three-dimensional Monte Carlo simulation of the electron avalanche in a proportional counter.

Biggerstaff, J. A.↗

The response of a 0.03-cm silicon detector to a mixed neutron and gamma field as a function of shield material and thickness

The neutron and gamma radiation from a MHW-RTG was used to evaluate the total response of a shielded 0.3-mm silicon detector. The generator employs a 2200 W(th) PuO2 heat source concept known as the HELIPAK. The total integrated neutron and gamma ray fluxes at 100 cm away from the source along the radial direction were 1.67 x 1,000 n/sq cm/s and 1.49 x 10,000 gamma sq cm/s, respectively. Experimental values of the response function of the shielded silicon detector were used to determine the total counting rates due to photons at bias energies ranging from 50 to 200 keV. For neutrons, analytically computed response functions were used to determine the total counting rates at the same bias energies. It was found that for an aluminum shield the neutrons are not significant, regardless of the thickness of the shield. However, the magnitude of the total counting rate due to neutrons increases with increased atomic number of the shield and becomes comparable to the counting rate due to photons for a platinum shield thickness of 5 cm.

Taherzadeh, M.↗

Very energetic gamma-rays from the June 3, 1982 solar flare

The Gamma-Ray Spectrometer on the SMM satellite has recorded high-energy gamma-ray and neutron emission from the flare on June 3, 1982. During the 65-s impulsive phase the gamma rays above 10 MeV contain emissions from both primary electron bremsstrahlung and nuclear pion decay. Hence the impulsive phase acceleration process must produce both primary electrons with energies above 60 MeV and ions above 500 MeV. This flare also has a extended emission phase lasting more than 1000 s which is most easily observed at gamma-ray energies above 10 MeV. After removing the counting rates from the more slowly moving neutrons produced at earlier times, the resulting gamma ray spectrum can be entirely explained by nuclear pion production. Over 70 percent of the pions were produced in the extended emission phase. In contrast, more than 70 percent of the high-energy primary electron bremsstrahlung and the nuclear line emission produced by ions below 30 MeV occurred in the 65-s impulsive phase. This represents the first clear observation of a new acceleration process which produces an electron-deficient, very hard ion spectrum extending beyond 1000 MeV.

Forrest, D. J.↗

A mercuric detector system for X-ray astronomy. 2. Results from flight tests of a balloon borne instrument

To establish the expected sensitivity of a new hard X-ray telescope design, an experiment was conducted to measure the background counting rate at balloon altitudes (40 km) of mercuric iodide, a room temperature solid state X-ray detector. The prototype detector consisted of two thin mercuric iodide (HgI2) detectors surrounded by a large bismuth germanate (Bi4Ge3O12) scintillator operated in anticoincidence. The bismuth germanate shield vetoed most of the background counting rate induced by atmospheric gamma-rays, neutrons and cosmic rays. A balloon-borne gondola containing a prototype detector assembly was designed, constructed and flown twice in the spring of 1982 from Palestine, Texas. The second flight of this instrument established a differential background counting rate of 4.2 O.7 x 10-5 counts/sec cm keV over the energy range of 40 to 80 keV. This measurement was within 50% of the predicted value. The measured rate is approx 5 times lower than previously achieved in shielded NaI/CsI or Ge systems operating in the same energy range. The prediction was based on a Monte Carlo simulation of the detector assembly in the radiation environment at float altitude.

Vallerga, J.↗

A mercuric iodide detector system for X-ray astronomy. II - Results from flight tests of a balloon borne instrument

To establish the expected sensitivity of a new hard X-ray telescope design, described by Ricker et al., an experiment was conducted to measure the background counting rate at balloon altitudes (40 km) of mercuric iodide, a room temperature solid state X-ray detector. The prototype detector consisted of two thin mercuric iodide (HgI2) detectors surrounded by a large bismuth germanate scintillator operated in anticoincidence. The bismuth germanate shield vetoed most of the background counting rate induced by atmospheric gamma-rays, neutrons and cosmic rays. A balloon-borne gondola containing a prototype detector assembly was designed, constructed and flown twice in the spring of 1982 from Palestine, TX. The second flight of this instrument established a differential background counting rate of 4.2 + or - 0.7 x 10 to the -5th counts/s sq cm keV over the energy range of 40-80 keV. This measurement was within 50 percent of the predicted value. The measured rate is about 5 times lower than previously achieved in shielded NaI/CsI or Ge systems operating in the same energy range.

Vallerga, J. V.↗

Detection sensitivities in 3-8 MeV neutron activation

Study of detection sensitivities of 73 radioactive elements using fast unmoderated neutrons includes experiments for irradiation, cooling and counting conditions. The gamma ray emission spectra is used to identify the unknown material.

Wahlgren, M. A.↗

Accreting, Isolated Neutron Stars: Preheated of Infalling Gas and Cometary H II Regions - 3

Nearby, isolated, old neutron stars (IONSs) accreting interstellar material might be detectable as sources of UV and soft X-ray radiation. We investigate the interaction between this radiation field and the surrounding medium, assumed to consist of purely hydrogen and helium. This interaction results in a cometary H II region around the star which we model in detail by including all the relevant time-dependent ionization, recombination, heating, and cooling processes. We find that preheating of the ambient gas to temperatures higher than 10(exp 4) K may significantly quench the accretion rate onto these neutron stars, thereby reducing the IONS number counts in the EUV and soft X-ray bands predicted by previous investigations. However, the reprocessing of hard radiation by the surrounding H II regions may enhance the detectability of IONSs at optical wavelengths. Searches for nearby accreting IONSs are currently being undertaken.

Madau, Piero↗

Designing Lightweight Neutron Absorbing Composites Using a Comprehensive Absorber Areal Density Metric

Efforts to lightweight neutron absorbing composites are limited by incomplete understandings of the interaction between absorbing particles and their matrices. In this study, analytical models and a more physically representative simulation evaluated the penalty to neutron absorbing performance due to neutron channeling between large absorbing particles. Models and simulation agreed that B 4 C particles smaller than 100μm and especially those smaller than 10μm did not cause excessive neutron channeling. A more comprehensive neutron absorbing composite design metric – boron-10 equivalent areal density, which considers the particle size penalty and the matrix contribution to absorptivity – was introduced and used to estimate lightweighting via matrix substitution. Calculations using this new metric showed that a non-absorbing Mg matrix reduced mass by up to 35% over Al, constrained by the difference in mass density, while an absorbing Mg–Li matrix reduced mass by up to 60%, exceeding the difference in mass densities alone. Measurement of apparent absorber areal density through two experimental techniques – foil activation and direct counting – validated estimated absorber areal density as a neutron absorbing composite design metric. This updated understanding of the particle size penalty, newly introduced design metric, and experimental validation demonstrate a path to lightweight neutron absorbing composites.

Radiation shielding↗

High Spatial Resolution Studies of Epithermal Neutron Emission from the Lunar Poles: Constraints on Hydrogen Mobility

The data from the collimated sensors of the LEND instrument are shown to be of exceptionally high quality. Counting uncertainties are about 0.3% relative and are shown to be the only significant source of random error, thus conclusions based on small differences in count rates are valid. By comparison with the topography of Shoemaker crater, the spatial resolution of the instrument is shown to be consistent with the design value of 5 km for the radius of the circle over which half the counts from the lunar surface would be determined. The observed epithermal-neutron suppression factor due to the hydrogen deposit in Shoemaker crater of 0.25 plus or minus 0.04 cps is consistent with the collimated field-of-view rate of 1.7 cps estimated by Mitrofanov et al. (2010a). The statistical significance of the neutron suppressed regions (NSRs) relative to the larger surrounding polar region is demonstrated, and it is shown that they are not closely related to the permanently shadowed regions. There is a significant increase in H content in the polar regions independent of the H content of the NSRs. The non-NSR H content increases directly with latitude, and the rate of increase is virtually identical at both poles. There is little or no increase with latitude outside the polar region. Various mechanisms to explain this steep increase in the non-NSR polar H with latitude are investigated, and it is suggested that thermal volatilization is responsible for the increase because it is minimized at the low surface temperatures close to the poles.

neutron↗

Observation of the Radiation Environment and Solar Energetic Particle Events in Mars Orbit in May 2018- June 2022

Epithermal Neutron Detector (FREND). Here we present results from measurements of the charged particle fluxes, dose rates and estimation of dose equivalent rates at ExoMars TGO Mars science orbit, provided by Liulin-MO from May 2018 to June 2022. The period of measurements covers the declining and minimum phases of the solar activity in 24th solar cycle and the rising phase of the 25th cycle. Compared are the radiation values of the galactic cosmic rays (GCR) obtained during the different phases of the solar activity. The highest values of the dose rate and flux from GCR are registered from March to August 2020. At the minimum of 24th and transition to 25th solar cycle the dose rate from GCR is 15.9 ± 1.6 µGy h−1, particle flux is 3.3 ± 0.17 cm−2 s−1, dose equivalent rate is 72.3 ± 14.4 µSv h−1. Since September 2020 the dose rate and flux of GCR decrease. Particular attention is drawn to the observation of the solar energetic particle (SEP) events in July, September and October 2021, February and March 2022 as well as their effects on the radiation environment on TGO during the corresponding periods. The SEP event during15–19 February 2022 is the most powerful event observed in our data. The SEP dose during this event is 13.8 ± 1.4 mGy (in Si), the SEP dose equivalent is 21.9 ± 4.4 mSv. SEP events recorded in Mars orbit are related to coronal mass ejections (CME) observed by SOHO and STEREO A coronagraphs. Compared are the time profiles of the count rates measured by Liulin-MO, the neutron detectors of FREND and neutron detectors of the High Energy Neutron Detector (HEND) aboard Mars Odyssey during 15–19 February 2022 event. The data obtained is important for the knowledge of the radiation environment around Mars, regarding future manned and robotic flights to the planet. The data for SEP events in Mars orbit during July 2021-March 2022 contribute to the details on the solar activity at a time when Mars is on the opposite side of the Sun from Earth.

Jordanka Semkova↗

Zr-Hf-Ta fractionation during lunar evolution

Zr/Hf ratios and other elemental data in 68 samples of various mare basalts, KREEP units, and lunar glasses have been determined using instrumental neutron activation analysis coupled with coincidence-anticoincidence counting for greater precision. The data are presented in order to quantify further the amount of Zr/Hf fractionation that has occurred during primordial crystallization and cumulate remelting or by any other process. Models of Zr-Hf evolution are developed to place additional constraints on the bulk lunar composition and on the effects of minor phases that may be responsible for the observed fractionations. The Hf-Ta fractionation in lunar compositions is also reviewed in order to characterize normal Hf(4+) versus Ta(4+) behavior and to delineate possible effects due to the oxidation of Ta(4+) to Ta(5+) during late-stage ilmenite crystallization.

Hughes, S. S.↗

A preliminary summary of the observations of the 16 February 1984 solar flare (STIP Interval XV, 12-21 February 1984)

The solar flare on 16 Feb. 1984 (0900 UT) and the associated photon and particle emissions were perhaps the most interesting solar and interplanetary phenomena during STIP Interval XV, 12 to 21 Feb. 1984. The X-ray and microwave radio emissions, as observed from the Earth, were relatively weak and no optical flare was reported. However, the hard X-ray and low energy gamma-ray observations made with the Pioneer Venus Orbiter spacecraft behind the west limb of the Sun indicate that the flare was, in reality, very intense. There is evidence that the flare was located approx 40 deg behind the west limb of the Sun and hence, for instruments located near the Earth, the most intense parts of the X-ray and microwave radio sources were occulted by the photosphere. However, the effect of occultation on the metric type II, type III, and type IV and decimetric (type DCIM) radio sources appeared to be relatively small. Following the flare, a large increase in the counting rates was recorded by several ground level neutron monitors and energetic particle detectors located in interplanetary space. A preliminary analysis of the 16 Feb. 1984 flare observations follows.

Kane, S. R.↗

Detection With Rhessi of High Frequency X-ray Oscillations in the Tail of the 2004 Hyperflare From SGR 1806-20

The recent discovery of high frequency oscillations in giant flares from SGR 1806-20 and SGR 1900+14 may be the first direct detection of vibrations in a neutron star crust. If this interpretation is correct it offers a novel means of testing the neutron star equation of state, crustal breaking strain, and magnetic field configuration. Using timing data from RHESSI, we have confirmed the detection of a 92.5 Hz Quasi-Periodic Oscillation (QPO) in the tail of the SGR 1806-20 giant flare. We also find another, stronger, QPO at higher energies, at 626.5 Hz. Both QPOs are visible only at particular (but different) rotational phases, implying an association with a specific area of the neutron star surface or magnetosphere. At lower frequencies we confirm the detection of an 18 Hz QPO, at the same rotational phase as the 92.5 Hz QPO, and report the additional presence of a broad 26 Hz QPO. We are however unable to make a robust confirmation of the presence of a 30 Hz QPO, despite higher count rates. We discuss our results in the light of neutron star vibration models.

Watts, Anna L.↗

Total body calcium analysis

A technique to quantitate total body calcium in humans is developed. Total body neutron irradiation is utilized to produce argon 37. The radio argon, which diffuses into the blood stream and is excreted through the lungs, is recovered from the exhaled breath and counted inside a proportional detector. Emphasis is placed on: (1) measurement of the rate of excretion of radio argon following total body neutron irradiation; (2) the development of the radio argon collection, purification, and counting systems; and (3) development of a patient irradiation facility using a 14 MeV neutron generator. Results and applications are discussed in detail.

Lewellen, T. K.↗

Low scatter lightweight fission spectrometer constructed for biological research

Low scatter, lightweight fission spectrometer provides a simple, reliable method for determining absolute neutron fluxes in a fixed neutron. It minimizes neutron scatter and energy degradation effects, and has a counting volume large enough to intercept the most energetic fission fragments, yet small enough to be discriminating.

Frigerio, N. A.↗

A direct observation of solar neutrons following the 0118 UT flare on 1980 June 21

The Gamma Ray Spectrometer on the Solar Maximum Mission satellite has observed energetic solar neutrons (greater than 50 MeV) at the earth following a solar flare that occurred on the west limb on June 21, 1980 at 01:18:20 UT. Impulsive photon emission from 10 keV to greater than 65 MeV lasting over a period of about 66 s was followed by a transient flux of 50-600 MeV neutrons incident over a 17 minute period. The peak counting rate corresponds to an average flux at the earth of (3.8 + or - 0.6) x 10 to the -2nd neutrons/sq cm s at 130 MeV. These observations indicate the emission of 3 x 10 to the 28th neutrons/sr with energies greater than 50 MeV, requiring the rapid acceleration (much less than 60 s) of protons to GeV energies during the impulsive phase of the flare.

Chupp, E. L.↗

A large area detector for neutrons between 2 and 100 MeV

A neutron detector sensitive from 2 to 100 MeV is described. The detector is designed for high altitude balloon flight to measure the flux, energy and direction of albedo neutrons from the earth and to search for solar neutrons. A neutron scatter from a proton is required in each of two liquid scintillator tanks spaced 1 meter apart. The energy of the recoil proton in the first tank is obtained from pulse height analysis of the scintillator output. The energy of the recoil neutron is obtained from its time of flight between the tanks. The detector has been calibrated with 15.3 MeV neutrons and mu mesons. The minimum detectable flux is 10(-4) neutron/sq cm/sec at a counting rate of one per minute; the energy resolution is 12% at 15 MeV and 30% at 100 MeV. The angle between the incoming neutron and the recoil neutron is measured to + or - 10 deg.

Grannan, R. T.↗