Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Impact of Glass Irradiation on Laser-Induced Breakdown Spectroscopy Data Analysis

Increased absorption of optical materials arising from exposure to ionizing radiation must be accounted for to accurately analyze laser-induced breakdown spectroscopy (LIBS) data retrieved from high-radiation environments. We evaluate this effect on two examples that mimic the diagnostics placed within novel nuclear reactor designs. The analysis is performed on LIBS data measured with 1% Xe gas in an ambient He environment and 1% Eu in a molten LiCl-KCl matrix, along with the measured optical absorption from the gamma- and neutron-irradiated low-OH fused silica and sapphire glasses. Significant changes in the number of laser shots required to reach a 3σ detection level are observed for the Eu data, increasing by two orders of magnitude after exposure to a 1.7 × 1017 n/cm2 neutron fluence. For all cases examined, the spectral dependence of absorption results in the introduction of systematic errors. Moreover, if lines from different spectral regions are used to create Boltzmann plots, this attenuation leads to statistically significant changes in the temperatures calculated from the Xe II lines and Eu II lines, lowering them from 8000 ± 610 K to 6900 ± 810 K and from 15,800 ± 400 K to 7200 ± 800 K, respectively, for exposure to the 1.7 × 1017 n/cm2 fluence. The temperature range required for a 95% confidence interval for the calculated temperature is also broadened. In the case of measuring the Xe spectrum, these effects may be mitigated using only the longer-wavelength spectral region, where radiation attenuation is relatively small, or through analysis using the iterative Saha–Boltzmann method.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fast Neutron Irradiation of a Multichannel JFET-Based Optical Encoder

Modern electrical components are susceptible to damage from high levels of radiation and extreme temperatures found near reactors in terrestrial nuclear power plants and in aerospace applications. Radiation-hardened electronics are being developed, largely for the aerospace industry, but they sometimes rely on application-specific, small-batch semiconductor fabrication processes. These processes tend to be prohibitively expensive to develop and maintain outside major industrial facilities or governmental agencies. Recently, commercially available, nonradiation-rated junction-gate field-effect transistors (JFETs) were shown to maintain their functionality at gamma doses exceeding 1 MGy, suggesting that nonrated, commercially available electrical components could be used to develop systems that are tolerant to ionizing radiation. However, gamma ray survival is not indicative of neutron dose survival, and few studies characterize JFETs under neutron irradiation. To address this knowledge gap, a JFET-based analog multiplexer and optical pulsewidth modulation (PWM) encoder was developed and irradiated using a 252 Cf source to 1.6×10 13 n/cm 2 . The multiplexed optical encoder (MOE) system maintained functionality throughout testing and showed little evidence of radiation effects. These results indicate that circuitry tolerant to fast neutron damage can be developed using low-cost, nonradiation-rated, commercially available JFETs, which could provide a lower production cost alternative to specialized semiconductor processes when designing and building electronics better able to survive neutron irradiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantification of Sub-Pixel Dynamics in High-Speed Neutron Imaging

The high penetration depth of neutrons through many metals and other common materials makes neutron imaging an attractive method for non-destructively probing the internal structure and dynamics of objects or systems that may not be accessible by conventional means, such as X-ray or optical imaging. While neutron imaging has been demonstrated to achieve a spatial resolution below 10 μm and temporal resolution below 10 μs, the relatively low flux of neutron sources and the limitations of existing neutron detectors have, until now, dictated that these cannot be achieved simultaneously, which substantially restricts the applicability of neutron imaging to many fields of research that could otherwise benefit from its unique capabilities. In this work, we present an attenuation modeling approach to the quantification of sub-pixel dynamics in cyclic ensemble neutron image sequences of an automotive gasoline direct injector at a 5 μs time scale with a spatial noise floor in the order of 5 μm.

47 OTHER INSTRUMENTATION↗

Demonstration of the neutron tracking capability of NEXT array in time-of-flight measurements to improve energy resolution

Precise neutron-energy measurements are required to probe the nuclear structure effects of neutron-rich nuclei, where β-delayed neutron emission becomes a dominant decay mode. The Neutron dEtector with Xn Tracking (NEXT) array has been designed and constructed to measure β-delayed neutrons with better energy resolution. The new design localizes the neutron interaction position by optically segmenting the detector along the direction of the neutron flight path, reducing the associated uncertainties in the neutron time-of-flight measurements. This significantly improves the energy resolution without losing the necessary detection efficiency. The proof-of-principle and efficiency measurements showed promising results. Herein, this article details the implementation of the neutron tracking capability of NEXT array in time-of-flight measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Elevated Electron Temperature Coincident with Observed Fusion Reactions in a Sheared-Flow-Stabilized Z Pinch

The sheared-flow-stabilized Z pinch concept has been studied extensively and is able to produce fusion-relevant plasma parameters along with neutron production over several microseconds. In this work, we present elevated electron temperature results spatially and temporally coincident with the plasma neutron source. An optical Thomson scattering apparatus designed for the FuZE device measures temperatures in the range of 1–3 keV on the axis of the device, 20 cm downstream of the nose cone. The 17-fiber system measures the radial profiles of the electron temperature. Scanning the laser time with respect to the neutron pulse time over a series of discharges allows the reconstruction of the T e temporal response, confirming that the electron temperature peaks simultaneously with the neutron output, as well as the pinch current and inductive voltage generated within the plasma. Comparison to spectroscopic ion temperature measurements suggests a plasma in thermal equilibrium. The elevated T e confirms the presence of a plasma assembled on axis, and indicates limited radiative losses, demonstrating a basis for scaling this device toward net gain fusion conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical transmission and dimensional stability of single-crystal sapphire after high-dose neutron irradiation at various temperatures up to 688 °C

The use of single-crystal sapphire optical fibers has been considered to extend fiber-optic sensing to the extreme temperature (>1000 °C) environments encountered in nuclear applications. However, before these sapphire fiber–based sensors can be deployed, their optical transmission and dimensional stability (which impacts drift of some sensors) must be characterized under representative testing conditions. Data regarding the optical transmission of sapphire following high-dose neutron irradiation at temperatures >100 °C is extremely limited. This work provides measurements of optical density (i.e., attenuation) and directional dimensional changes in bulk single-crystal sapphire materials irradiated to a fast neutron fluence of 2.4 × 10 21 n/cm 2 (3.5 displacements per atom) at temperatures ranging from 95 to 688 °C. Optical density measured after irradiation at 95 and 298 °C showed ultraviolet and visible absorption bands corresponding to known defect centers and temperature trends that were generally consistent with previous ex situ and in situ measurements made at much lower neutron fluence. However, optical density measured after irradiation at 688 °C was as much as two orders of magnitude higher, indicating that the fundamental mechanism for radiation-induced attenuation changes at this irradiation temperature. Additional analysis and comparison with previous works suggest that the attenuation may result from void formation, leading to increased Rayleigh scattering losses in the material and increased swelling that would also result in drift of Bragg grating-based sensors in sapphire fibers. These results pose serious questions regarding the feasibility of sapphire fiber–based sensors for high-temperature nuclear applications.

36 MATERIALS SCIENCE↗

Thermal deflection in neutron scattering sample environments at Oak Ridge National Laboratory

The neutron sources at Oak Ridge National Laboratory use a wide suite of sample environment equipment to deliver extreme conditions for a number of experiments. Much of this instrumentation focuses on extremes of temperature, such as cryostats, closed-cycle refrigerators in both low and high temperature configurations, and radiant heating furnaces. When the temperature is controlled across a large range, thermal deflection effects can notably move the sample and affect its alignment in the beam. Here, we combine these sample environments with neutron imaging and machine vision to determine the motion of a representative sample with respect to the neutron beam. We find vertical sample displacement on the order of 1–2 mm and horizontal displacement that varies from near-negligible to 1.2 mm. While these deflections are not relevant for some of the beamlines at the first target station at the spallation neutron source and the high flux isotope reactor, they will become critical for upcoming instrumentation at the second target station, as well as any instruments targeting sub-mm samples, as neutron sources and optics evolve to smaller and more focused beams. We discuss mitigation protocols and potential modifications to the environment to minimize the effect of misalignment due to thermal deflection.

47 OTHER INSTRUMENTATION↗

Grating-Based Imaging-Scattering with Portable Neutron Generator

Company: Adelphi Technology, Inc. Title: Grating-Based Imaging-Scattering with Portable Neutron Generator PI: Dr. Jay Theodore Cremer, Jr. Topic: 26a Statement of the problem or situation that is being addressed. Successful plant growth depends upon an efficient and robust root system. The plant root is part of a larger system of water and microbial flows in the soil system. While much effort has been exerted to develop an imaging system for water, microbes, and roots, the problem is challenging, and no widely accepted imaging method currently exists. The optical solutions use a highly modified soil system. X-ray imaging methods are insensitive to the soft tissues in the presence of sand. Thermal neutron imaging has been often tested, but found inadequate, due to limited access and low image resolution. This project will develop a new strategy for neutron imaging of plant/soil systems. The project will allow long duration experiments in greenhouse environments and increase the image information content to the micron scale. General statement of how this problem is being addressed. Portable, rugged thermal and fast neutron sources are being developed where portable means a two-soldier team can carry the source and power unit to survey rough terrain for explosives. In the past decade, microfabrication of X-ray and thermal/cold neutron optics has opened a new imaging strategy. The standard transmission image is now supplemented with simultaneous acquisition of a phase contrast image and an image revealing scattering features. In materials science, the interferometric neutron scattering image has been used to detect early crack formation in stressed additive manufacturing test samples. The detection requires sensitivity to scattering features at the 1-micron scale. By addition of our proposed grating-optic to Adelphi Technology’s radiographic/tomographic imaging system, which is based on portable thermal neutron source, the resulting thermal neutron scatter image of the plant/soil system, will reveal details at 1-micron. Commercial Applications and Other Benefits Neutron interferometry imaging has greater penetration through large metal components compared to industrial X-ray imaging. The low-cost, large area optics developed for greenhouse applications, combined with the robust, portable neutron generator, can then be marketed as a system for inspection of additive manufactured components. In the aerospace industry, all freshly printed components are validated with X-ray CT. Scheduled maintenance again requires X-ray CT as the ability to predict aerospace component lifetime does not yet exist. Large aerospace components are only partially observed with X-ray imaging. Key Words Neutron radiography/tomography, grating interferometry, thermal neutron generator imaging, plant root and soil imaging, rhizosphere imaging, deployable neutron imaging systems Summary for Members of Congress A rugged, portable source of thermal neutrons is adapted for neutron interferometry imaging with the addition of low-cost, 3D printed optics. The first application of our proposed deployable, compact thermal neutron generator imaging system, using a grating optic, is plant root/soil science in greenhouse settings and agricultural laboratories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Scientific Case for Concurrent Neutron and X-ray Scattering and Spectroscopy

The interrogation of materials with X-rays or neutrons to determine the structure, energetics, and dynamics of materials is fundamental to advancing materials' physical and chemical science and developing innovative material technologies. A transcending challenge in developing novel materials is that progress hinges on understanding the structure and dynamics across multiple time and length scales in complex materials that feature multiple components, interfaces, and compositions. Despite the ever-growing demands on materials’ characterization, existing approaches are almost exclusively based on isolated X-ray or neutron scattering, i.e., an approach commensurate with the more narrowly defined needs of fifty years ago. A three-day workshop sponsored by the U.S. National Science Foundation (NSF) analyzed the demand for concurrent neutron and X-ray (NeX) experiments. It was held at the Spring Hill Suites, San Jose, California, from June 2 to 4, 2022. In this workshop, 70 national and international experts ascertained the crucial need to establish NeX capabilities to advance the science of complex materials and systems in the US. Here, we illustrate the need for NeX scattering and spectroscopy experiments by showcasing examples that span areas as diverse as biomaterials, energy science, soft matter, and nanomaterials. To provide NeX capability will require new instrumentation that enables concurrent experiments. Affected areas include chemistry, soft matter, quantum materials, pure and applied chemistry, bioscience, geoscience, and applied materials. NeX benefits research outcomes due to the complementarity of the two techniques, which is essential for better model refinement. While joint refinement of data from separate neutron and X-ray experiments is critical to avoid ambiguities, especially in multiphase-multicomponent materials, concurrent experiments overcome scientific and technical barriers associated with single measurements, separated by location and, thus, time. Among all the examples, these factors introduce uncertainties in the results that complicate data analysis. [1,2] [3] While models are strongly sample-dependent, the principles of joint refinement are generally applicable to these disciplines, including the development of advanced parameterization, modeling, and analysis techniques that also consider the temporal and spatial resolutions of the two methods, leading to unambiguous data interpretation. Solutions for technical barriers must be found to realize NeX experiments, including developing robust sample environments that meet the optical requirements of neutrons and X-rays.

36 MATERIALS SCIENCE↗

Anisotropic Excitons Reveal Local Spin Chain Directions in a van der Waals Antiferromagnet

A long‐standing pursuit in materials science is to identify suitable magnetic semiconductors for integrated information storage, processing, and transfer. Van der Waals magnets have brought forth new material candidates for this purpose. Recently, sharp exciton resonances in antiferromagnet NiPS 3 have been reported to correlate with magnetic order, that is, the exciton photoluminescence intensity diminishes above the Néel temperature. Here, it is found that the polarization of maximal exciton emission rotates locally, revealing three possible spin chain directions. This discovery establishes a new understanding of the antiferromagnet order hidden in previous neutron scattering and optical experiments. Furthermore, defect‐bound states are suggested as an alternative exciton formation mechanism that has yet to be explored in NiPS 3 . The supporting evidence includes chemical analysis, excitation power, and thickness dependent photoluminescence and first‐principles calculations. This mechanism for exciton formation is also consistent with the presence of strong phonon side bands. This study shows that anisotropic exciton photoluminescence can be used to read out local spin chain directions in antiferromagnets and realize multi‐functional devices via spin‐photon transduction.

36 MATERIALS SCIENCE↗

Physics prospects with MeV neutrino-argon charged current interactions using enhanced photon detection in future LArTPCs

Here, we investigate MeV-scale electron neutrino charged current interactions in a liquid argon time projection chamber (LArTPC) equipped with an enhanced photon detection system. Using simulations of deposited energy in charge and light calorimetry, we explore the potential for dual calorimetric neutrino energy reconstruction. We found energy reconstruction based on light-only calorimetry has a better resolution than combined charge and light calorimetry when hadrons are produced in these events. Meanwhile, enhanced light detection offers improved nanosecond timing resolution and broad optical coverage, enabling neutron tagging and identification of delayed low-energy gamma emissions. These advancements open new avenues in low-energy neutrino physics in next-generation LArTPCs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The right conditions for high-precision dynamic temperature and heat capacity measurement via pyrometry and conductivity

The pursuit of accurate bulk temperature T under extreme conditions has been a long-standing goal of the high pressure science community, complicated by a lack of data to inform models. To reach these extremely high-pressure, high-temperature (high P − T) conditions, a combination of dynamic and heated static experiments (e.g., diamond or gem anvil cel experiments) are used. For example, in a diamond anvil cell (DAC) experiment, a sample placed in the DAC is first pressurized. Following pressurization, the sample T is increased either by heating the entire DAC (usually using resistive heating, and limited to ∼1000K) or by applying intense laser power to the sample surfaces. In a dynamic experiment, the process of pressurizing the sample also heats it. In the case of shock physics experiments, such heating is substantial, easily reaching thousands of Kelvin; in our work we have seen T ∼17000K. Most methods of measuring temperature at ambient are not compatible with experiments under these high-pressure, high-temperature conditions: thermocouples break, melt, or have conductivity properties that differ from ambient where they are calibrated; thermometers would melt; both are too slow. As a result most methods are based on non-contact techniques such as x-ray diffraction broadening, neutron scattering, or optical methods. Of these, optical methods using the visible and near-infrared region of the spectrum are the most commonly used as the sources and detectors are readily available. In the case of optical methods the optical depth, and therefore the measurement location, is limited to the surface. When a window or anvil material is used, heat flows from the sample into the window/anvil. Likewise, if the sample undergoes a change in thermodynamic state, such as expansion upon release, different T may be expected. As a result, the surface or apparent temperature T app measurement will differ from the bulk or interior temperature that is desired. This surface measurement must be related to the bulk measurement using thermal transport models and material models. While it is tempting to conclude that one should just use x-ray methods that directly probe the interior, even these methods have been shown to depend on thermal transport and material models. Regardless of the method used to create the high P − T condition, therefore, we must understand the role of thermal transport and material models upon our interpretation of the T measurement, as well as the errors and uncertainties associated with the choice of models used in the analysis. This is a substantial area of research and this paper is by no means a complete survey of the relevant sources of uncertainty. For example, we have yet to begin to address alternate transport models in a detailed manner (e.g., Tan-Ahrens), or the many models that use additional layers to approximate melting, turbulence, or epitaxial phenomena). Likewise, we have not explored the impact upon uncertainty of thermal models that use temperature-dependent thermal transport coefficients, or the wide range of material models that can be applied. Instead, this paper focuses on using one simple model, the Urtiew-Grover model, to understand the sources of error in T measurement so that we may identify how best to focus future research efforts to return the best improvements and avoid working on over-optimizing a single type of measurement. To this end, we work through some of the best and worst case scenarios for T measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Retractable Sensor for Reactor Experiments

This presentation is to orient a mechanical or nuclear engineering senior design team so that they can help solve an instrumentation problem found in high power test reactors. Test reactors such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory are used to irradiate nuclear fuels and materials to evaluate performance after high levels of exposure to a reactor in-pile environment. The purpose of the experiments is to determine property changes as the materials or fuels are bombarded with fast neutrons (and thermal (slow) neutrons as well). Typically, the irradiation must take place at a very specific temperature. Sometimes other parameters are monitored as well as properties such as creep, or gas composition, etc. However, the fast neutrons cause changes in not only the materials, but also in the transducers that are placed in the neutron flux, e.g., thermocouples or optical fibers. This task will be limited to considering temperature measurements. Thermocouples experience decalibration from not only the neutron flux, but also from the very high temperatures that are sometimes measured. Optical fibers darken in a neutron or gamma flux. However, it takes quite a few hours, or days for these changes to manifest. High power test reactors typically run at a constant power and so the temperature in an experiment is fairly stable over time. Because the changes are typically very slow, even a single temperature measurement per day, would provide 95% of a perfect data set. The basic concept of this effort is to push a very small diameter thermocouple or optical fiber into the location to be measured, leave it for 30 seconds or so for it to come to equilibrium, and transmit the signal, and then pull it up and away from the high neutron flux and high temperature region. The distance the thermocouple or fiber would need to move is on the order of 50 – 100 cm. By doing this, the thermocouple junction or optical fiber would spend only a few hours in the high flux/high temperature environment over the life of the irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spot size measurement of a deuterium–tritium dense plasma focus using neutron radiography

Neutron radiography is a technique uniquely suited to applications in nuclear diagnostics, non-destructive testing, and subcritical experiments. The spatial resolution of neutron radiographs is degraded by optical blur in the imaging system and the neutron source size, where the ideal source is point-like to optimize the point-spread function. A potential neutron source for radiography is the dense plasma focus (DPF), a coaxial Z-pinch that produces thermonuclear and beam-target neutrons. To assess if the source size is suitable for radiography, a neutron imaging system was used to measure the source size of the 4 MA Sodium DPF at the Nevada National Security Site operating with deuterium–tritium gas-fill. The source size was measured using the edge-spread function of tungsten objects, each having a rolled (convex) edge. The spot size was found to be 7–12 mm full-width at half-max (FWHM) assuming a Gaussian source, though comparison is presented for Lorentzian and Bennett distributions. The average FWHM was found to be 8.6 ± 1.2 mm vertically and 10.8 ± 1.2 mm horizontally with respect to the image plane, averaging over varied edges and alignments. The results were sensitive to source alignment and edge metrology, which introduced notable uncertainties. These results are consistent with separate experimental measurements as well as magnetohydrodynamics simulations of this DPF, which suggest that neutron production can originate from pinches ∼5–7 mm off-axis. These results suggest that the DPF should be used for radiography at low magnification (M < 1) where spot size does not dominate spatial blur.

47 OTHER INSTRUMENTATION↗

MENUS—Materials engineering by neutron scattering

Materials engineering by neutron scattering (MENUS) at the second target station will be a transformational high-flux, versatile, multiscale materials engineering diffraction beamline with unprecedented new capabilities for the study of complex materials and structures. It will support both fundamental and applied materials research in a broad range of fields. MENUS will combine unprecedented long-wavelength neutron flux and unique detector coverage to enable real-time studies of complex structural and functional materials under external stimuli. The incorporated small angle neutron scattering and transmission/imaging capabilities will extend its sensitivity to larger length scales and higher spatial resolution. Multimodal MENUS will provide crystallographic and microstructure data to the materials science and engineering community to understand lattice strain/phase transition/microstructure/texture evolution in three orthogonal directions in complex material systems under combined extreme applied conditions. Finally, the capabilities of MENUS will open new scientific opportunities and meet the research needs for science challenges to enable studies of a range of phenomena and answer the key questions in material design/exploration, advanced material processing, transformative manufacturing, and material operations of national impacts in our daily life.

47 OTHER INSTRUMENTATION↗