Search NASASearch

SEARCH · Search NASA

Results for “NiCd rechargeable battery Taguchi Methods application L16 orthogonal array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

878 records · Page 4

Optimal Battery Charging for Damage Mitigation

Our control philosophy is to charge the NiH2 cell in such a way that the damage incurred during the charging period is minimized, thus extending its cycle life. This requires nonlinear dynamic model of NiH2 cell and a damage rate model. We must do this first. This control philosophy is generally considered damage mitigating control or life-extending control. This presentation covers how NiH2 cells function, electrode behavior, an essentialized model, damage mechanisms for NiH2 batteries, battery continuum damage modeling, and battery life models. The presentation includes graphs and a chart illustrating how charging a NiH2 battery with different voltages and currents affects damages the battery and affects its life. The presentation concludes with diagrams of control system architectures for tracking battery recharging.

Hartley, Tom T.

Space Electrical Power

The objectives and achievements of the development program for space electrical power systems are discussed. Power requirements for various space projects and products of power development research are considered. Research on the radiation-resistant n-p solar cell, thin-film solar cells, and rechargeable batteries is outlined. The development of Snap-8 is also discussed.

Power

The NASA Inductrack Model Rocket Launcher at the Lawrence Livermore National Laboratory

The Inductrack magnetic levitation system, developed at the Lawrence Livermore National Laboratory, is being studied for its possible use for launching rockets. Under NASA sponsorship, a small model system is being constructed at the Laboratory to pursue key technical aspects of this proposed application. The Inductrack is a passive magnetic levitation system employing special arrays of high-field permanent magnets (Halbach arrays) on the levitating carrier, moving above a "track" consisting of a close-packed array of shorted coils with which are interleaved with special drive coils. Halbach arrays produce a strong spatially periodic magnetic field on the front surface of the arrays, while canceling the field on their back surface. Relative motion between the Halbach arrays and the track coils induces currents in those coils. These currents levitate the carrier cart by interacting with the horizontal component of the magnetic field. Pulsed currents in the drive coils, synchronized with the motion of the carrier, interact with the vertical component of the magnetic field to provide acceleration forces. Motional stability, including resistance to both vertical and lateral aerodynamic forces, is provided by having Halbach arrays that interact with both the upper and the lower sides of the track coils. In its completed form the model system that is under construction will have a track approximately 100 meters in length along which the carrier cart will be propelled up to peak speeds of Mach 0.4 to 0.5 before being decelerated. Preliminary studies of the parameters of a full-scale system have also been made. These studies address the problems of scale-up, including means to simplify the track construction and to reduce the cost of the pulsed-power systems needed for propulsion.

L S Tung

Layout and Cabling Considerations for a Large Communications Antenna Array

Layout considerations for a large deep space communications antenna array are discussed. A novel fractal geometry for the antenna layout is described that provides optimal packing of antenna elements, efficient cable routing, and logical division of the array into identical sub-arrays.

R T Logan, Jr.

Solar Array Automation Limitations

Significant progress in the automation of the spacecraft electrical power systems has been made within the past few years. This is especially important with the development of the space station and the increasing demand on the electrical power systems for future satellites. The key element of the spacecraft power system, the solar arrays which supply the power, will have to grow to supply many tens of kilowatts of power within the next twenty years. This growth will be accompanied by the problems associated with large distributed power systems. The growth of the arrays, the on-array management problems and potential solutions to array degradation or failure are discussed. Multilowatt arrays for unmanned spacecraft with comments on the implications of array degradation for manned spacecraft are discussed.

Terry M Trumble

Solvent-Free Preparation of High Energy, Binder-Free Electrodes Enabled by Dry Compressible Holey Graphene

Graphene is an atomically thick sheet consisting of a graphitic carbon network with excellent mechanical strength, electrical and thermal conductivity, and chemical stability. Holey graphene, a structural derivative of graphene, has an array of through-the-thickness holes across the lateral surface of the nanosheet. The presence of these holes has minimal detrimental effect on the graphene properties and leads to enhanced performance in applications such as electronics, sensors, and energy storage. For example, these holes allow more facile cross-plane ion and gas transport than intact graphene, making holey graphene an ideal electrode material for electrochemical energy storage. This presentation will focus on the ability of holey graphene to be compression molded into robust articles or architectures under solvent-free conditions without the need for potentially parasitic binders. The unique dry compressibility of holey graphene has enabled facile fabrication of high mass loading electrodes with both high density and high porosity, which have found use in supercapacitors and various high-energy battery systems such as lithium-oxygen, lithium-sulfur, and lithium-selenium batteries.

Yi Lin

Modular Battery Charge Controller

A new approach to masterless, distributed, digital-charge control for batteries requiring charge control has been developed and implemented. This approach is required in battery chemistries that need cell-level charge control for safety and is characterized by the use of one controller per cell, resulting in redundant sensors for critical components, such as voltage, temperature, and current. The charge controllers in a given battery interact in a masterless fashion for the purpose of cell balancing, charge control, and state-of-charge estimation. This makes the battery system invariably fault-tolerant. The solution to the single-fault failure, due to the use of a single charge controller (CC), was solved by implementing one CC per cell and linking them via an isolated communication bus [e.g., controller area network (CAN)] in a masterless fashion so that the failure of one or more CCs will not impact the remaining functional CCs. Each micro-controller-based CC digitizes the cell voltage (V(sub cell)), two cell temperatures, and the voltage across the switch (V); the latter variable is used in conjunction with V(sub cell) to estimate the bypass current for a given bypass resistor. Furthermore, CC1 digitizes the battery current (I1) and battery voltage (V(sub batt) and CC5 digitizes a second battery current (I2). As a result, redundant readings are taken for temperature, battery current, and battery voltage through the summation of the individual cell voltages given that each CC knows the voltage of the other cells. For the purpose of cell balancing, each CC periodically and independently transmits its cell voltage and stores the received cell voltage of the other cells in an array. The position in the array depends on the identifier (ID) of the transmitting CC. After eight cell voltage receptions, the array is checked to see if one or more cells did not transmit. If one or more transmissions are missing, the missing cell(s) is (are) eliminated from cell-balancing calculations. The cell-balancing algorithm is based on the error between the cell s voltage and the other cells and is categorized into four zones of operation. The algorithm is executed every second and, if cell balancing is activated, the error variable is set to a negative low value. The largest error between the cell and the other cells is found and the zone of operation determined. If the error is zero or negative, then the cell is at the lowest voltage and no balancing action is needed. If the error is less than a predetermined negative value, a Cell Bad Flag is set. If the error is positive, then cell balancing is needed, but a hysteretic zone is added to prevent the bypass circuit from triggering repeatedly near zero error. This approach keeps the cells within a predetermined voltage range.

Button, Robert

Update on Development of 360V, 28kWh Lithium-Ion Battery

Engineering unit submodule batteries (EUSB) the 360V, 28kWh EAPU battery were designed and assembled by COM DEV. These submodules consist of Sony Li-Ion 18650HC cells in a 5P-41S array yielding 180V, 1.4 kWh. Tests of these and of substrings and single cells at COM DEV and at JSC under various performance and abuse conditions demonstrated that performance requirements can be met. The thermal vacuum tests demonstrated that the worst case hot condition is the design driver. Deficiencies in the initial diode protection scheme of the battery were identified as a result of test failures. Potential solutions to the scheme are under development and will be presented.

Davies, Francis

Interagency Array Study Report

The interagency array study that was convened in early 1982 to determine which of the world's large radio reception facilities might be feasibly and beneficially enlisted to help support the Voyager encounters at Uranus (1986) and Neptune (1989), and also to examine the future for such similar events and options as might appear is discussed. A similar but more specific study of the Parkes Radio Telescope at Uranus Encounter was just then being completed with a strong positive recommendation, and formed the foundation of the broader study. The approach, driving considerations, and outcome of the interagency array study are discussed. The recommendations of the study team concentrated upon the Voyager Encounters are: specifically to develop Parkes for the Uranus Encounter, while pursuing related Advanced Systems development work with the Owens Valley Radio Observatory, and to seek support for the Neptune Encounter from Parkes, the Very Large Array near Socorro, Mexico, and the Japanese institute of Space and Astronautical Sciences 64 meter station.

J W Layland

Global Precipitation Measurement (GPM) Spacecraft Lithium Ion Battery Micro-Cycling Investigation

The Global Precipitation Measurement (GPM) spacecraft was jointly developed by NASA and JAXA. It is a Low Earth Orbit (LEO) spacecraft launched on February 27, 2014. The power system is a Direct Energy Transfer (DET) system designed to support 1950 watts orbit average power. The batteries use SONY 18650HC cells and consist of three 8s by 84p batteries operated in parallel as a single battery. During instrument integration with the spacecraft, large current transients were observed in the battery. Investigation into the matter traced the cause to the Dual-Frequency Precipitation Radar (DPR) phased array radar which generates cyclical high rate current transients on the spacecraft power bus. The power system electronics interaction with these transients resulted in the current transients in the battery. An accelerated test program was developed to bound the effect, and to assess the impact to the mission.

Lithium Ion Battery Performance

Solar Array Arcing in Plasmas

Solar cells in space plasma conditions are known to arc into the plasma when the interconnects are at a negative potential of a few hundred volts, relative to plasma potential. For cells with silver-coated interconnects, a threshold voltage for arcing exists at about -230 V, as found in both ground and LEO experiments. The arc rate beyond the threshold voltage depends nearly linearly on plasma density, but has a strong power-law dependence on voltage, such that for small increments in operating voltage there is a large increment in arc rate. The arcs generate broadband radio interference and visible light. In ground tests, interconnects have been damaged by arcs in cells having insufficient isolation from a source of high current. Models for the arcs are highly dependent on the choice of interconnect conductor material exposed to the plasma and possibly on the geometry and choice of adjacent insulator material. Finally, new technology solar cells use copper for the cell interconnects, a material which may have a lower arcing threshold voltage than silver. It is expected, from ground tests of simulated solar cells, that any junction of conductor and insulator exposed to space plasma conditions will arc into the plasma at a few hundred volts negative potential, relative to the local plasma.

Dale C Ferguson

International Space Station Lithium-Ion Battery Start-Up and Cycling

The International Space Station (ISS) primary Electric Power System (EPS) was originally designed to use Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the ISS is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries were designed to operate at a 35 depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. In 2010, the ISS Program began the development of Lithium-Ion (Li-Ion) batteries to replace Ni-H2 batteries approaching the end of their useful life and concurrently funded a Li-Ion ORU (Orbital Replacement Unit) and cell life testing project. The first set of 6 Li-ion battery replacements was launched in December 2016 and deployed in January 2017. This paper will discuss the Li-ion battery on-orbit cycling and the status of the Li-Ion cell and ORU life cycle testing.

International Space Station

CH3OH and HCN in Interstellar Comet 3I/ATLAS Mapped with the ALMA Atacama Compact Array: Distinct Outgassing Behaviors and a Remarkably High CH3OH/HCN Production Rate Ratio

We report the detection of methanol (CH3OH) toward interstellar comet 3I/ATLAS using the At-acama Compact Array of the Atacama Large Millimeter/Submillimeter Array (ALMA) on UT 2025 August 28, September 18 and 22, and October 1, and of hydrogen cyanide (HCN) on September 12 and 15. These observations spanned pre-perihelion heliocentric distances (r H ) of 2.6 – 1.7 au. The molecules showed outgassing patterns distinct from one another, with HCN production being depleted in the sunward hemisphere of the coma, whereas CH3OH was enhanced in that direction. Statistical analysis of molecular scale lengths in 3I/ATLAS indicated that CH3OH included production from coma sources at Lp > 258 km at 99% confidence. However low signal-to-noise on long baselines, which sample emission on small spatial scales closest to the nucleus, prevented definitively ruling out CH3OH as purely a parent species. In contrast, HCN production was indistinguishable from direct nucleus sublimation. The CH3OH production rate increased sharply from August through October, including an uptick near the inner edge of the H2O sublimation zone at rH = 2 au. Compared to comets measured to date at radio wavelengths, the derived CH3OH/HCN ratios in 3I/ATLAS of 124+30−34 and 79+11−14on September 12 and 15, respectively, are among the most enriched values measured in any comet, surpassed only by anomalous solar system comet C/2016 R2 (PanSTARRS)

Comae

International Space Station Lithium-Ion Battery Status

When originally launched, the International Space Station (ISS) primary Electric Power System (EPS) used Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the space station is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries were designed to operate for ten years at a 35 percent depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. For service beyond that period, upgraded Li-Ion Orbital Replacement Units (ORUs) were designed. These are the largest Li-Ion batteries ever utilized for a human rated spacecraft. With the oldest 12 Ni-H2 battery ORUs cycling since September 2006, the first set of six was replaced by Li-Ion batteries in December 2016; the second set of six is planned for replacement in September 2018. This paper will include an overview of the ISS Li-Ion battery system architecture, on-orbit status of the first 6 batteries, start up of the second 6 batteries, and the status of the Li-Ion cell and ORU life cycle testing.

International Space Station

International Space Station Lithium-Ion Battery

The International Space Station (ISS) primary Electric Power System (EPS) currently uses Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the space station is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries are designed to operate at a 35 depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. Since the oldest of the 48 Ni-H2 battery Orbital Replacement Units (ORUs) has been cycling since September 2006, these batteries are now approaching their end of useful life. In 2010, the ISS Program began the development of Lithium-Ion (Li-Ion) batteries to replace the Ni-H2 batteries and concurrently funded a Li-Ion ORU and cell life testing project. When deployed, they will be the largest Li-Ion batteries ever utilized for a human-rated spacecraft. This paper will include an overview of the ISS Li-Ion battery system architecture, the Li-Ion battery design and development, controls to limit potential hazards from the batteries, and the status of the Li-Ion cell and ORU life cycle testing.

battery

International Space Station Lithium-Ion Battery Start-Up

International Space Station Lithium-Ion Battery Start-Up.The International Space Station (ISS) primary Electric Power System (EPS) was originally designed to use Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the space station is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries are designed to operate at a 35 depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. As the oldest of the 48 Ni-H2 battery Orbital Replacement Units (ORUs) has been cycling since September 2006, these batteries are now approaching their end of useful life. In 2010, the ISS Program began the development of Lithium-Ion (Li-ion) batteries to replace the Ni-H2 batteries and concurrently funded a Li-Ion ORU and cell life testing project. The first set of 6 Li-ion battery replacements were launched in December 2016 and deployed in January 2017. This paper will discuss the Li-ion battery on-orbit start-up and the status of the Li-Ion cell and ORU life cycle testing.

Lithium-Ion

International Space Station Lithium-Ion Battery Status

When originally launched, the International Space Station (ISS) primary Electric Power System (EPS) used Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the space station is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries were designed to operate for ten years at a 35% depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. For service beyond that period, upgraded Li-Ion Orbital Replacement Units (ORUs) were designed. These are the largest Li-Ion batteries ever utilized for a human rated spacecraft. The first set of six Ni-H2 batteries was replaced by Li-Ion batteries in December 2016; the second set of six was launched in September 2018 and installed in March 2019. The third set of six were launched in September 2019. Three batteries were installed in September 2019, with the remaining three to be installed in January 2020. This paper will include a brief overview of the ISS Li-Ion battery system architecture, start up of the second and third set of 6 batteries and the on-orbit status of all 18 batteries, plus the status of the Li-Ion cell life testing.

Lithium-Ion