Search NASA⌕ Search

SEARCH · Search NASA

Results for “Noise in imaging systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

System-on-Chip approach microwave diagnostics development for burning plasma

System-on-chip (SoC) millimeter wave integrated circuit technology has been developed and employed in chip heterodyne radiometers in Electron Cyclotron Emission Imaging (ECEI) and Microwave Imaging Reflectometer (MIR) on the DIII-D tokamak for 2D electron temperature and density fluctuation diagnostics. The W-band (75-110 GHz) ECEI system has been employed with 20 poloidal horn receiver modules with customized monolithic integrated circuit chips and internal local oscillator coupling path. The new SoC approach demonstrates > 30 dB additional gain on the receiver and 95% electronics noise suppression compared to the previous Schottky diode mixer array . An F-band (110-140 GHz) receiver chip has been developed to measure MHD and turbulence behavior on the DIII-D high-field side, such as Alfven eigenmodes. Furthermore, it can image pedestal structure evolution on fusion facilities with stronger magnetic fields, such as ASDEX-U, EAST, HL-2M, and LHD. The F-band chip performance has been tested in the laboratory. Also, V-band (55-75 GHz) transmitter and receiver modules (55-75 GHz) have been developed for DIII-D and NSTX-U Furthermore, microwave Imaging Reflectometer (MIR) application suitability for 2D density fluctuation imaging on the pedestal region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation, optical, power flow, and electrical diagnostics at the Z facility: Layout and techniques utilized to operate in the harsh environment

The Z machine is a current driver producing up to 30 MA in 100 ns that utilizes a wide range of diagnostics to assess accelerator performance and target behavior conduct experiments that use the Z target as a source of radiation or high pressures. Here, we review the existing suite of diagnostic systems, including their locations and primary configurations. The diagnostics are grouped in the following categories: pulsed power diagnostics, x-ray power and energy, x-ray spectroscopy, x-ray imaging (including backlighting, power flow, and velocimetry), and nuclear detectors (including neutron activation). We will also briefly summarize the primary imaging detectors we use at Z: image plates, x-ray and visible film, microchannel plates, and the ultrafast x-ray imager. The Z shot produces a harsh environment that interferes with diagnostic operation and data retrieval. We term these detrimental processes “threats” of which only partial quantifications and precise sources are known. Finally, we summarize the threats and describe techniques utilized in many of the systems to reduce noise and backgrounds.

47 OTHER INSTRUMENTATION↗

Label-free quantum super-resolution imaging using entangled multi-mode squeezed light

Abstract In this study, we explore the theoretical application of entangled multi-mode squeezed light for label-free optical super-resolution imaging. By generating massively entangled multi-mode squeezed light through an array of balanced beam splitters, using a single-mode squeezed light input, we create a multi-mode quantum light state with exceptional entanglement and noise suppression below the shot noise level. This significantly reduces imaging measurement errors compared to classical coherent state light imaging when the same number of photons are used on the imaging sample. We demonstrate how to optimize the imaging system’s parameters to achieve the Heisenberg imaging error limit, taking into account the number of entangled modes and photons used. We also examine the effects of optical losses in the imaging system, necessitating adjustments to the optimized parameters based on the degree of optical loss. In practical applications, this new quantum imaging approach reduces the number of photons needed to achieve the same image quality by two orders of magnitude compared to classical imaging methods that use non-entangled, non-squeezed coherent state light.

Soh, Daniel (ORCID:0000000325625675)↗

Uncertainty-based weighted least squares density integration for background-oriented schlieren

We propose an improved density integration methodology for Background-Oriented Schlieren (BOS) measurements that overcomes the noise sensitivity of the commonly used Poisson solver. Here, the method employs a weighted least-squares (WLS) optimization of the 2D integration of the density gradient field by solving an over-determined system of equations. Weights are assigned to the grid points based on density gradient uncertainties to ensure that a less reliable measurement point has less effect on the integration procedure. Synthetic image analysis with a Gaussian density field shows that WLS constrains the propagation of random error and reduces it by 80% in comparison to Poisson for the highest noise level. Using WLS with experimental BOS measurements of flow induced by a spark plasma discharge shows a 30% reduction in density uncertainty in comparison to Poisson, thereby increasing the overall precision of the BOS density measurements.

42 ENGINEERING↗

Evaluation of a Variable-Aperture Full-Ring SPECT System using Large-Area Pixelated CZT Modules: A Simulation Study for Brain SPECT Applications

Single photon emission computed tomography (SPECT) scanner using cadmium zinc telluride (CZT) offers improved imaging capability over conventional NaI (Tl)-based SPECT scanner. We aim to demonstrate a full-ring SPECT system design with eight large-area CZT detectors that can be used for a broad spectrum of SPECT radiopharmaceuticals and provides higher sensitivity and better spatial resolution than those of conventional NaI (Tl)-based gamma cameras. A newly-designed full-ring SPECT system is composed of 8 large-area CZT cameras (128 mm × 179.2 mm effective area) that can be independently swiveled around their own axes of rotation independently and can have radial motion for varying aperture sizes that can be adapted to different sizes of imaging volume. Extended projection data were generated by conjoining projections of two adjacent detectors to overcome the limited field-of-view (FOV) by each CZT camera. Using Monte Carlo simulations, we evaluated this new system design with digital phantoms including a Derenzo hot-rod phantom and a Zubal brain phantom. Comparison of performance metrics such as spatial resolution, sensitivity, contrast-to-noise ratio (CNR), and contrast-recovery ratio were made between our design and a conventional SPECT scanner. The proposed scanner could result in up to about 3 times faster in acquisition time over conventional scan time at same acquisition time per step. The spatial resolution of our proposed scanner was similar or better to that of the conventional scanner, and there was significant performance improvement over the conventional scanner particularly in sensitivity (approximately 4 times). Overall, we successfully reconstructed the phantom image for both 99 mTc-based perfusion and 123 I-based dopamine transporter (DaT) brain studies simulated for our new design. In particular, the striatal/background contrast-recovery ratio in 3-to-1 reference ratio was over the 0.8 for the 123 I-based DaT study. In conclusion, we demonstrated the potential of our new full-ring CZT SPECT design, showing improved performance metrics such as improved system sensitivity and CNR while maintaining other important imaging parameters such as spatial resolution.

36 MATERIALS SCIENCE↗

System-on-chip approach microwave imaging reflectometer on DIII-D tokamak

System-on-chip millimeter wave integrated circuit technology is used on the two-dimensional millimeter-wave imaging reflectometer (MIR) upgrade for density fluctuation imaging on the DIII-D tokamak fusion plasma. Customized CMOS chips have been successfully developed for the transmitter module and receiver module array, covering the 55–75 GHz working band. The transmitter module has the capability of simultaneously launching eight tunable probe frequencies (>0 dBm output power each). The receiver enclosure contains 12 receiver modules in two vertical lines. The quasi-optical local oscillator coupling of previous MIR systems has been replaced with an internal active frequency multiplier chain for improved local oscillator power delivery and flexible installation in a narrow space together with improved shielding against electromagnetic interference. The 55–75 GHz low noise amplifier, used between the receiver antenna and the first-stage mixer, significantly improves module sensitivity and suppresses electronics noise. The receiver module has a 20 dB gain improvement compared with the mini-lens approach and better than –75 dBm sensitivity, and its electronics noise temperature has been reduced from 55 000 K down to 11 200 K. Further, the V-band MIR system is developed for co-located multi-field investigation of MHD-scale fluctuations in the pedestal region with W-band electron cyclotron emission imaging on DIII-D tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimising the processing and storage of visibilities using lossy compression

The next-generation radio astronomy instruments are providing a massive increase in sensitivity and coverage, largely through increasing the number of stations in the array and the frequency span sampled. The two primary problems encountered when processing the resultant avalanche of data are the need for abundant storage and the constraints imposed by I/O, as I/O bandwidths drop significantly on cold storage. An example of this is the data deluge expected from the SKA Telescopes of more than 60 PB per day, all to be stored on the buffer filesystem. While compressing the data is an obvious solution, the impacts on the final data products are hard to predict. In this paper, we chose an error-controlled compressor – MGARD – and applied it to simulated SKA-Mid and real pathfinder visibility data, in noise-free and noise-dominated regimes. As the data have an implicit error level in the system temperature, using an error bound in compression provides a natural metric for compression. MGARD ensures the compression incurred errors adhere to the user-prescribed tolerance. To measure the degradation of images reconstructed using the lossy compressed data, we proposed a list of diagnostic measures, exploring the trade-off between these error bounds and the corresponding compression ratios, as well as the impact on science quality derived from the lossy compressed data products through a series of experiments. We studied the global and local impacts on the output images for continuum and spectral line examples. We found relative error bounds of as much as 10%, which provide compression ratios of about 20, have a limited impact on the continuum imaging as the increased noise is less than the image RMS, whereas a 1% error bound (compression ratio of 8) introduces an increase in noise of about an order of magnitude less than the image RMS. For extremely sensitive observations and for very precious data, we would recommend a 0.1% error bound with compression ratios of about 4. These have noise impacts two orders of magnitude less than the image RMS levels. At these levels, the limits are due to instabilities in the deconvolution methods. We compared the results to the alternative compression tool DYSCO, in both the impacts on the images and in the relative flexibility. MGARD provides better compression for similar error bounds and has a host of potentially powerful additional features.

Techniques: interferometric↗

The Active Optics System on the Vera C. Rubin Observatory: Optimal Control of Degeneracy among the Large Number of Degrees of Freedom

Abstract The Vera C. Rubin Observatory is a unique facility for survey astronomy that will soon be commissioned and begin operations. Crucial to many of its scientific goals is the achievement of sustained high image quality, limited only by the seeing at the site. This will be maintained through an active optics system that controls optical element misalignments and corrects mirror figure error to minimize aberrations caused by both thermal and gravitational effects. However, the large number of adjustment degrees of freedom available on the Rubin Observatory introduces a range of degeneracies, including many that are induced by noise due to imperfect measurement of the wave-front errors. We present a structured methodology for identifying these degeneracies through an analysis of image noise level. We also present a novel scaling strategy based on truncated singular value decomposition that mitigates the degeneracy and optimally distributes the adjustment over the available degrees of freedom. Our approach ensures the attainment of optimal image quality, while avoiding excursions around the noise-induced subspace of degeneracies, marking a significant improvement over the previous techniques adopted for Rubin, which were based on an optimal integral controller. This new approach is likely to also yield significant benefits for all telescopes that incorporate large numbers of degrees of freedom of adjustment.

79 ASTRONOMY AND ASTROPHYSICS↗

Improving 3D reconstruction quality for root phenotyping: assessing the impact of camera calibration and imaging parameters

Arate 3D reconstruction is essential for high-throughput plant phenotyping, particularly for studying complex structures such as root systems. While photogrammetry and Structure from Motion (SfM) techniques have become widely used for 3D root imaging, the camera settings used are often underreported in studies, and the impact of camera calibration on model accuracyccu remains largely underexplored in plant science. In this study, we systematically evaluate the effects of focus, aperture, exposure time, and gain settings on the quality of 3D root models made with a multi-camera scanning system. We show through a series of experiments that calibration significantly improves model quality, with focus misalignment and shallow depth of field (DoF) being the most important factors affecting reconstruction accuracy. Our results further show that proper calibration has a greater effect on reducing noise than filtering it during post-processing, emphasizing the importance of optimizing image acquisition rather than relying solely on computational corrections. This work improves the repeatability and accuracy of 3D root imaging for phenotyping pipelines by giving useful calibration guidelines. This leads to better trait quantification for use in crop research and plant breeding in downstream analysis.

3D reconstruction↗

The Pristine survey – XX. GTC follow-up observations of extremely metal-poor stars identified from Pristine and LAMOST

Ultra-metal-poor stars (⁠[Fe/H] < –4.0⁠) are very rare, and finding them is a challenging task. Both narrow-band photometry and low-resolution spectroscopy have been useful tools for identifying candidates, and in this work, we combine both approaches. We cross-matched metallicity-sensitive photometry from the Pristine survey with the low-resolution spectroscopic Large Sky Area Multi-Object Fibre Spectroscopic Telescope (LAMOST) data base, and re-analyzed all LAMOST spectra with ⁠[Fe/H] Pristine < –2.5⁠. We find that ~1/3rd of this sample (selected without ⁠[Fe/H] Pristine quality cuts) also have spectroscopic ⁠[Fe/H] < –2.5⁠. From this sample, containing many low signal-to-noise ratio (S/N) spectra, we selected 11 stars potentially having ⁠[Fe/H] < –4.0 or [Fe/H] < –3.0 with very high carbon abundances, and we performed higher S/N medium-resolution spectroscopic follow-up with the Optical System for Imaging and low Resolution Integrated Spectroscopy (OSIRIS) on the 10.4-m Gran Telescopio Canarias (GTC). We confirm their extremely low metallicities, with a mean of [Fe/H] < –3.4⁠, and the most metal-poor star having [Fe/H] < –3.8⁠. Three of these are clearly carbon-enhanced metal-poor (CEMP) stars with +1.65 < [C/Fe] < +2.45⁠. The two most carbon-rich stars are either among the most metal-poor CEMP-s stars or the most carbon-rich CEMP-no stars known, the third is likely a CEMP-no star. We derived orbital properties for the OSIRIS sample and find that only one of our targets can be confidently associated with known substructures/accretion events, and that three out of four inner halo stars have prograde orbits. Large spectroscopic surveys may contain many hidden extremely and ultra-metal-poor stars, and adding additional information from e.g. photometry as in this work can uncover them more efficiently and confidently.

79 ASTRONOMY AND ASTROPHYSICS↗

Extracting forces from noisy dynamics in dusty plasmas

Extracting environmental forces from noisy data is a common yet challenging task in complex physical systems. Machine learning (ML) represents a robust approach to this problem, yet is mostly tested on simulated data with known parameters. Here we use supervised ML to extract the electrostatic, dissipative, and stochastic forces acting on micron-sized charged particles levitated in an argon plasma (dusty plasma). By tracking the sub-pixel motion of particles in subsequent images, we successfully estimated these forces from their random motion. The experiments contained important sources of non-Gaussian noise, such as drift and pixel-locking, representing a data mismatch from methods used to analyze simulated data with purely Gaussian noise. Our model was trained on simulated particle trajectories that included all of these artifacts, and used more than 100 dynamical and statistical features, resulting in a prediction with 50\% better accuracy than conventional methods. Lastly, in systems with two interacting particles, the model provided non-contact measurements of the particle charge and Debye length in the plasma environment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Blazar variability power spectra from radio up to TeV photon energies: Mrk 421 and PKS 2155−304

ABSTRACT We present the results of the power spectral density (PSD) analysis for the blazars Mrk 421 and PKS 2155−304, using good-quality, densely sampled light curves at multiple frequencies, covering 17 decades of the electromagnetic spectrum, and variability time-scales from weeks up to a decade. The data were collected from publicly available archives of observatories at radio from Owens Valley Radio Observatory, optical and infrared (B, V, R, I, J, H, and Kbands), X-rays from the Swift and the Rossi X-ray Timing Explorer, high and very high energy (VHE) γ-rays from the Fermi and Very Energetic Radiation Imaging Telescope Array System as well as the High Energy Stereoscopic System. Our results are: (1) the power-law form of the variability power spectra at radio, infrared, and optical frequencies have slopes ∼1.8, indicative of random-walk-type noise processes; (2) the power-law form of the variability power spectra at higher frequencies, from X-rays to VHE γ-rays, however, have slopes ∼1.2, suggesting a flicker noise-type process; and (3) there is significantly more variability power at X-rays, high and VHE γ-rays on time-scales ≲ 100 d, as compared to lower energies. Our results do not easily fit into a simple model, in which a single compact emission zone is dominating the radiative output of the blazars across all the time-scales probed in our analysis. Instead, we argue that the frequency-dependent shape of the variability power spectra points out a more complex picture, with highly inhomogeneous outflow producing non-thermal emission over an extended, stratified volume.

Goyal, Arti↗

Modeling and simulation study for the design of the Fuel Interrogation and Examination using Submersible Tomography Analysis Mk II instrument

Here, the design of a submersible, gamma-ray tomography system for imaging irradiated nuclear fuel is described. The system—named Fuel Interrogation and Examination using Submersible Tomography Analysis (FIESTA) Mk. II—is a variation on a previous Mk. I I design, which was developed to non-destructively image fuel capsules irradiated in the Advanced Test Reactor at the Idaho National Laboratory. The FIESTA system uses a combination of transmission computed tomography and emission computed tomography to image the restructuring and fission product migration at different points of burnup. Changes made to FIESTA Mk. I reflect the revised design requirements and a need to reduce background noise, largely originating from downscattered photons from fuel and transmission source. The computational design and radiation transport simulations are described.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Development of a synthetic phase contrast imaging diagnostic for turbulence studies at Wendelstein 7-X

Abstract We present a synthetic phase contrast imaging (PCI) diagnostic for studying turbulence at the Wendelstein 7-X (W7-X) stellarator. We first describe the implemented instrument response model, which captures diffraction effects, detector noise, and the long-wavelength cutoff due to the phase plate of the PCI system. To verify the instrument response model, we show that it is capable of reproducing the PCI signal generated by the sound wave speaker used for calibration at W7-X. Next, we discuss the calculation of synthetic PCI signals based on the global, nonlinear gyrokinetic codes GENE-3D and EUTERPE, including results from some of the first stellarator simulations of this type with kinetic electrons (KEs) in GENE-3D. While the simulations used in this work lack a neoclassical radial electric field, which is crucial for reproducing experimental PCI signals, they do indicate that the dominant rotation direction and velocities of the turbulent fluctuations can be inferred from the wave number-frequency spectra of the PCI signals, as expected. The synthetic PCI wave number spectra are further shown to be similar to those of the line-integrated fluctuating electron density, with distinct differences between adiabatic and KE simulations, explainable by previously published turbulence models. For example, the wave number spectra of all adiabatic electron simulations analyzed here follow a power law with an exponent close to −5 for sufficiently large wave numbers. This indicates that universal features of electron density turbulence at W7-X may be studied using the PCI system.

EUTERPE↗

Learned adaptive properties for mitigation of weight perturbations in embedded spiking networks

Recent years have seen an increased importance of neural network inference in edge-based scenarios, which impose size and power constraints requiring novel computing devices. These same edge scenarios may require operating over long periods of time, or exposure to extreme environments, resulting in a drift of neural network weights that cause degraded performance. In searching for ways to develop neural network approaches that perform robustly under these conditions, we propose a biologically-inspired mechanism for the dynamic adaptation of within-neuron parameters that is guided by a global context signal carrying information about perturbations and variability in incoming stimuli. Specifically, we demonstrate that adaptive voltage thresholds or neuronal time constants, when informed by a global context signal, can enable network-level mechanisms to recover from perturbed synaptic weights. Consistent with prior literature, the context-modulated approach is effective for recurrent, but not feedforward networks, by modulating network level dynamics. We demonstrate this approach successfully recovers performance in image classification tasks and spatiotemporal tracking tasks under idealized and Gaussian noise as well as for realistic perturbations from a memristive device when exposed to ionizing radiation. Finally, we discuss how this approach enables the design of robust and energy-efficient neuromorphic systems that perform well, even in resource-constrained scenarios with extreme environments such as edge processing.

context modulation↗

Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy for rapid, label-free biological imaging

Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy is a label-free imaging approach that provides detailed chemical information at high spatial resolution in a sample through nonlinear, coherent excitation of molecular vibrations and detection of Raman spectra. While its utility for biological imaging has been demonstrated, many aspects of this technique must mature before it can be widely adopted. One of the areas of required improvement is imaging speed—most BCARS implementations involve sample rastering, which limits imaging speed. Beam scanning can provide faster BCARS imaging but presents some unique challenges. Here, we describe a beam-scanning BCARS microscopy system that improves spatial resolution twofold and imaging speed by fivefold over a previous beam-scanning implementation. These enhancements were enabled by an improvement in supercontinuum power and the use of a sCMOS camera for its high data transfer rate and low read noise. Implementation of the sCMOS camera required correction for the significant pixel-to-pixel background and photon response nonuniformity. Here, we report on the method that we implemented for calibrating and correcting the pixel-to-pixel differences in sCMOS camera noise.

Dixon, Jessica Z. [Georgia Institute of Technology↗

High-Density Polyethylene Custom Focusing Lenses for High-Resolution Transient Terahertz Biomedical Imaging Sensors

Transient terahertz time-domain spectroscopy (THz-TDS) imaging has emerged as a novel non-ionizing and noninvasive biomedical imaging modality, designed for the detection and characterization of a variety of tissue malignancies due to their high signal-to-noise ratio and submillimeter resolution. We report our design of a pair of aspheric focusing lenses using a commercially available lens-design software that resulted in about 200 × 200-μm2 focal spot size corresponding to the 1-THz frequency. The lenses are made of high-density polyethylene (HDPE) obtained using a lathe fabrication and are integrated into a THz-TDS system that includes low-temperature GaAs photoconductive antennae as both a THz emitter and detector. The system is used to generate high-resolution, two-dimensional (2D) images of formalin-fixed, paraffin-embedded murine pancreas tissue blocks. The performance of these focusing lenses is compared to the older system based on a pair of short-focal-length, hemispherical polytetrafluoroethylene (TeflonTM) lenses and is characterized using THz-domain measurements, resulting in 2D maps of the tissue refractive index and absorption coefficient as imaging markers. For a quantitative evaluation of the lens effect on the image resolution, we formulated a lateral resolution parameter, R2080, defined as the distance required for a 20–80% transition of the imaging marker from the bare paraffin region to the tissue region in the same image frame. The R2080 parameter clearly demonstrates the advantage of the HDPE lenses over TeflonTM lenses. The lens-design approach presented here can be successfully implemented in other THz-TDS setups with known THz emitter and detector specifications.

47 OTHER INSTRUMENTATION↗

A High Angular Resolution Survey of Massive Stars in Cygnus OB2: JHK Adaptive Optics Results from the Gemini Near-Infrared Imager

We present results of a high angular resolution survey of massive OB stars in the Cygnus OB2 association that we conducted with the Near-Infrared Imager camera and ALTAIR adaptive optics system of the Gemini North telescope. We observed 74 O- and early-B-type stars in Cyg OB2 in the JHK infrared bands in order to detect binary and multiple companions. The observations are sensitive to equal-brightness pairs at separations as small as [[Formula]], and progressively fainter companions are detectable out to △K=9 mag at a separation of 2″. This faint contrast limit due to read noise continues out to 10″ near the edge of the detector. We assigned a simple probability of chance alignment to each companion based upon its separation and magnitude difference from the central target star and upon areal star counts for the general star field of Cyg OB2. Companion stars with a field membership probability of less than 1% are assumed to be physical companions. This assessment indicates that 47% of the targets have at least one resolved companion that is probably gravitationally bound. Including known spectroscopic binaries, our sample includes 27 binary, 12 triple, and 9 systems with 4 or more components. These results confirm studies of high-mass stars in other environments that find that massive stars are born with a high-multiplicity fraction. The results are important for the placement of the stars in the Hertzsprung–Russell diagram, the interpretation of their spectroscopic analyses, and for future mass determinations through measurement of orbital motion.

79 ASTRONOMY AND ASTROPHYSICS↗