Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron coincidence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A fi eld-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt gamma-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium gamma-ray detector. Fine spatial resolution neutron and alpha detectors enable precise mapping of characteristic gamma-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus signifi cantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A fi eld-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt gamma-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium gamma-ray detector. Fine spatial resolution neutron and alpha detectors enable precise mapping of characteristic gamma-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus signifi cantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

233 U oxide Measurement Campaign Data: Passive and Active Neutron Multiplicity Measurements of Uranium Oxide Samples at Oak Ridge National Laboratory

During FY2023, three measurement campaigns were conducted at Oak Ridge National Laboratory. The goal was to quantify the neutron signatures of samples of uranium oxide containing uranium 233 and uranium-235. This report presents the neutron multiplicity data obtained using the large volume active well coincidence counter (LV-AWCC).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of 17 N as a time-tagged neutron source for calibration of large antineutrino detectors

Large antineutrino detectors hold the potential for remote nuclear reactor monitoring and discovery, which is of great interest for nonproliferation and treaty verification applications. Correlated-particle calibration sources are especially useful for large-volume designs based on detection of inverse beta-decay events, as the timing information of the coincident particles improves background rejection and event reconstruction. 17 N is a promising calibration source since it emits beta-correlated delayed neutrons and can be produced relatively easily using high-energy neutrons. In this work, we examine the feasibility of 17 N as a time-tagged calibration source for large antineutrino detectors. 17 N was produced using a DT neutron generator from a water sample enriched in 17 O, and the observed production rates were found to be consistent with previous measurements of the 17 O(n,p) 17 N reaction cross-section. As a result, time-tagging of 17 N delayed neutrons is demonstrated via beta-neutron coincidence measurements conducted using a specialized beta detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structure of even-even Sr isotopes with 50 ≤ N ≤ 58 neutrons

Excited levels in Sr 90 , Sr 92 , Sr 94 , and Sr 96 nuclei were reinvestigated using high-statistics multiple- γ coincidence data from neutron-induced fission of U 235 and spontaneous fission of Cf 252 , measured using Exogam at Institut Laue Langevin and Gammasphere arrays, respectively. The experimental goal was the search for new excited levels and firm spin-parity assignments to known levels. A total of 23 new levels with 30 new or corrected decays and 39 new or improved spin-parity assignments were obtained in the four nuclei. Negative-parity structures on top of 3 - excitation were firmly identified and extended to higher spins. New positive-parity structures in Sr 94 and Sr 96 were observed with 3 + excitations characteristic of γ collectivity. The 277.7-keV, E 2 decay from the 1507.0-keV level to the second 0 + level in Sr 96 , found in this paper, completes the coexisting deformed band in this nucleus. To learn about the microscopic structure of levels in the Sr 88 - 96 nuclei, we performed large-scale shell-model calculations. The calculations compared to the experiment, helped the discussion of the evolution of collectivity in strontium isotopes, highlighting the important role of various single-particle excitations in phase transitions and shape coexistence in the region. The special role of the neutron 9 / 2 + [ 404 ] extruder as a catalyst of the deformation change in the region is highlighted.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Instrumentation for correlated prompt n – γ emission studies in coincidence with fission fragments

Recent theoretical and experimental results have brought renewed interest and focus on the topic of fission fragment angular momentum. Measurements of neutrons and rays in coincidence with fission fragments remain the most valuable tool in the exploration of fission physics. To achieve these scientific goals, we have developed a system that combines a state-of-the-art fission fragment detector and n – γ radiation detectors. A new twin Frisch-gridded ionization chamber has been designed and constructed for use with a spontaneous fission source and an array of forty trans-stilbene organic scintillators (FS-3) at Argonne National Laboratory. The new ionization chamber design we present in this work aims at minimizing particle attenuation in the chamber walls, and provides a compact apparatus that can be fit inside existing experimental systems. The ionization chamber is capable of measuring fission fragment masses and kinetic energies, whereas the FS-3 provides neutron and γ-ray multiplicities and spectra. Here, the details of both detector assemblies are presented along with the first experimental results of this setup. Planned event-by-event analysis and future experiments are briefly discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

252 Cf yield calibration method for nuclear material accountancy and safeguards practitioners

Californium-252 is an isotope commonly encapsulated as a physically small but strong spontaneous fission neutron source for applications in industry, academia, and research. Within the nuclear safeguards community, a well-characterized 252 Cf source is often used as an accessible alternative for plutonium in calibrations measurements, which require the absolute source strength. Current methods of source strength quantification can provide an accurate estimate, approximately 1% uncertainty under optimal conditions, but are typically costly and time consuming. An alternative method was developed to determine 252 Cf source strength using passive neutron correlation counting (PNCC). The PNCC method enables institutions and facilities to perform 252 Cf source calibration measurements in-house using detection systems that are common within the nuclear safeguards community. This novel method was previously successfully demonstrated using neutron multiplicity well counters. However, the previous evaluation utilized detection systems with high neutron detection efficiencies, greater than 60%. The purpose of the current study is to extend the previous evaluation and demonstrate the feasibility of the PNCC 252 Cf calibration method for suite of coincidence counters with lower neutron detection efficiencies, between 15% and 35%, which are more commonly encountered in the field, as well as to provide a step-by-step guide to using the method. The neutron source used in this evaluation was previously certified by the National Institutes of Science and Technology (NIST), which provides a reference for the accuracy of the PNCC method. In conclusion, the present source yield calculations demonstrate excellent agreement with a NIST calibration technique and achieve a standard uncertainty below the target 1%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

169 Tm ( n , γ ) cross section and statistical decay properties from measurements at the DANCE facility

Background: Radiative neutron capture on thulium, which is a monoisotopic element, plays a role in different applications such as nuclear astrophysics or nuclear burning environments. Considerable discrepancies—reaching 20%—exist between evaluations in the unresolved-resonance region. Furthermore, experimental data on statistical 𝛾 decay in odd-odd rare-earth nuclei is scarce. There are still open questions about the systematics of the so-called scissors mode in the 𝑀⁢1 photon strength function, especially in odd-odd nuclei. Purpose: This work is focused on two main topics—deriving experimental 169 Tm ⁢(𝑛,𝛾) cross section and studying statistical 𝛾 decay of 170 Tm, in particular properties of the scissors mode. Methods: The capture experiments to obtain experimental cross section were performed at the Los Alamos Neutron Science Center using the time-of-flight technique and employing the Detector for Advanced Neutron Capture Experiments. Measured coincident 𝛾-ray spectra were also compared with statistical simulations using the dicebox code to test different models of level density and photon strength functions. Results: The capture cross section was determined from 1.8 eV to 0.97 MeV, the broadest neutron-energy range ever measured for this isotope. Several new resonances have been observed. The statistical 𝛾 decay of 170 Tm cannot be reproduced without a scissors mode resonance centered at ≈ 3.3MeV. Conclusions: The measured cross section in the unresolved-resonance region is generally lower than the latest evaluations. The derived 169 Tm 𝑠-process abundance is expected to increase by a factor of 1.26, while the changes of the abundances of elements heavier than 169 Tm are in the order of 0.2%. The scissors mode properties in 170 Tm are similar to those deduced in previous analyses of neighboring nuclei 168 Er and 166 Ho .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Manufacturing and characterization of a boron-loaded fast-cured plastic organic scintillator

A novel fast-cured, boron-loaded, plastic organic scintillator was developed and characterized. A diisopropylnaphthalene-containing scintillator was manufactured in minutes with the addition of two commercially available fast-curing monomers, isobornyl acrylate (IBOA) and 1,6-Hexanediol dimethacrylate (HDDMA). Further, the light yield of the device was measured to be approximately 70% relative to a similarly sized, but several-year-aged, EJ-276 detector. Using a coincidence capture technique, the neutron capture light output was found to be 87.7 ± 4.2 keVee, which was 1.47 ± 0.07 greater than the light output from a 59.5 keV electron. Producing a viable fast-cured and thermal-neutron-sensitive detector enables the capability to pursue cost-effective 3D printed thermal neutron detectors in a timely manner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma pressure profiles in a sheared-flow-stabilized Z-pinch

We report the plasma pressure reached inside the central plasma column of a sheared-flow-stabilized Z-pinch using Thomson scattering measurements. Building on previously reported experimental results and the analysis methods established for the high temperature and moderate density plasmas generated on the FuZE device, we show evidence of a central plasma region with higher electron temperature and density, which is consistent with a pinch behavior. Elevated electron temperatures up to 2.25 ± 0.8 keV and densities up to (4.9±0.2)×1017 cm−3 are observed to temporally coincide with the fusion neutron production from the plasma. Reconstructed plasma pressure profiles highlight the presence of a several millimeter-wide column with elevated pressure whose location varies shot-to-shot. The plasma pressure rises as neutron production from the deuterium plasma increases, reaching a peak value of 2.6 kBar. This peak value is consistent with a radially force-balanced pinch equilibrium model based on the measured ∼320 kA pinch current. Complete datasets were obtained at two axial locations, 10 and 20 cm axial position from the tip of the central electrode, which corroborate the estimated neutron source axial lengths.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ground calibration and in-flight commissioning of the Gamma-Ray and Neutron Spectrometer (GRNS) for NASA’s Psyche mission

NASA's Psyche spacecraft is currently enroute to the asteroid 16 Psyche, where it will perform an orbital investigation focused on determining the nature of the asteroid. A key part of this investigation is measurements of elemental composition to determine if the asteroid is rich in iron-nickel metal. To that end, the Psyche spacecraft payload includes a Gamma-Ray and Neutron Spectrometer (GRNS). GRNS is composed of two subsystems; a Gamma-Ray Spectrometer (GRS) with a high-purity germanium γ-ray sensor surrounded by a borated plastic scintillator Anti-Coincidence Shield (ACS), and a Neutron Spectrometer (NS) with three 3 He-filled gas proportional counters that are sensitive to different neutron energy regimes. We describe results from the pre-launch calibration campaign, along with early in-flight results from post-launch instrument commissioning. The information detailed here is focused on providing future users of GRNS data with the information needed to properly interpret the observations from the instrument.

Peplowski, Patrick N. [Johns Hopkins Univ., Baltim↗

Measurement of fragment-correlated γ-ray emission from 252 Cf(sf)

This paper presents recent experimental results on the yield of prompt fission γ rays from the spontaneous fission of 252 Cf. We use an ionization chamber to tag fission events and measure the masses and kinetic energies of the fission fragments and trans-stilbene organic scintillators to measure the neutrons and γ rays emitted by the fission fragments. The combination of the ionization chamber and trans-stilbene scintillators allows us to determine the properties of neutrons and γ rays in coincidence with the fragments. The yield of γ rays is known to be influenced by the angular momenta (AM) of the fission fragments. We present experimental evidence indicating that the total γ-ray multiplicity, i.e., the sum of both fragments' emission, saturates at sufficiently high internal fragment excitation energies. We also observe distinct behaviors for the yield of γ rays from the light and heavy fragments, which for certain mass and total kinetic energy (TKE) regions are weakly or anticorrelated, indicating the presence of complex AM generation modes. We also observed a mass- and TKE-dependent anisotropy of the γ rays, which challenges and expands on the conventional notion that the fragments' AM are always aligned perpendicularly to the fission axis. Furthermore, the dependence of the anisotropy on mass and TKE indicates a dependence of these properties on the specific fission channels, thus providing an insight into the deformations and dynamics in fission and their connection with experimentally observable quantities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Emergent Nucleosynthesis from a 1.2 s Long Simulation of a Black Hole Accretion Disk

We simulate a black hole accretion disk system with full-transport general relativistic neutrino radiation magnetohydrodynamics for 1.2 s. This system is likely to form after the merger of two compact objects and is thought to be a robust site of r-process nucleosynthesis. We consider the case of a black hole accretion disk arising from the merger of two neutron stars. Our simulation time coincides with the nucleosynthesis timescale of the r-process (~1 s). Because these simulations are time-consuming, it is common practice to run for a “short” duration of approximately 0.1–0.3 s. We analyze the nucleosynthetic outflow from this system and compare the results of stopping at 0.12 and 1.2 s. We find that the addition of mass ejected in the longer simulation as well as more favorable thermodynamic conditions from emergent viscous ejecta greatly impacts the nucleosynthetic outcome. We quantify the error in nucleosynthetic outcomes between short and long cuts.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Emergent Nucleosynthesis from a 1.2 s Long Simulation of a Black Hole Accretion Disk

Abstract We simulate a black hole accretion disk system with full-transport general relativistic neutrino radiation magnetohydrodynamics for 1.2 s. This system is likely to form after the merger of two compact objects and is thought to be a robust site of r -process nucleosynthesis. We consider the case of a black hole accretion disk arising from the merger of two neutron stars. Our simulation time coincides with the nucleosynthesis timescale of the r -process (∼1 s). Because these simulations are time-consuming, it is common practice to run for a “short” duration of approximately 0.1–0.3 s. We analyze the nucleosynthetic outflow from this system and compare the results of stopping at 0.12 and 1.2 s. We find that the addition of mass ejected in the longer simulation as well as more favorable thermodynamic conditions from emergent viscous ejecta greatly impacts the nucleosynthetic outcome. We quantify the error in nucleosynthetic outcomes between short and long cuts.

79 ASTRONOMY AND ASTROPHYSICS↗

Proton discrimination in CLYC for fast neutron spectroscopy

The Cs 2 LiYCl 6 :Ce (CLYC) elpasolite scintillator is known for its response to fast and thermal neutrons along with good γ-ray energy resolution. While the 35 Cl(n,p) reaction has been identified as a potential means for CLYC-based fast neutron spectroscopy in the absence of time-of-flight (TOF), previous efforts to functionalize CLYC as a fast neutron spectrometer have been thwarted by the inability to isolate proton interactions from 6 Li(n,α) and 35 Cl(n,α) signals. This work introduces a new approach to particle discrimination in CLYC for fission spectrum neutrons using a multi-gate charge integration algorithm that provides excellent separation between protons and heavier charged particles. Neutron TOF data were collected using a 252 Cf source, an array of EJ-309 organic liquid scintillators, and a 6 Li-enriched CLYC scintillator outfitted with fast electronics. Modal waveforms were constructed corresponding to the different reaction channels, revealing significant differences in the pulse characteristics of protons and heavier charged particles at ultrafast, fast, and intermediate time scales. These findings informed the design of a pulse shape discrimination algorithm, which was validated using the TOF data. This study also proposes an iterative subtraction method to mitigate contributions from confounding reaction channels in proton and heavier charged particle pulse height spectra, opening the door for CLYC-based fast neutron and γ-ray spectroscopy while preserving sensitivity to thermal neutron capture signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of proton light yield of water-based liquid scintillator

Abstract The proton light yield of liquid scintillators is an important property in the context of their use in large-scale neutrino experiments, with direct implications for neutrino-proton scattering measurements and the discrimination of fast neutrons from inverse $$\beta $$ β -decay coincidence signals. This work presents the first measurement of the proton light yield of a water-based liquid scintillator (WbLS) formulated from 5% linear alkyl benzene (LAB), at energies below 20 MeV, as well as a measurement of the proton light yield of a pure LAB + 2 g/L 2,5-diphenyloxazole (PPO) mixture (LABPPO). The measurements were performed using a double time-of-flight method and a pulsed neutron beam from the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. The proton light yields were measured relative to that of a 477 keV electron. The relative proton light yield of WbLS was approximately 3.8% lower than that of LABPPO, itself exhibiting a relative proton light yield 15–20% higher than previous measurements of an analogous anoxic sample. The observed quenching is not compatible with the Birks model for either material, but is well described with the addition of Chou’s bimolecular quenching term.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The impact of detection rate changes and correlations on random-coincidence background measurements

Coincidence detection of multiple particles emitted during an experiment can yield a new depth of understanding of the underlying process under study. However, the probability of detecting particles that are generated from the same physical event within a given coincidence time window is generally much lower than that of detecting particles that appear in the same coincidence time window, but were not created from the same physical event, and are therefore detected randomly in coincidence with each other. Thus, accurate and precise methods of measuring this random-coincidence background are essential for a wide variety of fields of science. A method to determine this background directly using the data themselves without any additional experimental run time or fake signals introduced in the data was recently established (O’Donnell, 2016). This method yields a statistical uncertainty on the random-coincidence background that is orders of magnitude smaller than that of the true coincidence data, though the potential for systematic errors of backgrounds from this method was never explored. In this work, we discuss common varieties of correlated and uncorrelated changes in the detection rates of each particle detected in an experiment. Here we demonstrate here that a correlation between particle detection rates from, for example, an incident particle beam that initiates a physical process of interest, creates systematic errors in the random-coincidence background measurement. We also discuss the impact of a variety of other realistic scenarios for rate changes in experiments. Lastly, a method is introduced to correct for errors in the random-coincidence background from any source, yielding an optimization between statistical precision and eliminating potential lingering systematic errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗