Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Cybersecurity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Towards Software Bill of Materials in the Nuclear Industry

Large, modern industrial facilities often incorporate thousands of digital assets in their operational technology. Regulated facilities, such as nuclear power plants (NPPs), maintain robust cybersecurity and configuration management programs that often use bills of materials (BOMs) for these assets, including make, model, and version of hardware, firmware, and software. However, these BOMs typically capture only first- or second-tier information provided by the original equipment manufacturer (OEM). Unfortunately, as indicated by the increasing number and sophistication of software supply chain attacks, this level of detail is insufficient for identifying all the potential vulnerabilities and risks in software applications. Software BOMs (SBOMs) provide detailed enumeration of components and dependencies within the product or devices, including firmware. SBOMs can be combined with vulnerability data sources and vendor vulnerability attestations to improve vulnerability management and enable rapid identification of affected components when new software vulnerabilities are discovered. Ideally, SBOMs are created by the OEM prior to installation. However, since this practice is not yet commonplace and since NPPs are typically slow to adopt new technology, most NPPs do not incorporate SBOMs into their asset or configuration management programs. Fortunately, SBOMs can be generated by NPPs on existing digital assets to provide further insight into risk management decisions. This report provides an overview of the current SBOM ecosystem and recommends guidance on how to get started in a “crawl, walk, run” manner to develop and implement a sustainable SBOM program for digital assets in an NPP.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cyber threat assessment of machine learning driven autonomous control systems of nuclear power plants

We report advanced cyber-attacks against critical infrastructure and the energy sector are becoming more common. With the invention of autonomous control systems (ACS) within advanced nuclear reactor designs, system designers, reactor operators, and regulators must consider cybersecurity during the design and operational phases. This article provides a cyber threat assessment of machine learning (ML)-based digital twinning (DT) technologies in the context of advanced reactor ACS. A cyber–physical testbed was created to emulate nuclear reactor digital instrumentation and controls (I&C) and act as a basis for the ACS. The ACS was designed as two plant-level DTs predicting reactor malfunctions and determining control actions and two component-level DTs responsible for classifying component states and forecasting component inputs and outputs (I/O). Two duplicate ACS designs– one using a traditional ML framework and one using an automated ML (AutoML) framework– were created and tested against cyber-attacks on training data, real-time process data, and ML model architectures to determine their respective qualitative cyber-risk in terms of likelihood and impact. Both frameworks showed similar cyber-resilience against training, real-time, and ML architecture attacks, proving that neither is inherently more secure. Recommended safeguard and security measures are posed to system designers, reactor operators, and regulators to maintain the cybersecurity of ML-based DT technologies such as ACS, prompting a holistic view of shared responsibility for maintaining cyber-secure ML-based systems.

99 GENERAL AND MISCELLANEOUS↗

Cybersecurity Workforce Training for SMR Integration into Distribution Grids: A Competency Framework and Containerized Hands-On Lab for the SMR/DER/Microgrid Boundary

Small modular reactors (SMRs) and microreactors are entering the U.S. distribution grid as synchronous generation on feeders designed for loads and inverter-based distributed energy resources (DERs). No existing cybersecurity training program addresses this intersection of nuclear operations, DER management, and operational technology security. As subcontractor to Iowa State University on the CyDERMS Center, Argonne analyzed the relevant standards and training landscape, translated the resulting gaps into a twelve-objective competency framework across distribution-operator and graduate-analyst role tracks, and built a containerized training lab using a ∼400-bus composite grid model behind a realistically simulated Modbus TCP SCADA stack. The analysis isolates the balance-of-plant / energy-management-system (BOP/EMS) boundary as the critical jurisdictional seam where, as of March 2026, neither NRC nor NERC CIP cleanly claims cybersecurity responsibility for distribution-connected SMRs. The framework maps each objective across NIST CSF 2.0, ISA/IEC 62443, NIST NICE Task–Knowledge–Skill statements, and NRC RG 5.71 awareness-and-training controls. The training lab implements operator-recognition assessment scenarios spanning grid-side disturbances and telemetry-layer anomalies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced Reactor Safeguards & Security 2024 Program Roadmap

The Advanced Reactor Safeguards and Security (ARSS) program was established to provide research support addressing near term challenges that advanced nuclear reactor vendors face in meeting domestic Material Control and Accounting (MC&A), Physical Protection System (PPS), and Cybersecurity requirements for U.S. construction. The technical work in the program is meant to (1) support nuclear reactor vendors with advanced MC&A, PPS, and Cybersecurity designs for next generation reactors, (2) provide technical bases for the regulator, and (3) promote the integration of Safeguards and Security by Design early in the design process. Existing domestic regulations for safeguards and security, as outlined in the Code of Federal Regulations, were written for large light water reactors, and rule-making efforts are underway to develop regulations more suited to different reactor designs. The ARSS program seeks to remove roadblocks in the deployment of new and advanced reactors by solving regulatory challenges, reducing safeguards and security costs, and utilizing the latest technologies and approaches for robust plant monitoring and protection. This roadmap discusses the goals of the ARSS program, current research, and program plan for the next five years.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Autonomous System Inference, Trojan, and Adversarial Reprogramming Attack and Defense (Final)

In the world of ever-advancing technology, Autonomous Systems (AS) find extensive application, bolstering functionalities of critical infrastructures such as nuclear power plants. These systems, however, are increasingly becoming a target for nefarious activities, namely through inference attacks, trojan attacks, and adversarial reprogramming. This paper delves into a comprehensive exploration of machine learning (ML)-driven autonomous control systems within advanced nuclear reactor designs, revealing the vulnerabilities and proposing strategies for defense against potential cyber-attacks. Advanced cyber-attacks against critical infrastructure and the energy sector are becoming more common. With the invention of autonomous control systems (ACS) within advanced nuclear reactor designs, system designers, reactor operators, and regulators must consider cybersecurity during the design and operational phases. This article provides a cyber threat assessment of machine learning (ML)- based digital twinning (DT) technologies in the context of advanced reactor ACS. A cyber-physical testbed was created to emulate nuclear reactor digital instrumentation and controls (I&C) and act as a basis for the ACS. The ACS was designed as two plant-level DTs predicting reactor malfunctions and determining control actions and two component-level DTs responsible for classifying component states and forecasting component inputs and outputs (I/O). Two duplicate ACS designs– one using a traditional ML framework and one using an automated ML (AutoML) framework– were created and tested against cyber-attacks on training data, real-time process data, and ML model architectures to determine their respective qualitative cyber-risk in terms of likelihood and impact. Both frameworks showed similar cyber-resilience against training, real-time, and ML architecture attacks, proving that neither is inherently more secure. Recommended safeguard and security measures are posed to system designers, reactor operators, and regulators to maintain the cybersecurity of ML-based DT technologies such as ACS, prompting a holistic view of shared responsibility for maintaining cyber-secure ML-based systems. As global reliance on generation III reactors begins to be critically assessed, the evolution towards advanced reactor systems utilizing digital instrumentation and controls (I&C) becomes not merely preferable, but essential. The integration of semi and fully autonomous control systems (ACS), powered by digital I&C and machine learning (ML)-based digital twinning (DT) technologies, emerges as a potent strategy to mitigate operations and maintenance costs, thereby enhancing the economic feasibility of novel reactor designs. However, with a staggering 500% and 380% increase in cyber-attacks reported against the energy sector by the United States Department of Energy (DoE) and the European Union respectively, a surge in cyber vulnerabilities specifically targeting the nuclear industry has been 2 markedly observed. Notable incidents, such as the W32.Ramnit spyware infiltration at the Gundremmingen nuclear power plant in Germany and the Dtrack spyware intrusion at the Kudankulam nuclear power plant in India, while not directly compromising core industrial control systems (ICS), underscore a compelling necessity to fortify cybersecurity protocols in safeguarding reactor systems against increasingly adept digital adversaries. In light of this, our investigation extends beyond conventional cybersecurity parameters, diving into the intricate web of potential vulnerabilities woven into ML-based DTs and ACS in advanced reactor systems. A crafted cyber-physical testbed and preliminary ACS were devised to act as a mirror, reflecting potential configurations of advanced reactor control designs. Moreover, this study is intertwined with a scrutinization of ML models, developed either through conventional, manually tuned methodologies or via automated means through AutoML, probing into their cyber-risk profiles within operational technology (OT) environments. Expanding on this, two distinct ACS blueprints were forged – one navigating through the corridors of traditional ML and the other traversing the path of AutoML – in an effort to holistically encapsulate the considerations pivotal to ML-based DT control system design. Employing the SANS Institute Industrial Control System (ICS) Kill Chain and the MITRE ATT&CK Tactics, Techniques, and Procedures (TTP) framework, a structured analysis was conducted, launching three targeted attacks against the training dataset, real-time dataset, and ML models, therein dissecting the potential cyber-attack implications against both ML frameworks within an ACS milieu. It is essential to note that three distinct categories of attacks were conducted against both ACS configurations, each encompassing three distinct ML-based DTs, cumulating in a total of 18 varied attacks. This exploration extends into the realms of Autonomous System Inference, Trojan, and Adversarial Reprogramming Attack and Defense, unraveling vulnerabilities, and opportunities for fortified defenses against such intrusions, particularly where ML-driven technologies, and by extension, ACS, are deployed. Final recommendations, articulated through a lens of security, safeguard, and implementation considerations, are presented for both traditional and AutoML models, anchoring upon the existing knowledge landscape and ML-based DT modeling for ACS, and are offered as a beacon to guide the nuclear industry through the intricate cybersecurity challenges that lie ahead.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

AWC for Nuclear Material Transportation

Presentation to the Forefront22 Workshop in DC to NNSA DNN. Generalized presentation on Advanced Wireless Communications and areas where Nuclear Material Transportation may find interesting to investigate further for security and cybersecurity interests. Summary of the Forefront22 workshop Traditional wireless communication technologies, such as Wi-Fi and Cellular, have modernized industries worldwide. The Nuclear industry has also started to modernize its operations by utilizing wireless connectivity and is well poised to expand the use of wireless to an increasing number of use cases. The most recent cellular technology, called 5G for Fifth Generation, brings a transformation not only to wireless; but to industries worldwide by fueling the growth of Internet of Things (IoT) and Industrial IoT (IIoT). Availability of additional spectrum e.g., use of millimeter wave (mmWave) spectrum bands, is a critical boost to wireless growth. These advanced wireless technologies bring multiplicative gains in data rates, latency reduction, capacity growth, and localization accuracy, that can be harnessed for Nuclear Nonproliferation activities along with other mission critical applications. However, using these functional advances securely is of utmost important specially for these critical applications. The functional capabilities of these advanced technologies including 5G & Wi-Fi 6, and the associated security issues and mitigations will be discussed in this session. The future technologies including 6G which will follow 5G and newer versions of Wi-Fi will be also introduced.

99 GENERAL AND MISCELLANEOUS↗

Digital Twin Framework for the Resilient Remote Monitoring and Operation of Nuclear Microreactors

The nuclear industry is developing new advanced reactor technologies, and many companies are conceptualizing designs for microreactors, a class of nuclear reactor with a sub-20 MWth power output designed to be factory fabricated, easily transportable, and simple to control. Microreactors offer promising solutions to several use cases for which large-scale plants would not be suitable, and conventional power generation means, notably diesel electric generators, are expensive and logistically difficult. Many of the potential use cases are in isolated locations such as arctic communities, remote mines, and military installations. Therefore, the cost of microreactor deployment and traditional onsite operations pose a challenge that requires new technical solutions to address. One solution that has the potential to greatly improve economics is to operate and monitor microreactors remotely from a centralized location. Remote monitoring and operation are novel concepts to the nuclear industry and will greatly alter the tasks and responsibilities associated with current commercial nuclear power plant operators. As such, it is important to perform research on potential technological solutions and the impacts those solutions have on operations with end-goal of defining a safe and effective remote concept of operations. This paper proposes a framework for resilient remote operation of microreactors enabled by a novel digital twin implementation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Defensive Cybersecurity Architecture Design Using Force-on-Force Cyber-Physical Modeling

Currently, nuclear power plant physical security systems are highly dependent on air-gaps as a protective measure against cyber-threats. Cyber-physical threats become more likely as advanced cyber-threat capabilities to jump air-gaps transition into common use. Defending against the emerging threat of cyber-enabled physical intrusions is poorly understood. The consequence of these cyber-physical attacks has no quantitative analysis method to inform risk-informed, performance-based cybersecurity approaches. By modifying the physical security simulation tool Dante, cyber-physical threat consequence was able to be analyzed on a notional facility. The results of this analysis are used to design a Defensive Cybersecurity Architecture (DCSA) for the physical security system to produce example resilience measures for this notional facility. A DCSA defines security levels to provide a graded approach for defending plant functions, and security zones for trusted communication between systems. This approach can be applied to real world systems to produce physical protection systems and response measures that are resilient to cyber-physical threats.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Advanced Reactor Safeguards & Security Program: Cybersecurity Scenarios

The use of digital control systems and automation in advanced nuclear power systems introduces different types of vulnerabilities compared to legacy (i.e. analog) control systems that cyber adversaries can exploit. These vulnerabilities pose a challenge to reactor operators and cyber operations staff due to the dynamic nature of the event in which a human response or a lack of response can potentially evolve into a worsening plant condition. Using the Department of Homeland Security Cyber and Infrastructure Security Agency’s (CISA) critical infrastructure exercise framework, this document presents several cyber security scenarios typical of digital control systems that could be used in advanced reactor designs. These scenarios can be used in tabletop exercises to evaluate cyber security posture or conduct training on different aspects of cyber security, including detection, threat hunting using indicators of compromise, evaluating incident response, risk mitigation, incident reporting, information sharing and recovery.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Architecture Design for Remote Operation of Microreactors: Poster

The nuclear sector is pursuing a number of advanced reactor concepts, one of which is the microreactor, an advanced reactor characterized by a power output of less than 20 MWth. These reactors are intended for use in applications where traditional power solutions are economically or logistically impractical. One key feature required for the successful deployment of microreactors is a remote operation capability, which can dramatically cut staffing expenses by eliminating the need for licensed operators to be present at the site of each reactor and instead concentrate in a centrally located operations center. In moving to a remote operations framework for nuclear reactors, the number of potential attack surfaces for a cyber adversary looking to cause harm or disruption increases. Therefore, a robust cybersecurity architecture is required to mitigate these potential vulnerabilities. This paper explores the functional infrastructure, security, and communication requirements to adapt remote operations to nuclear applications. It then presents a reference architecture for remote operations of microreactors that applies best practices in cybersecurity and remote communications in the context of a digital twin remote operation system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NNSA Minority Serving Institute Partnership Program (MSIPP)--Indigenous Mutual Partnership to Advanced Cybersecurity Technology (ASPIRE, IMPACT and PAMER); FY22 Q2 Progress Report

The following report summarizes the status update during this quarter for the National Nuclear Security Agency (NNSA) initiated Minority Serving Institution Partnership Plan's (MSIPP) projects titled, Indigenous Mutual Partnership to Advanced Cybersecurity Technology (ASPIRE), Indigenous Mutual Partnership to Advanced Cybersecurity Technology (IMPACT) and Partnership for Advanced Manufacturing Education and Research (PAMER).

42 ENGINEERING↗

Progress on the MARVEL Cybersecurity by Design Model-Based Systems Engineering Project

Formal model-based systems engineering (MBSE) combines a model, systems thinking, and systems engineering to visually depict the boundaries, context, and behavior of interconnected systems, facilitating effective design, development, and utilization of engineered systems throughout the systems engineering lifecycle. Although nuclear reactor vendors employ these tools to integrate functionality, performance, and safety, they are not yet addressing digital risk concerns introduced by use of operational technology, such as digital instrumentation and control systems. To accomplish this objective, the Microreactor Applications Research Validation and EvaLuation (MARVEL) microreactor was used as an MBSE case study. This real-world application provides a first-of-a-kind opportunity to demonstrate the benefits of integrating digital risk and cybersecurity into the MBSE design process of a nuclear reactor. This paper provides an update of the ongoing MARVEL Cyber MBSE project as it specifically relates to the integration of digital risk management and cybersecurity by design.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Precursor Analysis Report: SQL Slammer Worm Infection of Davis-Besse Nuclear Power Plant 2003

The SQL Slammer Worm Infection of Davis-Besse Nuclear Power Plant 2003 Precursor Analysis Report leverages publicly available information about Davis-Besse’s 2003 cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. On 25 January 2003, the SQL Slammer worm infected more than 90% of vulnerable hosts and crashed the internet in 10 to 15 minutes, making it one of the fastest spreading worms in history. SQL Slammer is a fileless, memory-resident worm that remotely exploits a stack-based buffer overflow vulnerability on local hosts to intensively scan and rapidly self-propagate across the internet. The worm infected approximately 300,000 unpatched hosts running Microsoft Structured Query Language (SQL) Server 2000 or Microsoft Desktop Engine (MSDE) 2000 with SQL Server Resolution Service. The SQL Slammer worm indirectly infected FirstEnergy’s Davis-Besse nuclear power plant by first infecting a consultant’s company network server and then propagating through an external misconfigured connection into Davis-Besse’s site network. The infection caused major network congestion, slow performance, data overloads, and the inability of local hosts to communicate with each other, which eventually caused a loss of availability and a loss of view when the Safety Parameter Display System (SPDS) and Plant Process Computer (PPC) crashed. At the time of the infection, the plant was already offline, the digital monitoring systems had redundant analog backups, and the plant control and safety functions were not affected, so there were no concerns of a safety breach. However, this incident resulted in many lessons learned and spawned important discussions about cybersecurity’s role in nuclear safety and electric power reliability regulation, policy, and guidance. Researchers and analysts identified 10 unique techniques utilized during the attack with a total of 640 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Eight of the identified techniques used during Davis-Besse cyber attack were precursors to the triggering event. Analysis identified 596 observables associated with these precursor techniques, 428 of which were assessed to have an increased likelihood of being perceived in the 331 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Internship Presentation: Integrating Safety and Cybersecurity: Security-by-Design with SOWT Analysis for Reactor Testing

This study covers leveraging reactor testing facilities that are primarily designed with a focus on safety to enhance cybersecurity testing. By incorporating reactor security-by-design with reactor safety-by-design principles and adopting defense-in-depth strategies that emphasize both safety and security, the research evaluates applicable cyber tools, models, and solutions. This includes simulating specific cyber-attack scenarios using reactor simulators and performing SWOT (Strengths, Weaknesses, Opportunities, Threats) analysis to improve the cybersecurity of reactor systems.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Assessment of the High Flux Isotope Reactor Cybersecurity Initiative

Recent cyber-attacks on industrial control systems, and inadvertent exposure of nuclear plant systems to cyber-exploits underscore the need for plant operators to adopt and deploy cyber-security defense solutions made for industrial control systems. Of increasing concern is the fact that international cyber hackers are beginning to target critical infrastructure, and because these more modern controls systems depend on advanced use of digital systems, they are more vulnerable than ever before to cyber-attacks. Traditional cyber defense strategies and products that have been available for decades are tailored for use on IT or corporate networks but can cause interruptions and catastrophic damage when deployed on industrial control system networks. The Department of Energy (DOE) Office of Nuclear Energy established the Gateway for Accelerated Innovation in Nuclear (GAIN) program to provide private companies pursuing innovative nuclear energy technologies with access to the technical support necessary to move toward commercialization. One of these GAIN small business vouchers was awarded to Dragos, Inc. to enable collaboration with Oak Ridge National Laboratory (ORNL) to evaluate the Dragos Platform on a production nuclear reactor test bed, hence laying the path for future commercial adoption. The vision was to provide a guide for industrial operators on implementing an industrial monitoring solution and to show how these solutions can be deployed without causing safety and reliability issues. This report documents the results of the collaboration between ORNL and Dragos, Inc.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗