Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Criticality Safety Program (NCSP)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Godiva IV central cavity neutron environment characterization with threshold neutron detectors

Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high-purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.

Whitman, Nicholas H.↗

Hauser-Feshbach Analysis of Fast Neutron-Induced Reactions on Chlorine

Neutron-induced reactions on 35Cl have recently been measured and analyzed in a Hauser-Feshbach framework at Los Alamos National Laboratory. Particular focus has been applied to the “fast” energy range above 100 keV, where these reactions become important for applications like CLYC (Cs 2 LiYCl 6 :Ce) detector characterization and the development of molten chloride fast reactors. However, challenges to applying a purely statistical analysis to this mass range have presented themselves in the form of cross section fluctuations and deviations due to low-mass structure. In this paper, these challenges and their current solutions will be highlighted, as well as preliminary extensions of the analysis to neighboring isotopes and future plans to extend the measurements down to thermal energies.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

DICER: A new instrument at LANSCE to constrain neutron capture rates on radionuclides

With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accurate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and associated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Subcritical Neutron and Gamma Noise Measurements at the Seven Percent Critical Experiment (7uPCX)

As part of a collaborative international effort organized by Lawrence Livermore National Laboratory (LLNL), with key participants from L’Institut de radioprotection et de sûreté nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Sandia National Laboratories (SNL), a series of high-multiplication subcritical neutron and gamma noise measurements were planned and executed. The primary aim of this research was to advance detector technology, assess the validity of gamma noise for subcriticality measurements, and nuclear criticality safety, focusing on collecting list-mode or time-series data from various reactor configurations with multiplication values ranging from 20 to 310. This comprehensive dataset enabled a detailed comparative analysis of multiple detector systems and the results of both neutron and gamma noise measurements. In this work we focus on experimentally comparing the results from neutron and gamma noise measurements. We note good agreement between estimations of the prompt neutron decay constant and demonstrate the effects of changing reactor geometry on the efficiency of the differing methods.

Criticality↗

The MCNP ® 6 code: A decade of progress

After several years of effort involved in merging the Los Alamos National Laboratory MCNP5 and MCNPX codes, in 2013 the first production release of version 6 of the Monte Carlo N-Particle ® , or MCNP ® , code MCNP6.1 was distributed publicly. Since then, three significant releases have been issued: MCNP6.1.1beta in 2014, MCNP6.2 in 2018, and MCNP6.3 in 2023. While each release always contains new features, code enhancements, and bug fixes, each version has had a different primary focus, ranging from improved calculational efficiency to new powerful utilities and tools, to software modernization of the code base. With all that has been learned over the first decade of the MCNP6 code, continuous progress is being made toward a modernized, general-purpose Monte Carlo radiation transport code that remains a trusted resource for the global community of practitioners. This paper describes these first 10+ years of the MCNP6 code and its continually improving data libraries, and gives some insight into how the next decade is expected to unfold.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Introduction, Investigation, and Experimental Validation of a Novel Passive Neutron Spectrometer

Unfolding neutron energy spectra are instrumental for determining personal health effects and calculating dose received. This area of study is heavily researched, and Lawrence Livermore National Laboratory (LLNL) is investigating a passive neutron spectrometer for the purpose of acquiring the information needed to determine personnel dose in the event of a criticality accident. A part of this investigation is presented in this article through the examination of four experimental detector responses (DRs). These four DRs were acquired in the presence of 252 Cf, AmBe, GODIVA, and National Ignition Facility (NIF) neutron sources. An algorithm developed at LLNL was used to unfold the neutron fluence from each of the four DRs, and subsequently, fluence-to-dose conversion factors provided by the American National Standards Institute were used to calculate dose. Additionally, a multistep unfolding process was developed and employed to calculate the effects of both direct (from the source) and indirect (from room return) neutrons. The average error when unfolding the direct DR was less than 8%. The dose from 252 Cf was predicted with only 8% error. The multistep approach allowed for the identification of the low-energy neutrons in the 252 Cf, AmBe, and NIF DRs.

Nuclear Criticality Safety Program (NCSP)↗

Design Optimization of a Criticality Experiment for the Molten Chloride Reactor Experiment Facility

Neutronics simulations of Molten Chloride Fast Reactors have quantifiable biases that arise from nuclear data, modeling choices, or numerical methods. The multiphysics nature of molten salt reactors makes it challenging to disentangle neutronics modeling biases from biases originating from other physical phenomena. In comparison to a mock-up reactor, criticality experiments can specifically assess the neutronics modeling bias while limiting multiphysics effects. The criticality experiment must be neutronically representative of the full-scale reactor to be valuable. Here, in this paper, we describe the design of a criticality experiment to validate only the neutronics of TerraPower’s Molten Chloride Reactor Experiment (MCRE) and its criticality safety upset scenarios. The proposed experiment uses different chlorine-containing materials to maximize its similarity to the MCRE. The design process uses a constrained Bayesian optimization algorithm to investigate different objective functions that use covariance information for 35 Cl nuclear data. The experiments could reduce the nuclear data–induced uncertainty in k eff of the MCRE from 2161 to 886 pcm. They would also increase the upper subcritical limit of the MCRE criticality safety upset scenario from 0.94101 to 0.94476 when using the WHISPER analysis framework.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Machine Learning to Select Experiments Driven by Fundamental Science and Applications for Targeted Nuclear Data Improvement

This work describes a blueprint for a process that accelerates progress in science by quantitatively answering the following question: What is the optimal combination of fundamental-science and application-driven experiments to maximally reduce pertinent data uncertainties? Answering this question entails solving a high-dimensional and complex optimization problem that is best solved with advanced statistic techniques often classified as machine learning. We apply this process within the framework of nuclear data with the aim to select an experiment combination that will reduce uncertainties in 239 Pu nuclear data for neutron energies between 1 and 600 keV. In this field, fundamental-physics driven data, called differential, look at one nuclear physics observable at a time. They are contrasted to application-driven, integral, data where one or few resulting values inform a broad set of nuclear data across several nuclides and energies. The candidates for integral experiments are criticality measurements that were refined by a genetic algorithm to be maximally sensitive to 239 Pu fission cross sections in the desired energy range. Twenty-three candidate differential experiments were investigated and span multiple nuclear physics observables (e.g., total, capture cross sections) for isotopes appearing in the integral experiments. The optimal combination among these candidate experiments was investigated via generalized least squares fitting, augmented with Gaussian processes to ameliorate statistical irregularities in data, and the D-optimality criterion. The latter evaluates for each pair of candidates the joint reduction in uncertainties of all 12200 nuclear data appearing in the integral experiments compared to the knowledge we have from 168 past experiments, theory, and nuclear data. We chose as differential measurements those that investigate 63 Cu and 239 Pu total cross sections, based on D-optimality rank and feasibility constraints. Two integral (criticality) experiments were selected: An experiment with Al 2 ⁢O 3 and graphite interleaved with Pu and a thick Cu reflector explores 1–30 keV, while we target the 30–600 keV range with an experiment that swaps boron in place of graphite with a different geometry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Completion of Surrogate Testing for Low-Temperature TEX and a Look Towards the Future

To address the mounting need for below room temperature nuclear data validation, the Low-Temperature Thermal Epithermal eXperiments (LT-TEX) have been designed. Validation of low-temperature neutron cross sections is necessary to verify any operation at temperatures below room temperature which is typically observed in environments far from the equator. For example, a fissile material transportation truck may routinely observe ambient temperatures down to -40°C, which is the lower temperature bound of the normal conditions of transportation defined in the United States Title 10 Code of Federal Regulations §71.71c2. Additionally, sub-room temperature benchmarks can validate newly produced cross sections, that include novel thermal scattering laws, from North Carolina State University.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MCNP ® Code Version 6.3.1 Theory & User Manual

This document acts as a repository of knowledge for the Monte Carlo N-Particle (MCNP) transport computer code. It is maintained alongside the source code and attempts to introduce new users and re-familiarize experienced users with the theory and practices of using the MCNP code for the wide range of particle transport analyses that it is appropriate for. The latest version of the MCNP code, version 6.3.1, provides the Monte Carlo particle transport community with the latest feature developments and bug fixes in the MCNP code. The MCNP code version 6.0 and later is also known as the MCNP6 code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of the Cohn-alpha Method on Bare Highly Enriched Uranium Using Organic Scintillators [Poster]

The prompt neutron decay constant (α), can be used to calculate the lifetime of prompt fission chains within a multiplying system and verify reactor startup and shutdown. We analyze a fast, bare system consisting of highly enriched uranium (93% 235 U) hemisphere shells known as the Measurements of Uranium Subcritical and Critical (MUSiC). We measured the system with a three by-four array of organic scintillators (OSCAR) to obtain the gamma-ray and fast neutron signals. Pulse shape discrimination was used to isolate the neutron time series data. The Cohn-α method was used to estimate α for 3 supercritical measurements of Configurations 8 MUSiC. We use these estimates to linearly extrapolate α at delayed critical. These values can be compared to highly detailed simulations in MCNP6.2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Importance of Hands-on Training within the Nuclear Industry

Almost all work performed within the nuclear industry requires some form of training, regardless of an individual’s education. While many of the hazards that exist in nuclear operations are present in other industries (e.g., industrial safety), nuclear operations have the unique hazards of radiation and inadvertent criticality. Therefore, these topics require additional training for individuals performing hands-on work or accessing those work areas. Many methods are available to train people including lectures (either with an instructor or automated video), reading procedures/policies, hands-on demonstrations, and on-the-job training.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

HALEU Experiments [Slides]

The DNCSH, through the HALEU Availability Program, needs publicly available benchmarks supporting Advanced Reactor Fuel Cycle and Transportation. LANL is uniquely positioned to support this goal, with its past experiments at TA-18, planned experiments at NCERC, experiment design capability, and ties to industry. The Deimos experiment will be executed soon and serve as a premier benchmark for the program. LANL expects to submit proposals to the call when issued (soon). Additional experiments supporting DNCSH have already been designed

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Investigating a Potential Hafnium Bias in SCALE [Slides]

Previous work has examined the evidence for a gadolinium bias within SCALE. This work extends the previous work to include benchmark models with hafnium experiments from the ICSBEP Handbook. VALID contains only one experiment with hafnium: MIX-COMP-THERM-008. Newly generated models provide an opportunity to assess the potential presence of a hafnium bias.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of Increased Monte Carlo Parameters on Sensitivity Calculations with SCALE [Slides]

For both models and tests, NPG and NSK parameters have only small effects on calculated sensitivity coefficients. Outside of NPG=100, only differences in CFP affected sensitivity coefficient values. Fission reactions ( 235 U) require more NPG values than scattering ( 238 U) reactions – more particles are needed to locate fission sources in the model more accurately. This work confirms the previous results with the IFP method where the CFP parameter has the greatest impact on calculated sensitivity coefficients. While immediate work focuses on fast systems, other model specifications may require a different set of MC parameters.

97 MATHEMATICS AND COMPUTING↗

American Nuclear Society ANS-8 Subcommittee Meeting [Slides]

This presentation details the discussion of agenda topics. Including the minutes from the last meeting and Membership. Additionally covered is ANS-8 and NCSCC ballots, ANS-8 participation report, and ANS-8 New and Old Business.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗