Search NASA⌕ Search

SEARCH · Search NASA

Results for “Noise floor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Phase noise limited frequency shift impulsive Raman spectroscopy

We introduce a method to enable optical amplification of a coherent Raman spectroscopy signal, which we call radio frequency (RF) Doppler Raman spectroscopy. In this article, we consider the perturbation of a probe pulse in a sample due to an excited Raman vibrational coherence as a generalized Doppler shift, which connects a time-varying optical path length (the product of the propagation length and refractive index, OPL = n ℓ) with an optical frequency shift. Amplification of a Raman signal outside of the focused interaction is enabled by converting the Doppler frequency shift experienced by a laser probe pulse into a periodic timing jitter. This transit time perturbation is detected through the phase of a RF electronic signal measured at a harmonic of the probe pulse train with a method adapted from precision metrology techniques used to measure laser pulse train timing jitter. Measurement of a timing jitter allows access to much lower noise floors than other coherent Raman techniques, and by exploiting the new capability to scale the signal of a coherent Raman spectroscopic signal, this method opens the potential to detect very weak Raman signals that are currently not observable due to limits of illumination intensity imposed by laser damage to the specimen and noise.

47 OTHER INSTRUMENTATION↗

An all-silicon single-wafer micro-g accelerometer with a combined surface and bulk micromachining process

This paper reports an all-silicon fully symmetrical z-axis micro-g accelerometer that is fabricated on a single-silicon wafer using a combined surface and bulk fabrication process. The microaccelerometer has high device sensitivity, low noise, and low/controllable damping that are the key factors for attaining micro g and sub-micro g resolution in capacitive accelerometers. The microfabrication process produces a large proof mass by using the whole wafer thickness and a large sense capacitance by utilizing a thin sacrificial layer. The sense/feedback electrodes are formed by a deposited 2-3 microns polysilicon film with embedded 25-35 microns-thick vertical stiffeners. These electrodes, while thin, are made very stiff by the thick embedded stiffeners so that force rebalancing of the proof mass becomes possible. The polysilicon electrodes are patterned to create damping holes. The microaccelerometers are batch-fabricated, packaged, and tested successfully. A device with a 2-mm x 1-mm proof mass and a full bridge support has a measured sensitivity of 2 pF/g. The measured sensitivity of a 4-mm x 1-mm accelerometer with a cantilever support is 19.4 pF/g. The calculated noise floor of these devices at atmosphere are 0.23 micro g/sqrt(Hz) and 0.16 micro g/sqrt(Hz), respectively.

Non-NASA Center↗

Optimizing Charge-coupled Device Readout Enabled by the Floating-gate Amplifier

Multiple-Amplifier Sensing (MAS) charge-coupled devices (CCDs) have recently been shown to be promising silicon detectors that meet noise sensitivity requirements for next generation Stage-5 spectroscopic surveys and potentially, future space-based imaging of extremely faint objects on missions such as the Habitable Worlds Observatory. Building upon the capability of the Skipper CCD to achieve deeply sub-electron noise floors, MAS CCDs utilize multiple floating-gate amplifiers along the serial register to increase the readout speed by a factor of the number of output nodes compared to a Skipper CCD. We introduce and experimentally demonstrate on a 16-channel prototype device new readout techniques that exploit the MAS CCD’s floating-gate amplifiers to optimize the correlated double sampling by resetting once per line instead of once per pixel. With this new mode, we find an optimal filter to subtract the noise from the signal during read out. We also take advantage of the MAS CCD’s structure to tune the read time by independently changing integration times for the signal and reference level. Together with optimal weighted averaging of the 16 outputs, these approaches enable us to reach a sub-electron noise of 0.9 e − rms pix −1 at 19 μs pix −1 for a single charge measurement per pixel—simultaneously giving a 30% faster readout time and 10% lower read noise compared to performance previously evaluated without these techniques.

Lin, Kenneth W. (ORCID:0000000189672281)↗

Optics-Free Chip-Scale Intraoperative Imaging Using NIR-Excited Upconverting Nanoparticles

Here we present an optics-free CMOS image sensor that incorporates a novel time-gated dual-photodiode pixel design to allow filter- and lens-less image acquisition of near-infrared-excited (NIR-excited) upconverting nanoparticles. Recent biomedical advances have highlighted the benefits of NIR excitation, but NIR interaction with silicon has remained a challenge, even with high-performance optical blocking filters. Using a secondary diode and a dual-photodiode design, this sensor is able to remove the 100s of mV of NIR background on pixels and bring it down to single-digit mV level, nearing its noise floor of 2.2 mV rms, not achievable with any optical filter. Non-linear effects of background cancellation using the diode pair has been mitigated using an initial one-time pixel-level curve fitting and calibration in a post-processing setting. This imager comprises a highly linear 11 fF metal-oxide-metal (MOM) capacitor and includes integrated angle-selective gratings to reject oblique light and enhance sharpness. Each pixel also includes two distinct correlated double sampling schemes, to remove low frequency flicker noise and systematic offset in the datapath. We demonstrate the performance of this imager using pulsed NIR-excited upconverting nanoparticles on standard United-States-Air-Force (USAF) resolution targets and achieve an SNR of 15 dB, while keeping NIR background below 6 mV. This 36-by-80-pixel array measures only 2.3 mm by 4.8 mm and can be thinned down to 25 µm, allowing it to become surgically compatible with intraoperative instruments and equipment, while remaining optics-free.

42 ENGINEERING↗

The Seismic Signatures of Recently Formed Impact Craters on Mars

We investigated the seismic signatures of recent impact crater clusters on Mars that would be recorded by the Interior Exploration using Seismic Investigations, Geodesy and Heat Transport (InSight)seismometers. We used a database of 77 measured and dated impact sites, with craters with diameters between 2.1 and 33.8 m, along with inferred impact angle, bolide trajectory, and varying target material properties to empirically scale for the momentum, expected seismic source function, and radiation pattern of impacts. The impact source is simulated in a local 3‐Dfinite difference wave propagation code and coupled to teleseismic distances by scaling the spectra of 1‐D global synthetic seismograms. We use the InSight seismometer noise floors to estimate detectability of impact(s) across azimuth and distance. Our experiments reveal that impact clusters have a higher peak corner frequency resulting from energy contributed by smaller craters to the power spectrum. We also find that the time separation between individual impacts in a cluster is small (<10–15 ms) and requires a seismometer closely situated to the source (<10 km) and a high sampling rate (>100 Hz) to resolve individual impacts within the cluster. Two of the clusters in our database(>20‐m effective diameter) would have been detectable by InSight, with the assumptions that the Martian background noise and seismic attenuation are both low. Joint detection of surface changes from newly formed crater(s) in images and by InSight will provide precise source locations that are crucial for constraining the internal structure of Mars

N. C. Schmerra↗

A Data Matrix Method for Improving the Quantification of Element Percentages of SEM/EDX Analysis

A simple 2D M N matrix involving sample preparation enables the microanalyst to peer below the noise floor of element percentages reported by the SEM/EDX (scanning electron microscopy/ energy dispersive x-ray) analysis, thus yielding more meaningful data. Using the example of a 2 3 sample set, there are M = 2 concentration levels of the original mix under test: 10 percent ilmenite (90 percent silica) and 20 percent ilmenite (80 percent silica). For each of these M samples, N = 3 separate SEM/EDX samples were drawn. In this test, ilmenite is the element of interest. By plotting the linear trend of the M sample s known concentration versus the average of the N samples, a much higher resolution of elemental analysis can be performed. The resulting trend also shows how the noise is affecting the data, and at what point (of smaller concentrations) is it impractical to try to extract any further useful data.

Lane, John↗

Experimental Modal Analysis Using Phase Quantities from Phase-Based Motion Processing and Motion Magnification

Phase-based motion processing and the associated Motion Magnification that it enables has become popular not only for the striking videos that it can produce of traditionally stiff structures visualized with very large deflections, but also for its ability to pull information out of the noise floor of images so that they can be processed with more traditional optical techniques such as digital image correlation or feature tracking. While the majority of papers in the literature have utilized the Phase-based Image Processing approach as a pre-processor for more quantitative analyses, the technique itself can be used directly to extract modal parameters from an image, noting that the extracted phases are proportional to displacements in the image. Therefore, once phases are extracted, they can be fit using traditional experimental modal analysis techniques. This produces a mode “shape” where the degrees of freedom are phases instead of physical motions. These phases can be scaled to produce on-image visualizations of the mode shapes, rather than operational shapes produced by bandpass filtering. Modal filtering techniques can also be used to visualize motions from an environment on an image using the modal phases as a basis for the expansion.

47 OTHER INSTRUMENTATION↗

Application of ATONA Amplifiers to the Measurement of Uranium Isotopic Ratios by Thermal Ionization Mass Spectrometry

Uranium isotopic composition can provide valuable information about the history and provenance of a nuclear material; therefore, uranium isotopic analyses are frequently made in the nuclear forensics, safeguards, and environmental monitoring communities. These measurements have always presented challenges due to the extreme variability in the relative abundance between the major ( 235 U, 238 U) and minor ( 233 U, 234 U, 236 U) isotopes of uranium. Here, the recently developed ATONA (Atto- to Nano-Amp) amplification system paired with Faraday cup detectors has a large dynamic range and low noise floor making it ideal for measuring uranium isotopic ratios in materials of both natural and anthropogenic origin. A wide variety of certified reference materials were analyzed to investigate the utility of the ATONA amplification system for determining uranium isotopic composition in samples ranging from depleted to highly enriched. The ATONA amplifiers provide nearly an order of magnitude improvement in external reproducibility over 10 11 Ω amplifiers when measuring the minor 234 U/ 238 U ratio in isotopically natural and depleted samples and when paired with a secondary electron multiplier can measure very low relative abundance uranium isotopes (i.e., 236 U).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Platinum nanoparticle compression: Combining in situ TEM and atomistic modeling

The mechanical behavior of nanoparticles governs their performance and stability in many applications. However, the small sizes of technologically relevant nanoparticles, with diameters in the range of 10 nm or less, significantly complicate experimental examination. These small nanoparticles are difficult to manipulate onto commercial test platforms and deform at loads that are below the typical noise floor of the testing instruments. Here, we synthesized small platinum nanoparticles directly onto a mechanical tester and used a modified nanomanipulator to enhance load resolution to the nanonewton scale. We demonstrated the in situ compression of an 11.5-nm platinum nanoparticle with simultaneous high-resolution measurements of load and particle morphology. Molecular dynamics simulations were performed on similarly sized particles to achieve complementary measurements of load and morphology, along with atomic resolution of dislocations. The experimental and simulation results revealed comparable values for the critical resolved shear stress for failure, 1.28 and 1.15 GPa, respectively. Altogether, this investigation demonstrated the promise of, and some initial results from, the combination of atomistic simulations and in situ experiments with an unprecedented combination of high spatial resolution and high load resolution to understand the behavior of metal nanoparticles under compression.

42 ENGINEERING↗

Sparse optimization of two-dimensional terahertz spectroscopy

Two-dimensional terahertz spectroscopy (2DTS) is a low-frequency analog of two-dimensional optical spectroscopy that is rapidly maturing as a probe of a wide variety of condensed matter systems. However, a persistent problem with 2DTS is the long experimental acquisition times, which prevent its broader adoption. A potential solution, requiring no increase in experimental complexity, is signal reconstruction via compressive sensing. In this work, we apply the sparse exponential mode analysis (SEMA) technique to 2DTS of a cuprate superconductor. We benchmark the performance of the algorithm in reconstructing terahertz nonlinearities and find that SEMA reproduces the asymmetric photon echo line shapes at sampling rates as low as 10%, reaching the reconstruction noise floor at sampling rates beyond 20%–30%. The success of SEMA in reproducing such subtle, asymmetric line shapes confirms compressive sensing as a general method to accelerate 2DTS and multidimensional spectroscopies more broadly.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Methods for the robust computation of the long-period seismic spectrum of broad-band arrays

SUMMARY We describe array methods to search for low signal-to-noise ratio (SNR) signals in long-period seismic data using Fourier analysis. This is motivated by published results that find evidence of solar free oscillations in the Earth's seismic hum. Previous work used data from only one station. In this paper, we describe methods for computing spectra from array data. Arrays reduce noise level through averaging and provide redundancy that we use to distinguish coherent signal from a random background. We describe two algorithms for calculating a robust spectrum from seismic arrays, an algorithm that automatically removes impulsive transient signals from data, a jackknife method for estimating the variance of the spectrum, and a method for assessing the significance of an entire spectral band. We show examples of their application to data recorded by the Homestake Mine 3-D array in Lead, SD and the Piñon Flats PY array. These are two of the quietest small aperture arrays ever deployed in North America. The underground Homestake data has exceptionally low noise, and the borehole sensors of the PY array also have very low noise, making these arrays well suited to finding very weak signals. We find that our methods remove transient signals effectively from the data so that even low-SNR signals in the seismic background can be found and tested. Additionally, we find that the jackknife variance estimate is comparable to the noise floor, and we present initial evidence for solar g-modes in our data through the T2 test, a multivariate generalization of Student's t-test.

Caton, Ross C.↗

First Demonstration of Resonant Pitch-Angle Scattering of Relativistic Electrons by Externally Launched Helicon Waves

Helicon waves (a.k.a whistler waves) satisfying the normal wave-particle cyclotron resonance are observed to limit the growth and maximum energy of relativistic electrons (REs) in low-density Ohmic DIII-D tokamak plasmas. Following the application of helicon waves, pitch-angle scattering of high-energy REs causes an increase in both synchrotron and electron-cyclotron emissions. The hard x-ray emission, a proxy for the RE population, ceases to grow. Energy-resolved hard x-ray measurements also show a striking decrease in the number of high-energy REs (above the resonance at approximately 8MeV) to below the noise floor and an increase in low-energy (∼ 4 MeV) REs. This occurs despite the toroidal electric field remaining high enough to drive exponential RE growth in the absence of helicon waves. Furthermore, these results open new directions for limiting the maximum energy of RE populations in laboratory and fusion plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Vapor-Cell-Based Atomic Electrometry for Detection Frequencies below 1 kHz

Rydberg-assisted atomic electrometry using alkali-metal atoms contained inside a vacuum environment for detecting external electric fields at frequencies below a few kilohertz has been quite challenging due to the low-frequency electric-field-screening effect that is caused by the alkali-metal atoms adsorbed on the inner surface of the container. In this work, we report a very slow electric-field-screening phenomenon with a timescale up to the order of seconds on a rubidium-vapor cell that is made of monocrystalline sapphire. Furthermore, using this sapphire rubidium-vapor cell with an optically induced, internal bias electric field, we demonstrate vapor-cell-based, low-frequency atomic electrometry that responds to the electric field strength linearly. Limited by the given experimental conditions, this demonstrated atomic electrometer uses an active volume of 11 mm 3 and delivers a spectral noise floor of around 0.34 mV/m √Hz and a 3-dB low cutoff frequency of around 770 Hz inside the vapor cell. This work investigates a regime of vapor-cell-basedatomic electrometry that was seldom studied before, which may enable more applications that use atomicelectric-field-sensing technology.

74 ATOMIC AND MOLECULAR PHYSICS↗

Magnetic properties of a staggered S = 1 chain with an alternating single-ion anisotropy direction

Materials composed of spin-1 antiferromagnetic (AFM) chains are known to adopt complex ground states that are sensitive to the single-ion-anisotropy (SIA) energy ( D ), and intrachain ( J 0 ) and interchain ( J 1 , 2 ′ ) exchange energy scales. While theoretical and experimental studies have extended this model to include various other energy scales, the effect of the lack of a common SIA axis is not well explored. Here we investigate the magnetic properties of Ni ( pyrimidine ) ( H 2 O ) 2 ( NO 3 ) 2 , a chain compound where the tilting of Ni octahedra leads to a twofold alternation of the easy-axis directions along the chain. Muon-spin relaxation measurements indicate a transition to long-range order at T N = 2.3 K and the magnetic structure is initially determined to be antiferromagnetic and collinear using elastic neutron diffraction experiments. Inelastic neutron scattering measurements were used to find J 0 = 5.107 ( 7 ) K , D = 2.79 ( 1 ) K , J 1 ′ = 0.00 ( 5 ) K , J 2 ′ = 0.18 ( 3 ) K , and a rhombic anisotropy energy E = 0.19 ( 9 ) K . Mean-field modeling reveals that the ground state structure hosts spin canting of ϕ ≈ 6 . 5 ∘ , which is not detectable above the noise floor of the elastic neutron diffraction data. Monte Carlo simulation of the powder-averaged magnetization, M ( H ) , is then used to confirm these Hamiltonian parameters, while single-crystal M ( H ) simulations provide insight into features observed in the data. Published by the American Physical Society 2025

Vaidya, S. (ORCID:000000033975497X)↗

High Resolution Polar Kerr Effect Studies of CsV 3 Sb 5 : Tests for Time-Reversal Symmetry Breaking below the Charge-Order Transition

We report high resolution polar Kerr effect measurements on CsV 3 Sb 5 single crystals in search for signatures of spontaneous time reversal symmetry breaking below the charge order transition at T * = 94 K. Utilizing two different versions of zero-area loop Sagnac interferometers operating at 1550 nm wavelength, each with the fundamental attribute that without a time reversal symmetry breaking sample at its path, the interferometer is perfectly reciprocal, we find no observable Kerr effect to within the noise floor limit of the apparatus at 30 nanoradians. Simultaneous coherent reflection ratio measurements confirm the sharpness of the charge order transition in the same optical volume as the Kerr measurements. At finite magnetic field we observe a sharp onset of a diamagnetic shift in the Kerr signal at T *, which persists down to the lowest temperature without change in trend. Since 1550 nm is an energy that was shown to capture all features of the optical properties of the material that interact with the charge order transition, we are led to conclude that it is highly unlikely that time reversal symmetry is broken in the charge ordered state in CsV 3 Sb 5 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ROI-Finder : machine learning to guide region-of-interest scanning for X-ray fluorescence microscopy

The microscopy research at the Bionanoprobe (currently at beamline 9-ID and later 2-ID after APS-U) of Argonne National Laboratory focuses on applying synchrotron X-ray fluorescence (XRF) techniques to obtain trace elemental mappings of cryogenic biological samples to gain insights about their role in critical biological activities. The elemental mappings and the morphological aspects of the biological samples, in this instance, the bacterium Escherichia coli ( E. Coli ), also serve as label-free biological fingerprints to identify E. coli cells that have been treated differently. The key limitations of achieving good identification performance are the extraction of cells from raw XRF measurements via binary conversion, definition of features, noise floor and proportion of cells treated differently in the measurement. Automating cell extraction from raw XRF measurements across different types of chemical treatment and the implementation of machine-learning models to distinguish cells from the background and their differing treatments are described. Principal components are calculated from domain knowledge specific features and clustered to distinguish healthy and poisoned cells from the background without manual annotation. The cells are ranked via fuzzy clustering to recommend regions of interest for automated experimentation. The effects of dwell time and the amount of data required on the usability of the software are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RadTraQ (Radar Tracking and Quality Toolkit

RadTraQ is a python library housing routines related to assessing and monitoring the quality of a radar's quality and calibration. This library is a work in progress, currently housing scripts to plot radar CFADs, plot and analyze corner reflector scans, calculate noise floors, create cloud masks, and plot up average profiles for comparisons.

THEISEN, ADAMK↗