Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron fluence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Results of Neutron Dosimetry Measurements for the Advanced Test Reactor Cycle 172A-1

Results of neutron dosimetry measurements in ATR for cycle 172A-1 are presented. Cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

172A↗

Results of Neutron Dosimetry Measurements for the Advanced Test Reactor Cycle 173-C

Results of neutron dosimetry measurements in ATR for cycle 173-C are presented. Cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Portable and Adaptable Neutron Diagnostics for Advancing Fusion Energy Science Addendum

Activation detectors developed at LLNL for measuring real-time neutron fluence from fusion sources are used in the broader fusion community. The recommended fluence operating range of this diagnostic is 5x10 2 – 1x10 6 n/cm2. The upper limit on this fluence range is set by the dead time caused by data transfer between the detector and data acquisition computer. Delaying the start of counting is a possible strategy to operate these detectors in higher fluences.

42 ENGINEERING↗

ACRRF High-Bay Dose Calculations using MCNP (Part A)

Analytical tools and models have been developed as a starting point for directly assessing dose in the Annular Core Research Reactor Facility (ACRRF) due to reactor operation. Key results include peak dose along the Central Cavity (CC) centerline (beamline) at the cavity level, dose throughout the High-Bay (HB), and dose on the facility roof for partially-shielded reactor operation where the 4” insert is removed from the CC Shield Plug (SP). Model results in the beamline are benchmarked against measured doses from passive dosimetry evaluations. Personnel total (neutron and gamma) dose in the ACRRF HB is calculated using Monte Carlo N-Particle (MCNP). Various CC and SP configurations are analyzed, including unshielded (no SP) and partially shielded (SP installed but 4” insert removed). Novel application of Variance Reduction (VR) techniques, namely the Surface Source Write (SSW) and Surface Source Read (SSR) capabilities in MCNP, enable impressive resolution (in a Monte Carlo modeling sense) of dose throughout much the facility. The VR techniques reduce stochastic error for challenging tallies, with more advanced techniques explored in the companion to this report (Part B) [1]. Supplementary studies (including a verification analysis) and pedagogic evaluations in Part B involve neutron spectra, angular distributions, and the dose impact of facility characteristics. With the SP 4” insert removed and the Lead-Boron (44”) Bucket (LB–44) in the reactor cavity, Total Effective Dose (TED) within the CC beamline is ≈140 rem per 300 MJ of reactor yield (or 3900 rem per hour at 100% Steady-State (SS) power). With no SP (unshielded) and a Free-Field (FF) cavity, TED within the beamline is ≈610 rem per 300 MJ (or 17000 rem per hour at 100% SS power). Due to the predicted collimation of radiation by the reactor pool (and partial SP, if present), beamline dose is much greater than the scattered radiation field surrounding the cavity and reactor tank. Comparisons are made to beamline dosimetry measurements to validate the model. Model predictions agree reasonably well (⪅10%) with measured quantities of neutron fluence, gamma fluence, and spectral metrics. Away from the beamline, comparisons made to previous dose measurements in the HB agreement within an order of magnitude.

61 RADIATION PROTECTION AND DOSIMETRY↗

AGR-5/6/7 Thermal Model with Non-uniform Gas Gaps

The daily as-run thermal analysis for the Advanced Gas Reactor (AGR)-5/6/7 experiment was documented in ECAR-5633 (Hawkes 2021). A finite element model was created for the entire test train, which consisted of five capsules. The fuel compacts, graphite holders, stainless-steel capsule walls, and all other major components were individually modeled, including all thermocouples (TCs). Daily heat rates for each compact and component in the model were input from daily as-run physics analyses. Daily gas compositions for each capsule were also input. The thermal conductivity of the compacts and graphite holders varied with fast neutron fluence. Gas mixture thermal conductivity was implemented using experimentally attained values from the literature. Fluence and temperature-dependent thermal conductivity was used for the graphite components and the fuel compacts. Radiation heat transfer was implemented. The model was tuned in an attempt to match the TC readings during the first cycle by adjusting the Neolube (graphite lubricant) thickness.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Postirradiation Examination of WIRE-21 Experiment Irradiated in the High Flux Isotope Reactor

Westinghouse Electric Company is developing wireless sensors to monitor the centerline temperature and internal pressure of commercial light-water reactor fuel rods during irradiation. Oak Ridge National Laboratory and Westinghouse Electric Company developed the Wireless Instrumented RB Experiment 2021 (WIRE-21) to test wireless temperature and pressure sensor technologies in a removable beryllium position in the High Flux Isotope Reactor. The experiment was irradiated for a total of 75 days, at temperatures ranging from approximately 150°C to 400°C, resulting in a peak fast (energy > 0.1 MeV) neutron fluence of about 3 × 10 21 n/cm 2 . The temperature was intentionally cycled multiple times to compare the response of the wireless temperature sensor to collocated thermocouples. Similarly, the pressure sensor was actuated in multiple steps to compare the response of the wireless measurement to excore pressure transducers (Petrie et al., 2023). After irradiation, the experiment was disassembled in the Irradiated Fuels Examination Laboratory (IFEL) hot cell at Oak Ridge National Laboratory with the intent to recover sensor and dosimetry components, document the as-irradiated condition of the hardware, and investigate possible causes of the sensor behavior observed during irradiation. The postirradiation examination successfully recovered and preserved key WIRE-21 components. After the housing was removed using a milling machine, the internal experiment sections were examined. All eight fiber-optic sensors were recovered, cut, and stored. The silicon carbide thermometry, temperature sensor, pressure sensor, lower spacer, and selected pressure and temperature cable sections were also removed and stored. The metal bellows of the pressure sensor was found to be plastically deformed, indicating that it had been properly pressurized during irradiation and generally behaved as expected. X-ray diffraction analysis of a section of one of the irradiated inductor cores within the pressure sensor was performed and confirmed the presence of phase-pure alpha ferrite (i.e., no unexpected phase transformations). Inductance testing was performed on the irradiated pressure sensor cores using an unirradiated test coil, and DC resistance measurements of the transceiver coils were also performed. The measurements with irradiated inductor cores assembled inside unirradiated coils showed slightly reduced inductance compared to measurements made with unirradiated cores, but the difference was not sufficient to explain the more significant reductions in inductance that were observed in-pile. Therefore, it is suspected that degradation of the inductor coils (specifically the wire wrapping) is responsible for the reduced inductance observed in-pile.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Test Reactor Neutron Dosimetry Report – 174 A & B

Results of neutron dosimetry measurements in ATR for cycle 174 A B are presented. Cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In-Pile Irradiation Induced Defects and the Effect on Thermal Diffusivity of MgO

The effects of neutron irradiation temperature and dose on thermal diffusivity are compared between non-irradiated and in-pile irradiated MgO samples. MgO pellets were irradiated in-pile of the Advanced Test Reactor at Idaho National Laboratory. Samples were irradiated at 623 and 973 K to fast neutron fluences of 1 x 1025 (1.5 dpa) and 2 x 1025 n/m2 (3 dpa). Post irradiation examination included X-ray diffraction, scanning electron microscopy, laser flash thermal diffusivity, and transmission electron microscopy. The radiation induced thermophysical and structural evolution of MgO is reported

T. Moorea, Donald↗

Testing piezoelectric sensors in a nuclear reactor environment

Several Department of Energy Office of Nuclear Energy (DOE-NE) programs, such as the Fuel Cycle Research and Development (FCRD), Advanced Reactor Concepts (ARC), Light Water Reactor Sustainability, and Next Generation Nuclear Power Plants (NGNP), are investigating new fuels, materials, and inspection paradigms for advanced and existing reactors. A key objective of such programs is to understand the performance of these fuels and materials during irradiation. In DOE-NE’s FCRD program, ultrasonic based technology was identified as a key approach that should be pursued to obtain the high-fidelity, high-accuracy data required to characterize the behavior and performance of new candidate fuels and structural materials during irradiation testing. The radiation, high temperatures, and pressure can limit the available tools and characterization methods. In this work piezoelectric transducers capable of making these measurements are developed. Specifically, three piezoelectric sensors (Bismuth Titanate, Aluminum Nitride, and Zinc Oxide) are tested in the Massachusetts Institute of Technology Research reactor to a fast neutron fluence of 8.65x1020 nf/cm2. It is demonstrated that Bismuth Titanate is capable of transduction up to 5 x1020 nf/cm2, Zinc Oxide is capable of transduction up to at least 6.27 x1020 nf/cm2 , and Aluminum Nitride is capable of transduction up to at least 8.65x x1020 nf/cm2.

T. Reinhardt, Brian↗

Development of mesopores in superfine grain graphite neutron-irradiated at high fluence

Microstructural changes induced by neutron irradiation of superfine grain graphite G347A (Tokai Carbon, Japan) were examined by nitrogen adsorption at 77K and by three microscopy techniques (SEM, TEM and FIB-SEM tomography). The specimens were irradiated at doses of up to 30 dpa, covering stages before and after the turnaround fluence at three temperatures (300, 450, 750 °C) of their irradiation envelope. The initial graphite densification at low fluences did not produce any detectable effect in the pore size range (<350 nm) measured by gas adsorption. However, graphite irradiated at high fluences, after turnaround, showed severe structural changes. At all three temperatures and high irradiation fluences, gas adsorption revealed significant increase of the volume of narrow mesopores (<5–20nm) and up to five times increase of BET surface area, both in linear relationship with the relative volume expansion. Analysis of microscopy images showed multiplication of fine macropores (>50 nm) at high irradiation fluences and more structural changes on multiple scales, from nanometers to microns. This work demonstrates the unique ability of gas adsorption techniques to analyze open pores with sizes between sub-nanometer and sub-micron in bulk nuclear graphite, with supporting microscopy results.

I. Contescu, Cristian↗

Searches for New Physics With Muon Conversion at Fermilab and Triboson Production at the LHC

We report on several efforts to search for physics beyond the standard model of particle physics at broad energy scales. The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the muon to electron conversion process, which is suppressed in the Standard Model. Mu2e will be operated at a low energy, yet can probe New Physics at very high mass scales (O(1e3 - 1e4 ) TeV). At high energies, the CMS experiment at the CERN LHC continues to deliver an impressive suite of Standard Model measurements and limits on a variety of New Physics signatures. Mu2e is under construction and slated to collect its first physics data in the coming years. This thesis describes work done during the construction phase of Mu2e and focuses on two critical areas: magnetic field modeling and statistical analysis. We describe a novel method for field modeling which we validate using a simulated dataset representing the expected magnetic field in the Detector Solenoid. This method blends a standard least-squares fitting technique that utilizes physically motivated analytical model functions with a novel physics informed network that is constructed to obey Maxwell’s equations. We show the technique can model the field with an accuracy of 10−7 despite the presence of injected noise in the pseudo-measurements at the 10−5 level. We then present preliminary results of the calibration of 3D Hall probes at the sub-10−4 level. These probes will be used to directly measure the Mu2e Detector Solenoid magnetic field on a sparse grid; these measurements serve as the input to the field model fitting. Finally, we describe the first implementation of both an unbinned shape analysis and a Bayesian interpretation applied to Mu2e pseudo-data. Up to 20% tighter limits can be set by the shape analysis compared to a standard cut & count analysis. The AlCap experiment collected data at PSI in 2015 to measure several important quantities related to nuclear muon capture on an aluminum target, which is a significant background process for Mu2e. The neutron emission from muon capture can introduce background hits in the Mu2e detectors and can increase radiation damage in various elements of the apparatus. We present measurements of the neutron group fluence and mean neutron multiplicity for muon capture on aluminum nuclei. Finally, we discuss an analysis of triboson production at CMS using an Effective Field Theory framework. Standard Model triboson production, which was first observed at CMS in 2020, has a relatively small cross section and provides direct access to both anomalous triple gauge couplings and quartic gauge couplings. These couplings, interpreted in the Standard Model Effective Field Theory, are studied in the present work. We target the boosted regime where the background rate is low and yields are enhanced when dimension-6 and dimension-8 Wilson coefficients are non-zero. We do not observe an excess in the data and therefore set bounds on the Wilson coefficients. For dimension-6 coefficients the tightest observed (expected) bounds are set on cW /Λ2 where Λ is the mass scale of new physics; the bounds are [−0.13, 0.12] TeV−2 ([−0.12, 0.12] TeV−2 ) at 95% CL. The tightest bounds in dimension-8 are set on fT,0 / Λ4 ; the observed (expected) bounds at 95% CL are [−0.63, 0.69] TeV−4 ([−0.54, 0.62] TeV−4 ). Additional results are presented which include scenarios where multiple Wilson coefficients are non-zero, the application of signal model clipping to address unitarity violation in Effective Field Theories, and a novel template fit developed for easier reinterpretation of our results.

Kampa, Cole Erik [Northwestern U. (main)] (ORCID:0↗

AGC-4 As-Run Uncertainty Analysis

The concept of measuring neutron flux (or fluence rate) with activation foils has existed since the late 1940s and is a well-used methodology. Activation foils are selected for their unique isotopic cross sections that create reaction products with desirable properties: relatively simple radioactive decay scheme, measurable quantities of gamma-rays or betas, and half-lives appropriate for the irradiation and decay durations of the experiment. The activation materials, deemed flux wires, fluence wires, dosimeters, or flux foils, are fabricated to have a mass appropriate for the irradiation as well so the measurement using a radiation detector following the irradiation is sufficient but not overwhelming in terms of total activity. Activation measurement results are expressed in terms of reaction rate, which can then be used to “adjust” the neutron spectrum. The Advanced Graphite Creep (AGC)-4 experiment contained 26 flux wire packages, each containing an iron and a niobium wire inside a vanadium capsule. For all stackup positions, the value of fast to thermal neutrons is higher than expected, but the total neutron fluence is near the predicted value of ~2 x 1022 n/cm2. As compared to the predicted neutron spectrum, there are four takeaways in the results as compared to the predicted ATR irradiation: 1) Additional fast (fission) neutrons present, 2) Spectrum hardening due to temperature, 3) Spectrum hardening due to container attenuation, 4) Total neutron fluence is close to predicted values. Since the neutron energy spectrum is a key parameter when attributing neutron damage in materials, the adjusted energy-dependent spectrum and the total neutron fluence results from the dosimeters can be incorporated for future calculations.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Structural characterization of neutron irradiated hexagonal boron-10 nitride-15 single crystals

The negatively charged boron vacancy ($V$$^{–}_{⁠B}$⁠) in hexagonal boron nitride (hBN) is a promising quantum defect that can be used to sense pressure, temperature, and magnetic field with high spatial resolution. hBN enriched with the boron-10 and nitrogen-15 isotopes, denoted h 10 B 15 N, has good contrast and coherence for quantum sensing because nitrogen-15 has nuclear spin (1/2), reducing hyperfine interactions. Boron vacancies can be generated by neutron irradiation, which causes the transmutation of the boron-10 isotope to lithium-7. In this study, the ancillary structural, compositional, and mechanical properties of h 10 B 15 N crystals that have been subjected to neutron irradiation fluences from 1.4 × 10 16 to 8.4 × 10 17 n/cm 2 were thoroughly characterized. Besides creating $V$$^{–}_{⁠B}$⁠, the process also induces other defects that generate strain in the crystal lattice. In turn, the mechanical properties of these crystals change drastically. Investigated here are the visual changes, lattice integrity, composition, crystal strain, and elastic constants (C 33 and C 66 ) to assess how these characteristics change as a function of neutron fluence.

36 MATERIALS SCIENCE↗

Fabrication and Testing of Micro Flux Monitors in the High Flux Isotope Reactor

Neutron dosimetry is a critical technique to measure the neutron flux, fluence, and energy spectrum of nuclear reactors and can be used to indicate fuel reloading, high-power operations, or changes in cycle length. This work presents results of a novel device named the micro flux monitor, which is a miniaturized neutron dosimeter made from small quantities (100s of nanograms) of Ti, Al, Ni, and Au metals deposited on Si and high-purity fused silica substrates using standard semiconductor fabrication techniques. Approximately 1,250 of these devices were produced, and 40 were irradiated in the pneumatic tube facility of the Neutron Activation Analysis Laboratory at the High Flux Isotope Reactor. Testing demonstrated that dosimeter metals can be deposited predictably and repeatedly in multiple geometries, including as quick response (QR) codes. Neutron flux measurements with these devices were within 3% of measurements made using standard flux monitors, demonstrating the efficacy of these devices. Devices were also tested at 500°C under a N2 atmosphere and showed minimal degradation, suggesting they could be deployed for neutron dosimetry measurements in high-temperature advanced reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effects of drive pulse shape on graded metal pushered single shell capsule implosions on the National Ignition Facility

Graded metal pushered single shells (PSS) are a viable alternative to low-Z capsules (Z is the atomic number) for indirect drive inertial confinement fusion implosions due to enhanced core tamping and radiation trapping, but they can be compromised by the pusher mixing with the fuel. We compare 2-shock and 3-shock laser pulses for Be/Cr PSS capsules filled with deuterium–tritium gas fuel at 6 mg/cc density. 1D radiation-hydrodynamic simulations predict higher core compression and, hence, ∼2× higher fusion yield for the 3-shock drive than for 2-shock. Nevertheless, we observe similar core ion temperatures and fusion yields for both drives. The implosion burn duration is 25% shorter and the core volume is ∼2.5× smaller for the 3-shock drive than for 2-shock, consistent with a higher compression. 1D LASNEX mix simulations using a buoyancy-drag model matching the measured yields also agree with the observed core sizes and burn durations and suggest ∼40% and ∼70% yield degradations for 2-shock and 3-shock drives due to hydrodynamic instabilities and atomic mix at the pusher–fuel interface. At the same time, 2D HYDRA simulations show that mid-mode (2–250) instability degradations are negligible for the 2-shock implosion (9%) and significant (45%) for 3-shock. Subtracting these from the 1D mix simulations, we infer similar degradations from high-mode instabilities and atomic mix for both drives. Due to its robustness to mid-mode instabilities, future pusher–gas mix studies will use the 2-shock drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Capsule Design and Preparation for YH x Specimen Irradiation in the High Flux Isotope Reactor

Advanced nuclear systems for terrestrial microreactors and space applications require moderator materials with high thermal stability, hydrogen retention, and efficient neutron moderation. Yttrium hydride (YH x ) is a promising candidate, but its irradiation performance and hydrogen stability remain insufficiently understood. To address this, Oak Ridge National Laboratory (ORNL) and Los Alamos National Laboratory, supported by the US Department of Energy’s Nuclear Science User Facilities program, have initiated an irradiation campaign in ORNL’s High Flux Isotope Reactor. The experiment employs six irradiation capsules containing YH x specimens (H/Y ≈ 1.9) designed for three target temperatures (300°C, 400°C, and 500°C) and two distinct neutron fast fluence levels. This report documents the irradiation test matrix, capsule design, specimen precharacterization, and experiment readiness for insertion. Planned postirradiation examinations will provide new insights into hydrogen retention and microstructural stability, advancing the understanding of YH x as a moderator for compact reactor applications.

36 MATERIALS SCIENCE↗

Capsule Design and Preparation for YH x Specimen Irradiation in the High Flux Isotope Reactor

Advanced nuclear systems for terrestrial microreactors and space applications require moderator materials with high thermal stability, hydrogen retention, and efficient neutron moderation. Yttrium hydride (YH x ) is a promising candidate, but its irradiation performance and hydrogen stability remain insufficiently understood. To address this, Oak Ridge National Laboratory (ORNL) and Los Alamos National Laboratory, supported by the US Department of Energy’s Nuclear Science User Facilities program, have initiated an irradiation campaign in ORNL’s High Flux Isotope Reactor. The experiment employs six irradiation capsules containing YH x specimens (H/Y ≈ 1.9) designed for three target temperatures (300°C, 400°C, and 500°C) and two distinct neutron fast fluence levels. This report documents the irradiation test matrix, capsule design, specimen precharacterization, and experiment readiness for insertion. Planned postirradiation examinations will provide new insights into hydrogen retention and microstructural stability, advancing the understanding of YHx as a moderator for compact reactor applications.

36 MATERIALS SCIENCE↗

Fusion Neutron Generator

The proposed code, named FROG (Fusion neutron Generator) is built upon the open-source particle transport Monte Carlo toolkit Geant4. Geant4 provides C++ classes that can be leveraged to build application-specific codes dealing with the transport of particles through matter. Geant4-based codes are applied in high-energy particle physics experiments, medical applications, shielding, and space applications for example. The FROG code allows the user to define the geometry of a neutron converter device shaped as a hollow cylinder, where a neutron breeding material such as lithium deuteride (LiD) is cladded by two concentric cylinders. Such neutron converter is then placed inside a regular nuclear fission reactor, where thermal neutrons will react with the neutron breeder material (typically, Lithium 6), and through a series of reactions, will generate high-energy neutrons – neutrons whose kinetic energy are around 14 MeV. The hollowed central portion can hold a specimen that will be bombarded by high-energy neutrons created inside the neutron breeding material. Figuratively speaking, this type of device transforms neutrons from thermal (~0.625 eV) to fusion (~14 MeV) energies and is sometimes termed “fusion-to-thermal neutron converters” in the literature. The code consists of C++ source file compiled and linked to generate an executable. The user can select the dimensions of the converter (radius, length, and thickness of the breeder material), the breeder material type, the cladding material, and the specimen material that will be activated or irradiated. As input, the neutron flux for a specific location inside a reactor, for instance, positions in ATR, is required. As output, the code predicts the number of high-energy neutrons produced, the total neutron flux and fluence as well as its detailed spectrum. The physics involved in such device is very complex, as it requires modeling neutron transport, light-ion (tritons) transport, as well as fusion reactions. The Geant4 toolkit provides the required physical models.

Martin, NicholasP. [Idaho National Laboratory (INL↗