Evaluation of Properties for Microsample Identification

A study was conducted to determine if individual particle characteristics could be used to identify particles of interest, sub-samples, from bulk post-detonation debris. Three archived post-detonation debris samples were used for this effort. Particles from these samples were identified as active (produced fission tracks), and inactive (did not produce fission tracks), as the first defining characteristic. Morphology was the secondary characteristic to select particles for further study, i.e. spherical/non-spherical. Once particles were identified and isolated, they were characterized by optical microscopy for size in µm, number of fission tracks, morphology, transmitted light color, and reflected light color. Particles were then analyzed by scanning electron microscopy for morphology, elemental content, and compound identification. Raman spectroscopy was attempted on five particles with indeterminate results due to environmental mixing (heterogeneity) during the events of particle formation. Once all non-destructive analyses were completed all particles were analyzed by thermal ionization mass spectrometry to determine isotopic atom percents of plutonium and uranium, and an estimate of atoms of plutonium and uranium in each particle. An estimate of the ratio of uranium to plutonium was also obtained (U/Pu). Data analytics of the data from the particles showed that combining characteristics of the particles have a high probability of identifying particles of interest from bulk post-detonation debris samples. Please note that this version of the report is an abridged version of the full report (Wagnon et al. 2025) that has been edited to be appropriate for public release.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Study on Application of Distributed Network of Sensors with List Mode for NMAC Literature Review

Nuclear material accounting and control (NMAC) for nuclear security detects, deters, and resolves questions related to unauthorized removal (i.e. theft) or misuse of nuclear material. NMAC also serves as a key insider threat mitigation measure and aids in recovery of nuclear material that is missing. Effective nuclear security depends on NMAC for timely and accurate information about nuclear material types, quantities, and locations. Bulk nuclear material processing facilities, however, present unique challenges for effective NMAC due to the presence of large quantities of material in-process and the accumulation of residual material holdup within process equipment. These holdup accumulations can obscure accurate physical inventory taking and complicate efforts to resolve NMAC irregularities at the facility level. Bulk material monitoring systems often rely on material balance calculations and indirect measurement techniques, which may mask protracted theft of smaller amounts of nuclear material. These monitoring limitations have generated increased interest in continuous monitoring technologies, including distributed non-destructive assay (NDA) sensor networks capable of providing real-time or near-real-time measurement of material movement and accumulation within bulk processing environments. Recent advancements in distributed networks of NDA radiation detectors and sensing technologies provide an opportunity to address these limitations. Although such distributed sensor networks have been implemented in select facilities for IAEA Safeguards applications, their potential for supporting NMAC functions specifically tailored to nuclear security objectives remains largely unexplored. Furthermore, emerging list-mode data acquisition technologies have reached high technology readiness levels, enabling time-correlated detection of nuclear events across multiple temporal scales. These capabilities provide enhanced opportunities for accurate holdup measurement, continuous process monitoring, and improved detection of material theft or misuse over time. The increasing global expansion of civil nuclear power and development of related bulk material processing facilities, including those supporting high-assay low-enriched uranium (HALEU) and other advanced reactor fuel fabrication, further increases the need for advanced measurement and monitoring strategies for NMAC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Screening and qualification methodology for SiC end plug processing methods

Deployment of SiC-ceramic-based fuel cladding for light water reactors requires a hermetic end plug–to–cladding joint that can withstand neutron irradiation during normal operation and maintain integrity during design-basis accidents. Reactor experiments have shown that some SiC composite tubes with SiC end plugs can retain hermeticity after irradiation. However, achieving consistent joint performance under irradiation remains a key challenge. Resolving this issue is essential to enable integral irradiation testing and to demonstrate fuel integrity under commercial-reactor irradiation conditions. This report aims to: (1) provide guidance for designing radiation-tolerant end plug joints for SiC cladding; (2) demonstrate experimental methods to detect processing defects that are unstable under neutron irradiation at light-water-reactor-relevant temperatures and doses; and (3) outline a step-by-step approach for designing and conducting reactor experiments to screen joining methods. The resulting data will be used to improve joint processing and to define critical defect types and sizes that must be detected and eliminated through non-destructive evaluation for quality assurance. Based on prior irradiation experiments at the High Flux Isotope Reactor, differential swelling among the cladding, bonding layer, and end plug was identified as an underlying mechanism for irradiation-induced joint degradation. Accordingly, this effect must be considered in the design of radiation-tolerant joining techniques. In this work, miniature SiC end plug joint specimens irradiated during the previous project were analyzed using X-ray computed tomography to characterize the joint microstructure. Digital volume correlation of the tomography data quantified radiation-induced microstructural changes and enabled evaluation of defect-related risks. Finally, ongoing neutron irradiation efforts using larger specimen volumes are presented. These efforts aim to statistically assess joint performance and to build a microstructure–performance (e.g., leak-tightness) dataset to inform processing improvements and quality control.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

AGR-5/6/7 Irradiation Experiment Fission Product Mass Balance

This report presents the fission product mass balance for the AGR-5/6/7 TRISO fuel irradiation experiment. The fission product inventories deposited on capsule components outside of the fuel (e.g., stainless-steel shells, graphite holders, Grafoil disks, and associated hardware) were quantified as part of the post-irradiation examination (PIE) to assess the performance of this fuel. Comparisons were made between these inventories and depletion calculations, non-destructive measurements of fuel fission product inventories in the intact fuel compacts, prior AGR experiments, and results from among each of the five distinct AGR-5/6/7 capsules. The data served as estimates of the condensable fission products released from the fuel during irradiation. Excluding Capsule 1 (which experienced accidental damage during irradiation) and Capsule 3 (which was tested at very high irradiation temperatures of >1300°C), the results indicate that the AGR-5/6/7 fuel performed comparably to fuel from earlier AGR experiments. The mass balance results were also used to estimate the number of particles with in-pile SiC failures. Subject to the assumptions made in these estimates, and excluding Capsules 1 and 3, the in-pile SiC failure rates for AGR-5/6/7 are comparable to those observed in AGR-2.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Update on Radiochemical Assessment of High Burnup Commercially Irradiated Fuel

This work documents an effort to collect burnup measurements on a high burnup rod, designated 6XV, and first cycle accident tolerant fuel (ATF) rod, designated 47I, to enable benchmarking of fuel performance codes and neutronics codes. In addition to measurements, Virtual Environment for Reactor Applications (VERA) full-core-depletion analysis was also performed for the rods that were experimentally analyzed to provide an opportunity for code validation. This effort focuses on collecting data from rods irradiated at Byron Generating Station and shipped to the Oak Ridge National Laboratory (ORNL) hot-cells. This data will also anchor non-destructive examination evaluations of burnup of the various fuel rods undergoing postirradiation examination (PIE) at ORNL. Previous PIE of these fuel rods provides some guidance on the burnup trend across the fuel. Axial gamma spectroscopy scans provide a measure of relative changes in burnup across a fuel pin. Mass spectrometry based burnup measurements performed for this work at specific axial locations in the fuel are fully quantitative. By combining the mass spectrometry data with the gamma scans it is possible to more quantitatively evaluate axial variations in burnup across the entire fuel pin [1]. The combined set of burnup evaluations will be made available to other organizations that have an interest in high burnup radiochemistry data for validation of neutronic simulations and source term evaluation such as the Nuclear Regulatory Commission (NRC).

Harp, Jason [Oak Ridge National Laboratory (ORNL),↗

Combining hyperspectral imaging and micro-X-ray fluorescence imaging methods for ultra-high-resolution biogeochemical analysis

Current non-destructive methods for high-resolution geochemical imaging open new avenues for high-resolution paleoenvironmental research. We discuss how two of these methods, hyperspectral imaging and micro-X-ray fluorescence imaging, can be combined for organic and inorganic geochemical analyses at a micrometer scale.

Zander, Paul [Lawrence Livermore National Laborato↗

Quasiparticle spectroscopy in tantalum films with different Ta/sapphire interfaces

One of the crucial aspects of current research in quantum information science is the identification and control of loss mechanisms in superconducting circuits. Although microwave measurements directly quantify device performance, additional techniques that probe quasiparticle excitations in superconducting films are needed to understand the microscopic mechanisms underlying dissipation and decoherence. Here, we present results from quasiparticle spectroscopy of Ta/sapphire films by measuring the Meissner-state magnetic susceptibility using a precision frequency-domain resonator specifically designed for thin films. We find direct evidence for additional low-energy excitations in samples with lower internal quality factors. These excitations are consistent with deep subgap states due to two-level systems, Yu-Shiba-Rusinov states near the gap edge, and perhaps other pair-breaking mechanisms. The developed non-destructive frequency-domain quasiparticle spectroscopy is a valuable addition to the quantum materials toolbox.

Moirangthem, Bicky Singh [Ames Lab; Iowa State U.]↗

Quasiparticle spectroscopy in tantalum films with different Ta/sapphire interfaces

One of the crucial aspects of current research in quantum information science is the identification and control of loss mechanisms in superconducting circuits. Although microwave measurements directly quantify device performance, additional techniques that probe quasiparticle excitations in superconducting films are needed to understand the microscopic mechanisms underlying dissipation and decoherence. Here, we present results from quasiparticle spectroscopy of Ta/sapphire films by measuring the Meissner-state magnetic susceptibility using a precision frequency-domain resonator specifically designed for thin films. We find direct evidence for additional low-energy excitations in samples with lower internal quality factors. These excitations are consistent with deep subgap states due to two-level systems, Yu-Shiba-Rusinov states near the gap edge, and perhaps other pair-breaking mechanisms. The developed non-destructive frequency-domain quasiparticle spectroscopy is a valuable addition to the quantum materials toolbox.

Moirangthem, Bicky Singh [Ames Lab; Iowa State U.]↗

X-ray Response of the Fully-Depleted, p-Channel SiSeRO-CCD

We present an X-ray characterization of a fully depleted, 725 $μ$m thick p-channel SiSeRO CCD. Measurements with a $^{55}$Fe source yield an energy resolution of $54 \pm 0.9$ eV ($14.6 \pm 0.25 e^{-}$) at 5.9 keV for single-pixel events, demonstrating that the SiSeRO amplifier preserves the intrinsic charge resolution of the CCD under multi-sample non-destructive readout. Characterization with a $^{241}$Am source extends the response to higher-energy photons, with reconstructed spectral features observed between 9-26 keV and the 59.5 keV $γ$ emission. These measurements, together with a muon-derived diffusion calibration, show that charge transport and diffusion are consistent with interactions spanning the full sensor depth. These results demonstrate that the SiSeRO CCD simultaneously achieves sub-electron noise performance and efficient charge collection in a thick, fully depleted silicon detector. This combination enables X-ray spectroscopy across a broad energy range while maintaining sensitivity to faint signals.

Cuevas-Zepeda, Julian↗

Integrating AI and Multi-sensor Technology for better Bioenergy Preprocessing

Integrating multi-sensor identification with machine learning significantly enhances bioenergy preprocessing by using non-destructive, multi-spectral sensors to improve feedstock purity and quality. This approach not only reduces preprocessing costs but also ensures a more efficient and sustainable bioenergy production process.

09 - BIOMASS FUELS↗

Defining Probe Closure Offset and Scan Stitching Methodology for Element Contact Profilometry in the Hot Fuel Examination Facility

The Element Contact Profilometer (ECP) is a non-destructive post-irradiation examination (PIE) method established in the Materials and Fuels Complex (MFC) Hot Fuel Examination Facility (HFEF). The ECP suspends a fuel rod with a standard end-fitting in a vertical orientation and draws it between two opposed Sony probes with sapphire rod tips, which measure the diameter directly as a function of vertical stage position through contact profilometry. The ECP is equipped with concave rollers, which pinch the rod to maintain a consist position between these sapphire probe tips. A schematic of the analysis head is shown in Figure 1. The gripper that suspends the rod end-fitting is able to rotate to allow measuring of any azimuthal angle around the rod. This system is used to characterize the diameter of full-length light water reactor (LWR) irradiated fuel rods at multiple azimuthal angles in support of the Advanced Fuels Campaign (AFC).

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

In situ cryogenic characterization of proton damage in thick p-channel skipper CCDs

Skipper charge-coupled devices (CCDs) are an offshoot of standard silicon pixel detectors and are capable of performing repeated non-destructive charge measurements, enabling deeply sub-electron readout noise. This capability has opened the door to single-photon counting from the near-infrared ($\sim$1.1 $μ$m) to the soft X-ray (several keV), making these devices strong candidates for future astronomical instruments operating in the photon-starved limit. Furthermore, the p-channel architecture used to fabricate Skipper CCDs on n-type silicon has been demonstrated to have an increased hardness to the intense radiation environment of space. Building upon previous irradiation campaigns on room-temperature sensors, here we describe the first radiation-hardness tests of p-channel skipper CCDs at their cryogenic operating temperatures. We assess the performance of the floating-gate output stage and global CCD parameters (charge transfer inefficiency, dark current, hot pixels, and charge traps). We find that these devices maintain excellent performance after displacement damage doses equivalent to ${\sim}$10 years at the Earth/Sun L2 Lagrange point, demonstrating for the first time that these sensors remain radiation-hard in realistic deep-space thermal and radiation environments.

Roach, Brandon M. [Chicago U., KICP] (ORCID:000000↗

Utilization of Unmanned Aircraft Systems for Environmental Purposes at the Savannah River Site – 26578

Born in the 1950s, the Savannah River Plant was constructed as a plutonium and tritium production plant. As the Cold War era came and went, a change of direction was signaled when the name of the facility changed from Savannah River Plant to Savannah River Site (1989) – the main mission at Savannah River shifted from “production” to “cleanup.” The Department of Energy is responsible for managing the 310 square miles of land that is the Savannah River Site and the cleanup/remediation activities that occur. The Savannah River National Laboratory utilizes unmanned aircraft systems to assist with some of those environmental monitoring and remediation activities. One function of unmanned aircraft systems at the Savannah River National Laboratory is conducting aerial photography and videography. Various infrastructure evaluations have been performed with unmanned aircraft – facility rooftop inspections, water tower lock verifications, earthen dam surveys, etc. An unmanned aircraft system has been used for progress footage of remediation projects – Dunbarton Bay remediation, Saltstone Disposal Unit construction, etc. Thermal cameras on an unmanned aircraft system are used to help identify cracks/leaks in structures from vantage points not readily accessible by personnel. Virtual tours of different waste units are conducted with unmanned aircraft systems for Site groups and federal/state regulators to save costs and travel time. Additionally, advanced remote sensing technologies are used on unmanned aircraft systems at the Savannah River Site. Light Detection and Ranging uses laser pulses to measure distances to the Earth's surface or other targets to create highly detailed topographic maps that accurately portray terrain (e.g., elevation changes, slopes, and contours). Data collection with a Light Detection and Ranging unit mounted on an unmanned aircraft system is quick and efficient – large-area surveys are conducted in shorter time frames. Because Light Detection and Ranging can penetrate through foliage and vegetation to ground level, it is being used in conjunction with a watershed model to study the General Separations Area of the Site to determine stormwater flow volume and direction, monitor stream stability, and forecast river flow behavior. A hyperspectral camera captures a wide spectrum of electromagnetic wavelengths across numerous narrow bands, beyond what the human eye can see. It provides detailed spectral information about the objects or surfaces in an image, which can be used to identify and analyze materials based on their spectral signatures. A hyperspectral camera mounted on an unmanned aircraft system has been used at the Savannah River Site for non-destructive evaluation of concrete and concrete structures. Unmanned aircraft systems at the Savannah River Site are also used for the application of herbicide on identified rooftops. P-Reactor and R-Reactor are entombed nuclear reactors at the Savannah River Site. Unwanted vegetation is often present on these rooftops – over time roots can penetrate seams, cracks, and joints of the general roof and concrete caps, leading to water ingress and deterioration of the structural components. For time and cost efficiencies as well as in the interest of personnel safety, an unmanned aircraft is used to dispense herbicide on rooftop areas where vegetation is noticed to help alleviate the issues/hazards.

Lorier, Troy [Savannah River National Laboratory (↗

Post-irradiation examination of AGR-3/4 TRISO fuel compacts using three-dimensional X-ray computed tomography

The AGR-3/4 irradiation tests combined the third and fourth planned irradiation experiments in the US Department of Energy’s Advanced Gas Reactor (AGR) testing campaign of tri-structural isotropic (TRISO) fuel compacts. In this article, we present post-irradiation examination (PIE) using X-ray computed tomography (XCT) of two unirradiated and two irradiated compacts from the AGR-3/4 irradiation tests. The irradiated compacts studied (compact 7–1 and compact 12–4) represent the upper and lower limit of burnup within the AGR-3/4 irradiation experiment. This article presents a detailed quantitative analysis on the post-irradiation structure of TRISO fuel compacts. Various quantitative parameters including shape, size, and packing of kernels, and their spatial distribution, were utilized to gain insights into the structural changes caused by irradiation. The equivalent diameter and sphericity were found to increase and decrease, respectively, in irradiated compact 7–1 due to its higher burnup. Nearest neighbor distance between fuel kernels decreased after irradiation, suggesting irradiation-induced shrinkage of graphitic matrix. Furthermore, each compact in AGR-3/4 irradiation tests contained 20 designed-to-fail (DTF) fuel particles that were meant to act as a source of fission product release to the experiment test train. Furthermore, in the present work, all DTF fuel particles in the four compacts studied were identified, and it was found that they exhibited larger kernel swelling in compact 12–4 and smaller kernel swelling in compact 7–1, compared to the driver particles.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ultrasonic Characterization of Lithium Ion Thermal Runaway Conditions for Real-time Ultrasonic Enabled BMS Integration

The demand for energy storage is growing, and lithium-ion batteries are a promising technology to meet this need due to their high power/energy density, high round-trip efficiency, rapid response time, and portability. However, recent catastrophic events caused by thermal runaway have slowed their adoption, highlighting the need for an early warning system for battery failure. In this work, ultrasound is used to detect physical changes in 950 mAh batteries by identifying material property changes independent of voltage and current. [Ultrasound signal features (e.g., time of flight, maximum frequency component) were extracted as the batteries were cycled and subjected to both constant current and constant voltage overcharge and were used to develop two metrics identifying failure: a warning to detect the start of overcharge and an emergency stop (E-stop) to immediately take the battery out of service. The identification method involved locating magnitude differences of several ultrasound features compared to baseline operation considering different currents and temperatures, and the warning/stopping metrics were consistent across all experiments. For an average overcharge time of 140 minutes, the average warning was issued 124 minutes before the failure and the average E-stop was triggered 94 minutes before failure. As a test of using ultrasound for early warning detection, a battery was forced into overcharge and returned to normal cycling conditions based on the previously determined warning metric. Both the voltage profile and the ultrasound measurements returned to their baseline behavior, indicating that ultrasonic detection can not only identify battery failure before a catastrophic event, but can also provide early enough warnings such that overcharges can be detected and corrected quickly enough so the battery does not need to be decommissioned.]

25 ENERGY STORAGE↗

Variance Preserving Spectral Subsampling

Generating statistically faithful short-duration gamma-ray spectra from a single long measurement is essential in nuclear safeguards, supporting tasks such as algorithm development and machine-learning applications, especially when list-mode data are unavailable. Existing subsampling methods often distort the statistical characteristics of genuine short-duration measurements, leading to biased or unreliable analytical outcomes and thereby undermining downstream tasks. In this work, we compare five subsampling approaches using a benchmark set of 156 genuine replicate spectra collected with a high-purity germanium detector. We evaluate each method with respect to run-to-run variance, channel-to-channel variance, and preservation of total counts (losslessness). Across a wide range of subsampling ratios, only binomial subsampling without replacement consistently reproduces the statistical properties of genuine short-duration spectra, maintaining proper dispersion even in sparse spectral regions and perfectly preserving total counts. These results provide a mathematically principled and practically validated framework for generating synthetically shortened spectra when true short-duration measurements are unavailable.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Mounted Accelerometer Frequency Response of Adhesive Products and Aluminum Frame Quick Mounts

An accelerometer mounting technique has large implications on the frequency range and accuracy of the measurement, with stiffness and the mass relative to the monitored structure as the primary concerns. The International Organization for Standardization (ISO) gives an extensive list in 5348:2021, detailing mounting methods, and provides recommendations for testing mounts that are not specifically defined. In the nuclear industry on the laboratory scale, there is a need for vibration measurements for predictive maintenance and process monitoring that are nondestructive and capable of working in high-temperature environments. Commercial adhesive products with easy application and removal were tested as nondestructive methods, while quick mounts to a commonly used aluminum frame were tested as nondestructive and have potential applicability in high-temperature environments. The sinusoidal excitation method was used, measuring frequencies from 50 Hz to 10 kHz in one-third octave band intervals, utilizing three accelerometers and comparing the results to those obtained with the stud-mounting method. Using the lowest ±3 dB threshold across each accelerometer, foam dots and poster strips were not successful, and foam tapes were accurate up to 2000 Hz, hose clamps and zip ties up to 800 Hz, and a custom 3D printed mount up to 1000 Hz. Knowing the limitations of each mounting technique allows for accurate measurements within the appropriate range.

47 - OTHER INSTRUMENTATION↗